Text
,~cess.zawmo 0>Sraramrow ozrvrOXSraxnox svgrzm g<<
REGULATC INFORMATION DISTRIBUTIONSTEM (RIDE)
ACCESSION NBR:9210140074 DOC.DATE: W~RI NOTARIZED: NO DOCKET FACIL:50-316 Donald C.
Cook Nuclear Power Plant, Unit 2, Indiana M
05000316 AUTH.NAME AUTHOR AFFILIATION TURNER,D.G.
BLIND,A.A.
RECIP.NAME RECIPIENT AFFILIATION
SUBJECT:
ly operating rept for Sept 1992 for DCP unit 2.N/
921005 tr.,
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES:
RECIPIENT ID CODE/NAME PD3-1 LA STANGFJ INTERNAL: AEOD/DOA NRR/D
/ PEB10 E
01 EXTERNAL: EGEiG BRYCEFJ.H NSIC COPIES LTTR ENCL 3
3 1
1 1
1 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME PD3-1 PD AEOD/DSP/TPAB NRR/DOEA/OEAB RGN3 NRC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 A
h
~
~ h ~
~
I ~
~ ~
~ ~ p '<<
<<<</
l <<<<
~ '
<</\\g h / Lh
~
~ h I<<<< ~
h ~ <<h<<IA h << ~ i
<<h
<<h h
<<-h<<g<<l R
D NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.
ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 14 ENCL 14
Indiana Michigan Power Company, ~
Cook Nuclear Plant~
One Cook Place Bridgman, Ml 49106 616 465 5901 October 5, 1992 U.S. Nuclear Regulatory Commission ATTN:
Document Control Desk Washington, D.C.
20555 Gentlemen:
Pursuant to the requirements of Donald C.
Cook Nuclear Plant Unit 2 Technical Specification 6.9.1.10, the attached Monthly Operating Report for the month of September 1992 is submitted.
Respectfully, A.A. Blind Plant Manager Attachment co NRC Region III D.R.
Hahn R.C. Callen S.
Hamming J.G.
Keppler INPO Records Center ANI Nuclear Engineering Department D.H. Williams, Jr.
E.E. Fitzpatrick R. L. Simms W.G. Smith, Jr.
D.A. Georgantis D.W. Paul S.H. Steinhart J.L. Leichner J.A.
Isom D.G. Turner E.A. Smarrella J.C. Krieger B.A. Svensson D.F. Krause E.C.
Schimmel i.aOOL5 92i0140074 920'F30, PDR"'DQCK 05000316
-'R'.
~.
N.R C.
OPERATING DATA REPORT DOCKET NO.
50-316 DATE 01-Oct-92 COMPLETED BY DG Turner TELEPHONE 616-465-5901 OPERATING STATUS
- 1. Unit Name D.
C.
Cook Unit 2
- 2. Reporting Period September 92
- 3. Licensed Thermal Power (MWt) 3411 4.
Name Plate Rating (Gross MWe) 1133
- 5. Design Electrical Rating (Net MWe) 1090 6.
Maximum Dependable Capacity (GROSS MWe) 1100 7.
Maximum Dependabl'e Capacity (Net MWe) 1060 notes
- 8. If Changes Occur in Capacity Ratings (Items no.
3 through 7) Since Last Report Give Reasons 9.
Power Level To Which Restricted.
Zf Any (Net MWe) 10.
Reasons For Restrictions.
Zf Any:
- 11. Hours in Reporting Period 12.
No. of Hrs. Reactor Was Critical
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator on Line
- 15. Unit Reserve Shutdown Hours
- 16. Gross Therm.
Energy Gen.
(MWH) 17.
Gross Elect.
Energy Gen.
(MWH)
- 18. Net Elect.
Energy Gen.
(MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (MDC Net)
- 22. Unit Capacity Factor (DER Net)
- 23. Unit Forced Outage Rate 24.
Shutdowns Scheduled over Next Six This Mo.
Yr.
720 0
218 '0.0 149 '
0 ~ 0 257569 66150 61300 20.8 20 '
8 '
7 '
79 '
Months (Type, to Date 6576.0 2412.4 0.0 1415.6 0.0 4029629 1229820 1181454 21.5 21.5 16.9 16.3 59.1 Date,and Cumm.
129288.0 85600.5 0.0 83015.7 0.0 256724262 83497970 80426326 65.4 65.4 59.7 58.1 14.8 Duration):
- 25. If Shut Down At End of Report Period, Estimated Date of Startup:
<i 921204
- 26. Units in Test Status (Prior to Commercial Operation):
Forcast INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Achieved
AVERAGE DAILY POWER LEVEL (MWe-Net)
DOCKET NO.
50-316 UNIT TWO DATE 01-Oct-92 COMPLETED BY DG Turner TELEPHONE 616-465-5901 MONTH September 92 DAY 1
2 3
4 5
6 7
8 9
10ll 12 13 14 15 16 AVERAGE DAILY POWER LEVEL 0
43 204 362 392 402 610 540 0
0 0
0 0
0 0
0 DAY 17 18 19 20 21 22 23 24 25 26 27 28 29-30 31 AVERAGE DAILY POWER LEVEL
UNIT SHVZDOWNS AND POWER REDUCZIONS REPORT MPH: S~~er 1992 DOCKS'O:
UNIT QME DATE CC5IPUKl93 BY:
TIKZHIONE:
50-316 D.C.
COOK UNIT 2 October 1, 1992 G.J. Costello (616) 465-5901 METHOD OF SHVITING LICENSEE IXJRATION DOWN EVENV SYSTEM CCMK5EVZ CAUSE AND CORRECTIVE ACTION TO NO.
DATE TYPE HOURS REASON REACIQR REPORT NO.
CODE CODe PREVENT RE'XXJRRENCE 224 920701 F
Cont'd 39.4 N/A N/A N/A
'lhe unit was shut dawn on 920701 to investigate the cause for the high ~
turbine generator vibrations.
Following extensive vibration analysis and balancing the generator was paralleled to the system grid at 1525 hours0.0177 days <br />0.424 hours <br />0.00252 weeks <br />5.802625e-4 months <br /> on 920902 to continue the vibration evaluation.
Total length of the outage was 1,510.3 hours3.472222e-5 days <br />8.333333e-4 hours <br />4.960317e-6 weeks <br />1.1415e-6 months <br />.
225 920908 F
531.0 N/A N/A N/A Due to the continued high main turbine generator vibrations during the reactor power increase, the unit was shutdown from 86. RZP.
The generator rotor has been removed and transported to the ABB facility in Richmond, Virginia for testing and repairs as required.
1 2
F:
Forced Reason:
S:
Scheduled A:
Equipment Failure (Explain)
B:
Maintenance or Test C:
Refueling D:
Regulatory Restriction E:
Operator Training and License Rumination F:
Administrative G:
Operational Error (Explain)
H:
Other (Explain) 3 Method:
1:
Manual 2:
Manual Scram 3:
Other (Explain) 4 5
Exhibit G Instructions Exhibit I:
Same Source for preparation of data entry sheets for Licensee Event Report (LER) File (NURIK 0161)
DOCKET NO:
UNIT NAME:
COMPLETED BY:
TELEPHONE:
DATE PAGE:
50-316 D.C.
Cook Unit 2 G.J. CostelloI (616) 465-5901 October 1,
1992 1 of 2 MONTHLY OPERATING ACTIVITIES SEPTEMBER 1992 HIGHLIGHTS The unit entered this reporting period in Mode 2 with the reactor critical and reactor power being maintained as required to support the turbine generator vibration evaluation and balancing efforts.
The turbine generator was paralleled to the grid on September 2 at 1525 followed by a reactor power increase to 29% RTP.
On September 4 the reactor power was increased to 49% RTP and stabilized for flux mapping.
On September 6 reactor power was increased to 70% RTP and stabilized for flux mapping.
On September 7 during a reactor power increased from 70% RTP, the reactor power increase was stopped at 86% RTP due to high main turbine generator vibrations.
In response to the high vibrations, a reactor power reduction was commenced.
At 84 RTP the main turbine generator was tripped.
To complete further evaluation of the main turbine generator vibrations, the generator rotor has been removed and transported to the ABB facility in Richmond, Virginia for testing and repairs as required.
The unit ended this reporting period in Mode 5, cold shutdown.
There were no challenges to the pressurizer safety valves or power operated relic'f valves.
Gross electrical generation for the month of September was 66150 MNH.
DETAILS 9-2-92 0330 1525 1605 1955 Entered Mode 1.
Turbine Generator paralleled to the grid.
Commenced reactor power increase.
Stabilized reactor power at, 29% power.
9-3-92 9-4-92 9-6-92 1612 1345 2000 Commence reactor power increase.
Stabilized reactor power at 49% power for flux mapping.
Commence reactor power increase.
DOCKET NO:
UNIT NAME:
COMPLETED BY:
TELEPHONE:
DATE PAGE 50-316 D.C.
Cook Unit 2 G.J. Costello (616) 465-5901 October 1,
1992 2 of 2 MONTHLY OPERATING ACTIVITIES SEPTEMBER 1992 9-7-92 1153 2155 9-8-92 1547 1613 1738 2010 2100 Stabilized reactor power at 704 for flux mapping.
Commence reactor power increase.
Stopped power increase at.
86% power due to increased main turbine generator vibrations.
Commence reactor power reduction.
Stabilized reactor power at 33% to evaluate main turbine generator vibrations.
Commence power decrease due to main turbine generator vibrations.
Stabilized reactor power at 84 and tripped the main turbine.
9-9-92 1543 1609 9-10-92 0205 9-17-92 2325 9-24-92 0339 Commenced reactor power reduction.
Entered Mode 2.
The RCS is in Mode 3.
The RCS is in Mode 4.
The RCS is in Mode 5.
~
~
DOCKET NO:
UNIT NAME:
COMPLETED BY:
TELEPHONE:
DATE:
PAGE:
50-316 D.C.
Cook Unit 2 E.C.