-3-

IV. Pla tSu

o

R1

Radiological Protection and Chemistry (RP&C) Controls

R1.1

x

mal Ex osur

on r

I

Ins

i n

co e

75

The inspector interviewed radiation protection personnel and reviewed the following:

Control of high radiation areas

High radiation area key control

Radiological posting

Radiation work permits

Radiological controlled area access controls

Dosimetry use

b.

b

rv

io

a d 'di

s 83750

One of the requirements of Technical Specification 5.7.2.a is that each entryway to areas

with dose rates greater than

1 rem per hour be provided with a locked door, locked gate,

or guard that prevents unauthorized entry. The licensee designated areas with dose

rates greater than

1 rem per hour as high high radiation areas.

On October 6, 1997, the senior resident inspector identified a high high radiation area

that was not locked and not guarded.

The area was the radwaste liner storage room on

the 437-foot elevation of the radwaste building. Before securing the area gate with a pad

lock and chain, a radiation protection technician failed to ensure that the chain passed

through both the gate and a chain-link fence.

Therefore, even though the pad lock was

closed, the gate was not secured.

Second-person

verification that the area was properly

secured was not performed promptly. The licensee determined the area was unlocked

for approximately 70 minutes.

The radiation dose rates within the area were as high as 3 rems per hour. However,

because of the low occupancy of the area, the time required to exceed regulatory dose

limits, and the required use of electronic, alarming dosimeters by individuals entering the

radiological controlled area, the inspector concluded that the potential for individuals

exceeding regulatory dose limits was not substantial.

The failure to provide an area with

dose rates greater than

1 rem per hour with a locked door, locked gate, or guard was a

violation of Technical Specification 5.7.2.a (50-397/9719-01).

NRC Inspection Report

50-397/95-30 described similar violations, occurring May 7 and August 8, 1995. The

licensee initiated Problem Evaluation Request 297-0807 to document the problem and

track corrective actions.

980i230i64 980ii6

PDR

ADQCK 05000397

6

PDR

-5-

examples listed. The inspector identified the four examples,

in which no evaluations

were performed on individuals with potential internal contamination, as a violation of

10 CFR 1501(a) (50-397/9719-02).

After reviewing the licensee's implementing procedures applicable to this situation, the

inspector concluded that a possible cause for the violation was the use of a poorly

worded or illogicallyconstructed procedure.

This is discussed

in Section R3.

The radiation protection manager stated, during a telephone conversation on

December 5, 1997, that, since the onsite portion of the inspection, radiation protection

representatives

reviewed the personnel contamination event Iog and identified two

additional individuals who had not been provided whole-body counts.

Allsix individuals

were contacted and provided whole-body counts.

No significant intakes of radioactive

material were identified. However, more than 6 months had elapsed since the

identification of the earliest example.

Therefore, it might have been difficultfor the

licensee to identify the presence of radionuclides with short effective half-lifes, ifthey had

been taken internally.

c.

Qggclu~s'ons

A violation involving the failure to evaluate radiological hazards associated'with potential

intakes of radioactive material was identified.

R1.3

I'0

i

iv

M

ri

I

d

mi

i

e in

n

M ni ori

a.

In

c'7

0

The inspector interviewed radiation protection personnel and reviewed the following:

Release of items from the radiological controlled area

Sealed radioactive source accountability

Sealed radioactive source leak testing

Personnel contamination events

Portable survey instrument calibration

Whole-body counter calibration

Ob erv

ion

and Findin s

Con rol f R dioac ive Material

During a review of problem evaluation requests, the inspector noted that the licensee

identified minor problems involving the release of radioactive materials from the

radiological controlled area in December 1996 and May 1997. The inspector observed

radiation protection technicians as they performed radiation surveys and released items

from the radiological controlled area.

No problems were identified. Items released

unconditionally were recorded in the licensee's material release log.

SUPPLEMENTAL IN 0

MAT0

T AL L S 0

PERSO

S CONTACTED

~Li ~nse

D. Atkinson, Quality Manager

P. Bemis, Vice President Nuclear Operations

I. Borland, ALARA/Health Physics Support Supervisor

D. Hillyer, Radiation Protection Manager

P. Inserra, Licensing Manager

J. Liles, Health Physics Operations Supervisor

M. Shepherd,

Health Physics Operations Supervisor

G. Smith, Plant General Manager

R. Webring, Vice President Operations Support

S. Boynton, Senior Resident Inspector

G. Johnston, Senior Project Engineer

INSPECTION PROCED

RES USED

83750

Occupational Radiation Exposure

0 ene

E

S OPENED CLOSED AND DISCUSSED

50-397/9719-02

VIO

Failure to control access to areas with radiation dose rates

greater than

1 rem per hour

50-397/9719-02

VIO

Failure to evaluate radiological hazards related to potential

internal contaminations

Closed

50-397/9530-01

VIO

Failure to control access to areas with radiation dose rates

greater than

1 rem per hour

Discussed

NONE