P R.IC)

R.IWY'ACCELERATEDRIDS PROCESSING REGULATORY INFORMATXON DISTRXBUTION SYSTEM (RIDS) 0 NOTES ACCESSION NBR:9503130325 DOC.DATE: 95/03/03 NOTARIZED:

NO DOCKET FACIL:50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION GIBSON,L.S.

Indiana Michigan Power Co.

(formerly Indiana

& Michigan Ele p

RECIP.NAME RECIPIENT AFFILIATION MARTIN,J.B.

Document Control Branch (Document Control Desk)

>R SUMECT: Forwards "Rept of XSIs From 920702-941211" for Cook Nuclear Power Plant, Unit 2."

DISTRIBUTION CODE.

R047D COPIES RECEIVED.LTR /

ENCL

)

SIZE. + $0 TXTLE: OR Submittal: Inservice/Testing/Relief from ASME Code GL-89-04 RECIPXENT ID CODE/NAME PD3-1 LA HICKMAN,J INTERNAL: AEOD/SPD/RAB NRR/DE/EMCB NUDOCS-ABSTRACT RES/DSIR/EIB COPIES LTTR ENCL 1

1 1

1 1

1

~ FILE CENTER4~~01 1

1 NRR/DE/EMEB=.

1 1

OGC/HDS2 1

1 COPIES LTTR ENCL 1

1 1

1 1

1 1

0 EXTERNAL: LITCO BROWN,B NOAC 1

1 1

1 LITCO RANSOME,C NRC PDR 1

1 1

1 D

0 C

u N

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVASTE!CONTACTTHE DOCL'CLIENTCONTROL DESK, ROOM Pl-37 (EXT. 504-2083 ) TO ELlliII.PATE YOUR 4AMLZ PRO!iI DISTRIBUTIONLISTS I'OR DOC!.'iMENTS YOU DON"I'EED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL 13

I

(

CA Indiana Michigan Power Company Cook Nuclear Plant One Cook Place Bridgrnan, Ml 49106 61 6 465 5901 Cook Nuclear Plant Unit 2 Docket No. 50-316 License No.

DPR-74 ISI NIS-1 Report U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

205SS Attn:

J.

B. Martin March 3, 1995

Dear Mr. Martin:

Attached please find a copy of the NIS-1 Report for Inservice Inspection activities performed at the Cook Nuclear Power Plant, Unit 2, State of Michigan, Number M-324232-M, located in Bridgman, Michigan.

The Plant is owned by Indiana Michigan Power

Company, One Summit Square, Ft.
Wayne, Indiana 46802.

The unit's commercial service date is July 1, 1978 and has a

gross generating capacity of 1100 MWe.,

The Authorized Code Inspector is Mr. M. K. Muterspaugh from Factory Mutual Engineering, whose address is 30150 Telegraph

Road, Bingham Office Park Suite 141, Bingham Farms, Michigan 48025.

The examinations,

tests, replacements and repairs performed, conditions observed, and corrective measures taken are summarized in the attached report.

ISI activities were performed in accordance with the rules and requirements of ASME Code Section XI 1983 Edition, Summer of 1983 Addenda.

Respe 'ly, L.

. Gibson Assistant Plant Manager D.

C.

Cook Nuclear Plant cbm i30042 Attachment c:

See attached distribution.

9503130325 950303 PDR ADOCK 05000316 9

PDR

ISI NIS-1 Report Distribution March 3, 1995 Page 2

c:

E.

E. Fitzpatrick (w/o attachment)

G. Charnoff (w/o attachment)

J.

R. Padgett

- MI Public Serv.

Commission (w/o attachment)

D. R.

Hahn - NFEM Section Chief (w/o attachment)

W. T. Russell NRR Director (w/o attachment).

J. A. Isom - D.

C.

Cook Resident Inspector (w/o attachment)

L. S. Gibson -

(w/o attachment)

G. A. Weber (w/o attachment)

C. A. Freer (w/o attachment)

File

k'