ERRATA**

ATTACHMENT TO LICENSE AMENDMENT NO.

127 TO FACILITY OPERATING LICENSE NO.

DPR-58 DOCKET NO, 50-315 Revise Appendix A Technical Specifications-by removing the pages identified below and inserting the attached pages.

The revised pages are identified by amendment number and contain marginal lines indicating the area of change.

RENDVE 3/4 3-43 3/4 3-44 3/4 3-45 3/4 3-46 B 3/4 '3-2 5-9 UNIT 1 INSERT 3/4 3-4W 3/4 3-44**

3/4 3-45 3/4 3-46+

B 3/4 3-2 5-9

" Overleaf page provided to maintain document completeness.'o change contained on this page.

8908270006 890803 PDR ADOCN, 050003%5 P

PNU

TABLE 3.3-8 METEOROLOGICAL MONITORING INSTRUMENTATION INSTRUMENT 1.

WIND SPEED LOCATION INSTRUMENT MINIMUM MINIMUM ACCURACY OPERABLE Any 1/3 channels

a. Primary or Backup Meteorological Tower, Nominal Elev.

10 m

(1),(2)

b. Primary Meteorological Tower, Nominal Elev.

60 m

(1) (2) 2.

WIND DIRECTION

a. Primary or Backup Meteorological Tower, Nominal Elev.

10 m

+ 5 Any'1/3 channels

b. Primary Meteorological Tower, Nominal Elev.

60 m

+ 5 3.

AIR TEMPERATURE (for 60 m to 10 m delta T)

a. Primary Meteorological Tower, Nominal Elev.

10 m

I

b. Primary Meteorological Tower, Nominal Elev.

60 m

+ 0.15 C

+ 0.15 C

NA (1) Starting speed of anemometer shall be ( 1 mph.

(2) +

1% or 0.5 mph, whichever is greater.

(3) With delta T information unavailable, sigma theta (standard deviation of the horizontal wind direction as determined from emergency procedures) is to be used for the determination of stability class.

D.

C.

COOK - UNIT 1 3/4 3-44 Amendment No.

127

7 I

~

( ~'RRATA*

ATTACHMENT TO LICENSE AMENDMENT NO. 113 TO FACILITY OPERATING LICENSE NO.

DPR"74 DOCKET NO. 50-316 Revise Appendix A Technical Specifications by removing the pages identified below and inserting the attached pages.

The revised pages are identified by amendment number and contain marginal lines indicating the area of change.

REMOVE UNIT 2 INSERT 3/4 3"40 3/4 3-41 B 3/4 3-2 5-9 3/4 3-40*

3/4 3"41 B 3/4 3-2 B -3/4 3-2a 5-9

TABLE 3.3-8 METEOROLOGICAL MONITORING INSTRUMENTATION INSTRUMENT 1.

WIND SPEED LOCATION INSTRUMENT MINIMUM MINIMUM ACCURACY OPERABLE Any 1/3 channels

a. Primary or Backup Meteorological Tower, Nominal Elev.

10 m (1),(2)

b. Primary Meteorological Tower, Nominal Elev.

60 m

(1) (2) 2.

WIND DIRECTION Any 1/3 channels 0

a. Primary or Backup Meteorological Tower, Nominal Elev.

10 m

+ 5

b. Primary Meteorological Tower, Nominal Elev.

60 m

+5'.

AIR TEMPERATURE (for 60 m to 10 m delta T)

a. Primary Meteorological Tower, Nominal Elev.

10 m

b. Primary Meteorological Tower, Nominal Elev.

60 m

+ 0.15 C

+ 0.15 C

NA (1) Starting speed of anemometer shall be < 1 mph.

(2) +

1% or 0.5 mph, whichever is greater.

(3) With delta T information unavailable, sigma theta (standard deviation of the horizontal wind direction as determined from emergency procedures) is to be used for the determination of stability class.

D.

C.

COOK - UNIT 2 3/4 3%0;:.

Amendment Ho. Q,113

~

~