ML17325B353
| ML17325B353 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 11/21/1989 |
| From: | Thoma J Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML17325B354 | List: |
| References | |
| NUDOCS 8912060162 | |
| Download: ML17325B353 (14) | |
Text
pe REGS~
0 o 4'-
)fp*y4 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 INDIANA MICHIGAN POWER COMPANY DOCKET NO. 50-315 DONALD C.
COOK NUCLEAR PLANT UNIT NO.
1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 129 License No.
DPR-58 The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Indiana Michigan Power Company (the licensee) dated January 27,
- 1989, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and.safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this, amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
89'i2060162 SPii2l l
PDR ADOCK 050003l5 P
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph
- 2. C.(2) of Facility Operating License No.
DPR-58 is hereby amended to read as follows:
Technical S ecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 129
, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical Specifications Date of Issuance:
November 21, 1989 Jo n 0.
Thoma, Acting Director Project Directorate III-1 Division of Reactor Projects - III, IV, V & Special Projects Office of Nuclear Reactor Regulation
ATTACHMENT TO LICENSE AMENDMENT NO. 129 FACILITY OPERATING LICENSE NO.
DPR-58 DOCKET NO.
50-315 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.
The revised pages are identified by amendment number and contain marginal lines indicating the area of change.
REMOVE 3/4 3-63 3/4 3-64 3/4 3-66 3/4 3-67 INSERT 3/4 3-63 3/4 3"64 3/4 3-66 3/4 3-67
TABLE 3.3-13 Rad oactive Gaseous Eff uent Monitor n Instrume tatio instrument Instrument 1.
Paste Gas Holdup 5'stem Explosive Gas Mon'=oring System a.
Hydrogen Monitor :.'QC-31) b.
Oxygen Monitor (QC-3'.
QC-370)
Minimum Channels
~Oe able (1)
(2) acTzow 30 29 2.
Condenser Evacuation System a.
Noble Gas Activity Monitor (SRA-1905) b.
Flow Rate Monitor (SFR-401)
(1-MR-054 and/or SRA-1910)
(1)
(1)
(1) 28 27 27 3.
Unit Vent, Auxiliary Building Ventilation System a.
Noble Gas Activitv Monitor (VRS-1505)
- b. Iodine Sampler Cartridge for VRS-1503
- c. Particulate Sampler Filter for VRS-1501
- d. Effluent System Flow Rate Measuring Device (VFR-315)
(1-MR-054 and/or VRS-1510) e.
Sampler Flow Rate Measuring Device (VFS-1521) 28 32 32 27 27 27 Containment Purge System a.
Aux. Building Vent.
System Noble Gas Activitv Monitor (VRS-1505)
- b. Aux. Building Vent.
System Particulate Sampler for VRS-1501 5.
Waste Gas Holdup System a.
Noble Gas Activity Monitor Providing Alarm and Termination of Gas Decay Tank Releases (VRS-1505) 6.
Gland Seal Exhaust a.
Noble Gas Activity Monitor (SRA-1805) b.
Flow Rate Monitor (SFR-201)
(1-MR-054 and/or SRA 1810)
D.
C.
COOK
- UNIT 1 (1)
(1)
(1) 3/4 3-63 31 32 33 28 27 27 Amendment No. 852
TABLE 3.3-13 (Cont.)
At all times During waste gas holdup system operation (treatment for primary system gases)
- ~**During releases via. this pathway.
For purge purposes
- only, see Technical Specifications 3.3.3.10, Table 3.3-13 and Table 4.3-9 (Items 3.a, 5.a in both tables) for non-purging requirements associated with this instrument.
2 For gas decay tank releases
- only, see Item 3 (Unit Vent, Auxiliary Building Ventilation System) for additional requirements.
3The waste gas holdup system explosive gas monitoring system may be inoperable for up to 160 days on a one-time basis for the purpose of replacing one hydrogen and one oxygen monitor.
During this time grab samples for both hydrogen and oxygen are to be taken and analyzed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
COOK NUCLEAR PLANT - UNIT 1 3/4 3-64 AMENDMENT NO. gg, 129
TABLE 4.3-9 active Gaseous E
ue t on to Surveillance Re ui.
erne ts at o
Inst ume t nstrument
=)
CHANNEL CHECK CHANNEL SOURCE
- CHANNEL, FUNCTIONAL CHECK CALIBRATION TEST 1.
Waste Gas Holdup System Explosive Gas Monitoring System
- a. Hydrogen****
Monitor (QC-31)
- b. Oxygen****
Monitor (QC-31) c.
Oxygen Monitor (Alt.,QC-370)
NA NA NA Q(3)
Q(4)
Q(4) 2.
Condenser Evacuation System a.
Noble Gas Activity Monitor (SRA-1905) b.
System Effluent Flow Rate (SFR-401, 1-MR-054, SRA-1910)
Dx*
NA R(2)
Q(1)
- 3. Auxiliary Building Ventilation System a.
Noble Gas Activity Monitor (VRS-1505)
- b. Iodine Sampler (For VRS-1503)
- c. Particulate Sampler (For VRS-1501) d.
System Effluent Flow Rate Measurement Device (VFR-315, 1 -MR-054, VRS e.
Sampler Flow Rate Measurement Device (VFS-1521)
-1510)
D*
NA NA NA NA R(2)
NA NA Q(l)
NA
- 4. Containment Purge System
- a. Aux. Building Vent.
System Noble Gas Activity Monitor (VRS-1505)
- b. Aux. Building Vent.
System Particulate Sampler (For VRS-1501) 5.
Waste Gas Holdup System a.
Noble Gas Activity Monitor Providing Alarm & Termination of Gas Decay Tank Releases (VRS-1505)
D**
R(2)
NA R(2)
Q(1)
NA Q(5)
D.
C.
COOK - UNIT 1 3g4 3-66 Amendment No. pp, 129
TABLE 4.3-9 (Cont)
Instrument Instrument
"-4 CHANNEL CHANNEL SOURCE CHANNEL FUNCTIONAL I'HECK
~CHEC CALIBHATTON TEST
- 6. Gland Seal Exhaust a.
Noble Gas Activity (SRA-1805) b.
System Effluent Flow Rate (SFR-201, 1-HR-054.
SRA-1810)
NA R(2)
Q(i)
At all times
~*
During release via this pathway
~** During waste gas holdup system operation (treatment for primary system offgases)
- These surveillances are not required during the 160-day period in which this monitor is being replaced.
D.
CD COOK - UNIT 1 3/4 3-67 Amendment No. g4, 129
~pS IlE0y
,+4 I
i~
0o
+y
~0
>>a*<<+
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 INDIANA MICHIGAN POWER COMPANY DOCKET NO. 50-316 DONALD C.
COOK NUCLEAR PLANT UNIT NO.
2 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 114 License No.
DPR-74 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Indiana Michigan Power Company (the licensee) dated January 27, 1989, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment wi 11 not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No.
DPR-74 is hereby amended to read as follows:
Technical S ecifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.
114
, are hereby incorporated
.in the license.
The licensee shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance.
FOR THE NUCLEAR REGULATORY COMMISSION
Attachment:
Changes to the Technical Specifications John 0.
Thoma, Acting Director Project Directorate III-1 Division of Reactor Projects
- III, IV, V 8 Special Projects Office of Nuclear Reactor Regulation Date of Issuance:
November 21, 1989
ATTACHMENT TO LICENSE AMENDMENT NO ~ 114 FACILITY OPERATING LICENSE NO.
DPR-74 DOCKET NO. 50-316 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.
The revised pages are identified by amendment number and contain marginal lines indicating the area of change.
REMOVE 3/4 3-59 3/4 3-60 3/4 3-62 3/4 3-63 INSERT 3/4 3-59 3/4 3-60
'/4 3-62 3/4 3-63
TABLE 3.3-13 Radioactive Gaseous E fluent Mon torin Instrume tat o
Instrument Instrument a
Minimum Channels
~Oerab e
1icab it
~CTION 1.
Waste Gas Holdup System Explosive Gas Monitoring System a.
Hydrogen Monitor (QC-31) b.
Oxygen Monitor (QC-31, QC-370)
(1)
(2) 30 29 2.
Condenser Evacuation System a.
Noble Gas Activity Monitor (SRA-2905) b.
Flow Rate Monitor (SFR-401)
(2-MR-054 and/or SRA-2910)
(1)
(1)
(1) 28 27 27 3.
Unit Vent, Auxiliary Building Ventilation System a.
Noble Gas Activity Monitor (VRS-2505)
- b. Iodine.Sampler Cartridge for VRS-2503
- c. Particulate Sampler Filter for VRS-2501
- d. Effluent System Flow Rate Measuring Device (VFR-315)
(2-MR-054 and/or VRS-2510) e.
Sampler Flow Rate Measuring Device (VFS-2521) 28 32 32 27 27 27 Containment Purge System
- a. Aux. Building Vent.
System Noble Gas Activity Monitor (VRS-2505)
- b. Aux. Building Vent.
System Particulate Sampler for VRS-2501
- 4+
31 32 5.
Waste Gas Holdup System
- a. Noble Gas Activity Monitor Providing Alarm and Termination of Gas Decay Tank Releases (VRS-2505) 33 6.
Gland Seal Exhaust a.
Noble Gas Activity Monitor (SRA-2805)
- b. Flow Rate Monitor (SFR-201)
(2-MR-054 and/or SRA 2810)
D.
C.
COOK - UNIT 2 (1)
(1)
(1) 3/4 3-59 28 27 27 Amendment No.
49 N >>4
TABLE 3. 3-13 (Cont. )
At all times
~*
During waste gas holdup system operation (treatment for primary system gases)
- Duringreleases via this patnway.
1For purge purposes
- only, see Technical Specifications 3.3.3.10, Table 3.3-13 and Table. 4.3-9 (Items 3.a, S.a in both tables) for non-purging requirements associated with this instrument.
2For gas decay tank releases
- only, see Item 3 (Unit Vent, Auxiliary Building Ventilation System) for additional requirements.
3The waste gas holdup system explosive gas monitoring system may be inoperable for up to 160 days on a one-time basis for the purpose of replacing one hydrogen and one oxygen monitor.
During this time grab samples for both hydrogen and oxygen are to be taken and analyzed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.
COOK NUCLEAR PLANT - UNIT 2 3/4 3-60 AMENDMENT NO. Nl, 114
TABLE 4.3-9 d o ctive Gaseous Efflue t o
tor n Inst Surveillance Re ui ements Inst ument nst ent =i CHANNEL CHANNEL SOURCE CHANNEL FUNCTIONAL
- 1. Paste Gas Holdup System Explosive Gas Monitoring System
- a. Hydrogen****
Monitor (QC-31)
- b. Oxygen****
Monitor (QC-31) c.
Oxygen Monitor (Alt., QC-370)
NA NA Q(3)
Q(4)
Q(4) 2.
Condenser Evacuation Systera a.
Noble Gas Activity Monitor (SRA-2905) b.
System Effluent Flow Rate (SFR-401, 2-MR-054, SRA-2910)
NA R(2)
Q(l)
- 3. Auxiliary Building Ventilation System a.
Noble Gas Activity Monitor (VRS-2505)
- b. Iodine Sampler (For VRS-2503)
- c. Particulate Sampler (For VRS-2501) d.
System Effluent Flow Rate'Measurement Device (VFR-315, 2-MR-054, VRS e.
Sampler Flow Rate Measurement Device (VFS-2521)
D*
-2510)
D*
NA NA NA R(2)
NA R
Q(1)
NA
- 4. Containment Purge System a.
Aux. Building Vent.
System Noble Gas Activity Monitor (VRS-2505)
- b. Aux. Building Vent.
System Particulate Sampler (For VRS-2501)
NA R(2)
NA Q(1)
NA
- 5. Paste Gas Holdup System a.
Noble Gas Activity Monitor Providing Alarm & Termination of Gas Decay Tank Releases (VRS-2505)
R(2)
Q(5)
D.
C.
COOK - UNIT 2 3/4 3-62 Amendment No. W>> 114
TABLE 4.3-9 (Cont)
Instrument Instrument
=i CEQQEL H.<iNEL SOURCE CHA~iEL FUNCTIONAL
.NECK CHECK CALIBRATION
~TES
- 6. Gland Seal Exhaust a.
Noble Gas Activi='SRA-2805) b.
System Effluent Flow Rate (SFR-201, 2-MR-054.
SRA-2810) vA R(2)
Q(1)
At all times
~*
During release via this pathway
- During waste gas holdup system operation (treatment for primary system offgases)
~***These surveillances are not required during the 160-day period in which this monitor is being replaced.
D.
C.
COOK - UNIT 2 3/4 3-63