ML17326A863

From kanterella
Jump to navigation Jump to search
Forwards LER 81-007/03L-0
Date released: 01/01/2020 Download: ML17326A863


Forwards LER 81-007/03L-0
ML19352A291
Person / Time
Site: Cook 
Issue date: 04/10/1981
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19352A291 (1)
LER 81-007/03L-0:on 810318,loop 2 T-average & delta-T Indicated Low Temps.Caused by Resistance Temp Detector Producing Erroneous Temp Readings.Detector Replaced & Trip Setpoints Verified
ML17326A862
Person / Time
Site: Cook 
Issue date: 04/10/1981
From: Rischling J
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A862 (6)