~p.S RaCui
~G>>
Vp
+
0 C
C on C
': e
/j ++*sr+
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20666-0001 November 17, 1993 Docket Nos.
50-315 and 50-316 Mr. E.
E. Fitzpatrick, Vice President Indiana Michigan Power Company c/o American Electric Power Service Corporation 1 Riverside Plaza
- Columbus, Ohio 43215
Dear Mr. Fitzpatrick:
SUBJECT:
INSTRUMENTATION TO FOLLOW THE COURSE OF AN ACCIDENT (REGULATORY GUIDE 1.97)(TAC NOS. M51080/M51081)
Section 6.2 of Generic Letter 82-33 requested licensees to provide a report on their implementation of Regulatory Guide 1.97 (Revision 2), including methods for complying with the Commission's regulations and supporting technical justification for any proposed alternatives or deviations.
A large number of
'exception requests were received from pressurized water reactor licensees asking that the environmental qualification requirement for accumulator level and pressure monitoring instrumentation be relaxed from Category 2 to Category 3, which would allow commercial grade instruments to be used.
Prior to 1987 these requests were denied by the staff.
Since then, these exceptions have been considered as an open item until a generic resolution can be found.
The staff has now reviewed the bases for these exceptions and has concluded that no operator action is based on this post-accident instrumentation and that it does not perform a safety function.
Since this instrumentation does not perform any post-accident safety function, its qualification requirements can be reduced to Category 3.
A copy of the safety evaluation is enclosed.
You have already installed Category 2 instrumentation to monitor accumulator level and pressure.
You are no longer bound by this commitment, and may, at your discretion, replace this instrumentation with Category 3 instrumentation.
Please notify me of the actions you plan to take and the schedule for implementation.
9312030207 93iii7 PDR ADOCK 050003i5 P
1 y~',~!>> f)fPg
Mr. E.
E. Fitzpatrick November 1 7, f993 This request for information was approved by the Office of Management and Budget under clearance number 3150-0011 which expires June 30, 1994.
Comments on burden and duplication may be directed to the Office of Management and Budget, Reports Management Room 3208, New Executive Office Building, Washington, D.C.
20503.
If you have any questions regarding this issue, please do not hesitate to contact me on (301) 504-1355.
Sincerely, Original signed by Beth A. Wetzel, Acting Project Manager Project Directorate III-1 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation
Enclosure:
Safety Evaluation cc:
w/enclosure See next page DISTR I BUTION QDocket File NRC
& Local PDRs PD31 Reading JRoe JZwolinski ABlough CJamerson BWetzel OGC ACRS (10)
BJorgensen, RIII A. Hansen I. Ahmed OFFICE IIAHE DATE LA:PD31 CJamerson ll/& 93 PM: PD31 BWetzel:
1 ll /+ 93 A D:PD31 ABlou h 11 /
93 OFFICIAL RECORD COPY FILENAME: G: iWPDOCSiDCCOOKiCORG197. LTR
Mr. E.
E. Fitzpatrick Indiana Michigan Power Company CC:
Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Attorney General Department of Attorney General 525 West Ottawa Street
- Lansing, Michigan 48913 Township Supervisor Lake Township Hall Post Office Box 818 Bridgman, Michigan 49106 Al Blind, Plant Manager Donald C.
Cook Nuclear Plant Post Office Box 458 Bridgman, Michigan 49106 U.S. Nuclear Regulatory Commission Resident Inspector Office 7700 Red Arrow Highway Stevensville, Michigan 49127 Gerald Charnoff, Esquire
- Shaw, Pittman, Potts and Trowbridge 2300 N Street, N.
W.
Washington, DC 20037 Mayor, City of Bridgman Post Office Box 366 Bridgman, Michigan 49106 Special Assistant to the Governor Room 1 - State Capitol
- Lansing, Michigan 48909 Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3423 N. Logan Street P. 0.
Box 30195 Lansing, Michigan 48909 Donald C. Cook Nuclear Plant Mr. S. Brewer American Electric Power Service Corporation 1 Riverside Plaza
- Columbus, Ohio 43215
0 ec
~a C
tlat&
<<r Q i
'f)
V'j
'1