ML17326A796

From kanterella
Jump to navigation Jump to search
Forwards LER 80-026/03L-0
Date released: 05/31/2018 Download: ML17326A796


LER 80-026/03L-0:on 801113,glycol Return Containment Isolation Valve Failed to Close During Surveillance Test & During Investigation.Caused by Stem & Lower Guide Bush Sticking.Stem Polished & Bushed Honed
ML17331A249
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/12/1980
From: Wizner D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A249 (4)
Forwards LER 80-026/03L-0
ML17326A795
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 12/12/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A795 (2)