ML17325A461

From kanterella
Jump to navigation Jump to search
Forwards Five Oversize Drawings,In Response to NRC 871106 Request,Showing Layout of Spent Fuel Pool Ventilation Sys Equipment in Support of Review of Util 870528 Tech Spec Change Request
ML17325A461
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 11/23/1987
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Murley T
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
Shared Package
ML17325A462 List:
References
AEP:NRC:0959A, AEP:NRC:959A, NUDOCS 8711300124
Download: ML17325A461 (6)


Text

REGULATO NFORNATION DISTRIBUTION TEM (RIDS)

ACCESSION NBR: 8711300124 DOC. DATE: 87/11/23 NOTARIZED:

NO DOCKET 0 FACIL: 50-315 Donald C.

Cook Nuclear Power Planti Unit ii Indiana 5

05000315 50-316 Donald C.

Cook Nuclear Power Planti Unit 2i Indiana 8c 05000316 "AUTH. NANE AUTHOR AFFILIATION ALEX ICHOR M. P.

Indiana Michigan Poeer Co.

(formerly Indiana Zc Nichigan Ele RECIP. MANE RECIPIENT AFFILIATION MURLEYa T. E.

Document Control Branch (Document Control Desk)

SUBJECT:

Forwards five oversize drawingsi in response to NRC 871106 requests shoeing

)about of spent fuel pool ventilation sos equipment in support of. review of-util 870528 Tech Spec change request.

~Awi4G5 DISTRIBUTION CODE:

A001D COPIES RECEIVED: LTR ENCL SIZE TITLE:

OR Submittal:

General Distribution NOTES:

REC IP IENT ID CODE/NANE PD3-3 LA WIQGINQTONi D COPIES LTTR ENCL 0

1 1

REC IP IENT ID CODE/NANE PD3-3 PD COPIES LTTR ENCL 5

5 INTERNAL: ARN/DAF/LFNB NRR/DEBT/CEB NRR/DEBT/RSB N

-- AS/ILRB G FILE 01 EXTERNAL:

EQ8cQ BRUSKEi S NRC PDR 1

0 1

1 1

1 1

1 1

1 1

1 1

1 NRR/DEST/ADS NRR/DEST/NTB NRR/DOEA/TSB OQC/HDS1 RES/DE/EIB LPDR NSIC 1

1 1

1 1

1 1

0 1

1 1

1 1

/<use

+

Fi<c-TOTAL NUNBER OF COPIES REQUIRED:

LTTR 21 ENCL 18

Indiana Michigan Power Company One Summit Square P.O. Box 60 Fort Wayne, IN 46801 219 425 2111 AEP:NRC:0959A Donald C.

Cook Nuclear Plant Units 1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 REQUEST FOR ADDITIONAL INFORMATION ON SPENT FUEL POOL VENTILATION U.S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.C.

20555 Attn:

T.

E. Murley November 23, 1987

Dear Dr. Murley:

This letter responds to a request made by your stiff during a telephone conversation of November 6, 1987.

Specifically, we were requested to provide drawings of the layout of the spent fuel pool ventilation system equipment.

The drawings were requested to support the review of our letter AEP:NRC:0959, dated May 28,

1987, which proposed changes to the technical specifications for the spent fuel pool ventilation system.

In response to this request, we have included the following drawings as an attachment to this letter.

Drawin No.

Title 1.

12-5148A-15 Flow Diagram: Auxiliary Building Ventilation 2.

12-5163-5 Plant Arrangement:

Sections "G-G,",

"H-H " "J-Ji" and "K-K" 3.

12-5168-8 Plant Arrangement:

Mezzanine Floor El. 609'-0" 4.

1-5731-11 Heating and Ventilating: Auxiliary Building Floor East 633'-0" and 650'-0" 5.

12-5735-8 Heating and Ventilating: Auxiliary Building Sections and Details STllaoosae S7l<>>~>'DR ADOCK 05000~>5, p

PDR g

%5 OO

)1

O.

1

~j V'

Dr. T.

E. Murley AEP:NRC:0959A Drawin No Title 6.

Unnumbered Simplified Flow Diagram Indicating Location of Sample Ports In accordance with the restrictions as to use set forth on the drawings provided in Attachment 1, AEPSC hereby releases these documents to the NRC for its information and use in connection with the review of our submittal No. AEP:NRC:0959.

AEPSC also permits the NRC to reproduce the drawings as necessary to facilitate review and distribution of the drawings to meet NRC requirements.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to ensure its accuracy and completeness prior to signature by the undersigned.

Sincerely, M.

. Al xich Vice President cm Attachment cc:

John E. Dolan W.

G. Smith, Jr.

- Bridgman R.

C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector

- Bridgman A. B. Davis

- Region III

Attachment to AEP:NRC:0959A Drawings Related to Spent Fuel Pool Ventilation

IOu~Ir No

> Va;~i SIMPLIFIED -"'LO~I DIAGRMI I

~4

&PEAT FUEL POOL EL. CoGO'-0' J

l l,)ll) l J

7kL, c 5o'-o'-

l2 VPX'nlFUrl*VI~

330 SIGMA,LSq I2-vPx I

333 r

I I

I=C e

4C.

I I=.C ~

I OUTLH PLENUM I

I I ~DDWkSrRCn~

I

$8OI Pc C PO lh'Ts II YFA 3$$$

IP.VF>

3338 Qo P f',EFRICERRn'f I/YJ ECTION POINTS I2 vPx

'32 D '

~0DO----

DD OPS TREn~

SRNI PCE PO in'T Ell 3S'O'onald C. Cook Nuclear Plant November 23, 1987