ML17326A704

From kanterella
Jump to navigation Jump to search
Forwards LER 80-015/03L-0
Date released: 05/31/2018 Download: ML17326A704


LER 80-015/03L-0:on 800703,in Mode 6,train B Centrifugal Charging Pump Failed While Running Due to Broken Pump Shaft. Cause Unknown.Pump Rebuilt Using New Design Shaft
ML17331A411
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/29/1980
From: Lease R
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17331A411 (4)
Forwards LER 80-015/03L-0
ML17326A703
Person / Time
Site: Cook American Electric Power icon.png
Issue date: 07/29/1980
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17326A703 (2)