ML17332A371

From kanterella
Jump to navigation Jump to search
Forwards Assessment of Indications in DC Cook Unit 2 Head Penetration 75 & Proprietary Rept WCAP-14118,Rev 1, Structural Integrity Evaluation of Rv Upper Head Penetrations.... Proprietary Rept WCAP-14118 Withheld
ML17332A371
Person / Time
Site: Cook 
Issue date: 10/26/1994
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Russell W
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17332A372 List:
References
AEP:NRC:1218, NUDOCS 9411010267
Download: ML17332A371 (5)


Text

VH.IC)'R:I EY (ACCELERATED RIDS PROCI'.SSIiG REGULATORY XNFORMATION DISTRIBUTION SYSTEM (RIDS)

,v',

t'CCESSION NBR:9411010267 DOC.DATE: 94/10/26 NOTARIZED: YES DOCKET N

FACIL:50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana M

05000316 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co.

(formerly Indiana 6 Michigan Ele RECIP.NAME RECIPIENT AFFILIATION RUSSELL,W.T.

Document Control Branch (Document Control Desk)

SUBJECT:

Forwards "Assessment of Indications in DC Cook Unit 2 Head Penetration 75" 6 proprietary rept WCAP-14118,Rev 1,

"Structural Integrity Evaluation of RV Upper Head Penetrations...."

Proprietary rept WCAP-14118 withheld.

DISTRIBUTION CODE:

APOID COPIES RECEIVED:LTR g ENCL Q SIZE: ~ ~ 9' TITLE: Proprietary Review Distribution Pre Operating License

& Operating R

NOTES:

RECXPIENT ID CODE/NAME PD3-1 LA HICKMAN,J INTERNAL. FILE CENTER 0.

EXTERNAL: NRC PDR COPIES LTTR ENCL 1

1 3

3 1

1 1

0 RECIPIENT ID CODE/NAME PD3-1 PD OGC/HDS2 COPIES LTTR ENCL 1

1 0

YOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE iVKSTE!COYTACTTHE DOC!.'ifENTCONTROL DESK, ROO!if P I -37 (EAT. 504-2083 ) TO ELI%1INATE YOUR N'AhfL' ROif DISTRIBUTION LIS'I'S I'OR DOCL'NfEN'I'S YOI.'ON"I'EI'.D!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 8

ENCL 6

indiana Michigan Power Company P.O. Box 16631

~ Columbus, OH 43216 AEP:NRC:1218 Donald C. Cook Nuclear Plant Unit 2 Docket No. 50-316 License No. DPR-59 CRDM REACTOR VESSEL HEAD PENETRATION ASSESSMENT U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.

C.

20555 Attn:

W. T. Russell October 26, 1994

Dear Mr. Russell:

As requested by your staff in a telephone conference with American Electric Power Service Corporation personnel on October 24,

1994, we are providing our CRDM Reactor Vessel Head Penetration Assessment for your review and approval.

Attachment 1

contains Westinghouse Electric Corporation's "Assessment of Indications In Donald C.

Cook Unit 2

Head Penetration 75," which addresses the as-found conditions and how we are bounded by the analysis of the generic WCAP-13565, "Alloy 600 Reactor Vessel Head Adaptor Tube Cracking Safety Evaluation."

The NRC's "Safety Evaluation for Potential Reactor Vessel Head Adaptor Tube Cracking," dated November 19,

1993, responded to and accepted WCAP-13565.

As a

result of the inspection and Westinghouse's assessment of the CRDM penetration number 75, we intend to perform another inspection during the next refueling outage.

Attachment 2 contains Westinghouse Electric Corporation's report WCAP-14118, Revision 1,

entitled "Structural Integrity Evaluation of Reactor Vessel Upper Head Penetrations to Support Continued Operation:

D. C. Cook Unit 2."

The report is considered proprietary to Westinghouse Electric Corporation.

As such, an affidavit for withholding from public disclosure is provided in.

267 941026 OCK 050003ih PDR 0: 0033 94iioio PDR AD P

~ ~

Il SW

Mr. W. T. Russell 2-AEP:NRC'1218 The current schedule indicates that Unit 2 could be ready to enter mode 4 late Friday night, October 28, 1994.

We do not intend to enter mode 4 until we receive notification that our report has been approved.

Mode 4 was chosen as the constraint since this is where our technical specifications for pressure boundary leakage apply.

Therefore, your expeditious review and approval is greatly appreciated.

Sincerely, gENgp~i)

E.

E. Fitzpatrick Vice President eh Attachments cc:

A. A. Blind G. Charnoff J.

B. Martin - Region III NFEM Section Chief NRC Resident Inspector

- Bridgman J.

R. Padgett

ATTACHMENT 1 TO AEP:NRC:1218 ASSESSMENT OP INDICATIONS IN DONALD C COOK VNIT 2 HEAD PENEGUTION 75