Informs That Exxon Nuclear Co Transmitted Two Repts on 850403 & 04.Administrative Control Will Be Modified to Allow Use of K(Z) Curve from Exxon Rept & in Tech Specs.Loca/Eccs Analyses Will Be Submitted by 850426
ML17321A531
Person / Time
Site: Cook 
Issue date: 04/04/1985
From: Alexich M
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: Harold Denton
Office of Nuclear Reactor Regulation
References
AEP:NRC:08604, AEP:NRC:8604, NUDOCS 8504110225
Download: ML17321A531 (6)


Text

REGULATORY %FORMATION DISTRIBUTION SY M (RIDS)

ACCESSION,NBR ~ 8504110225 DOC ~ DATE ~ 85/04/04 NOTARIZED s NO FACIL:50<<316 Donald C,

Cook Nuclear Power Planti Unit 2i Indiana AUTH BYNAME AUTHOR AFFILIATION ALEXICHiM,PE Indiana 8 Michigan Electric Co.

RECIP ~ NAME RECIPIENT AFFIL'IATION DENTONgH ~ RE Office. of Nuclear Reactor Regulationi Directar DOCKET 05000316

SUBJECT:

Informs that Exxon Nuclear Co transmitted two repts on 850403 L 04,Administrative control will be modified to allow use of K(Z) curve from Exxon rept 8 in Tech Specs, LOCA/ECCS analyses will be submitted by 850426, DISTRIBUTION CODE ~

A001D COPIES RECEIVED:LTR, ENCL SIZE; TITLE:

OR Submittal:.General Distribution NOTES:

OL e 12/23/72 05000316 RECIPIENT ID CODE/NAME NRA ORB1 BC 01 INTERNAL; ACRS 09 ELD/HDS3 NRR/DL DIR NRR/DL/TSRG NRR/DSI/RAB RGN3 COPIES LTTR EN L

7 RECIPIENT COPIES ID CODE/NAME LTTR ENCL-ADM/LFMB NRR/DE/MTEB NRR/DL/DRAB METB REG FIL 04 EXTERNAL; EGLG BRUSKEgS NRC PDR 02 LPDR NSIC 03 05 TOTAL NUMBER OF COPIES REQUIRED:

LTTR 27 ENCL

~J I

x 4

g II l

II i

~ fi.

n lh

~)g INDIANA8 MICHIGAN ELECTRIC COittIPANY P.O. BOX 16631 COLUMBUS, OHIO 43216 April 4, 1985 AEP:NRC:0860Y Donald C. Cook Nuclear Plant Unit No.

2 Docket No. 50-316 License No. DPR-74 Exxon EXEM/PWR LOCA Model - FLECHT Recorrelation Unit 2, Cycle 5 LOCA/ECCS Analysis Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Denton:

As discussed with your staff, this letter is to inform you that Mr. J.

C. Chandler of Exxon Nuclear Company (ENC) has transmitted the reports listed below.

This transmittal was by ENC letters JCC:064:85 dated April 3, 1985 and JCC:068:85 dated April 4, 1985.

')

Report 1:

"Modification of the FLECHT Based Reflood Quench and Heat Transfer correlations for D., C. Cook Unit 2,"

XN-NF-85-20(P).

2)

Report 2:

"Donald C. Cook Unit 2, Cycle 5, 5% Steam Generator Tube Plugging Limiting Break LOCA-ECCS Analysis":

K(Z) curve.

Report 1 provides the revised 17X17 FLECHT correlations for use in the D. C. Cook Unit 2 LOCA/ECCS Analysis.

Report 2 details the results of the LOCA/ECCS analysis performed for D. C. Cook Unit 2, Cycle 5.

The analysis, using the correlation in Report 1 indicate significant improvements in the Fq limits at the upper core elevations due to the use of the more accurate reflood heat transfer coefficients at the top portion of the reactor.

This is reflected in the K(Z) curve shown in Figure 2.1 of Report 2.

Based on discussions with your staff we will modify the administrative control discussed in our letter AEP:NRC:0860X dated February 1, 1985.

This modification will allow use of the K(Z) curve in Report 2 along with the K(Z) curve in our Unit 2 technical specifications, whichever is the most limiting at any axial location.

Based on discussions with Exxon Nuclear Co.,

we believe operation in the above manner will assure compliance with 10 CFR 50.46 and Appendix K to 10 CFR Part 50.

As can be seen in Report 2, there is considerable margin in peak clad temperature for analyses with skewed power distributions.

In order to utilize this PCT margin, ENC is currently performing LOCA/ECCS analyses with a less restrictive K(Z) for Unit 2, Cycle 5.

We plan to transmit these analyses to you on or before April 26, 1985.

We expect the K(Z) curve to be less restrictive than that shown in Figure 2.1 of Report 2.

F 8504110225 850404 PDR ADOCK 0500031 h I

~~

~ <<

P ~

IP p ~,

p r

~

I IP 1

F lhf h

g

>>P

'I

.l;0 'h

~

~

if F I

I, S

~

h

~

I I ~

)

lh

~

r

~

<<PP h>>".

~

5

$I'<<'

F f a" ~ f

~ f IP

)

<<h F

h Stf F)

)

~

"h

~

hj

~

~ y>>

'I h

)

F C IF

Mr. Harold R. Dent g

n AEP:NRC:0860Y Operation under the new administrative limit will be reviewed by our Corporate and Plant Safety committees prior to implementation.

This document has been prepared following Corporate procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.

Very truly yours, M

. Alex'ch Vice President 4<<

Attachments cc:

John E. Dolan W. G. Smith, Jr. Bridgman R. C. Callen G. Bruchmann G. Charnoff NRC Resident Inspector Bridgman

'J

~ 'I

'I 0