f
'ACCELERATED DISI'RIBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
ACCESSION NBR:8806220079 DOC.DATE: 88/04/30 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.
Cook Nuclear Power Plant, Unit 1, Indiana 05000315 AUTH.NAME AUTHOR AFFILIATION MICHAELSON Indiana Michigan Power Co.
(formerly Indiana 6 Michigan Ele i
RECXP.NAME RECXPXENT AFFILIATION
SUBJECT:
Monthly operating rept for Apr 1988 for DC Cook Unit l.
DISTRIBUTXON CODE:
IE24D COPIES RECEIVED:LTR ENCL SIZE-TITLE: Monthly Operating Report (per Tech Specs)
NOTES:
RECIPIENT
-XD rCODE/NAME
~ 'PD3-1 LA STANGiJ INTERNAL: AEOD/DOA ARM TECH ADV NRR/DOEA/EAB 11 NUDOCS-ABSTRACT RGN3 EXTERNAL: EGGG WILLIAMS,S NRC PDR COPIES
~ LTTR, ENCL
'0 0
AEOD/DSP/TPAB NRR/DLPQ/PEB 11 DREP/RPB 10 G FX 01 11, 1
1 LPDR NSIC RECIPIENT COPIES
~ID,CODE/PAMEi>>,, LTTR) ENCL,
~
PD3-1 PD i
I.
'" 5'"'")
j A
0 TOTAL NUMBER OF COPIES REQUIRED:
LTTR ~ ENCL 19
4 4
I
~
~
s/QV N.R.C.
OPERATING DATA REPORT DOCKET NO.
50 315 DATE 2 MAY 88 COMPLETED BY Michaelson TELEPHONE 616-465-5901 OPERATING STATUS
- 1. Unit Name D.
C.
Cook Unit 1
- 2. Reporting Period APR 88,'notes
- 3. Licensed Thermal Power (MWt) 3250 I
4.
Name Plate Rating (Gross MWe) 1152
- 5. Design Electrical Rating (Net MWe) 1030 I
6 ~
Maximum Dependable Capacity (GROSS MWe) 1056 7.
Maximum Dependable Capacity (Net MWe) 1020
- 8. If Changes Occur in Capacity Ratings (Items no.
3 through 7) Since Last Report Give Reasons 9.
Power Level To Which Restricted. If Any (Net MWe) 10 'easons For Restrictions. If Any-ni 11.
Hours in Reporting Period 12.
No. of Hrs. Reactor Was Critical
- 13. Reactor Reserve Shutdown Hours
- 14. Hours Generator on Line
- 15. Unit Reserve Shutdown Hours 16.
Gross Therm.
Energy Gen.
(MWH) 17.
Gross Elect.
Energy Gen.
(MWH)
- 18. Net Elect. Energy Gen.
(MWH)
- 19. Unit Service Factor
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (MDC Net)
- 22. Unit Capacity Factor (DER Net)
- 23. Unit Forced Outage Rate 24.
Shutdowns Scheduled over Next Six No This Mo.
Yr.
719.0 719.0 0.0 719. 0 0.0 2089788 681160 655125 00.0 to Date 2903.0 2850.3 0.0 2838.0 0.0 8171534 2663920 2560859 97.8 100.0 97.8 89.3 86.5 88.5 85.6 0
~ 0 0.9 Months (Type, Date,and Cumm.
116855.0 84688
~ 2 463.0 83075.5 321 '
241170532 78808590 75791857
- 72. 3 72
~ 3.
64
~ 7
'2
~ 6 8.1 Duration)-
- 25. If Shut Down At End of Report Period, Estimated Date of Startup-
- 26. Units in Test Status (Prior to Commercial Operation)-
Forcast INITIALCRITICALITY INITIALELECTRICITY COMMERCIAL OPERATION Achieved 8806220079 880430 PDR ADOCK 05000315 R
DCD o
4
UNITSIIUTI)01VNS ANI)POlVER kEl)ll('llONS REPOR'I'!PN fllMPRIL I)OCKETNO 50-315 l)ATE 5-6-88
(:(SIPIETEI)I<Y A.S.
Pu lis N<<.
I4<c j
Idee <<sec I!vent Rcp<<<l 4 8
gu
( ause h (<<<<ective hell<<<< t<<
Ptcvcnt Recu<tcnce 269 880430 S
00 OC-Hp HTEXCH Unit power was reduced to 58% to clean the main feed pump turbine condenser waterboxes.
Power was restored to 90%'administrative limit) on 5-1-88.
I I': I'l<<cell S: Sch<ululc<l I'>lIII Re<<sun:
A.I."<pdpu<cnt I <<ilute (Explatni I) AI<<bitenanc<<<<i Tesl
('efuelb<il I) Rcydat<<<y Rests}ctbu<
I'.@pc<<<t<<< I'tah<b<g 4 Ijccnsc Iixa<nlnatb<u I'.Ad<ninlsl<allve (I OJ<c<atl<<<< ll I:It<<< II:xpl<nul II(llhct II!xpl<<b<l 3
i<lethal:
i%I<<nuai 2 Manual Seta<<<.
3.A<<t<<n<atlc Sct<<<n.
44)<i<et ILxpl<<in) fxhibll Ci - lnsl<ucliu<<s f<u ptq<<<<ati<u< <<f I)>>t>>
I:nl<y M<ccts l<u Ilccnscc Event kcp<<<t II.I'.RlI'ilcINltkl(<.
OI6II txinbit I S<<n<c S<<u<L<.
V
~
~ ~
~
e AVERAGE DAILY POWER LEVEL (MWe-Net)
MONTH DOCKET NO.
50-315 UNIT ONE DATE 2 MAY 88 COMPLETED BY Michaelson TELEPHONE 616-465-5901 APR 88 DAY 1
2 3
4 5
6 78" 9
10 11 12 13 14 15 16 AVERAGE DAILY POWER LEVEL 920 925 925 924 925 924 923 923 923 922 922 919 922 921 920 918 DAY 17 18 19 20 21 22 23 24 25 26 27 28 29 30 AVERAGE DAILY POWER LEVEL 922 916 921 920 922 921 919 918 917 913 912 914 916 609 j
r
0