ML17291B021

From kanterella
Jump to navigation Jump to search

Forwards SE Re Applicability of Topical Rept NEDO-32205,rev 1, 10CFR50 App G,Equivalent Margin Analysis for Low Upper Shelf Energy in BWR/2 Through BWR/6 Vessels
ML17291B021
Person / Time
Site: Columbia 
Issue date: 09/15/1995
From: Clifford J
NRC (Affiliation Not Assigned)
To: Parrish J
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
Shared Package
ML17291B022 List:
References
TAC-M90064, NUDOCS 9509210305
Download: ML17291B021 (3)


Text

.Hr. J.

V. Parrish (HaDrop 1023)

Vice President Nuclear Operations 3000 George Washington Way Washington Public Power Supply System P.O.

Box 968

Richland, Washington 99352-0968 September 15, 19o5

SUBJECT:

APPLICABILITY OF GENERAL ELECTRIC TOPICAL REPORT, NED0-32205, REVISION 1, TO THE WASHINGTON PUBLIC POWER SUPPLY SYSTEM (WPPSS)

NUCLEAR PROJECT NO.

2 (WNP-2)

(TAC NO. M90064)

Dear Hr. Parrish:

In a letter dated July 28, 1994, the Supply System submitted for staff review and approval its assessment of the applicability to the WPPSS Nuclear Project, Unit 2 (WNP-2) reactor vessel of the General Electric Topical Report, NEDO- : 32205, Revision 1,

"10 CFR 50 Appendix G, Equivalent Margin Analysis for Low Upper Shelf Energy in BWR/2 Through BWR/6 Vessels."

We have completed our review of your submittal.

We concluded that the analyses in NEDO-32205 are applicable to the WNP-2 reactor vessel.

We further concluded that the WNP-2 reactor vessel will provide margins of safety against fracture equivalent to those required by Appendix G of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code at the expiration of the WNP-2 license, as required by Appendix G,

10 CFR Part 50 for reactor vessels with upper-shelf energy less than 50 ft-lb.

Our evaluation is provided in the enclosure.

When the first surveillance capsule is withdrawn from the reactor vessel, which.we understand is currently scheduled for the spring 1996 refueling

outage, we request that you evaluate the test results from the surveillance material to determine whether the analyses in NEDO-32205 are applicable to the WNP-2 reactor vessel material.

We also request that you provide the results of this assessment to the NRC when you submit the'surveillance test report that is required in Appendix H to 10 CFR Part 50.

Please contact me at 301-415-1352 if you have any questions.

(

95092i0305 9509l5 PDR ADQCK 05000397 P

PDR Docket No. 50-397 Sincerely, Original Signed By

.James W. Clifford, Senior Project Manager Project Directorate IV-2 Division of Reactor Projects - III/IV Office of Nuclear Reactor Regulation DISTRIBUTION:

Enclosure:

Safety Evaluation cc w/ encl:

See next page DOCUMENT NAME: WNP90221.LTR

'ocket File

PUBLIC, EAdensam JRoe WBateman JClifford EPeyton ACRS(4),

TWFN PDIV-2 Reading

OGC, 015818 KPerkins,'CFO
JDyer, RIV
HWong, RIV RWessman OFC PDIV-2/LA PDIV-2/PH NAME e

on JCl ord:pk DATE 1 /I"f/95 I /'lg/95 OF ICIAL RECORD COPY

IP h

) ~i(

tp l'J

Hr. J.

V. Parrish September 15, 1995 cc w/encl:

Mr. J.

H. Swailes WNP-2 Plant General Manager Washington Public Power Supply System P. 0.

Box 968

Richland, Washington 99352-0968 Chief Counsel (Mail Drop 396)

Washington Public Power Supply System P.O.

Box 968

Richland, Washington 99352-0968 Mr. Frederick S. Adair, Chairman Energy Facility Site Evaluation Council P. 0.

Box 43172 Olympia, Washington 98504-3172 Hr. D. A. Swank (Hail Drop PE20)

WNP-2 Licensing Manager Washington Public Power Supply System P.O.

Box 968

Richland, Washington 99352-0968 Hr. Paul R. Bemis (Mail Drop PE20)

Director, Regulatory and Industry Affairs Washington Public Power Supply System P.O.

Box 968 Il

Richland, Washington 99352 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Harris Tower

& Pavilion 611 Ryan Plaza Drive, Suite 400 Arlington, Texas 76011-8064 Chairman Benton County Board of Commissioners P.O.

Box 69

Prosser, Washington 99350-0190 Hr. R.

C. Barr, Senior Resident Inspector U.S. Nuclear Regulatory Commission P,O.

Box 69

Richland, Washington 99352-0968 M. H. Philips, Jr.,

Esq.

Winston

& Strawn 1400 L Street, N.W.

Washington, DC 20005-3502