ML17326B308

From kanterella
Jump to navigation Jump to search
Forwards Final Seismic Analysis Rept, Crane Seismic Rept, Cask Handling Crane,150/20 Ton Capacity,S/N 12115, Vols I & Ii.Analysis for New Auxiliary Bldg Crane to Meet single- failure-proof Requirements of NUREG-0554
ML17326B308
Person / Time
Site: Cook  
Issue date: 01/12/1988
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Murley T
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17326B309 List:
References
RTR-NUREG-0554, RTR-NUREG-554 AEP:NRC:0980H, AEP:NRC:980H, NUDOCS 8801150245
Download: ML17326B308 (5)


Text

REGULAT INFORMATION DISTRIBUTION, STEM

( RIDS >

ACCESSION NBR: 8801150245 DOC. DATE: 88/Oi/12 NOTARIZED: NO'-

DOCKET 0 FACIL: 50-3ih Donald C.

Cook Nuclear Power Planti Unit 21 indiana 05000316 AUTH. NAME AUTHOR AFFILIATION ALEXICH1M.P.:

Indiana Michigan Power Co.

(formerly Indiana 5 Michigan Ele RECIP. NAME

'ECIPIENT AFFILIATION Document Control Branch (Document Control Desk)

SUBJECT:

Foreards final seismic analysis rept, "Crane Seismic Rept'ask Handling Cranei 150/20 Ton Capacitgi S/N 121151 " Vols I II.Analysis for neuj auxiliary bldg, crane to meet single-F a 1 1 ure-pr oo f rendu irement s o F NUREG-0554.

5+8 DISTRIBUTION CODE:

A0010 COPIES RECEIVED: LTR J ENCL J SIZE:

TITLE:

OR Submittal:

General Distribution NOTES:

REC IP lENT ID CODE/NAME PD3-3 LA WIGGINGTON> D.

INTERNAL:'RM/DAF/LFMB NRR/DEST/CEB NRR/DEST/RSB N

S/ILRB R GFIL 01 EXTERNAL:

LPDR NSIC COPIES LTTR ENCL 1

1 +

1 +

1 1 ~.

RECIPIENT ID CODE/NAME PD3-3 PD NRR/DEST/ADS NRR/DEST/MTB NRR/DOEA/TSB OGC/HDS1 RES/DE/EIB NRC PDR COPIES LTTR ENCL Sm TOTAL NUMBER OF COPIES REQUIRED:

LTTR 20 ENCL

0 t

Indiana Michigan Power Company P.O. Box 16631 Columbus, OH 43216 AEP:NRC:0980H Donald C.

Cook Nuclear Plant Unit 2 Docket No. 50-316 License No.

DPR-74 NEW AUXILIARY'BUILDINGCRANE FINAL SEISMIC ANALYSIS=REPORT U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555 ATTN:

T.

E. Murley Pqnuqry 3.2 3.988

Dear Dr. Murley:

Enclosed, as requested by your staff, is one copy of the final seismic analysis report entitled, "Crane Seismic Report, Cask Handling Crane, 150/20 Ton Capacity, S/N 12115," Volumes I and II dated September 9,

1987, performed by Whiting Corporation.

This analysis is for the new auxiliary building crane being built to meet the single-failure-proof requirements of NUREG-0554.

This final seismic analysis, which confirms the conclusions of the preliminary seismic analysis provided in Supplement 1 of the Steam Generator Repair Report, demonstrates that the allowable stresses of the principal structural components of the new crane are not exceeded during a design-basis earthquake with a 60 ton load on the main hook.

eSO11SOa~S SeOiaa ~

PDR ADOCN, 0500031'b p

PDR

T.

E. Murley AEP'NRC:0980H This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Sincerely,

~ Alex ch Vice President lp cc:

John E. Dolan W.

G. Smith, Jr.

- Bridgman R.

C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector

- Bridgman

- w/attachments A. B. Davis

- Region III-w/attachments

1 1