Notice of Consideration of Issuance of Amend to Licenses DPR-58 & DPR-74 & Proposed NSHC Determination Opportunity for Hearing.Amend Changes Runout for SI Pump to 675 Gallons Per Minute,Not Exceeding 700 Gallons Per Minute
ML17326A105
Person / Time
Site: Cook  
Issue date: 08/25/1999
From: Stang J
NRC (Affiliation Not Assigned)
To:
Shared Package
ML17326A104 List:
References
NUDOCS 9908310302
Download: ML17326A105 (11)


Text

7590-01-P UNITED STATES NUCLEAR REGULATORYCOMMISSION INDIANAMICHIGANPOWER COMPANY DOCKET NOS. 50-315 AND50-316 NOTICE OF CONSIDERATION OF ISSUANCE OF AMENDMENTTO FACILITYOPERATING LICENSE PROPOSED NO SIGNIFICANTHAZARDS CONSIDERATION DETERMINATION AND OPPORTUNITY FOR A HEARING The U.S. Nuclear Regulatory Commission (the Commission) is considering issuance of amendments to Facility Operating License Nos. DPR-58 and DPR-74 issued to Indiana Michigan Power Company (the licensee) for operation of the Donald C. Cook Nuclear Power Plant, Units 1 and 2, located in Berrien County, Michigan.

The proposed amendments would change the runout limits for a safety injection (Sl) pump to 675 gallons per minute (gpm), unless the pump is specifically tested to a higher flow rate, not exceeding 700 gpm for both Units 1 'and 2. This change was initiated upon reevaluation of correspondence from Westinghouse sent to the licensee in 1991, which indicated that the generic runout limits for Pacific 2" JTCH pumps was 675 gpm unless each specific pump is tested to a higher flow rate.

Individual testing is necessary due to test variations between pumps which may limitthe applicability of testing of one pump to another pump due to manufacturing toferances in the sand cast impellers and material changes in the pump casing.

Furthermore, the bases section is being clarified to describe why the injection rather than the recirculation mode during flow balancing is the minimum resistance and, consequently, more conservative configuration for.runout considerations.

9908310302 990825 PDR ADQCK 050003i5 P

PDR

Before issuance of the proposed license amendment, the Commission willhave made findings required by the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations.

~ The Commission has made a proposed determination that the amendment request involves no significant hazards consideration.

Under the Commission's regulations in 10 CFR

'0.92, this means that operation of the facilityin accordance with the proposed amendment would

.=
;.;:;.solve a significant increase in the probability or consequences of an accident previously evaluated; or (2) create the possibility of a new or different kind of accident from any accident previously evaluated; or (3) involve a significant reduction in a margin of safety.

As required by 10 CFR 50,91(a), the licensee has provided its analysis of the issue of no significant hazards consideration, which is presented below:

In accordance with 10 CFR 50.92, this proposed amendment does not involve a significant hazard consideration if it does not:

1.

Involve a significant increase in the probability or consequences of an accident previously evaluated.

The proposed reduction in the SI pump runout flow does not increase the probability of occurrence of any previously evaluated accident because the Sl pumps are not considered.to be accident initiators.

In addition, flow balancing performed at Cook Nuclear Plant has proven the ability to deliver the minimum T/S flow of 300 gpm to each pair of cold leg injection points without exceeding the 675 gpm (or 700 gpm) pump runout limits. Therefore, the emergency core cooling system performance objectives of 10 CFR 50.46 are not impacted and this change does not involve a significant increase in the consequences of an accident previously evaluated.

2.

Create the possibility of a new or different kind of accident from any accident previously evaluated.

This proposed change imposes a generic limiton maximum allowable flowfor untested Sl pumps.

No physical system changes or changes in operating modes are being made that could introduce new or different kinds of accidents from those preViously evaluated.

As discussed in (1) above, the Sl pumps are not considered accident initiators, and this status is not affected by the change to the Sl pump runout limits.

3.

Involve a significant reduction in a margin of safety.

/

This change reflects a reduced maximum single pump flowto be observed during flow balancing of the Sl system.

Flow balance testing at Cook Nuclear Plant has demonstrated the ability to meet the Sl flow requirements while maintaining an adequate margin to the revised tower runout limits being proposed by this submittal.

Because the minimum required Sl flowdelivered to the core has not been reduced by this change, the change does not'involve a reduction in a margin of safety.

Based on the preceding, the evaluation concluded that the proposed change to the Sl pump runout limits does not involve a significant hazards consideration as defined in 10 CFR 50.92.

The NRC staff has reviewed the licensee's analysis and, based on this review, it appears that the three standards of 10 CFR 50.92 are satisfied. Therefore, the NRC staff proposes to determine that the amendment request involves no significant hazards consideration, The Commission is seeking public comments on this proposed determination.

Any comments received within 30 days after the date of publication of this notice willbe considered in making any final determination.

Normally, the Commission willnot issue the amendment until the expiration of the 30-day notice period.

However, should circumstances change during the notice period such that failure to act in a timely way would result, for example, in derating or shutdown of the facility, the Commission may issue the license amendment. before the expiration of the 30-day notice period,

'I provided that its final determination is that the amendment involves no significant hazards consideration.

The final determination willconsider all public and State comments received.

Should the Commission take this action, it willpublish in the FEDERAL REGISTER a notice of issuance and provide for opportunity for a hearing after issuance.

The Commission expects that the need to take this action willoccur very infrequently.

Written comments may be submitted by mail to the Chief, Rules and Directives Branch, Division of Administrative Services, Office of Administration, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, and should cite the publication date and page

number of this FEDERAL REGISTER notice. Written comments may also be delivered to Room 6D59, Two White Flint North, 11545 Rockville Pike, Rockville, Maryland, from 7:30 a.m. to 4:15 p.m. Federal workdays.

Copies of written comments received may be examined at the NRC Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC.

The filingof requests for hearing and petitions for leave to intervene is discussed below.

By September 30, 1999, the licensee may file a request for a hearing with respect to issuance of the amendment to the subject facilityoperating license and any person whose interest may be affected by this proceeding and who wishes to participate as a party in the proceeding must file a written request for a hearing and a petition for leave to intervene.

Requests for a hearing and a petition for leave to intervene shall be filed in accordance with the Commission's "Rules of Practice for Domestic Licensing Proceedings'n 10 CFR Part 2. Interested persons should consult a current copy of 10 CFR 2.714 which is available at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC, 'and at the local public document room located at the Maud Preston Palenske Memorial Libraiy, 500 Market Street, St. Joseph, Ml 49085.

If a request for a hearing or petition for leave to intervene is filed by the above date, the Commission or an Atomic Safety and Licensing Board, designated by the Commission or by the Chairman of the Atomic Safety and Licensing Board Panel, will rule on the request and/or petition; and the Secretary or the designated Atomic Safety and Licensing Board willissue a notice of hearing or an appropriate order.

As required by 10 CFR 2.714, a petition for leave to intervene shall set forth with particularity the interest of the petitioner in the proceeding, and how,that interest may be affected by the results of;the proceeding.

The petition should specifically explain the reasons why intervention should be permitted with particular reference to the following factors; (1) the nature of the petitioner's right under the Act to be made party to the proceeding; (2) the nature and extent of the petitioner's property, financial, or other interest in the proceeding; and (3) the possible effect of

0

any order which may be entered in the proceeding on the petitioner's interest. The petition should also identify the specific'aspect(s) of the subject matter of the proceeding as to which petitioner wishes to intervene.

Any person who has filed a petition for leave to intervene or who has been admitted as a party may amend the petition wit)out requesting leave of the Board up to 15 days prior to the first prehearing conference scheduled in the proceeding, but such an amended petition must satisfy the specificity requirements described above.

Not later than 15 days prior to the first prehearing conference scheduled in the proceeding, a petitioner shall file a supplement to the petition to intervene which must include a list of the contentions which are sought to be litigated in the matter.

Each contention must consist of a specific statement of the issue of law or fact to be raised or controverted.

In addition, the petitioner shall provide a brief explanation of the bases of the contention and a concise statement of the alleged facts or expert opinion which support the contention and on which the petitioner intends to rely in proving the contention at the hearing. The petitioner must also provide T

references to those specific sources and documents of which the petitioner is aware and on which the petitioner intends to rely to establish those facts or expert opinion, Petitioner must provide sufficient information to show that a genuine dispute exists with the applicant on a material issue of law or fact. Contentions shall be limited to matters within the scope of the amendment under consideration.

The contention must be one which, if proven, would entitle the petitioner to relief.

A petitioner who fails to file such a supplement which satisfies these requirements with respect to at least one contention willnot be permitted to participate as a party.

Those permitted to intervene become parties to the proceeding, subject to any limitations in the order granting leave to intervene, and have the opportunity to participate fullyin the conduct of the hearing, including the opportunity to present evidence and cross-examine witnesses.

(

6 If a hearing is requested, the Commission willmake a final determination on the issue of no significant hazards consideration.

The final determination willserve to decide when the hearing is held.

Ifthe final determination is that the amendment request involves no significant hazards consideration, the Commission may issue the amendment and make it immediately effective, notwithstanding the request for a hearing. Any hearing held would take place after issuance of tne amendment.

If the final determination is that the amendment request involves a significant hazards consideration, any hearing held would take place before the issuance of any amendment.

A request for a hearing or a petition for leave to intervene must be filed with the Secretary of the Commission, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, Attention: Rulemakings and'Adjudications Staff, or may be delivered to the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC, by the above date.

A copy of the petition should also be sent to the Office of the General Counsel, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, and to Jeremy J. Euto, Esquire, 500 Circle Drive, Buchanan, Ml 49107, attorney for the licensee.

Nontimely filings of petitions for leave to intervene, amended petitions, supplemental petitions and/or requests for hearing willnot be entertained absent a determination by the Commission, the presiding officer or the presiding Atomic Safety and Licensing Board that the petition and/or request should be granted based upon a balancing of the factors specified in 10 CFR 2.714(a)(1)(l)-(v) and 2,714(d).

For further details with respect to this action, see the application for amendment dated May 21, 1999, which is available for public inspection at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC, and at the local public

1 For further details with respect to this action, see the application for amendment dated May 21, 1999, which is available for public inspection at the Commission's Public Document Room, the Gelman Building, 2120 L Street, NW., Washington, DC, and at the local public.document room located at the Maud Preston Palenske Memorial Library, 500 Market Street, St. Joseph, Ml49085.

Dated at Rockville, Maryland, this 25th day ofAugust 1999.

FOR THE NUCLEAR REGULATORYCOMMISSION hn F. Stang,

. Project Manager, Section 1

Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation