ML17329A618

From kanterella
Jump to navigation Jump to search
Provides Closeout Info for NRC Bulletin 89-001,Suppl 2, Failure of Westinghouse SG Tube Mechanical Plugs. All Affected Plugs,Required to Be Removed Prior to OL Expiration Removed During Cycle 12-13 Refueling Outage & Replaced
ML17329A618
Person / Time
Site: Cook 
Issue date: 09/21/1992
From: Fitzpatrick E
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
AEP:NRC:1096E, IEB-89-001, IEB-89-1, NUDOCS 9209300017
Download: ML17329A618 (3)


Text

ACCELERATED DI~

IBUTIONDEMONS ATION SYSTEM REGULATOR FORMATION DISTRIBUTION S EM ('RIDS) c~

A('CESSlON I BR:9209300017 DOC.DATE: 92/09/21 NOTARIZED: NO DOCKET PACIL:50-315 Donald C.

Cook Nuclear Power Plant, Unit 1,. Indiana M

05000315 AUTH.NAME AUTHOR AFFILIATION FITZPATRICK,E.

Indiana Michigan Power Co. (formerly Indiana a Michigan Ele RECIP.NAME RECIPIENT AFFILIATION MURLEYiT.E.

Document Control Branch (Document Control Desk)

SUBJECT:

Provides closeout info for NRC Bulletin 89-001,Suppl 2,

"Failure of Westinghouse SG Tube Mechanical Plugs." All R

affected plugs, required to be removed prior to OL expiration removed during Cycle 12-13 refueling outage a replaced.

I DISTRIBUTION CODE:

IE31D COPIES RECEIVED:LTR L ENCL N SIZE: +

D TITLE: Bulletin Response 89-01 re Failure of Westinghouse Steam Gen.

Mech.

T NOTES:

RECIPIENT ID CODE/NAME PD3-1 LA STANGEJ

%TERNAL: AEOD/DOA NRR/DET/EMEB 7E NRR/DOEA/OGCBll NRR DSTM EG FIL 0

RGN3 FILE 01 (TERNAL: NRC PDR COPIES LTTR ENCL 1

1 1

1 1

.1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/EMCB 9H NRR/DOEA/OEAB11 NRR/DREP/PEPB9D NRR/PMAS/ILRB12 RES/DSIR/EIB NSIC COPIES LTTR ENCL NOTE TO ALL RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

/

ZOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL

Indiana Michigan Power Company ~

P.O. Box 16631 ~

Coiumbus, OH 43216 INDlANA NllCHlGAN POMfER AEP:NRC:1096E Donald C.

Cook Nuclear Plant Unit 1 License No.

DPR-58 Docket No. 50-315 CLOSE OUT ACTION FOR NRC BULLETIN 89-01 SUPPLEMENT 2:

FAILURE OF WESTINGHOUSE STEAM GENERATOR TUBE MECHANICAL PLUGS U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555 Attn:

T.

E. Murley September 21, 1992

Dear Dr. Murley:

The purpose of this letter is to provide close-out information for NRC Bulletin 89-01 Supplement 2 "Failure of Westinghouse Steam Generator Tube Mechanical Plugs."

Our letter dated July 29, 1991 (AEP:NRCr1096C) provided our response to NRC Bulletin 89-01 Supplement 2.

In that letter, we committed to replacing all affected Inconel 600 mechanical plugs n Unit 1 prior to the plugs exceeding the effective full power day (EFPD) limits established by Westinghouse.

By this letter, we are informing you that all affected plugs that were required to be removed prior to expiration of the operating license were removed during the Unit 1 Cycle 12-13 refueling outage.

The affected p ugs were either replaced with Inconel 690 plugs or the tubes were recovered by sleeving.

Sincerely, ee;~<

E.

E. Fitzpatrick Uice President

<BAn.

9209300017 92092i PDR ADOCK 05000315 8

PDR Z'Eal

Dr. T. E. Murley AEP: NRC! 1096E ccrc D. H. Milliams, Jr.

A. A. Blind - Bridgman J.

R. Padgett C. Charnoff NFEM Section Chief A. B. Davis Region IXI NRC Resident Inspector - Bridgman