Forwards Request for Addl Info Which Needed to Complete Response to Bulletin 90-01,Suppl 1, Loss of Fill-Oil in Transmitter Manufactured by Rosemount
ML17290B046
Person / Time
Site: Columbia 
Issue date: 03/24/1994
From: Clifford J
Office of Nuclear Reactor Regulation
To: Parrish J
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
References
IEB-90-001, IEB-90-1, TAC-M85462, NUDOCS 9403300040
Download: ML17290B046 (7)


Text

'ocket No. 50-397 Hr. J.

V. Parrish (Mail Drop 1023)

Assistant Managing Director, Operations Washington Public Power Supply System P.

0.

Box 968

Richland, Washington 99352-0958

Dear Hr. Parrish:

March 24, 1994

SUBJECT:

RE(VEST'OR ADDITIONAL INFORMATION REGARDING NRC BULLETIN 90-01, SUPPLEMENT '1,

'"LOSS OF FILL-OIL IN TRANSMITTERS MANUFACTURED BY ROSEHOUNT" (TAC H85462)

You provided a response to NRC'Bulletin 90-01, Supplement 1, in a letter dated March 8; 1993.

We have completed our'eview of your response.

Enclosed is a

request for additional information that, we need to complete our evaluation of your response to the Bulletin.

You are requested to provide your response within 60 days of the date of this letter.

Please contact me if you have any questions.

Sincerely, Original signed by:

James W. Clifford, Senior Project Manager Project Directorate V

Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/enclosure:

See next page DISTRIBUTION Docket File NRC & Local PDRs PDV R/F JRoe EAdensam Tguay JClifford OGC (15B18)

KPerkins, RV JWermiel (8H3)

DSpaulding (8H3)

ACRS (10)

(P-315)

OFC NAME DATE LA:PDV:DRPW DFoster-Curse n

PH'PD

'D PW JClifford:mk

/z>/ 0'f D:PDV:DRPW TQuay

'Z/P/ qg OFFICIAL RECORD COPY DOCUMENT NAME:

A:iWNP85462.RAI

&Qt'403300040 940324%

PDR ADQCK 05000397 P

PDRQ li%C~ C8@BI >>

I fy il I'

~

~I ~ ~<00

'8

~C Wp0 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 2055&0001 March 24, 1994 Docket No. 50-397 Mr. J.

V. Parrish (Hail Drop 1023)

Assistant Managing Director, Operations Washington Public Power Supply System P.

0.

Box 968

Richland, Washington 99352-0958

Dear Hr. Parrish:

SUBJECT:

RE(UEST FOR ADDITIONAL INFORMATION REGARDING NRC BULLETIN 90-01, SUPPLEMENT 1, "LOSS OF FILL-OIL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT" (TAC M85462)

You provided a response to NRC Bulletin 90-01, Supplement 1, in a letter dated March 8, 1993.

We have completed our review of your response.

Enclosed is a

request for additional information that we need to complete our evaluation of your response to the Bulletin.

You are requested to provide your response within 60 days of the date of this letter.

Please contact me if you have any questions.

Sincerely,

Enclosure:

As stated cc w/enclosure:

See next page es W. Cliffor, Senior Project Manager Project Directorate V

Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Enclosure RE UEST FOR ADDITIONAL INFORMATION J

WASHINGTON PUBLIC POWER SUPPLY SYSTEM

RESPONSE

TO NRC BULLETIN 90-01 SUPPLEMENT 1

LOSS OF FILL-OIL IN TRANSMITTERS MANUFACTURED BY ROSEMOUNT WASHINGTON NUCLEAR POWER PLANT UNIT 2 Per the Requested Actions and Reporting Requirements delineated in Supplement 1 to NRC Bulletin 90-01, the following additional information is requested:

1.

The licensee should inform the NRC (in writing) when the actions committed to have been completed.

2.

The licensee should provide the monitoring frequency committed to for the Rosemount transmitters discussed in response to Requested Action 1d.

3.

4.

It is not clear from the licensee's response to Requested Action le and 1f if the licensee's intent is to commit to indefinitely maintaining the Rosemount transmitters in the enhanced surveillance monitoring program.

The licensee stated in response to Requested Actions le and 1f that monitoring of the transmitters would continue under the enhanced surveillance program.

However, there was no mention of when this continued program would end or what would occur once the program was ended.

Requested Actions Ie and 1f ask that licensees maintain the ability to detect failures due to fill-oilloss.

This commitment is for an indefinite timeframe.

The licensee has the option of excluding the transmitters from the enhanced monitoring program, in which case they would need to utilize some means to detect failures due to fill oil loss'f the licensee's intent is not to commit to indefinitely maintaining the transmitters in the enhanced surveillance monitoring program (ESMP), then they need to provide discussion on how they will maintain the ability to detect failures due to fill-oilloss.

The licensee's response to Bulletin 90-01, Supplement 1 indicates that:

"After consultation with Rosemount, it was determined that two decimal places in our calibration was required to provide an accuracy range consistent with that needed for comparison with manufacturer drift criteria.

Our program utilizes two decimal place calibration data."

It is not clear that the above statement constitutes an acceptable enhanced monitoring program that can detect leakage in accordance with provisions of the Bulletin.

Additional discussion is needed describing the licensee's enhanced surveillance monitoring program.

The licensee should provide detailed information that would indicate how their ESMP follows Rosemount's recommendations.

4

~

~ <

0 Hr. J.

V. Parrish Washington Public Power Supply System WPPSS Nuclear Project No.

2 (WNP-2) cc w/enclosure:

Mr. J.

H. Swailes WNP-2 Plant Manager Washington Public Power Supply System P. 0.

Box 968

Richland, Washington 99352-0968 G.

E.

C. Doupe, Esq.

(Hail Drop 396)

Washington Public Power Supply System 3000 George Washington Way P. 0.

Box 968

Richland, Washington 99352-0968 Hr. Warren Bishop, Chairman Energy Facility Site Evaluation Council P. 0.

Box 43172 Olympia, Washington 98504-3172 Hr.

H. K. Kook (Mail Drop PE20)

WNP-2 Licensing Manager Washington Public Power Supply System P. 0.

Box 968

Richland, Washington 99352-0968 Hr. Paul R.

Bemis (Mail Drop PE20)

Regulatory Programs Manager Washington Public Power Supply System P. 0, Box 968

Richland, Washington 99352-0968 Regional Administrator, Region V

U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Chairman Benton County Board of Commissioners P. 0.

Box 190

Prosser, Washington 99350-0190 Mr. R.

C. Barr U. S. Nuclear Regulatory Commission P. 0.

Box 69

Richland, Washington 99352-0968 H.

H. Philips, Jr.,

Esq.

Winston 8 Strawn 1400 L Street, N.W.

Washington, D.C.

20005-3502

4