~y,R Afoot Wp
+
0
~p%
UNITED STATES NUCLEAR REGULATORY COMMISSION REGION III 799 ROOSEVELT ROAD GLENELLYN,ILLINOIS60137 Special Report:
WASTE PACKAGING INSPECTIONS OF LICENSEE-SHIPPERS REPORT NO ~ 79-06A Shipping No:
017689; 017725 Licensee-Shipper:
American Electric Power Service Corporation D.
C.
Cook 1 8 2 Disposal Site:
Chem-Nuclear
- Systems, Inc.
P.OS Box 726 Barnwell, South Carolina 29812 Docket No ~
15000039 Inspector:
RE AD Brown, Radiation Specialist FFRNS Section, FFRHS Branch, Region II Approved by:
J.
P. Potter,
- Chief, FFQIS Section FFRMS Branch, Region II SUMHARY Ins ection Dates:
November 26-28 1979 visit to Chem-Nuclear Waste dis osal site Barnwell South Carolina for unannounced ins ections of licensee-shi er Areas Reviewed:
Each licensee-shipper vehicle was inspected for com-pliance with Department of Transportation (DOT) and Nuclear Regulatory Commission (NRC) regulations as follows:
(1) shipping paper require-ments; (2)
DOT Placarding requirements; (3) radiation levels; (4) re-movable contamination; (5)
DOT marking and labeling requirements for packages; and (6)
DOT and NRC requirements for package external features'esults:
Of the six areas inspected involving 29 shipments, no items of noncompliance were identified' 80O4040~
I g
DETAILS Persons Contacted D. Ebenhack, Chem-Nuclear
- Systems, Inc.
J. Ott, Chem-Nuclear
- Systems, Inc.
V. Autry, South Carolina Department of Health D. McGlohorn, South Carolina Department of Health R. Bluemle, South Carolina Department of Health General The NRC inspection consisted of a review of the shipping papers, radiation survey of the vehicle, contamination surveys and radiation level surveys of selected packages.
General surveys and observations were conducted to deter-mine if the vehicle had proper placards, proper seals, and if any obvious safety hazards existed.
The contents of the vehicles were inspected for appropriate
- marking, labeling, tightness of seals, integrity of package construction or any evidence of leakage.
Chem-Nuclear assigns a control number for each shipment upon arrival at the site.
These numbers were called "shipment survey report numbers" (SSR No.),
and were used by the inspectors to identify the licensee-shipper during this inspection.
Shipments Inspected Twenty-nine (29) shipments were inspected during the period of November 26 to November 28, 1979.
A listing of the shippers inspected and their assigned SSR number is included as Attachment A.
Shipping Papers The shipping papers were reviewed for completeness and to ascertain if the contents of the shipment were properly identified, and if emergency notifi-cation procedures and instructions were included as required under 49 CFR 172, Subpart C.
Specific requirements for shipping papers were reviewed as follows:
Naterial shipping name Naterial class Name sequence Total quantity (volume)
Limited quantity Name of each radionuclide Physical and chemical form Activity in curies Category or label Notation of NRC/ERDA package approval Proper certification 49 CFR 172.100/172.200/172.202 49 CFR 172.200/172.202 49 CFR 172.200/172.202 49 CFR 172.200/172.202 49 CFR 172.200/172.203 49 CFR 172.203 49 CFR 172.203 49 CFR 172.203 49 CFR 172.203 49 CFR 172.203 49 CFR 172.204
In addition to the above, 49 CFR 177.817 requires carriers to maintain the above shipping papers readily available for inspection and recognizable by authorities in case of an accident.
No items of noncompliance were identified.
5.
Each vehicle was inspected for conformance with DOT placarding requirements (49 CFR 172, Subpart F and 49 CFR 173.392).
The vehicles were also inspected for compliance with the following:
Maximum transportation index of 50 - (49 CFR 177.842)
Loaded so as to avoid spillage (49 CFR 177.842)
Properly blocked and braced (49 CFR 173.392/177.842)
LSA vehicle survey (49 CFR 177.843)
No items of noncompliance were identified.
6.
Maximum Radiation Levels Each truck was surveyed for maximum radiation levels in the normally occupied portions of the vehicle, in a plane at the edge of the flat bed or at the surface of the closed vehicles, in a vertical plane six feet from the sides of the vehicle where possible, and on the surface of a representative package.
Shipping casks were surveyed at the surface.
No levels were in noncompliance with 49 CFR 173.393 limits.
7.
Contamination Smears Each vehicle and a representative sample package was surveyed for removable contamination by smearing over a 300 square centimeters area of the surface.
No more than two smears were taken from any package or vehicle.
Smears were taken from areas that would most likely be contaminated.
The smears were checked for gross Beta-gamma contamination at the site.
'8.
No smears were found to be contaminated in excess of 49 CFR 173.397 limits.
Packaging A representative sampling of packages from each shipment was examined for conformance with DOT marking and labeling requirements.
External features of the packages were examined for conformance with DOT and NRC requirments as noted below:
Low specific activity (LSA) packaging Tight packages
- Ltd. Qty.,
No release of material Radioactive material markings Security seals 49 CFR 173.392 49 CFR 173.391 or 173.392 49 CFR 173.392/173.393 49 CFR 172.310 49 CFR 173.393
Gross weight requirement@
Proper shipping name LSA labeling Cask design specifications 49 CFR 172.310 49 CFR 172.100/172.300 49 CFR 173.392 49 CFR 173.38 No items of noncompliance were identified.
0.
Verification of Package Contents Due to the lack of facilities for properly opening packages at the site, the criteria for opening packages was restricted to those packages containing solidified waste (to verify the absence of free-standing water) and/or where there was evidence of leakage or poor quality or damaged packaging.
One package was selected for opening.
South Carolina officials were present and concurred in the opening of the packages.
No items of noncompliance were noted'
I I