ML17290A730

From kanterella
Jump to navigation Jump to search
Forwards LER 93-029 Re Primary Coolant Steam Leak Discovered During Scram Recovery.Event Also Described in LER 93-027. Encl LER 93-029 Provides Separate Report,Per 10CFR50.73
Date released: 06/27/2018 Download: ML17290A730


LER 93-029-00:on 930805,discovered Primary Coolant Steam Leak.Caused by Weld Defect.Weld Crack Repaired on 930806. Weld Record for Applicable Weld Also Reviewed & No Discrepancies Identified
ML17290A731
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 11/05/1993
From: Fies C
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
References
Download: ML17290A731 (5)
Forwards LER 93-029 Re Primary Coolant Steam Leak Discovered During Scram Recovery.Event Also Described in LER 93-027. Encl LER 93-029 Provides Separate Report,Per 10CFR50.73
ML17290A729
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 11/05/1993
From: Parrish J
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML17290A729 (2)