Text
ACCELERATED DIS UTION DEMONS ION SYSTEM F
/ REGULATORY 'INFORMATION DISTR1BUTION SYSTEM (RIDS)
ACCESSION NBR':9108050006 DOC.DATE: 91/07/26 NOTARIZED: NO DOCKET
..,FACIL:50-315'onald C.
Cook Nuclear Power Plant, Unit 1, Indiana 8
05000315 50+$ 16 Donald C.
Cook Nuclear Power Plant, Unit 2, Indiana 6
05000316
~'AUTH.NAKE AUTHOR AFFILIATION i FITZPATRICK,E.
(formerly Indiana
& Michigan Ele RECXP.NAME RECXPIENT AFFILIATION MORLEY,T.E.
Document Control Branch (Document Control Desk)~< Py.
SUBJECT:
Application for amends to Licenses DPR-58 6 DPR-74,changing Tech Specs to accomplish expansion of spent fuel pool storage capacity from 2,050 assemblies to 3F613 assemblies D
by replacing existing racks w/higher storage density racks.
S DISTRIBUTION CODE:
A001D COPIES RECEIVED:LTR J ENCL J SIZE: (k 3()
TXTLE: OR Submittal:
General Distribution
/
NOTES:
RECIPIENT ID CODE/NAME FD3-1 LA COLBURN,T.
~NTERNAL: NRR/DET/ECMB 7D NRR/DOEA/OTSB11 NRR/DST/SELB 7E NRR/DST/SRXB 8E OC/LFM XL 01 EXTERNAL'RC PDR COPIES LTTR ENCL 1
1 2
2 1
1 1
1 1
1 1
1 1
0 1
1 1
1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/ESGB NRR/DST 8E2 NRR/DST/SICB8H7 NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB NSIC COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 1
0 1
1 D
D R
D NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 18 ENCL 16 D
D S
Indiana Michigan Power Company P.O. Box 16631 Coiumbus, OH 43216 PH8MSlHSl NSClMECdlH PQWM AEP:NRC:1146 Donald C.
Cook Nuclear Plant Units 1 and 2
License Nos.
50-315 and 50-316 Docket Nos.
DPR-58 and DPR-74 SPENT FUEL POOL RERACKING TECHNICAL SPECIFICATION CHANGES U. S. Nuclear Regulatory Commission Document Control Desk Washington, D.
C.
20555 Attn:
T.
E. Murley July 26, 1991
Dear Dr. Murley:
This letter and it's attachments constitute an application for amendment of the license conditions and technical specifications (T/Ss) for the Donald C.
Cook Nuclear Plant Units 1
and 2.
Specifically, the changes proposed in this letter are intended to accomplish an expansion of the spent fuel pool storage capacity from 2050 assemblies to 3613 assemblies.
This willbe accomplished by replacing the existing racks with higher storage density racks, and by placing racks in areas of the pool where currently no racks exist.
With the present refueling outage
- schedule, we will lose storage space for a full core off-load (193 assemblies) in 1995.
This date could be as early as 1994 depending upon capacity factors achieved by the units'peration, and the necessity to store miscellaneous
- items, such as old thimble tubes, in storage cells in the spent fuel pool.
In order to allow continued operation of the units, we have determined that reracking the spent fuel pool is the best option available.
We currently plan to perform the reracking beginning in January 1993.
This falls prior to the Unit 2 and Unit 1 refueling outages currently scheduled for August 1993 and January
- 1994, respectively.
In order that this work can be properly planned and executed on a prudent
- schedule, we request your approval of these changes by January 31, 1992.
The changes 9i0805000'6 '9i0726: 7; PDR
=ADOCK 050003i5, P
Dr. T.
E. Murley AEP:NRC:1146 proposed in this letter,
- however, are such that implementation is not possible until the physical reracking occurs.
We, therefore, request that the proposed T/S changes become applicable upon initiation of the reracking of the spent fuel pool.
Attachment 1
provides a
detailed description of the proposed
- changes, the justification for the
- changes, and our proposed determination of no significant hazards consideration performed pursuant to 10 CFR 50.92.
Attachment 2 contains the existing T/S pages marked to reflect the proposed changes.
Attachment 3
contains the proposed T/S pages.
Attachment 4 contains a non-proprietary licensing report for the reracking project prepared by our contractor, Holtec International.
We believe
- that, the proposed changes will not result in a
significant change in the types of effluents or a significant increase in the amounts of any effluent that may be released offsite.
This is based on evaluations provided in the Holtec International (Holtec) report.
This conclusion is also supported by NUREG
- 0575, entitled "Final Generic Environmental Impact Statement on Handling and Storage of Spent Light Water Power Reactor Fuel."
In NUREG 0575 the NRC concluded that:
The storage of spent fuel in water pools is a well established technology, and under the static conditions of storage represents a low environmental impact and low potential risk to the health and safety of the public.
The Holtec report includes an estimate of the occupational exposure expected during the reracking.
This exposure is estimated to be in the range of 6 to 12 rem.
As discussed in the Holtec report, occupational exposure following the reracking is not expected to significantly increase.
The proposed changes have been reviewed by the Plant Nuclear Safety Review Committee and will be reviewed by the Nuclear Safety and Design Review Committee at its next regularly scheduled meeting.
In compliance with the requirements of 10 CFR 50.91(b)(1),
copies of this letter and its attachments have been transmitted to Mr. J.
R. Padgett of the Michigan Public Service Commission and to the Michigan Department of Public Health.
Dr. T.
E. Hurley AEP:NRC:1146 This document has been prepared following Corporate procedures that incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.
Sincerely, E.
E. Fitzpalrick Vice President eh Attachments cc:
D. H. Williams, Jr.
A. A. Blind - Bridgman J.
R. Padgett G. Charnoff NFEM Section Chief A. B. Davis - Region III NRC Resident Inspector
- Bridgman