1 NRR-PMDAPEm Resource From:
Regner, Lisa Sent:
Wednesday, October 18, 2017 4:16 PM To:
Jerry.Humphreys@dep.nj.gov Cc:
Parker, Carleen; Ronewicz, Lynn
Subject:
Notification of Amendment to the Hope Creek Generating Station License and Request for Comments Good Afternoon, Mr. Humphreys.
I enjoyed speaking with you today. Im contacting you to let you know about an amendment to the operating license for Hope Creek that the NRC is close to issuing. We expect to issue in the next 3 weeks (prior to November 10).
Hope Creek has request to modify its license in accordance with new NRC-approved guidance to allow the extension of the Type A reactor containment testing interval from one test in 10 years to one test in 15 years; and extension of the Type C test interval up to 75 months. More details are below, but feel free to contact me if you have any comments or questions.
Thanks for your time, Lisa Regner This amendment consists of changes to the Technical Specifications (TSs) in response to an application dated October 7, 2016, as supplemented by letters dated March 27, and July 13, 2017. The amendment modifies the HCGS TS 6.8.4.f Primary Containment Leakage Rate Testing Program by deleting the exemption in item a.
that allowed a one-time extension (by letter dated April 16, 2003), and requiring compliance with Nuclear Energy Institute (NEI) topical report NEI 94-01, Revision 3-A, Industry Guideline for Implementing Performance-Based Option of 10 CFR [Title 10 of the Code of Federal Regulations] Part 50 Appendix J, instead of Regulatory Guide 1.163 Performance-Based Containment Leak-Test Program. This change will allow HCGS to extend the Type A reactor containment test interval, required by 10 CFR Part 50 Appendix J, from one test in 10 years to one test in 15 years, and extension of the Type C test interval up to 75 months, with a permissible extension period of 9 months (total of 84 months) for non-routine emergency conditions.
Lisa M. Regner Senior Project Manager Branch 4, Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Lisa.Regner@NRC.gov 301-415-1906 OWFN 9D14
Hearing Identifier:
NRR_PMDA Email Number:
3779 Mail Envelope Properties (0702cf2d121b45b29864f3b89f822123)
Subject:
Notification of Amendment to the Hope Creek Generating Station License and Request for Comments Sent Date:
10/18/2017 4:15:51 PM Received Date:
10/18/2017 4:15:52 PM From:
Regner, Lisa Created By:
Lisa.Regner@nrc.gov Recipients:
"Parker, Carleen" <Carleen.Parker@nrc.gov>
Tracking Status: None "Ronewicz, Lynn" <Lynn.Ronewicz@nrc.gov>
Tracking Status: None "Jerry.Humphreys@dep.nj.gov" <Jerry.Humphreys@dep.nj.gov>
Tracking Status: None Post Office:
HQPWMSMRS01.nrc.gov Files Size Date & Time MESSAGE 1988 10/18/2017 4:15:52 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: