Text
~I<<REGS
~ (4
+N
~o Cy O
<<h0
~O
+a*++
~
~
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2055&4001 August 18, 1997 Mr. J.
V. Parrish Chief Executive Officer Washington Public Power Supply System PRO.
Box 968 (Mail Drop 1023)
Richland.
Washington 99352-0968
SUBJECT:
EVAI UATION OF SECOND TEN-YEAR INTERVAL INSERVICE INSPECTION PROGRAM PLAN RELIEF REQUEST 2-ISI-15 FOR THE WASHINGTON PUBLIC POWER SUPPLY SYSTEM (WPPSS)
NUCLEAR PROJECT NO. 2 (WNP-2)
(TAC NO.
M93905)
Dear Mr. Parrish:
By letter dated October 6,
1995.
WPPSS submitted proposed relief request 2-ISI-15 associated with its second ten-year inservice inspection (ISI) interval for WNP-2.
The licensee requested relief from Category C-G pump casing weld inspection requirements for residual heat removal (RHR) pumps RHR-P-2A, -2B, and -2C, and high pressure coolant system (HPCS) pump HPCS-P-l, and low pressure coolant system (LPCS) pump LPCS-P-1.
By letter dated May 19.
- 1997, WPPSS provided additional information in response to a March 31,
- 1997, NRC staff request.
Specifically. the licensee proposed alternative examinations to perform surface examinations for areas accessible from the outside surface in accordance with the Code and examination of welds internal to pumps when disassembled f'r maintenance.
In accordance with 10 CFR 50.55a(g)(6)(i), the licensee submitted this request based on the hardship it stated would exist if the licensee had to disassemble the pumps for the sole purpose of performing this inspection.
The staff has reviewed the WPPSS request and determined that compliance with the specified requirements would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
Therefore, pursuant to 10 CFR 50.55a(a)(3)(ii). the proposed alternative examination is authorized.
The details of our review are contained in the enclosed Safety Evaluation.
9708250204 5000397 pDR gDQCK 0 8
9 p Qg<<l C
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
I
% ~
~
f l'
"I E
Mr. J.
V. Parrish, -, - 2 '-,
I If you have any questions.
please contact Timothy G. Colburn. Senior Project Manager,, at (301) 415-1341 S'incerely',
Docket No. 50-397
Enclosure:
Safety Evaluation cc w/encl:
See next page Orig>nal signed by 3.
Hannon for:
William H. Bateman, Director Project Directorate IV-2 Division of Reactor Projects
- III/IV Office of Nuclear Reactor Regulation DISTRIBUTION:
Docket File PUBLIC PDIV-2 Reading JRoe EAdensam WBateman TColburn EPeyton ACRS
- OGC, 015B18
- KPerkins, RIV/WCFO
- PGwynn, RIV
- HWong, RIV/WCFO GHill (2)
THi 1 tz DOCUMENT NAME: WNP93905.REL OFC PDIV-2/PM PDIV-2/LA TColburn:ye EPdyyo%
OGC<~
PDIV-2/D EM8w~n n
WBateman DATE 8/6/97 8/6'/97 8/A/97 I IAL R Snf)97
Mr. J.
V. Parrish If you have any questions.
please contact Timothy G. Colburn. Senior Project Manager. at (301) 415-1341.
Sincerely.
Docket No. 50-397
Enclosure:
Safety Evaluation cc w/encl:
See next page William H. Bateman.
Director Project Directorate IV-2 Division of Reactor Projects
- III/IV Office of Nuclear Reactor Regulation
Nr. J.
V. Parrish cc w/encl:
Nr. Greg 0. Smith (Nail Drop 927M)
WNP-2 Plant General Manager Washington Public Power Supply System P. 0.
Box 968 Richland.
Washington 99352-0968 Hr. Albert E. Mouncer (Mail Drop 1396)
Chief Counsel Washington Public Power Supply System P.O.
Box 968 Richland.
Washington 99352-0968 Hr. Frederick S. Adair, Chairman Energy Facility Site Evaluation Council P. 0.
Box 43172 Olympia. Washington 98504-3172 Nr. David A. Swank (Mail Drop PE20)
- Manager, Regulatory Affairs Washington Public Power Supply System P.O.
Box 968
- Richland, Washington 99352-0968 Nr. Paul Inserra (Hail Drop PE20)
- Manager, Licensing Washington Public Power Supply System P.OS Box 968
- Richland, Washington 99352 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower 8 Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Chairman Benton County Board of Commissioners P.O.
Box 69
- Prosser, Washington 99350-0190 Nr. Rodney L. Webring (Mail Drop PE08)
Vice President, Operations Support/PIO Washington Public Power Supply System P. 0.
Box 968
- Richland, Washington 99352 Hr. Scott Boynton. Senior Resident Inspector U.S.
Nuclear. Regulatory Commission P.O.
Box 69
- Richland, Washington 99352-0968 Hr. Perry D. Robinson, Esq.
Winston 5 Strawn 1400 L Street, N.W.