Text
REGULATORY FORMATION DISTRIBUTION SY EN (RIDS)
ACCESSION 'BR;8407310371 DOC G DATE: 84/07/27 NOTARIZED:
NO DOCKET FACIL,'50-316 Donal d C ~
Cook Nucl ear Power Pl anti Uni t 2i Indiana L
05000316 kUTH,NAME AUTHOR AFFILIATION CHANDLERiJGC.
Exxon Nuclear Co,i Inc, (subs, of Exxon Corp,)
RECIP ~ NAME RECIPIENT AFFILIATION DENTONiH ERG Office of Nuclear Reactor Regulationi Director
SUBJECT:
Forwards proprietary Rev 2'o XN NF 84",21 (P)i "DC Cook Unit 2iCycle 5 5/,Steam 'Generator Tube Plugging Limiting Break LOCA/ECCS Analysisi" per American E'lectric Power Svc Co request, Rept withheld (ref 10CFR2G790)
~
~egye1.ag ~ 'PGL~d Fu~
DISTRIBUTION CODE:
PA01S +CQPIES RECEIVED:LTR ENCL fJ, SIZE! L> "~Q?
TITLE: Proprietary Review Distribution Operating Reactor NOTES:
OL: 12/23/72 05000316 RECIPIENT COPIES ID CODE/NAtlE LTTR ENCL NRR ORB1 BC
+g>>
7 7
INTERNALS ELD/HDS3 1
0 RGNB g f 1
1 EXTERNAL: ACRS I~yN uk 17 NRC PDR 1
0 RECIPIENT ID CODE/NAYiE R~GF 1LB LPDR NTIS COPIES LTTR ENCL 1
1 1
0 1
0.
g f'Ir'O CIF ~
Q
- b. Ikl'Ijq'iiig~OIV l,P,~~) 4/0 +hip APE TOTAL'UMBER OF COPIES REQUIRED:
LTTR'9 ENCL 15
~
I(
\\
~
lr I
~
h a
II t
1I N
E)f(ON NUCLEAR COMPANY,Inc.
2101 Hom Bapida Road P. 0 Box 13/ Richland, 8'aa/iington gg352 Phone: (509) 375-8100 Telex: 15-2878 July, 27, 1984 JCC:106:84 Donald C.
Cook Nuclear Plant Unit No.
2 Docket No. 50-316 License No.
DPR-74 SUPPORTING DOCUMENTATION FOR UNIT 2 TECHNICAL SPECIFICATION CHANGES FOR CYCLE 5
RELOAD Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission
- Bethesda, MD 20014 Ref.:
- Letter, J.C.
Chandler (ENC) to H.R.
Denton (USNRC),
"Supporting Documentation for Unit 2 Technical Specification Changes for cycle 5 Reload,"
(JCC:040:84),
dated March 2, 1984.
Dear Mr. Denton:
Enclosed are forty-one copies of Revision 2 to XN-NF-84-21(P),
"Donald C.
Cook Unit 2
Cycle 5
5X Steam Generator Tube Plugging Limiting Break LOCA/ECCS Analysis."
At the request of American Electric Power Service Company (AEPSC), this report is being transmitted directly by Exxon Nuclear.
Exxon Nuclear Company considers information contained in the enclosed report to be proprietary.
In accordance with the Commission 's Regulation 10 CFR 2.790(b),
the Affidavit enclosed with the reference letter provides the necessary information to support the withholding of this response from public dis closure.
G.
If you have any questions about this submission, please contact Mr. James Feinstein of AEPSC at (614) 223-2040.
Sincerely, naa cc:
Mr. D. L. Nigginton (USNRC)
Mr. M. P. Alexich (AEPSC)
'~ora~oavs 840>ai PDR ADOCK 050003kb P
POR J.
C. Chandler, Lead Engineer Reload Fuel Licensing 0(s)
ANAFFILIATEOF EXXONCORPORATION
4 A,
II 4