ML17331A156

From kanterella
Jump to navigation Jump to search
Forwards LERs 80-020/03L-0 & 80-021/03L-0
Date released: 05/31/2018 Download: ML17331A156


LER 80-021/03L-0:on 800429,while Performing Surveillance Test,Discovered Bistable for Steam Generator Water Level hi-hi Engineered Safety Feature Setpoint Exceeding Limit W/ Recurrence on 800430.Bistable Replaced & Calibr
ML17331A158
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 05/20/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A158 (2)
LER 80-020/03L-0:on 800421,during Normal Operation,Noticed Excessive Steam Line Differential Pressure Between Loops 1 & 2.Caused by Instrument Drift.Transmitter Calibr & Returned to Svc
ML17331A157
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 05/20/1980
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A157 (1)
Forwards LERs 80-020/03L-0 & 80-021/03L-0
ML17331A155
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 05/20/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References