FORD I

D

s/

F

NOTES:

REGULATORY INFORMATION DISTRIBUTION SYSTEM.(RIDS)

I

ACCESSION NBR:9405170023

DOC.DATE: 94/05/09

NOTARIZED:

NO

DOCKET I

FACIL:50-315 Donald

C.

Cook Nuclear

Power Plant, Unit 1, Indiana

M

05000315

50-316 Donald

C.

Cook Nuclear

Power Plant, Unit 2, Indiana

M

05000316

UTH.NAME

AUTHOR AFFILIATION

ROPP,W.J.

Region

3 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

FITZPATRICK,E.

Indiana Michigan Power

Co. (formerly Indiana

& Michigan Ele

SUBJECT-:

Forwards

insp repts

50-315/94-05

6 50-316/94-05

on

940312-0422.No violations noted.NRC concerned w/util

I

continued

problems

w/maint on motor-driven auxiliary

feedwater

pumps.

DISTRIBUTION CODE:

IE01D

COPIES

RECEIVED:LTR

ENCL

SIZE:

TITLE: General

(50 Dkt)-Insp Rept/Notice of Vio ation

esponse

RECIPIENT

ID CODE/NAME

PD3-1

PD

INTERNAL: AEOD/DEIB

AEOD/DSP/TPAB

DEDRO

NRR/DRCH/HHFB

NRR/DRSS/PEPB

NRR/PMAS/ILPB2

OE DIR

REG FILE

02

GN3~ILE

0 1

EXTERNAL: EGGG/BRYCE,J.H.

NSIC

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1'

1

RECIPIENT

ID CODE/NAME

HICKMAN,J

AEOD/DSP/ROAB

AEOD/TTC

NRR/DORS/OEAB

NRR/DRIL/RPEB

NRR/PMAS/ILPB1

NUDOCS-ABSTRACT

OGC/HDS2

RES/HFB

NRC

PDR

COPIES

LTTR ENCL

1

1

1

1

1

1

1

1

1

1

1

'

1

1

1

1

1

1

1

1

NOTE TO ALL RIDS" RECIPIENTS:

PLEASE HELP US TO'REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION

LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

22

ENCL

22

0

V

~ i \\

NAY 0 8 typal

Docket No. 50-315

Docket No. 50-316

Indiana Hichigan

Power

Company

ATTN:

Hr.

E.

E. Fitzpatrick

Vice President

1 Riverside

Plaza

Columbus,

OH

43216

Dear Hr. Fitzpatrick:

This refers to the routine safety inspection

conducted

by Hessrs.

James

A.

Isom,

and David J. Hartland of this office. from Harch

12,

1994 through

April 22,

1994.

The inspection

included

a review of activities at your

Donald

C.

Cook Nu'clear Plant, Units

1 and 2, facility.

At the conclusion of

the inspection,

the findings were discussed

with those

members of your staff

identified in the enclosed report.

Areas

examined during the inspection

are identified in the report.

Within

these

areas,

the inspection consisted of a selective

examination of procedures

and representative

records,

observations,

and interviews with personnel.

No violations of NRC requirements

were identified during this inspection.

Previous

Inspection

Reports

50-315/93016

and 50-316/93018

documented

problems

with maintenance

on motor-driven auxiliary feedwater

(HDAFW) pumps.

Even

though you established

actions for these

problems,,we

are concerned

with the

continuing problems you are having with the maintenance

of your

HDAFW pumps.

Problems

noted during this inspection

included operators

not questioning

elevated

bearing temperatures

on

a

HDAFW pump that maintenance

had improperly

reassembled.

This area will continue to be monitored in future inspections.

In accordance

with 10 CFR 2.790 of the Commission's regulations,

a copy of

this letter the enclosure(s),

and your response(s)

to this letter will be

placed in the

NRC Public Document

Room.

9405170023

940509

".

PDR

ADOCK 05000315

8

PDR

Indiana Michigan Power

Company

MAY 0;

>gg4

We wil,l gladly discuss

any questions

you have concerning this inspection.

Sincerely,

Enclosure:

Inspection

Report

No. 50-315/94005(DRP);

No. 50-316/94005(DRP)

=

Distribution

cc w/enclosure:

A. A. Blind, Plant Manager

OC/LFDCB

Resident

Inspector,

RIII

James

R. Padgett,

Michigan Public

Service

Commission

EIS Coordinator,

USEPA

Region

5 Office

Michigan Department of

Public Health

D. C.

Cook,

LPH,

NRR

bcc:

PUBLIC

W. J. Kropp, Chief

Reactor Projects

Section

2A

R )I

~ sini

P'k

RIIJ

pe ReCy<

Wp0

n

+a*<<<<

UNITED STATES

NUCLEAR REGULATORY COMMISSION

AEGION III

80> VIARRENVILLEROAD

LISLE. ILLINOIS%532-4351

h$N 0:

-,09

Docket No. 50-315

Docket

No. 50-316

Indiana Michigan Power

Company

ATTN:

Hr.

E.

E. Fitzpatrick

Vice President

1 Riverside

Plaza

Columbus,

OH

43216

Dear Hr. Fitzpatrick:

This refers to the routine safety inspection

conducted

by Messrs.

James

A.

Isom and David J.. Hartland of this office from March 12,

1994,

through

April 22,

1994.

The inspection

included

a review of activities at your

Donald

C.

Cook Nuclear Plant,

Units

1

and 2, facility.

At the conclusion of

the inspection,

the findings were discussed

with those

members

of your staff

identified in the enclosed

report.

Areas

examined

during the inspection

are identified in the report.

Within

these

areas,

the inspection consisted

of a selective

examination of procedures

and representative

records,

observations,

and interviews with personnel.

No violations of NRC requirements

were identified during this inspection.

Previous

Inspection

Reports

50-315/93016

and 50-316/93018

documented

problems

with maintenance

on motor-driven auxiliary feedwater

(HDAFW) pumps.

Even

though you established

actions for these

problems,

we are concerned

with the

continuing problems

you are having with the maintenance

of your

HDAFW pumps.

Problems

noted during this inspection

included operators

not questioning

elevated

bearing temperatures

on

a

HOAFW pump that maintenance

had improperly

reassembled.

This area will continue to be monitored in future inspections.

In accordance

with 10 CFR 2".790 of the Commission's

regulations,

a copy of

this letter

and the enclosed

inspection report will be placed

in the

NRC

Public Document

Room.

M~v (

9

-~ggq

Indiana Michigan Power

Company

We will gladly discuss

any questions

you have concerning this inspection.

Sincerely,

~ger"

W. J.

Kvopp, Chief

Reactor Projects

Section

2A

Enclosure:

Inspection

Report

No. 50-315/94005(DRP);

No. 50-316/94005(DRP)

Distribution

cc w/enclosure:

A. A. Blind, Plant Manager

OC/LFDCB

Resident

Inspector, RIII

James

R. Padgett,

Michigan Public

Service

Commission

EIS Coordinator,

USEPA

Region

5 Office

Michigan Department of

Public Health

D.

C.

Cook,

LPM,

NRR