ML17328A861
| ML17328A861 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 01/17/1991 |
| From: | Miller H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Alexich M INDIANA MICHIGAN POWER CO. |
| References | |
| NUDOCS 9101240055 | |
| Download: ML17328A861 (3) | |
Text
Docket Ho. 50-315 Docket Wo. 50-316 Indiana Michigan Power Company ATTN:
Mr. Milton P. Alexich Yice President Nuclear Operations Division
.1 Riverside Plaza Co lumbus, '8 43216 Gentlemen:
This notice confirms the discussion between Mr. J.
- Isom, Region III Senior Resident Inspector, and Mr. B. Lauzau of your staff, to have a meeting at 10:00 a.m. (CST)'n Friday, February 1,
1991, at the Region III office in Glen Ellyn, Illinois.
-The purpose of this meeting is to discuss the Unit 1 outage and lessons learned;
- status, findings, and root cause determination relative to the Unit 2 RHR heat exchanger seismic support investigation; IE Bulletin 79-14 reverification program; and ESl~ SSFI fol,lowup.
lie will gladly discuss any questions you may have regarding this matter.
S incere ly, cc:
A. A. Blind, Plant Manager DCD/DCB (RIDS)
OC/LFDCB Resident Inspector, RIII James R. Padgett, Michigan Public Service Commission EIS Coordinator, USEPA Region 5 Office Michigan Department of Public Health D.
C.
- Cook, LPM, NRR Hubert J. Miller, Director Division of Reactor Projects ter/bs rgensen H
9l Pi0i240055 9iOi17 PDR ADOCK 050003i5 P
PDR j'Vr RIII RIII Yes RIII C 1 ayton y'(7/P ~
RIII Martin RIII Nggju s
NUCLEAR REGULATORY COIVIMISSION REGION III 799 ROOSEVELT ROAO GLLN LLLYNs ILLINOIS 60197 Docket f{o. 50-315 Docket No. 50-316 Indiana Michigan Power. Company ATTN:
Mr." Milton P.'lexich Vice President t{uclear Operations Division 1 Riverside Plaza
- Columbus, Of{
43216 Gentlemen:
This notice confirms the discussion between Mr. J.
- Isom, Region III Senior Resident Inspector, and {1r. B. Lauzau of your staff, to have a meeting at 10:00 a.m.
(CST) on Friday, February 1, 1991, at the Region III office in Glen Ellyn, Illinois.
The purpose of this meeting is to discuss the Unit 1
outage and lessons learned;
- status, findings, and root cause determination relative to the Unit 2 RHR heat exchanger seismic support investigation; IE Bulletin 79-14 reverification program; and ESH SSFI followup.
h'e Mill gladly discuss any questions you may have regarding this matter.
S incere ly, cc:
A; A. Blind, Plant MIanager DCD/DCB (RIDS)
OC/LFDCB Resident Inspector, RIII James R. Padgett, f{ichigan Public Service Commission EIS Coordinator, USEPA Region 5 Office Michigan Department of Public Health D.
C.
- Cook, LP{1, NRR Hu ert J. Miller, Director Division of Reactor Projects
0