ML17318A755
| ML17318A755 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 05/12/1980 |
| From: | Dolan J INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG |
| To: | |
| Shared Package | |
| ML17318A756 | List: |
| References | |
| AEP:NRC:00363, AEP:NRC:363, NUDOCS 8005200523 | |
| Download: ML17318A755 (8) | |
Text
REGULATORY "Ii%IRMATION DISTRIBUTION SYSTEM,
~ (RIDS)
ACCESSION NBR!8005200523 DOC~DATE: 80/05/12 NOTARIZED:
NO DOCKET FACIL;50 315 Donald C ~
Cook Nuclear Power Planti Unit 1g Indiana 8
05000315 AUTH ~ NAME 'UTHOR AFFILIATION DOLANiJ ~ ED Indiana 8 Michigan Electric Co.
RECIP,NAME RECIPIENT AFFILIATION SUBJECTS Application to amend License DPR~58 to revise Tech Specs covering section 3/4,2 '
DISTRIBUTION CODE:
A001S COPIES RECEIVED:LTR i ENCL)'IZE:
'ITLE:
General Distribution for after Issuance of Operatini Lic
~ores: ~~X - > Q4 dc'g~
Wj<EM<C.=g~~~~~
RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL ACTION:
05 BC Og W l 7
7 INTERNAL 0
c 12 I 17 ENGR QR 19 PLANT SYS BR 21 EFLT TRT SYS OELD EXTERNAL: 03 LPDR 23 ACRS 1
2 2,
1 1
1 1
1 1
0 1
1 16 16 02 NRC PDR 15 CORE PERF BR 18 REAC SFTY BR 20 EEB EPB~DOR STS GROUP LEADR 04 NSIC 1
1 1
1 1
1 1
1 1
1 1
MAY p p. 1980 c/(
c(O TOTAL NUMBER OF COPIES REQUIRED:
LTTR M
ENCL
~
~
8005800 W~
INDIANA L MICHIGAN ELECTRIC COMPANY P. O.
BOX 18 BOWL.ING GREEN STATION NEW YORK, N. Y. 10004 May 12, 1980 AEP:NRC:00363 Donald C.
Cook Nuclear Plant Unit No.
1 Docket No. 50-315 License No.
DPR-58 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555
Dear Mr. Denton:
This letter and its attachments serve to request changes to the Donald C.
Cook Nuclear Plant Unit No.
1 Appendix 'A'echnical Specifications.
The proposed revisions will allow operation of Unit No.
1 with Exxon Nuclear Company (ENC) power distribution control procedures.
These changes are based on ENC Topical Reports XN-NF 57 and XN-NF-77-57 Supplement 1, previously submitted by ENC to the NRC, which described the ENC recommended generic procedure for controlling axial power distribution.
All of the proposed changes contained herein have been reviewed and approved by the Plant Nuclear Safety Review Committee and the AEPSC Nuclear Safety and Design Review Committee.
These reviews indicate that in no instance will the proposed changes adversely affect the health and safety of the public.
This application for Technical Specification revision is considered to be a Class III License Amendment as per the provisions of 10 CFR 170.22.
As required by Part 170, Subsection 22, a check in the amount of $4,000.00 accompanies this submittal.
Attachment cc:
R.
C. Callen G. Charnoff D. V. Shaller - Bridgman R.
S. Hunter R.
W. Jurgensen Very truly yours, hn E. Dolan ce President goo/
sf/
W/ckbc/l.
lI Yoog.yg
I
~~
II
'1 I
J
,~, l4 I
The proposed Technical Specifications contained in Attachment
'B'o this submittal will allow operation of D. C.
Cook Unit No.
1 with Exxon Nuclear Company (ENC) power distribution control procedures.
Technical Specification pages 3/4 2-1 through 3/4 2-7, 3/4 2-8(a),
3/4 2-15 through 3/4 2-18, B3/4 2-2, and B3/4 2-6, have been revised to reflect the ENC procedures.
A copy of the entire Technical Specification Section 3/4,2 has been included in Attachment 'B'or completeness.
The requested revisions are marked with a vertical line in the right hand margin.
'he proposed revisions continue to reflect exposure dependent Fq limits.
Included in the proposed revisions are:(1) determination of
'xial flux difference every 31 effective full power days in conjunction with the measurement of Fq, (2) limiting condition for and application of the variation function V(Z), and (3) a curve of V.(Z) as a function of core height.
Upon approval of this, request, page 3/4 2-21 (Figure 3.2-.4) would be deleted from the Technical Specifications.
E
. ~
1
ATTACHMENT 'A'O AEP:NRC:00363
ATTACHMENT 'B'O AEP:NRC:00363