ML17321A983

From kanterella
Jump to navigation Jump to search
Summary of 851114 & 15 Meetings W/Util Re Wrong Train/Wrong Unit Events,For Use in Developing Guidance for Industry to Prevent Events at Other Plants
ML17321A983
Person / Time
Site: Cook  
Issue date: 11/27/1985
From: Wigginton D
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8512090370
Download: ML17321A983 (5)


Text

Docket Nos.

50-315 and 50-316 November 27, 1985 LICENSEE: Indiana and Michigan Electric Company (IMEC)

FACILITY: Donald C.

Cook Nuclear Plant, Unit Nos.

1 and 2

SUMMARY

MEETING HELD ON NOVEMBER 14 AND NOVEMBER 15, 1985 WITH IMEC TO DISCUSS WRONG UNIT/WRONG TRAIN EVENTS A meeting was held at the Donald C.

Cook Nuclear Plant between members of the NRC and staff from the plant and corporate offices to discuss wrong train/wrong unit events.

These are events when an operator performed some activity incorrectly by taking the action on the wrong train of a system or on the wrong unit.

The meeting was requested by the NRC to obtain information for use in developing guidance for the industry in preventing such events.

The meeting was attended by D. Wigginton, D. Persinko, Ann Ramey-Smith, and Jim Heller.

The licensee was prepared with a detailed presentation including samples from the tagging and labeling program underway and photographs of the areas involved in the wrong train/wrong unit events.

In addition to the labeling problems as a source of incorrect action, the licensee has also undertaken efforts to correct,

separate, and update procedures to prevent reoccurrence of the events.

Discussions were also held with the auxiliary operators and technicians that performed the events in order to determine the root cause of the errors.

The staff was very satisfied by the information presented and the individual discussions with the operators.

/s/DWigginton cc:

See next page David L. Wigginton, Senior Project Manager PWR Project Directorate P5 Division of PWR Licensing-A PWR/5-A DWigginton;ps 11/7,7/85

( 9512090370 851%27 PDR ADOCK 05000~> >

g PDR

r ll f

Mr. John Dolan Indiana and Michigan Electric Company Donald C.

Cook Nuclear Plant CC:

Mr. M. P. Alexich Vice President Nuclear Operations American Electric Power Service Corporation 1 Riverside Plaza

Columbus, Ohio 43215 Attorney General Department of Attorney General 525 West Ottawa Street Lansing, Michigan 48913 Township Supervisor Lake Township Hall Post Office Box 818 Bridgman, Michigan 49106 W. G. Smith, Jr., Plant Manager Donald C.

Cook Nuclear Plant Post Office Box 458 Bridgman, Michigan 49106 U.S. Nuclear Regulatory Commission Resident Inspectors Office 7700 Red Arrow Highway Stevensville, Michigan 49127 Gerald Charnoff, Esquire Shaw, Pittman, Potts and Trowbridge 1800 M Street, N.W.

Washington, DC 20036 Mayor, City of Bridgeman Post Office Box 366 Bridgman, Michigan 49106 Special Assistant to the Governor Room 1 - State Capitol Lansing, Michigan 48909 Nuclear Facilities and Environmental Monitoring Section Office Division of Radiological Health Department of Public Health 3500 N. Logan Street Post Office Box 30035 Lansing, Michigan 48909 The Honorable John E. Grotberg United States House of Representatives Washington, DC 20515 Regional Administrator, Region III U.S. Nuclear Regulatory Cortmission 799 Roosevelt Road Glen El lyn, Illinois 60137 J. Feinstein American Electric Power Service Corporation 1 Riverside Plaza

Columbus, Ohio 43216

MEETING

SUMMARY

DISTRIBUTION Docket or Central fil,~

NRC PDR Local PDR ORB¹1 RDG Steve Varga D. Wigginton OELD E. Jordan P.

McKee ACRS (10)

NSIC Gray file Plant Service List C. Parrish J. Partlow

\\l i>

~v'