Application for Exigent Amend to License DPR-58,revising TS 4.4.5, SGs to Incorporate Acceptance Criterion for SG Tube Degradation in Tubesheet Region Known as F*.Westinghouse Repts WCAP-13970 & WCAP-13971 encl.WCAP-13970 Withheld
Date released: 05/31/2018 Download: ML17331B239


Nonproprietary F* Tube Plugging Criterion for Tubes W/ Degradation in Tubesheet Roll Expansion Region of DC Cook Unit 1 Sgs.
ML17331B242
Person / Time
Site: Cook 
Issue date: 02/28/1994
From: Esposito J, Renee Taylor
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To:
References
Download: ML17331B242 (36)
Requests That Proprietary Rept WCAP-13970, F* Tube Plugging Criterion for Tubes W/Degradation in Tubesheet Roll Expansion Region of DC Cook Unit 1 SGs Be Withheld from Public Disclosure,Per 10CFR2.790
ML17331B241
Person / Time
Site: Cook 
Issue date: 02/07/1994
From: Liparulo N
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: MURLEY T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17331B241 (17)
Proposed Tech Specs Incorporating Acceptance Criterion for SG Tube Degradation in Tubesheet Region Known as F*
ML17331B240
Person / Time
Site: Cook 
Issue date: 02/15/1994
From:
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
References
Download: ML17331B240 (12)
Application for Exigent Amend to License DPR-58,revising TS 4.4.5, SGs to Incorporate Acceptance Criterion for SG Tube Degradation in Tubesheet Region Known as F*.Westinghouse Repts WCAP-13970 & WCAP-13971 encl.WCAP-13970 Withheld
ML17331B238
Person / Time
Site: Cook 
Issue date: 02/15/1994
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17331B238 (16)