ML17325A053

From kanterella
Jump to navigation Jump to search
Responds to NRC Re Violations Noted in Insp Repts 50-315/87-06 & 50-316/87-06.Corrective Actions:Protective Action Recommendation Calculation Will Be Computerized by Modifying Dose Assessment Program
ML17325A053
Person / Time
Site: Cook  
Issue date: 04/13/1987
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Davis A
NRC
References
AEP:NRC:0965J, AEP:NRC:965J, NUDOCS 8704200417
Download: ML17325A053 (4)


Text

(

M REGULATORY INFORl"lATION DISTRIBUTION SYSTEM (R IDS)

ACCESSION NBR: 8704200417 DOC. DATE: 87/Oi/13 NOTARIZED: "NQ DOCKET ¹ FAG IL:50-315 Donald'.

Cook Nuclear Pouer PlantUnit ii Ind iana 0

05000315 50-316 Donald C.

Cook iluclear PoiJer Plant>

Unit 2i Indiana 5

05000316

'TH. MANE, AUTHOR AFFILIATION XICH> N. P.

Indiana 5 Nichigan Electric Co.

CIP. NAi'1E RECIPIENT AFFILIATIQ4 DAVIS~ A. B.

NRC No Detailed AFFiliation Given SUB JECT:

Responds to NRC 870227 1 tr re violations noted in Insp Repts 50-31 5/87-06 8c 50-316/87-06.

Corr e ctive a c tion s: pr ot e ctive action recomm'endation calcula+ion vill be computeri zed bg bg modi Fling dose assessmen+

program.

DISTRIBUTION CODE:

IE01D COPIES RECEIVED: LTR ENCl SIZE:

TITLE: General (50 Dkt)-Insp Rept/No+ice oF Violation Response NOTES:

RECIPIENT ID CODE/Nhl'1E PD3-3 LA WIQQINGTONp D INTERNAL: AEQD ENF LIEBERNAN NRR/ADT

.NRR/DREP/EPB NRR/DRIS DIR QGC/HDS1 RES SPEIS, T EX NAL:

LPDR NSIC COPIES LTTR ENCL 1

'0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

RECIPIENT ID CODE/N*l'1E PD3-3 PD DEDRO NRR RQE> H. L I':RR/DOEA DIR NRR/DREP/RPB NRR AS/ ILRB EG FIL RQN3 FILE 01 NRC PDR COPIES I TTR ENCL 1

1 1

1 1

1 1

2 2

1 1

1 1

1 1

1 TOTAL NUNBER QF COPIES REQUIRED:

LTTR 21 ENCL 20

0

INDIANA8 MICHIGAN ELECTRIC COMPANY P,O. BOX 16631 COI.UMBUS, OHIO 43216 April 13, 1987 AEP:NRC;0965J Donald C.

Cook Nuclear Plant Unit Nos.

1 and 2

Docket Nos.

50-315 and 50-316 License Nos.

DPR-58 and DPR-74 NRC ICE.

INSPECTION REPORTS NO. 50-315/87006 (DRSS);

AND NO. 50-316/87006 (DRSS)

U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D.

C.

20555 Attention:

A. B. Davis

Dear Mr. Davis:

This letter responds to your letter dated February 27,

1987, which forwarded the subject Inspection Reports of the routine safety inspection conducted by your staff at the Donald C.

Cook Nuclear Plant on February 9-11, 1987.

The appendix of your letter identified one exercise weakness.

As requested by your letter, attached is the response to the exercise weakness.

This letter has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Very truly yours, M.

. Alexich Vice President edg Attachment cc:

John E. Dolan W.

G. Smith, Jr.

- Bridgman R.

C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector

- Bridgman H. R. Denton 87O42 DOCH, 05OOOS15 00417 870413 PDR AD PDR 8

ATTACHMENT TO AEP:NRC:0965J denti ed Wea ess "Due to the short time interval between notifications to the State, PMP 2081 EPP.305,, "Prote'ctive Action Recommendation Worksheet" could not be completed with the attention it deserved nor is there time for recalculation to verify the accuracy of the initial calculations.

During the exercise, incorrect calculations were made on the form completed at 2045 hours0.0237 days <br />0.568 hours <br />0.00338 weeks <br />7.781225e-4 months <br />, resulting in a ten Rem error for the two mile thyroid dose estimate In addition, this form was virtually unreadable.

The delay in completing calculations using this form left little or no time for discussion of the PARs.

Rather, the results were given to the EOF/Recovery Manager and were then transmitted to the State, without adequate discussion of PARs with respect to plant conditions, forecast meteorology, etc.

(Open Item 315/87006-01; 316/87006-01)

(Section 5.e)."

Cor ect ve Act ons The Protective Action Recommendation (PAR) calculation will be comput'erized.

This will be accomplished by modifying the current Dose Assessment Program (DAP) to include the PAR worksheet.

The PAR worksheet is currently Attachment 2 to PMP 2081 EPP.305.

Computerizing the worksheet will make calculating the PAR both quicker and more accurate.

This action should in turn allow time fo>>

discussion of the PAR with respect to plant conditions, forecast meteorology, etc.

ate When Co rect ve Actions Wi Be Com eted The modification of the Dose Assessment Program to include the PAR calculation will be completed by November 30, 1987.

Procedure revision and training to incorporate this change to the Dose Assessment Program into the Donald C.

Cook Emergency Response will be completed by February 28, 1988.