DOCKET ¹ 05000335 05000389
SUBJECT:
Forwards "1991 Annual Operating Rept St Lucie Units 1
a 2" "1991 St Lucie Unit 1 Steam Generator Inservice Insp Rept,"
per TSs 6.9.1.4
& 4.4.5.5,respectively.
DISTRIBUTION CODE:
A047D COPIES RECEIVED:LTR J ENCL l SIZE:
+
TITLE: OR Submittal: Inservice Inspection/Testing/Relief from A E Code NOTES:
ACCELERATED DISTRIBUTION DEMONSTPWTION SYSTEM REGULATE INFORMATION DISTRIBUTIONO'STEM (RIDE)
E~'CCESSION NBR:9203030210 DOC.DATE: 92/02/25 NOTARIZED:
NO FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power 6
ight Co.
50-389 St. Lucie Plant, Unit 2, Flori'da Power Light Co.
AUTH.NAME AUTHOR AFFILIATION SAGER,D.A.
Florida Power 6 Light Co.
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Docqfaent Cont ol Desk)
RECIPIENT ID CODE/NAME PD2-2 LA NORRIS,J INTERNAL: ACRS NRR/DET/EMEB 7E 0
B EG FIL 01 EXTERNAL: EGSG BROWNFB NRC PDR COPIES LTTR ENCL 1
0 2
2 Sl I/'
3.
1 0
1' 1
1 1
1 1
RECIPIENT ID CODE/NAME PD2-2 PD NRR/DET/ECMB 9H NUDOCS-ABSTRACT OGC/HDS3 RES MILLIMANFG EG6tG 'ANSOME F C NSIC COPIES LTTR ENCL 1
'1 1
1 1
1 1
0 1
1 1
1 1
1 NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM PI-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR Cl ENCL 45 8
('7
P.O. Box 120, Ft. Pierce, FL 34954-0128 February 25, 1992 L-92-44 10 CFR 50.36 U. S. Nuclear Regulatory Commission Attn:
Document Control Desk Washington, DC 20555 Gentlemen:
Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 1991 Annual Operating and Steam Generator Inservice Ins ection Re ort Pursuant to Technical Specification 6.9.1.4, the 1991 Annual Operating Report for St. Lucie Units 1 and 2 is attached.
- Also, pursuant to Technical Specification 4.4.5.5, the 1991 Steam Generator Inservice Inspection Report for St.
Lucie Unit 1 is attached.
Very truly yours, b ~
DAN'wRAAager Vice President St. Lucie Plant DAS:JJB:kw cc:
Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachments DAS/PSL N625-92 (3gOO4()
9203030210 920225 PDR ADOCK 05000335 R
/~vs E/g
9203030210 1991 ANNUAL OPERATING REPORT ST ~ LUCIE UNITS 1 AND 2 AND 1991 ST ~ LUCIE UNITS 1 STEAM GENERATOR IN-SERVICE INSPECTION REPORT
TABLE OP CONTENTS Section 1
Annual 10 CFR 50.59 Report Section 2
Steam Generator In-Service Inspection Section 3
Mangrove Study Section 4
Personnel Exposure Summary Section 5
Chemistry Summary