ML17328A896

From kanterella
Jump to navigation Jump to search
Forwards Rept of Inservice Insps from 890317 Through 901109. Rept Summarizes Exams,Tests,Replacements & Repairs, Conditions Observed & Corrective Measures
ML17328A896
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 02/07/1991
From: Blind A
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML17328A897 List:
References
NUDOCS 9102130087
Download: ML17328A896 (6)


Text

ACCELERATED DI RIBUTION DEMONST TION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9102130087 DOC.DATE: 91/02/07 NOTARIZED:

NO

DOCKET, g

FACIL:50-316 Donald C.

Cook Nuclear Power Plant, Unit 2, Indiana 05000316 AUTH.NAME AUTHOR AFFILIATION BLIND,A.A.

Indiana Michigan Power Co. (formerly Indiana

& Michigan Ele RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

R

SUBJECT:

Forwards ISI NIS-1 Rept for Inservice Insp for Donald C.Cook I

Nuclear Power Plant Unit 2,re examinations, tests, replacement

& repairs performed.

D DISTRIECTION CODE:

A047 D COPIES RECEIVED: LTR /

ENCL Q SIZE: 2 'k254 S

TITLE: OR Submittal: Inservice Inspection/Testing/Relief from ASME Code NOTES: $~ g~f"~5 RECIPIENT ID CODE/NAME PD3-1 LA COLBURN,T.

INTERNAL: AEOD/DSP/TPAB

~

NRR/DET/EMEB 7E OC/L M FILE 01 EXTERNAL EG&G BROWN E B NRC PDR COPIES LTTR ENCL 1

0 2

2 1

1 1

1 1

0 1

1 1

1 1

1 RECIPIENT ID CODE/NAME PD3-1 PD NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS2 RES/DSIR/EIB EG&G RANSOME,C NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

0 1

1 1

1 1

A D

D S

It D

NOTE TO ALL"RIDS" RECIPIENTS:

D D

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAME FROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 16 ENCL 13

g h

~

~

I A

E

p

~

~

'v.

indiana Michigan ~

Power Company Cook Nuclear Plant One Cook Place Bridgrnan, Ml 49106 616 465 5901 Donald C.

Cook Nuclear Plant Unit 2 Docket No. 50-316 License No.

DPR-74 ISX NIS-1 REPORT U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Attn:

A. B. Davis February 7,

1991

Dear Mr. Davis:

Attached please find a copy of the XSX NIS-1 Report for Inservice Inspection activities performed at the Donald C.

Cook Nuclear Power Plant, Unit 2, State of Michigan, Number M-324232-M, located in Bridgman, Michigan.

The Plant is owned by Indiana Michigan Power Company,- One Summit Square, Ft.

Wayne, Xndiana 46802.

The unit's commercial service date is July 01, 1978 and has a

gross generating capacity of 1080 MWe.

The Authorized Code Inspector was Mr. M. K. Muterspaugh from Factory Mutual Engineering, whose address is 30150 Telegraph

Road, Bingham Office Park Suite 371, Birmingham, Michigan 48010.

The examinations,

tests, replacements and repairs performed, conditions observed, and corrective measures taken are summarized in the attached report.

ISI activities were performed in accordance with the rules and requirements of ASME Code Section XI 1983 Edition, Summer of 1983 Addenda.

Res cti A. Blind Plant Mana er D.

C. Cook Nuclear Plant cbm Attachment c:

See Attached Distribution I

9102130087 910207 PDR ADOCK 05000316 9

PDR

~ I

c:

D. H. Williams, Jr.

(w/o attachment)

R.

C. Callen (w/o attachment)

G. Charnoff (w/o attachment)

T. E. Murley (w/o attachment)

NRC Resident Inspector Bridgman (w/o attachment)

NFEM Section Chief (w/o attachment)

J.

E. Rutkowski (w/o attachment)

J.

B. Droste (w/o attachment)

D. E. van Deusen/C.

A. Freer (w/o attachment)

File

CP

~ 'e V

I N

P" l1 f

1.