A~nndix A NOTICE OF VIOIATION American Electric Power Service Corporation Indiana and Michigan Power Company Docket No. 50"315 As a result of the inspection conducted on July 16-18, and 20,

1981, and in accordance with the Interim Enforcement Policy, 45FR66754 (October 7, 1980), the following violation was identified:

10 CFR 50, Appendix J, Section III.A.lstates in part that "If during a

Type A test....potentially excessive leakage paths are identified which will interfere with satisfactory completion of the test...the Type A test shall be terminated and the leakage through such paths shall be measured using local leakage tes'ting methods."

l Contrary to the above, three potentially excessive leakage paths, one at a flange connection on valve ECR-33, one involving stem packing on valve GCR-314, and one in isolation check valve CA-181N, were identified and repaired without performing the required measurements.

This is a Severity Ievel V violation (Supplement I).

Pursuant to the prove.sxons of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each item of noncompliance:

,(1) cor-rective action taken and the results achieved; (2) corrective action to be taken to avoid further noncompliance; and (3) the date when full compliance will be achieved.

Under the authority of Section 182 of the Atomic Energy Act of 1954, as

amended, this response shall be submitted under oath or affirmation.

Consideration may be given to extending your response, time for good cause shown.