lg REGULA Y
INFORMA'TION DISTR I BUT IO YSTEM (R IDS)
AOCES SION NBR: 82102204l78 DOC ~ DATE! 82/10/15 NOTARIZED:
NO FACIL:50 315 Donald C+
Cook Nuclear Power Planti Unit ii Indiana 8
AUTH,NAME AUTHOR AFFILIATION HUNTERiR ~ Se Indiana 8 Michigan Electric Co,
'ROC IP, NAME RECIPIENT AFFILIATION DENTONsH ~ Re Office of Nuclear Reactor Regulationi Director DOCKET 0500031'5 NOTES:
SUBJECT:
'Submits followup ~to 820907'7 L ?0 ltvs re emergency relief requests from Tech Spec '3,5,2.Repairs of north safety inJection pump completed within alloted relief time granted by Amend 62,Amend fee encl.
DISTRIBUTION CODE:
A001S
~COP IES RECEI VED:LTR, ENCL SIZE:. ~
i TITLE:
OR Submittal'.
General Distribution
~/~
< t2uo.
RECIPIENT
'COPIES RECIPIENT
'COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL NRR ORB1 BC 01 7
7 INTERNAL: ELD/HDS3 NRR/DL DIR NRR/DS I/RAB RGN3 1
0 1
1 1
1 1
NRR/DHFS DEPY08 B
REG FILE 04 1
1 1
0 1
1 EXTERNAL: ACRS NRC PDR NTI'S 09 02 6
6 1
1 1
1 LPDR NSIC 03 05 1
1 1
<TOTAL NUMBER OF COPIES REQUIRED:
UTTR 20 ENCL 22
7 7
V)(l
'ult
,"II f tlat f 'rll ~ t ),'!
('
))I f>>f)f,f I rr)l, 0 )I, ttt r)
'j
')l) $ ')'~') If Il ql)') W 0 f It',
< '44,II) [ X'gtl
~o ] '<'I4 ~ ')gr l
.w )')~i)'~
"lr) ->0" l
') fy'I l > [Jlrt,t4r)s
)
~ l ') f 4t
. 6'4 l li'44 I i 0 g l 1 I4 '~
-)(44'l 1 lc~
'>f )P')r)f 3
f)'yI <I,'r)fi)gjfihl Iif l tl l 'II'I4",l It !
lit 3 I
r)I,Q [ QII 4
." f Pu 4)("
I.,P
~ ~
e I+ )a i lt N ll 0l j')
t*4
)h l
It
)
rf + 1'
~
I'I)I
'g~t,
,III f~~),~i r
)I f Ilti
~ f ) )ft u' '('(, I;4 5 )
lil ') t fiej 4 r)fi))
I~+
t ,
~ rt,af g*t
~ ) )I ) Q tr) $
I%<) r)
~~erea~ep W~~,~ +
tt) jf f 1
I) tI~
II jf tf 4ut t I )t t4
)
4 t
J l'4), 'l I'l II u
"'i I4$
ll
',4 gt)
~l
>>I $ l I't4ri
0 INDIANA F( MICHIGAN ELECTRIC COMPANY P. O.
BOX 18 BOWLING GR E EN STATION NEW YORK, N. Y. 10004 October 15, 1982 AEP:NRC:0739D Donald C. Cook Nuclear Plant Unit No.
1 Docket No. 50-315 License No. DPR-58 REQUEST FOR RELIEF FROM TECHNICAL SPECIFICATION 3.5.2 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C.
20555
References:
1)
Letter No. AEP:NRC:0739 dated September 7,
1982 2)
Letter.No.
AEP:NRC:0739B dated September 17, 1982 3)
Letter No.
AEP NRC:0739C dated September 24, 1982
Dear Mr. Denton:
This letter is a follow-up letter to the above referenced letters regarding emergency relief requests from Technical Specification No. 3.5.2 of Unit 1 of the Donald C. Cook Nuclear Plant.
Please be advised that the repairs of the Unit 1 North Safety Injection pump have been successfully completed.
The pump was declared operable on September 29, 1982, within the alloted relief time granted by Amendment No.
62 to the Operating License of Unit 1.
Since the pump has been restored to operable status, we are hereby formally withdrawing our letter No. AEP:NRC:0739C dated September 24, 1982 (Reference 3) which was telecopied to you on September 24, 1982.
The requests for relief from the technical specification contained in references (1) and (2) have been reviewed both by the Plant's PNSRC and AEPSC's NSDRC.
As required by 10 CFR 170.22, a check in the amount of
$9,200.00 is attached to this letter in payment of the NRC processing of the above referenced requests.
The fee was calculated as follows:
$4,000 for reference (1) as a Class III amendment,
$ 1,200 for reference (2) as a Class II Amendment, and
$4,000 for reference (3) as a Class III Amendment.
82i0220478 82iOi5 PDR ADOCK 05000315' PDR
ho~I
~(cAock//goo,oO
w it E
~
II b
)
.hh r)
)
>v},I I'}
1)}
I ha) f)
)
}
~ f t'
E h I
~
'I a
I
~
1
~
'I Il I.
. ~ ~
~'1 lt
)
Rr vt
).)" It t'Jl I'1
'I II II 1
~
r
)
}
I rt,'bt I'
l' a,
I',
ttI't V
')
I I
'r frW
- R, ~
f1*
1 r
I' I
W 7$
1}
I I
I R
))r.) '
)
~
1 If'"
}l r
r
~
r fb b
)
FI f f
<r
}
II F,
f b'
)
~
b
,h r
~ w r f
1
~
fA
~
S Mr. Harold R.
D on AEP.
C:0739D Copies of References (1) and (2) are attached for your information.
Our review of both those references has found that no modifications to them are necessary.
We thank you for your expeditious attention to our requests.
This document has been prepared following Corporate Procedures which incorporate a reasonable set of controls to insure its accuracy and completeness prior to signature by the undersigned.
Very truly yours, S. Hunter Vice President
/os cc:
John E. Dolan Columbus M. P. Alexich R.
W. Jurgensen W. G. Smith, Jr. - Bridgman R.
C. Callen G. Charnoff Joe Williams, Jr.
NRC Resident Inspector at Cook Plant Bridgman
0 il F
iv