ML17331A337

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for May 1993 for DC Cook Nuclear Plant Unit 2
ML17331A337
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 05/31/1993
From: Reynnells R, Russo M, Doreen Turner
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
Shared Package
ML17331A336 List:
References
NUDOCS 9306170270
Download: ML17331A337 (6)


Text

N.R.C.

OPERATING DATA REPORT DOCKET NO.

50-316 DATE 04-Jun-93 COMPLETED BY DG Turner TELEPHONE 616-465-5901 OPERATING STATUS

1. Unit Name D.

C.

Cook Unit

2. Reporting Period May
3. Licensed Thermal Power (MWt) 4.

Name Plate Rating (Gross MWe)

5. Design Electrical Rating (Net MWe) 6.

Maximum Dependable Capacity (GROSS MWe) 7.

Maximum Dependable Capacity (Net MWe) 2 93 3411 1133 1090 1100 1060 notes

8. If Changes Occur in Capacity Ratings (Items no.

3 through

7) Since Last Report Give Reasons 9.

Power Level To Which Restricted. If Any (Net MWe) 10.

Reasons For Restrictions. If Any:

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23

'4.

Hours in Reporting Period No. of Hrs. Reactor Was Critical Reactor Reserve Shutdown Hours Hours Generator on Line Unit Reserve Shutdown Hours Gross Therm.

Energy Gen.

(MWH)

Gross Elect.

Energy Gen.

(MWH)

Net Elect.

Energy Gen.

(MWH)

Unit Service Factor Unit Availability Factor Unit Capacity Factor (MDC Net)

Unit Capacity Factor (DER Net)

Unit Forced Outage Rate Shutdowns Scheduled over Next Six none This Mo.

Yr. to Date 744.0 3623.0 744.0 3623.0 0.0 0.0 744.0 3623.0 0.0

~

0.0 2532586 12153561 829050 4003510 802017 3876520 100.0 100.0 100.0 100.0 101.7 100.9 98 '

98.2 0.0 0.0 Months (Type, Date,and Cumm.

135119.0 89980.5 0.0 86939.4 0.0 269741333 87757540 84548692 65.5 65.5 60.0 58.4 15.8 Duration):

25. If Shut Down At End of Report Period, Estimated Date of Startup:
26. Units in Test Status (Prior to Commercial Operation):

Forcast INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Achieved 9306170270 930607 PDR ADOCK 050003ih R

PDR

I~

~

I AVERAGE DAILY POWER LEVEL (MWe-Net)

DOCKET NO.

50-316 UNIT TWO DATE 02-Jun-93 COMPLETED BY DG Turner TELEPHONE 616-465-5901 DAY.

MONTH AVERAGE DAILY POWER LEVEL May 93 DAY AVERAGE DAILY POWER LEVEL 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 1082 1084 1085 1081 1082 1081 1086 1076 1083 1080 1079 1082 1081 1081 1078 1078 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1071 1081 1084 1076 1069 1075 1076 1085 1068 1070 1070 1074 1069 1077 1076

UNIT SHUTDOWNS AND POWER REDUCTIONS REPORT MONTH: MAY 1993 UNIT NAME:

DATE:

COMPLETED BY:

TELEPHONE:

D. C.

COOK UNIT 2 June 3, 1993 R. D. Reynnells (616) 465-5901 DURATION NO+

DATE TYPE HOURS METHOD OF SHUTTING DOWN REASON REACTOR LICENSEE EVENT SYSTEM COMPONENT CAUSE AND CORRECTIVE ACTION REPORT NO.

CODE CODES TO PREVENT RECURRENCE None There were no unit shutdown or significant power reductions from 100%

RTP this month.

1 F

S Forced Scheduled 2

Reason:

A:

Equipment Failure (Explain)

B:

Maintenance or Test C:

Refueling D:

Regulatory Restriction E:

Operator Training and License Examination F:

Administrative G:

Operational Error (Explain)

H:

Other (Explain) 3 Method:

1:

Manual 2:

Manual Scram 3:

Automatic Scram 4:

Other (Explain)

Exhibit G Instructions for preparation of data entry sheets for Licensee Event Report (LER) File (NUREG 1061) 5Exhibit I:

Same Source

~

~

I

~

DOCKET O.:

UNIT NAME:

COMPLETED BY:

TELEPHONE:

DATE PAGE 50-316 D.C.

Cook Unit 2 R.

D. Reynnells (616) 465-5901 June'3, 1993 Page 1 of 1 MONTHLY OPERATING ACTIVITIES Ma 1993 HIGHLIGHTS The unit entered the reporting period in Mode 1 at 1004 RTP.

The unit exited this reporting period in Mode 1 at 100% RTP.

There were no challenges to the pressurizer safety valves or power operated relief valves.

Gross Electrical generation for the month of May was 829050 MWH.

DETAILS None

DOCKET NO:

UNIT NAME:

COMPLETED BY:

TELEPHONE:

DATE:

PAGE'0-316 D.C.

Cook Unit 2 M. E. Russo (616) 465-5901 June 4,

1993 1 of 1

MAJOR SAFETY-RELATED MAINTENANCE Ma 1993 There were no major safety-related maintenance items during the month of May.