ML17318A259

From kanterella
Jump to navigation Jump to search
Forwards LERs 79-042/03L-0 & 79-043/03L-0
Date released: 05/31/2018 Download: ML17318A259


LER 79-043/03L-0:on 790201,axial Power Distribution Monitoring Sys Detector Alarm Setpoint Was Set Nonconservatively.Setpoint Reset.Personnel Received Addl Training
ML17318A261
Person / Time
Site: Cook 
Issue date: 09/13/1979
From: Rischling J
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17318A261 (9)
LER 79-042/03L-0:on 790814,pressurizer Pressure Transmitters Isolated.Caused by Instrument Drift.Investigation in Progress.Transmitters Recalibr
ML17318A260
Person / Time
Site: Cook 
Issue date: 09/13/1979
From: Rischling J
INDIANA MICHIGAN POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17318A260 (2)
Forwards LERs 79-042/03L-0 & 79-043/03L-0
ML17318A258
Person / Time
Site: Cook 
Issue date: 09/13/1979
From: Shaller D
INDIANA MICHIGAN POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML17318A258 (2)