ML17331B179
| ML17331B179 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 12/27/1993 |
| From: | Blind A INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG |
| To: | Martin J NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| NUDOCS 9401120083 | |
| Download: ML17331B179 (5) | |
Text
,. ACCELERATED DQTIUBUTION DEMONSATION SYSTEM
,le REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:9401120083 DOC.DATE: 93/12/27 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.
Cook Nuclear Power Plant, Unit 1, Indiana M
05000315 AUTH.NAME AUTHOR AFFILIATION BLIND,A.A.
Indiana Michigan Power Co. (formerly Indiana 6 Michigan Ele RECIP.NAME RECIPIENT AFFILIATION MARTIN,J.B.
Document Control Branch (Document Control Desk)
SUBJECT:
Lists tests 6 exams tentatively scheduled to be performed during Unit 1 refueling outage ISI,scheduled to begin early Feb 1994 for review.Listinq for.Class 1
6 2 welds to be examined per second 10-yr interval long term plan encl.
DISTRIBUTION CODE:
A047D COPIES RECEIVED:LTR 2 ENCL /
SIZE:
TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code NOTES D
RECIPIENT ID CODE/NAME PD3-1 LA HICKMAN,J INTERNAL: AEOD/DSP/ROAB NRR/EMCB OC~PDC FIL 01 EXTERNAL EGGG BROWN g B NRC PDR COPIES LTTR ENCL 1
0 2
2 1
1 1
1 1
0 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DE/EMEB NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB EGGG RANSOME,C NSIC COPIES LTTR ENCL 1
1 1
1 1
1 1
0 1
1 1
1 1
1 D
D D
NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WARM CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 16 ENCL 13 D
D S
~I C
J h
(y, a~r Indiana Michigan~
Power Company ~
Cook Nuclear Plant One Cook Place Bridgrnan, Ml 49106 616 465 5901 Donald C.
Cook Nuclear Plant Unit 1 Docket No. 50-315 License No.
SUBJECT:
UNIT 1 REFUELING OUTAGE ISI U. S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, D.
C.
20555 Attn:
J.
B. Martin December 27, 1993
Dear Mr. Martin:
Pursuant to the requirements of ASME Section XI, 1983 Edition with 1983 Summer Addenda, IWA-1400(c), the following is a listing for your review of tests and examinations tentatively scheduled to be performed during the 1994, Unit 1 Refueling Outage.
The Refueling Outage is scheduled to begin early February, 1994.
Identification of specific valves (i.e. safety valves, check valves, etc.)
can be obtained by referencing the Cook Plant Valve Test Program for the Second Ten Year Inspection Interval.
Eddy Current Testing on 100: of the tubes on all four (4) steam generators.
2
~
Search and retrieval of the secondary side on all four (4) steam generators.
3
~
Visual Examinations on selected reactor closure head penetrations.
4.
5.
Visual Examination of disassembled check valves to check internal integrity and operability.
In-place UT Examinations on all four (4) Reactor Coolant Pump flywheels.
.940i'120083
-" PDR ADOCK
'8 y ~
100083 93f227 05000315 PDR'
1994 Refueling Outage ISI Page 2 of 3
December 27, 1993 6.
7 ~
MT and VT of Primary Manway bolting on four (4) steam generators.
Setpoint Test all three (3) pressurizer safety valves.
8.
Setpoint Test thirty-four (34) Class 2 and 3 safety valves.
9.
27 Hydrostatic Tests of Class 1, 2, and 3 Systems.
10.
UT and Surface Examination of Class 1 and 2 pipe welds.
11.
Visual Examination of Class 1 flange bolting.
12.
Visual Examination of Class 1,
2, and 3 component supports.
Please see the attached listing for Class 1 and 2 welds scheduled to be examined per the Second Ten Year Interval Long Term Plan.
The following Section XI ASME Code Cases which are listed in Regulatory Guide 1.147 may be implemented, if necessary.
Code Case N-416 "Alternative Rules for Hydrostatic Testing of Repair or Replacement of Class 2 Piping,Section XI, Division l."
Code Case N-460 "Alternative Examination Coverage for Class 1 and Class 2 Welds,Section XI, Division l."
Code Case N-481 "Alternate Examination Requirements for Cast Austenitic Pump Casings,Section XI, Division 1."
Code Case N-498 "Alternative Rules for 10-Year Hydrostatic Pressure Testing for Class 1
and 2 Systems,Section XI, Division 1."
1994 Refueling Outage ISI Page 3 of 3 December 27, 1993 If there are any comments or questions or if further information is needed, please feel free to contact Jim Fitchuk at (616) 465-5901, Extension 1410.
Since Blind Plant Manager AAB/cbm Attachments c:
E.
E. Fitzpatrick J.
R. Padgett G. Charnoff NFEM Section Chief NRC Resident Inspector File