Forwards LER 80-028/03L-0 & Updated LER 79-026/03X-1
Date released: 05/31/2018 Download: ML17331A407


Updated LER 79-026/03X-1:on 790709,while Reviewing Axial Power Distribution Monitoring Sys,Two Occasions Were Discovered in Which Only One Detector Scan Was Printed Out. Cause Undetermined.Investigation Closed
ML17331A409
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/29/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A409 (1)
LER 80-028/03L-0:on 800709,testing of Motor Driven Auxiliary Feedwater Pump During Blackout Conditions Showed Two Safety Injection Relay Timers Exceeded Tech Spec Allowed Tolerance.Caused by Instrument Drift
ML17331A408
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/29/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A408 (1)
Forwards LER 80-028/03L-0 & Updated LER 79-026/03X-1
ML17331A406
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/29/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A406 (2)