Amends 179 & 163 to Licenses DPR-58 & DPR-74,respectively, Allowing Portion of Waste Gas Holdup Sys Explosive Monitoring Sys to Be Inoperable for 160 Days on One Time Basis
ML17332A210
Person / Time
Site: Cook  
(DPR-58-A-179, DPR-74-A-163)
Issue date: 07/07/1994
From: Marsh L
Office of Nuclear Reactor Regulation
To:
Shared Package
ML17332A211 List:
References
NUDOCS 9407140071
Download: ML17332A210 (14)


Text

~8 REGII

~o Cy

'l O

I O~

V/

+~

~0

+a*++

'UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON( O.C. 20)55-0001 INDIANA MICHIGAN POWER COMPANY DOCKET NO.'0-315'ONALD C.

COOK NUCLEAR PLANT UNIT NO.

1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 179 License No.

DPR-58 k

l.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

B.

C

~

The application for amendment by Indiana Michigan Power Company (the licensee) dated November 17,

1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I'

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

9oo7leoo7l ezo707 PDR ADOCK 05000315 P

PDR

2.

Accordingly, the license is'amended by changes to the Technical.

Specifications as indicated in the attachment t'o this license amendment; and paragraph 2.C.(2) of Facility Operating. License No.

DPR-58 is 'hereby amended to read as follows:

Technical S ecifications The Technical Specifications contained in Appendices A and B,

as revised through Amendment No. f79

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

Ouly 7, 1994 Ledyard B. Harsh Dir,ector Project Directorate III-I Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation

ATTACHMENT TO LICENSE AMENDMENT NO.i79 TO FACILITY'PERATING LICENSE NO.

DPR-58 DOCKET NO. 50-315 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

REMOVE 3/4 3-63 3/4 3-64 3/4 3-66 3/4 3-67 INSERT 3/4 3-63 3/4 3-64 3/4 3-66 3/4 3-67

TABLE 3 3-13 adioactive Gaseous Effluent Monitorin Instrumentation'nstrument Instrument Minimum Channels

~eiable

~CT~IO 1.

Waste Gas Holdup System Explosive Gas Monitoring System3 a.

Hydrogen Monitor (QC-1400) b.

Oxygen Monitor (QC-'1400, QC-370)

(1)

(2) 30 29 2.

Condenser Evacuation System a.

Noble Gas Activity Monitor (SRA-1905) b.

Flow Rate Monitor(SFR-401)

(1-MR-054 'and/or SRA-1910)

(1)

(1)

(1) 28 27 27 3

Unit Vent. Auxiliary Building Ventilation System a.

Noble Gas Activity Monitor (VRS-1505) b.

Iodine Sampler Cartridge for VRS-1503 c.

Particulate Sampler Filter for VRS-1501 d;

Effluent System Flow Rate Measuring Device (VFR-315)

(1-MR-054 and/or VRS-1510) e.

Sampler Flow Rate Measuring Device (VFS-1521) 28 32 32 27 27 27 4.

Containment Purge System a.

Aux. Building Vent. System Noble Gas ActivityMonitor (VRS-1505) b.

Aux. Building Vent. System Particulate Sampler for VRS-1501 31 32 5.

Waste Gas Holdup System a.

Noble Gas Activity Monitor Providing Alarm and Termination of Gas Decay Tank Releases (VRS-1505) 33 COOK NUCLEAR PLANT - UNIT 1 3/4 3-63 AMENDMENT NO. M, M0 179

TABLE 3.3-13,(Cont)

Instrument Instrument Minimum Channels

~Oeeeble licabilit

~OTION 6.

Gland Seal Exhaust a.

Noble Gas Activity Monitor (SRA-1805) b.

Flow Rate 'Monitor(SFR-201)

(1-MR-054 and/or SRA 1810) 28 27 27 At all times During'waste gas holdup system operation (treatment for primary system gases)

        • During releases via this pathway For purge purposes only.

See Technical Specifications 3,3.3.10, Table 3.3-13 and Table 4.3-9 (Items 3.a, S.a in both tables) for non-purging requirements associated with this instrument.

2For gas decay tank releases only, see Item 3 (Unit Vent, Auxiliary Building Ventilation System) for additional requirements.

3The waste gas holdup system explosive gas monitoring system may be inoperable for up to 160 days on a one-time basis for the purpose of replacing one oxygen monitor.

During this time grab samples for oxygen are to be taken and analyzed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

COOK NUCLEAR PLANT - UNIT 1 3/4 3-64 AMENDMENT NO. 04, 440 179

TABLE 4.3-9 adioactive Gaseous Effluent Monitorin "Instrumentation Surveil1anc'e Re uirements

-'nstrument Instrument CHANNEL SOURCE CHECK CHECK CHANNEL

. CHANNEL FUNCTIONAL, CALIBRATION TEST 1.

Waste Gas Holdup System Explosive Gas Monitoring System a.

Hydrogen Monitor (QC-1400) b.

Oxygen Monitor (QC-1400)

Oxygen~%'onitor(Alt.,QC-370)

NA Q(3)

Q(4)

Q(4) 2.

Condenser Evacuation System a.

Noble Gas Activity Monitor (SRA-1905) b.

System Effluent Flow Rate (SFR-401, 1-MR-054, SRA-1910)

NA R(2)

Q(1) 3.

Auxiliary Building Ventilation System a.

Noble Gas Activity Monitor (VRS-1505) b.

Iodine Sampler (For VRS-1503) c.

Particulate. Sampler (For VRS-1501) d.

System Effluent Flow Rate Measurement Device (VFR-315, 1-MR-054, VRS-1510) e.

Sampler Flow Rate Measurement Device (VFS-1521)

I NA NA NA NA R(2)

NA NA Q(1)

NA 4.

Containment Purge System a.

Aux. Building Vent.

System Noble Gas Activity Monitor (VRS-1505) b, Aux. Building Vent.

System Particulate Sampler (For VRS-1501)

COOK NUCLEAR PLANT - UNIT 1 3/4 3-66 R(2)

NA Q(1)

NA AMENDMENT NO ~ 04, 420 179

TABLE 4.3-9 (Continued)

Ins trument Ins trument CHANNEL CHECK CHANNEL SOURCE CHANNEL'.

~

FUNCTIONAL CHECK CALIBRATION TEST 5.

Waste Gas Holdup System a.

Noble Gas Activity Monitor Providing Alarm & Termination of Gas Decay Tank Releases (VRS-1505)

R(2)

Q(5) 6, Gland Seal Exhaust a.

Noble Gas Activity (SRA-1805) b.

System Effluent Flow Rate (SFR-201, 1-MR-054, SRA-1810)

D**

NA R(2)

Q(1)

At all times.

During release via this pathway.

During waste gas holdup system operation (treatment for primary system offgases)

These surveillances are not required during the 160-day period in which this monitor is being replaced.

COOK NUCLEAR PLANT - UNIT 1 3/4 3-67 AMENDMENT NO.

179

~S AE00 Cy 0

oQ gO

+w*w+

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 INDIANA MICHIGAN POWER COMPANY DOCKET NO. '50-316 DONALD C.

COOK NUCLEAR PLANT UNIT NO.

2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 163 License No.

DPR-74 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Indiana Michigan Power Company (the licensee) dated November 17,

1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Commission's rules and regulations set forth in 10 CFR Chapter I;

B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

D.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly', the license is amended by changes to the Technical ',

Specifications as i.ndicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.

DPR-74 is hereby amended to read as follows:

~

Technical S ecifications The Technical Specifications contained in Appendices A and B,

as revised through Amendment No.'163

, are hereby incorporated in the license.

The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMHISSION

Attachment:

Changes to the Technical Specifications Date of Issuance:

~uly 7, 1994 Ledyard B. Harsh, Director Project Directorate III-I Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation

ATTACHMENT TO LICENSE AMENDMENT NO.

163 FACILITY OPERATING LICENSE NO. DPR-74 DOCKET N0..50-316 ll Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.

The revised pages are identified by amendment number and contain vertical lines indicating the area of change.

REMOVE 3/4 3-59 3/4 3-60 3/4 3-62 3/4 3-63 INSERT 3/4 3-59 3/4 3-60 3/4 3-62 3/4 3-63

TABLE 3.3-13'dioactive Gaseous Effluent on tori Instrumentati nstrument Instrument

. 1.

Waste Gas Holdup System Explos)ve Gas Monitoring System a.

Hydrogen Monitor (QC-1400) b.

Oxygen Monitor (QC-1400, QC-370)

Minimum Channels

~Oer!!bla (1)

(2) 30 29 2.

Condenser Evacuation System a.

Noble Gas Activity Monitor (SRA-2905) b.

Flow Rate Monitor (SFR-401)

(2-MR-054 and/or SRA-2910)

(1)

(1)

(1) 28 27 27 3.

Unit Vent, Auxiliary Building Ventilation System a.

Noble Gas Activity Monitor (VRS-2505) b.

Iodine Sampler Cartridge for VRS-2503 c.

Particulate Sampler Filter for VRS-2501 d.

Effluent System Flow Rate Measuring Device (VFR-315)

(2-MR-054 and/or VRS-2510) e.

Sampler Flow Rate Measuring Device (VFS-2521) 28 32 32 27 27 27 4.

Containment Purge System a.

Aux. Building Vent System Noble Gas Activity Monitor (VRS-2505) b.

Aux. Building Vent.

System Particulate Sampler for VRS-2501 31 32 5.

Waste Gas Holdup System a.

Noble Gas Activity Monitor Providing Alarm and Termination of Gas Decay Tank Releases (VRS-2505) 33 COOK NUCLEAR PLANT - UNIT 2 3/4 3-59 AMENDMENT NO. 80, 444 163

TABLE 3.3-13 (Cont)

Instrument Instrument Minimum Channels

~Oeaab e

licabil t bOTTON 6.

Gland Seal "Exhaust a.

Noble Gas Activity Monitor (SRA-2805) b.

Flow Rate Monitor {SFR-201)

(2-MR-054 and/or SRA 2810)

(1)

(1)

(1) 28 27 27 At all times.

During waste gas holdup system operation (treatment for primary system gases)

        • During releases via this pathway.

1 For purge purposes only, see Technical Specifications 3 '.3.10, Table 3.3-13 and Table 4,3-9 (Items 3.a, S.a in both tables) for non-purging requirements associated with this instrument.

2 For gas decay tank releases only, see.Item 3 (Unit Vent, Auxiliary Building Ventilation System) for additional requirements.

3 The waste gas holdup system explosive gas monitoring system may be inoperable for up to 160 days on a one-time basis for the purpose of replacing one oxygen monitor.

During this time grab samples for oxygen are to be taken and analyzed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

COOK NUCLEAR PLANT - UNIT 2 3/4 3-60 AMENDMENT NO. 4Q, 444 163

TABLE 4.3-9 Radioactive Gaseous Ef lueat Moni'tori I strumentatio Surveillance Re uirements Instrument Instrument CHANNEL CHANNEL' SOURCE CHANNEL FUNCTIONAL CHECK CHECK CALIBRATION

~TEE 1.

Waste Gas Holdup System Explosive Gas Monitoring System a.

Hydrogen Monitor (QC-1400) b.

Oxygen Monitor (QC-1400)

Oxygen+4**

Monitor (Alt. QC-370)

D*+4 NA NA NA Q(3)

Q(4)

Q(4) 2.

Condenser Evacuation System a.

Noble Gas Activity Monitor (SRA-2905) b.

System Effluent Plow Rate (SFR-401, 2-MR-054, SRA-2910) 3.

Auxiliary Building Ventilation System a.

Noble Gas Activity Monitor (VRS-2505) b.

Iodine Sampler (For VRS-2503)

c..Particulate Sampler (For VRS-2501) d.

System Effluent Plow Rate Measure-ment Device (VFR-315, 2-MR-054, VRS-2510) e.

Sampler Flow Rate Measurement Device (VFS-2521) 4.

Containment Purge Syst: em a.

Aux. Building Vent.

System Noble Gas Activity Monitor (VRS-2505) b.

Aux. Building Vent System Particulate Sampler (For VRS-2501)

D**

D*

NA NA NA NA NA R(2)

R R(2)

NA R(2)

Q(1)

Q(1)

NA Q(1)

COOK NUCLEAR PLANT - UNIT 2 3/4 3-62 AMENDMENT NO. 80, 444 163

TABLE 4.3-9 (Cont)

CHANNEL CHANNEL SOURCE CHANNEL FUNGTIONAL Instrument Instrument

'HECK CHECK CALIBRATION 5.

Waste Gas Holdup System a.

Noble Gas Activity Monitor Providing Alarm & Termination of Gas Decay Tank Releases (VRS-2505) 6.

Gland Seal Exhaust a.

Noble Gas Activity (SRA-2805) b.

System Effluent Flow Rate (SFR-201, 2-MR-054, SRA-2810)

D**

NA R(2)

R(2)

Q(5),

Q(1)

At all times During release via this pathway During waste gas holdup system operation (treatment for primary system offgases)

        • These surveillances are not required during the 160-day period in which this monitor is being replaced.

COOK NUCLEAR PLANT - UNIT 2 3/4 3-63 AMENDMENT NO. 80, 114 163