N.R.C.
OPERATING DATA REPORT DOCKET NQ.
50-3 16 DATE 02/Oct/93 COMPLETED BY DG TURNER TELEPHONE 616-465-5901 OPERATING STATUS
- 1. Unit Name D.
C.
Cook Unit 2
- 2. Reporting Period SEPT 1993
- 3. Licensed Thermal Power (MWt) 3411 4.
Name Plate Rating (Gross MWe) 1133 5.
Design Electrical Rating (Net MWe) 1090 6.
Maximum Dependable Capacity (GROSS MWe) 1100 7.
Maximum Dependable Capacity (Net MWe) 1060 notes
- 8. If Changes Occur in Capacity Ratings (Items no.
3 through
- 7) Since Last Report Give Reasons 9.
Power Level To Which Restricted. If Any (Net MWe) 10.
Reasons For Restrictions. If Any:
- 11. Hours in Reporting Period 12.
No. of Hrs. Reactor Was Critical
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator on Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Therm.
Energy Gen.
(MWH) 17.
Gross Elect.
Energy Gen.
(MWH)
- 18. Net Elect.
Energy Gen.
(MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (MDC Net)
- 22. Unit Capacity Factor (DER Net)
- 23. Unit Forced Outage Rate 24.
Shutdowns Scheduled over Next Six None.
This Mo.
Yr. to Date 720.0 6551.0 720;0 6282.5 0.0 0.0 720.0 6250.5 0.0 0.0 1747199 18827614 528950 6051920 503254 5830757 100.0 95.4 100.0 95.4 65.9 84.0 64.1
- 81. 7 0.0 4.6 Months (Type, Date,and Cumm.
138047.0 92640.0 0.0 89566.9 0.0 276415386 89805950 86502929 66.0 66.0 60.0 58.5 15.6 Duration):
25-If Shut Down At End of Report Period, Estimated Date of Startup:
- 26. Units in Test Status (Prior to Commercial Operation):
Forcast INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Achieved 9310200281 931006
'DR ADOCK'050003ih R
AVERAGE DAILY POWER LEVEL (MWe-Net)
DOCKET NO.
50-316 UNIT TWO DATE 04/Oct/93 COMPLETED BY DG TURNER TELEPHONE 616-465-5901 DAY MONTH AVERAGE DAILY POWER LEVEL SEPT 1993 DAY AVERAGE DAIL POWER LEVEL 09/01/93 09/02/93 09/03/93 09/04/93 09/05/93 09/06/93 09/07/93 09/08/93 09/09/93 09/10/93 09/11/93 09/12/93 09/13/93 09/14/93 09/15/93 09/16/93 695 682 685 675
. 680 691 692 684 675 654 503 499 516 691 743 738 09/17/93 09/18/93 09/19/93 09/20/93 09/21/93 09/22/93 09/23/93 09/24/93 09/25/93 09/26/93 09/27/93 09/28/93 09/29/93 09/30/93 740 737 740
" 737 735 739 739 761 762 769 761 753 748 748 0
UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH: SEPTEMBER 1993 UNIT NAME DATE:
COMPLETED BY:
TELEPHONE:
PAGE 1 OF 1 D. C.
COOK UNIT Oct. 8, 1993 R. D. Reynnells, (616) 465-5901 DURATION NO.
DATE TYPE HOURS METHOD OF SHUTTING LICENSEE DOWN EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION REASON REACTOR REPORT NO.
CODE CODE TO PREVENT RECURRENCE 232 930910 S
N/A N/A N/A N/A N/A The reactor power was reduced to ~
55%
RTP on 930910 to support the ~
application of a Clamtrol Treatment for zebra mussel control.
Forced Scheduled 2
Reasons A:
Equipment Failure (Explain)
B:
Maintenance or Test C:
Refueling D:
Regulatory Restriction E:
Operator Training and License Examination F:
Administrative G:
Operational Error (Explain)
H:
Other (Explain) 3 Method:
1:
Manual 2:
Manual Scram 3s Automatic Scram 4:
Other (Explain) 4Exhibit G Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 1061) 5Exhibit I:
Same Source
DOCKE 0--
UNIT NAME:
COMPLETED BY TELEPHONE:
DATE:
PAGE:
50-316 D.C.
Cook Unit 2 R.
D. Reynnells (616) 465-5901 Oct 8, 1993 Page 1 of 1 MONTHLY OPERATING ACTIVITIES SEPTEMBER 1993 HIGHLIGHTS The unit entered the reporting period in Mode 1 at 704 RTP.
On September 10, 1993 reacor power was reduced to 55% RTP to establish system conditions required to support "Clamtrol" treatment of circulation water and service water systems for zebra mussels.
Reactor power was returned to 754 RTP on September 14, 1993.
The unit exited this reporting period in Mode 1 at 75% RTP.
There were no challenges to the pressurizer safety valves or power operated relief valves.
Gross Electrical generation for the month of September was 528950 MWH.
DETAILS 09-10-93 09-11-93 09-14-93 2228 0045 0357 0950 Commenced reactor power decrease to 554 RTP to support Clamtrol Treatment for zebra mussel control.
Reactor power is at 554 RTP.
Commenced reactor power increase to 754 RTP.
Reactor power is at 75% RTP.
DOCKET NO:
UNIT NAME COMPLETED BY:
TELEPHONE:
DATE:
PAGE:
50-316 D.C.
Cook Unit 2 M. E. Russo (616) 465-5901 October 6,
1993 1 of 1 MAJOR SAFETY-RELATED MAINTENANCE Se tember 1993 No major safety-related maintenance items are included for the month of September.