N.R.C.

OPERA NG DATA REPORT DOCKET NO ~

50-315 DATE 06/Jan/95 COMPLETED BY JD Janisse TELEPHONE 616-465-5901 OPERATING STATUS

1. Unit Name D.

C.

Cook Unit 1

2. Reporting Period Dec 1994 'otes
3. Licensed Thermal Power (MWt) 3250 4.

Name Plate Rating (Gross MWe) 1152

5. Design Electrical Rating "(Net MWe) 1020 6.

Maximum Dependable Capacity (GROSS MWe) 1056 7.

Maximum Dependable Capacity (Net MWe) 1000

8. If Changes Occur in Capacity Ratings (Items no.

3 through

7) Since Last Report Give Reasons 9.

Power Level To Which Restricted. If Any (Net MWe) 10, Reasons For Restrictions. If Any:

11. Hours in Reporting Period 12.

No. of Hrs. Reactor Was Critical

13. Reactor Reserve Shutdown Hours
14. Hours Generator on Line
15. Unit Reserve Shutdown Hours 16.

Gross Therm.

Energy Gen.

(MWH) 17.

Gross Elect.

Energy Gen.

(MWH)

18. Net Elect.

Energy Gen.

(MWH)

19. Unit Service'actor
20. Unit Availability Factor
21. Unit Capacity Factor (MDC Net)
22. Unit Capacity Factor (DER Net)
23. Unit Forced Outage Rate 24.

Shutdowns Scheduled over Next Six None This Mo.

Yr. to Date 744.0 8760.0 744.0 6256.5 0.0 0.0 744.0 6215.0 0.0 0.0 2414279 18594802 790390 5982780 763062 5759517 100.0 70.9 100.0 70.9 102.6 65.7 100.6 64.5 0.0 0.0 Months (Type, Date,and Cumm.

175320.0 131910.9 463.0 129823.6 321.0 382120577 124005440 "119281315 75.0 75.0 67.8 66.0

5.8 Duration)

25.,If Shut Down At End of Report Period, Estimated Date of Startup:

26

~ Units in Test Status (Prior to Commercial Operation):

Forecast Achieved INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION 950ll90i63 950lii PDR ADQt K 050003l5 R,

. PDR.

DOCKET NO.

50-315 UNIT ONE DATE 06/Jan/95 COMPLETED BY JD Janisse TELEPHONE 616-465-5901 DAY 94/12/01 94/12/02 94/12/03 94/12/04 94/12/05 94/12/06 94/12/07

'4/12/08 94/12/09 94/12/10 94/12/11 94/12/12 94/12/13 94/12/14 94/12/15 94/12/16 MONTH AVERAGE DAILY POWER LEVEL 1023 1030 1022 1024 1019 1024 1019 1025 1023 1025 1021 1024 1024 1025

'1024 1025 Dec 1994 DAY 94/12/17 94/12/18 94/12/19 94/12/20 94/12/21 94/12/22 94/12/23 94/12/24 94/12/25 94/12/26 94/12/27 94/12/28 94/12/29 94/12/30 94/12/31 AVERAGE DAILY POWER LEVEL 1026 1031 1029 1027 1028 1027 1029 1027 1033 1031 1029 1030 1030 1017 1023

DOCKET O.:

UNIT NAME COMPLETED BY:

TELEPHONE:

DATE:

PAGE'0-315 D.C.

Cook Unit 1 D. L. Bublick (616) 465-5901 Jan 5, 1995 Page 1 of 1 MONTHLY OPERATING ACTIVITIES DECEMBER 1994 H1GHLIGHTS The unit entered this reporting period in Mode 1 at 100< RTP.

The unit exited this reporting period in Mode 1 at 1004 RTP.

There were no challenges to the pressurizer safety valves or power operated relief valves.

Gross Electrical generation for the month of December was 790390 MWH.

DETAILS There were no significant items to report.

UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH: DECEMBER 1994 UNIT NAME:

DATE!

COMPLETED BY:

TELEPHONE:

PAGE:

D~ C.

COOK..UNIT 1-Jan 5, 1995'.

L. Bublick (616) 465-5901 Page 1 of 1~

DURATION NO DATE TYPES' HOURS METHOD OF SHUTTING DOWN REASON~

REACTOR~

LICENSEE.

EVENT REPORT NO.

SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION CODEX'ODES TO PREVENT RECURRENCE None There were no unit shutdown or significant power reductions from 100%

RTP this month.

1 F:

S:

Forced Scheduled 2

Reason:

A:

Equipment Failure (Explain)

B:

Maintenance or Test C:

Refueling D:

Regulatory Restriction E:

Operator Training and License Examination F:

Administrative G:

Operational Error (Explain)

H:

Other (Explain) 3 Method:

1:

Manual 2:

Manual Scram 3:

Automatic Scram 4:

Other (Explain) 4Exhibit G Instructions for preparation of data entry sheets for Licensee Event Report.

(LER) File (NUREG 1061) 5Exhibit I:

Same Source

~<<

'L I