Text
REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS).
ACCESSI'ON NBR: 8508150237 DOC ~ DATE: 85/08/13 NOTARIZED:
NO DOCKET FACIL:50-315 Donald C,
Cook Nuclear Power Plant~
Unit ii Indiana 8
05000315 AUTH,NAME, AUTHOR AFFILIATION ALEXICHi M, P, Indi ana
- 8. Mi c hi gan E l ec t r i c Co.
RECIP ~ NAME RECIPIENT AFFILIATION DENTONiH ~ RE Office of Nuclear Reactor Regulationi Director
SUBJECT:
Forwards nonproprietary safety evaluations in response to request for addi info re RdF resistance temp detectors, Install'ation sill not impact assumed safety analysis limits.
DISTRIBUTION CODE:
A0010 COPIES RECEIUED:LTR i'NCL Q SIZE':
TITLE:
OR Submittal:
General Distribution NOTES:
OL; 10/25/7Q 05000315 RECIPIENT ID CODE/NAME NRR ORB1 BC 01 INTERNAL: ACRS 09 ELD/HDS3 NRR/DL DIR NRR/DL/TSRG NRR/DSI/RAB RGN3 COPIES LTTR ENCL 7
7 6
6 1
0 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME ADM/LFMB NRR/DE/MTEB NRR/DL/ORAB N
METB FILE 04 COPIES
'LTTR ENCL 1
0 1
1=
1 0
1 1
1 1
EXTERNAL: 24X LPDR NSIC 03 05.
1 1
1 1
1 EGlllG BRUSKEES NRC PDR 02 1
1 1
1 TOTAL NUMBER OF COPIES REQUIRED:
LTTR 28 ENCL 25
I F,
~
~
A 1
II g
Ir 1
4 I
tl 1
A II
INDIANA 8 MICHIG AN ELEC TR IC CON PA NY P.O. BOX 16631 COLUMBUS, OHIO 43216 August 13, 3.985 AEP:NRC:0942E Donald C.
Cook Nuclear Plant Unit, No.
1 Docket No. 50-315 License No. DPR-58 ADDITIONAL INFORMATION FOR RdF RTD TECHNICAL SPECIFICATIONS Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Dear Mr. Denton:
In our letter AEP:NRC:0942D dated August 13, 1985 we indicated that the non-proprietary versions of the two safety evaluations, identified as Attachments 1 and 4 in that letter, would be sent to the U.S. Nuclear Regulatory Commission under a separate letter.
Attached, please find these two safety evaluations.
This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.
Very truly yours, I
/
M P. Ale ich Vice Pre ident cm Attachment cc:
John E. Dolan W. G. Smith, Jr.
Bridgman R. C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector Bridgman 85p8igP237'ppp~15 85p8iS-
,PDR
-ADQCH pgR0
ll M
A J