{{#Wiki_filter:INSERVICE INSPECTION

SUMMARY

REPORT FOR REFUELING OUTAGE RF93A JULY l,l 2 TO JUNE I) 1 , 'DR

                                                                  ~
                                                                    .,9309240$ /g
                                                                          'DOCK   9309i6' 05000397
                                                                     'Q                PDR OWNER:                Washington Public Power Supply System 3000 George Washington Way Richland, Washington 99352 PLANT:                WNP-2, located 11 miles north of Richland, Washington on the U.S.

Department of Energy Hanford Reservation COMMERCIAL SERVICE DATE: December 13, 1984 CAPACITY: 1145 MWe REACTOR PRESSURE VESSEL: Manufacturer: CBIN Serial Number: T-45 State No.: 29936-84W Nat'1 Bd No.: 8 Prepared By: 8-3o- y3 ISI Engmeer Date Repair/Replacement En ineer Date Reviewed -Z-PS Concurred Supervisor, NDE<ISI Services Date By: Manager, Mate 'nd Inspection Date Manager, Engmee ng rograms D e Manag r, Techn al Services anager, Plant lity Assurance Date Appro y: Pl " ag r Date Concurre ce: Auth 'zed Nuc Inservice Inspector ate

ISI

SUMMARY

REPORT RF93A Table of Contents Cover Page and Approvals Page I Table of Contents Page 2 Examination Results Page 3 Repair/Replacements Page 9 Tables Table I Examinations Completed by Category Table II Snubber Testing Summary Table III Significant Indications Appendices A. NIS-1 Owners Data Report B. NDE Results C. Repair/Replacement Listing NIS-2 Data Reports

ISI

SUMMARY

REPORT RF93A

SUMMARY

WNP-2 has completed 91% of the first Inservice Inspection Interval requirements. The following Nuclear Regulatory Commission (Commission) augmented examinations were completed at R8: ultrasonic examination of RPV shell welds, pipe break exclusion areas (high energy lines), core spray spargers, and jet pump beams. WNP-2 is on schedule with its Generic Letter 88-01 commitments. No change was found in weld 20RRC(6)-8 indication (identified during R6). EXAMINATIONRESULTS This report summarizes the results of Inservice Inspection (ISI) of ASME Class 1,2 and 3 components and supports performed at Washington Public Power Supply System (Supply System) Nuclear Plant No. 2 (WNP-2) between July 19,1992 and June 21, 1993. Both General Electric (GE) and Supply System personnel performed the examinations. During this period, WNP-2 completed the eighth scheduled refueling outage, RF93A (R8). This report includes the NIS-1 Owner's Report of Inservice Inspection. A copy can be found in Appendix A. The ISI examinations are specified in ASME Section XI and required by 10CFR50.55a. In addition, the following examinations were performed to meet augmented Nuclear Regulatory Commission requirements. o Ultrasonic examination of RPV shell welds per 10CFR50.55a dated August 6, 1992. o Pipe break exclusion areas (high energy lines penetrating containment, but not within ASME Section XI examination boundary) o IGSCC (intergranular stress corrosion cracking) detection in stainless steel welds, based on Generic Letter 88-01. o Visual examination of core spray spargers and supply piping in RPV o Ultrasonic and visual examinations of jet pump beams The ASME Section XI examinations comply with the 1980 Edition, Winter 1980 Addenda upgraded as follows: o IWA-2300(a)(1), 1983 Edition, Winter 1983 Addenda o Code category C-F, 1983 Edition, Winter 1983 Addenda o IWF-3400, 1980 Edition Winter, 1981 Addenda o IWB-3600, 1986 Edition no Addenda (to comply with GL88-01) ISI

SUMMARY

REPORT RF93A Documentation supporting this summary report is located in the WNP-2 Operations File (DIC 1100). Table I lists all ASME Section XI and augmented examinations completed during R8. Appendix B contains a more detailed summary of the results by system and ISI drawing. The ISI drawings referenced are included in the ISI Program Plan previously submitted to the Commission. The examinations, tests, repairs and replacements were witnessed or verified by Authorized Nuclear Inservice Inspector (ANII) D.E. Hoggarth. He is employed by Factory Mutual Engineering Association, a subsidiary of Arkwright Mutual Insurance Company, Norwood, Massachusetts. COMPONENTS EXAMINED The following component was examined: Serial National Component Manufacturer Number Board No. RPV CBIN Nuclear T-45 2700 Channel Ave Memphis, TN PIPING EXAMINATIONS o See Generic Letter 88-01 summary below under "AUGMENTED EXAMINATIONS" for further details. o Two hundred forty seven (247) Class 1 and 2 examinations were completed by UT, PT or MT methods. RPV EXAMINATIONS o Interior visual examinations were performed by General Electric and Supply System personnel. Various augmented items were examined. See augmented examination section below for further details. No unacceptable indications were found. o RPV welds were examined by GE using their GERIS examination system and manual scanning. The RPV weld ultrasonic examinations were performed in accordance with ASME Section XI 1980 Edition Winter, 1980 Addenda, NRC Regulatory Guide 1.150 Revision 1 alternate method and 10CFR50.55a(g)(6)(ii)(A) (issued August 6, 1992). No unacceptable indications were detected. Full ASME Section XI Code coverage as defined in 10CFR50.55a(g)(6)(ii)(A) was not obtained on circumferential weld AB. 10- YEAR HYDROSTATIC TESTS The Supply System completed the 10-year hydrostatic tests and associated VT-2 examinations ISI

SUMMARY

REPORT RF93A on the following ASME Section III code class 3 systems: Fuel Pool Cooling Control Room Chilled Water Reactor Closed Cooling. No unacceptable indications were found. AUGMENTED EXAMINATIONS The Supply System performed augmented examinations per the ISI Program Plan section 5.3, "Mandatory Augmented Inservice Inspection". o High energy lines that penetrate containment (section 5.3.1) Dye penetrant or ultrasonic examination of 14 welds in the high energy line augmented examination program was performed. No reportable indications were found. This completes the augmented commitment for high energy lines for the first inspection interval. o LPCS weld thickness measurement(section 5.3.7) Thickness measurement of weld 16LPCS(1)-5 was completed. Results were forwarded to Engineering for review and determination of corrosion rate. o Core spray sparger and supply piping (section 5.3.5) A visual examination of the core spray spargers and their supply piping was performed per the requirements of IE Bulletin 80-13, "Cracking in Core Spray Sparger". The examination was performed using an underwater closed circuit TV system capable of resolving a 0.001 inch diameter wire in-situ. No relevant indications were observed. o Jet pump beam ultrasonic and visual examinations (section 5.3.3) The jet pump beams were ultrasonically and visually examined No reportable indications were found. o Feedwater nozzle examinations due to Final Feedwater Temperature Reduction (FFWTR) ("coastdown") One feedwater nozzle inner radius, bore and associated safeend were examined per commitments made in Supply System letter G02-90-024, dated February 14, 1990 and NRC SER dated March 1, 1990. No recordable indications were found. The safeend examined is a GL88-01 category "D" weld and was examined per Supply System commitments to GL88-01. I ISI

SUMMARY

REPORT RF93A o Notice of Violation (NOV) 92-20-01, dated September 1, 1992 Reference Supply System letter G02-92-230, dated October 1, 1992. In response to this NOV, the Supply System reexamined 17 welds using an axial notch calibration. No recordable indications were found. o Generic Letter 88-01 (section 5.3.4) 4 Five (5) category A welds, twenty-one (21) category B welds, one (1) category D weld and one (1) category "F" weld were examined. No recordable indications were found in category "A", "B" or "D" welds. The category "F" weld, 20RRC(6)-8, had a reportable indication detected at R6. The results of the R8 examination determined that the flaw size had not changed significantly from R6. The analysis performed at R6 for continued operation is still valid. The results of this examination and analysis for continued operation were submitted to the Commission for review and approval for continued operation.(ref. letter GO2-93-119, dated May 21, 1993) The Commission approved operation for one more cycle. (ref. letter dated June 11,1993, James W. Clifford to G.C. Sorensen, "Review of Inspection Report on a Flaw in Reactor Recirculation Piping at WNP-2") This weld will be examined again at R9 to determine any change in flaw size. Status of GL 88-01 commitment: Category

   +otal Required
                      ~ihi         'ihi Required             WNP-2 Status thru R8
                                                          ~Af 4 O.

A (57) 7 14 322 B (147) 37 74 52 Category

   ~Total Required within rs'NP-2                   ~After l Status thru R8 r

D (25) 25 Category Required WNP-2 Status thru R8

   $ Tota~l           ~within i rs                        ~After l r F

(1)'otes 1 WNP-2 commitment began at R4. 2 WNP-2 requirements exceed GL 88-01 because of ASME Section XI requirements. WNP-2 commitment began at R7 Completed as part of FFWTR commitment, see previous page. This category "F" weld was reclassified from category "B" at R6. ISI

SUMMARY

REPORT RF93A WNP-2 is on schedule with its GL 88-01 commitments. o Snubber testing (section 6.5) An initial sample of 37 snubbers was selected from the WNP-2 general population of 494 safety related snubbers. These snubbers were randomly selected by computer sub-routine which is paitnof the Snubber Test and Examination Program (STEP). The selected snubbers were then reviewed to determine if the sample was representative as required by Technical Specification 4.7.4.e. Testing of snubbers was performed using portable testing devices "Validators". These devices were supplied by the snubber manufacturer. Testing results summary is found in Table II, Snubber MD-1285-14A S/N 4011 passed the functional test, but there were some rub marks on the cylinder due to vibrations. To preclude further service life degradation it was replaced with another tested snubber S/N 2473. The next testing is required within 18 months. PRESERVICE INSPECTIONS Four CRD scram discharge volume welds received PSI surface examinations. The new branch connection welds were installed under Section XI repair/replacement plan 2-0878. The weld numbers are: Identificati n No. 8CRD(12) A-18/2FLG CRD-201 8CRD(12)A-22/2FLG CRD-201 8CRD(12)B-18/2FLG CRD-202 8CRD(12)B-22/2FLG CRD-202 LIMITED EXAMINATIONS Full ASME Section XI required coverage of the examination volume or surface could. not be accomplished on three (3) welds. Weld Ident. ~Descri tinn Descri tion of Limitations AB ¹1-¹2 SC CIRC WD Examination limited to 79.7% due to weld transition between plates. SW-123(W) WELDED ATTACHMT , Examination limited to 75% of welded attachments due to fire seal barrier. FPC-64(W) WELDED ATTACHMT Examination limited by fire seal barrier. ISI

SUMMARY

REPORT RF93A SIGNIFICANT INDICATIONS Significant indications found during ISI examinations are summarized in Table III. All significant indications were evaluated for continued operation. If unacceptable for continued operation they were repaired or replaced. Evaluation and/or re-examination data sheets are attached to the original data reports. ISI

SUMMARY

REPORT RF93A REPAIRS AND REPLACEMENTS Four (4) signiflcant ASME Section XI repair or replacement activities were performed during the RF93A refueling outage: 1) Modified vent/drain/test connections, 2) Installed flow elements (FE) and temperature elements (TE) in the service water (SW) system, 3) Installed flush connections in the scram discharge volume (SDV) system and 4) Replaced disc inserts and nozzles for four (4) main steam relief valves and replaced two (2) main steam relief valves. A listing and NIS-2 Owner's Reports for these and other ASME Section XI repair or replacement work accomplished and closed out between July 19, 1992 and June 21, 1993 are provided in Appendix C.

1) Vent rain est Connections Modified seven (7) vent/drain/test connections for RHR, LPCS, HPCS, FPC systems and process instrument line to reduce susceptibility to fatigue induced failures at socket welds.
2) Service Water S S stem Installed thermowells for temperature measurements and annubae flow elements for flow measurements in the service water system.
3) Scram Dischar e Volume SD S stem Installed flush connections in both the scram discharge volumes to allow access for water or chemical flushing of the system.
4) Main Steam MS S stem Refurbished four (4) main steam relief valves with Serial Numbers N63790-00-0046, N63790-00-0057, N63790-00-0120 and N63790-00-0122. These refurbished main steam relief valves were installed in place of the existing main steam relief valves in the plant.

Refurbished and reinstalled three (3) main steam relief valves with Serial Numbers N63790-00-0049, N63790-00-0053 and N63790-00-0126. ISI

SUMMARY

REPORT RF93A Table I Examinations Completed by Category Notes to Table I (1) Examination did not cover full Code examination surface or volume (2) Examined for FFWTR commitment dated March 1, 1990 (3) Examined washers for RPV studs 7A, 14A, 21A, 28A, 35A, 42A, 49A, 56A, 63A, 70A (4) Examined with axial notch calibration for NOV 92-20-01 (5) Relief Request 2-ISI-001 accepted reduced examination volume for this weld (6) Jet pump beam commitment, ISI Program Plan section 5.3.3 (7) Jet pump sensing lines commitment, OER 85039B (8) Core spray sparger commitment, ISI Program Plan section 5.3.5 (9) LPCS weld thickness measurement commitment, ISI Program Plan section 5.3.7 (10) RWCU thermal sleeve commitment, IOM EES-DPR-85-16, dated 8/12/85 (11) CSP nitrogen cracking commitment, OER 84012C

0 TABLE I EXANI NATIONS COMPLETED DURING OUTAGE RF93* CODE CATEGORY IDENTIFICATION NO. DESCRIPTION IS I DRAWING METHOD EXAN DATE NOTES AUG I'IT 24RFW (1) A-1A PIPE TO VALVE RFW-101 VOL 19930508 24RFW (1) B-lA PIPE TO VLV RFW-102 VOL 19930511 6RMCU(3) 28A WOL TO PIPE RWCU-301 SUR 19930526 6RWCU (3) -28B WOL TO THN SLV RWCU-301 SUR 1 9'930526 6RWCU(3) -28C THN SLV TO CAP RWCU-301 SUR 1 9'930526 6RIJCU(3) -28D CAP TO PIPE RMCU-301 SUR 19930526 6RMCU(3) -33 PIPE TO TEE RWCU-301 VOL 19'930524 6RWCU(3) -34 TEE TO REDUCER RlJCU-301 VOL 1'9930S24 4RWCU(3) -1A REDUCER TO PIPE RMCU-301 VOL 19930524 6RWCU(3) -35 TEE TO PIPE RWCU-301 VOL 19930524 4RWCU (3) -2A REDUCER TO PIPE RWCU-301 VOL 19930524 4RWCU (3) -3A P 1 PE TO ELL RWCU-301 VOL 1'9930524 4RWCU(3) -4A ELL TO PIPE RWCU-301 VOL 19930524 4RWCU(3) -5A PIPE TO PIPE RWCU-301 VOL 1'9930524 COUNT 14 B-A AA BTN HD-SC51 WD RPV-101 VOL 19930516 AB Ni-52 SC CRC WD RPV-101 VOL 19930516 AC 02-%3 SC CRC WD RPV-101 VOL 1'9930522 BA Ol SC VRT WDR45 RPV-101 VOL 19930519 BB 51 SC VRT WR135 RPV-101 VOL 19930518 BC kkl SC VRT WR225 RPV-101 VOL 19'930S1 9 BD 41 SC VRT WR315 RPV-101 VOL 19930518 BE C2 SC VRT W8 10 RPV-101 VOL 1'9'930520 BF 42 SC VRT W8100 RPV-101 VOL 19930513 BG 02 SC VRT W8190 RPV-101 VOL 19930516 BH N2 SC VRT WR280 RPV-101 VOL 19930513 BJ N3 SC VRT WR 50 RPV-101 VOL 1'9930520 Bk( 43 SC VRT W8170 RPV-101 VOL 19930521 Bl'I N3 SC VRT WP290 RPV-101 VOL 19930520

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPT ION ISI DRAWING METHOD EXAM DATE NOTES B-A BN 84 SC VRT WR330 RPV-101 VOL 19'930524 (1) BP I4 SC VRT WR 90 RPV-101 VOL 19930524 (1) BR 54 SC VRT W8210 RPV-101 VOL 19930522 (1) MRP-1 REPAIR AREA RPV-101 VOL 19930521 DA BOT HD MRD 8272 RPV-102 VOL 19930518 (1) r(5) DB BOT HD MRD 8332 RPV-102 VOI 19930518 (1) r(5) DC BOT HD MRD 8 32 RPV-102 VOL 19930518 (1) r(5) DD BOT HD MRD 8 92 RPV-102 VOL 19930518 (1) r (5) DE BOT HD MRD 8152 RPV-102 VOL 1'9930518 (1) r(5) DF BOT HD MRD 8212 RPV-102 VOL 1'9930518 (1) r(5) AJ BOT HD DOL WELD RPV-102 VOL 19930521 DG BOT HD DOL /270 RPV-102 VOL 19930521 (1) r (5) DR BOT HD DOL / '90 RPV-102 VOL 1 9'93052 1 (1) r(5) COUNT B-D N4-30-IR FW NZ-IR 8 30 RPV-101 VOL 19930519 (2) N4-30-NB FW NZ BORE P. 30 RPV-101 VOL 19'93051'9 (2) COUNT 12RHR(1) A-14 VALVE TO SE RHR-105 VOL 19930520 12RHR (1) A-14 VALVE TO SE RHR-105 SUR 19930515 12RFW(1) AC-12 SE/STUB TO SE RFW-101 VOL 19930520 12RFW (1) AC-13 SE TO N4 RFW-101 VOL 19930520 4RRC (4) B-12 SE TO VALVE RRC-109 VOL 19930520 4RRC (4) B-12 SE TO VALVE RRC-109 SUR 19930515 COUNT B-G-1 RPV STUD 35-1-7A RPV STUD RPV-101 VOL 19930526

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO ~ DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES B-G-1 RPV STUD 35-1-7A RPV STUD RPV-101 SUR 19930526 RPV STUD 35-1-14* RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-14A RPV STUD RPV-101 SUR 19'930526 RPV STUD 35-1-21* RPV STUD RPV-101 VOL 1'9930526 RPV STUD 35-. 1-21A RPV STUD RPY-101 SUR 1'9930526 RPV STUD 35-1-28A RPV STUD RPY-101 VOL 19'930526 RPV STUD 35-1-28A RPY STUD RPV-101 SUR 1'9'930526 RPV STUD 35-1-35A RPV STUD RPV-101 VOL 1'9930526 RPV STUD 35-1-35A RPV STUD RPV-101 SUR 19930526 RPV STUD 35-1-42A RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-42A RPV STUD RPV-101 SUR 19930526 RPV STUD 35-1-4'9A RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-49A RPV STUD RPV-101 SUR 19930526 RPV STUD 35-1-56A RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-56A RPV STUD RPV-101 SUR 19930526 RPV STUD 35-1-63A RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-63A RPV STUD RPV-101 SUR 1'9930526 RPV STUD 35-1-70A RPV STUD RPV-101 VOL 19930526 RPV STUD 35-1-70A RPV STUD RPV-101 SUR 19930526 RPV NUT 36-1-7A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-7A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-14A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-14A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-21A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-21A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-28A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-28A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-35A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-35A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-42A RPV .,NUT RPV-101 VOL 1'9930527 RPV NUT 36-1-42A RPV NUT RPV-101 SUR 1'9930527

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY I DENT IF I CAT ION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES B-G-1 RPV NUT 36-1-49A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-49A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-56A RPV NUT RPV-101 VOL 19930527 RPV NUT 36-1-56A RPV NUT RPV-101 SUR 19930S27 RPV NUT 36-1-63A RPV NUT RPV-101 VOL 1'9930527 RPV NUT 36-1-63A RPV NUT RPV-101 SUR 19930527 RPV NUT 36-1-70A RPV NUT RPV-101 ~ VOL 19930527 RPV NUT 36-1-70A RPV NUT RPV-101 SUR 19930527 RPV WASHERS RPV WASHER-76EA RPV-101 VT-1 19930527 (3) COUNT 41 B-G-2 RC I C-V-13-BLT VALVE BOLTING RCIC-102 VT-1 19930514 RCIC-V-65-BLT VALVE BOLTING RCIC-102 VT-1 19930514 6RCIC(1)-28BD FLANGE BOLTING RCIC-102 VT-1 19930526 6RCIC(1)-31BU FLANGE BOLTING RCIC-102 VT-1 1'9930504 bRCIC(1)-41ABD FLANGE BOLTING RCI C-102 VT-1 19'930607 6RCIC(1)-44BD FLANGE BOLTING RCIC-102 VT-1 19930607 RHR-V-41A-BLT VALVE BOLTING RHR-101 VT-1 I 9'9305 1 7 RHR-V-42C-BLT VALVE BOLTING RHR-103 VT-1 19930514 RHR-V-41C-BLT VALVE BOLTING RHR-103 VT-1 19930517 RHR-V-111C-BLT VALVE BOLTING RHR-103 VT-1 19930517 RHR-V-112A-BLT VALVE BOLTING RHR-105 VT-1 19930517 RHR-V-1 12B-BLT VALVE BOLTING RHR-106 VT-1 19930512 MS-V-22A-BLT VALVE BOLTING MS-101 VT-1 1'9930521 MS-V-28A-BLT VALVE BOLTING MS-101 VT-1 1'9'930S04 4MS(12)-1BD FLANGE BOLTING MS-106 VT-1 19930607 4RRC(8)2A-2BD FLANGE BOLTING RRC-101 VT-1 19930506 4RRC(8)1A-2BD FLANGE BOLTING RRC-101 VT-1 19930506 RRC-V-67A-BLT VALVE BOLTING RRC-101 VT-1 19930506 4RWCU(3)-4BD FLANGE BOLTING RWCU-101 VT-1 1'9930526

TABLE I EXANI NATIONS CONPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES B-G-2 RWCU-V-100-BLT VALVE BOLTING RWCU-101 VT-1 19930526 4RWCU(3)-10BD FLANGE BOLTING RWCU-101 VT-1 19930526 RWCU-V-4-BLT VALVE BOLTING RWCU-101 VT-1 19930524 COUNT CG SKIRT KNUCKLE RPV-101 SUR 19930521 COUNT 6SPARE-1 SPARE NZ-FLANGE RPV-102 VOL 19930511 4RCIC(13) 12 PIPE TO PIPE RCIC-101 VOL 1993052'9 4RCIC(13)-13 PIPE TO PEN RCIC-101 VOL 19930528 4RCIC (13) -14 PEN TO ELL RCIC-101 VOL 1'9930527 4RCI C (13) -14 PEN TO RCIC-101 SUR 19930527 4RCIC(13)-15 ELL'LL TO PIPE RCIC-101 VOL 19930527 4RCIC(13)-15 ELL TO PIPE RCI C-101 SUR 1'9930527 4RCIC (13) -16 PIPE TO ELL RCIC-101 VOL 19930527 4RCI C (13) -16 PIPE TO ELL RCIC-101 SUR 19930527 4RCI C (13) -17 ELL TO PIPE RCIC-101 VOL 1'9930527 4RCIC (13) 17 ELL TO PIPE RCIC-101 SUR 19930527 4RCIC (13) 18 PIPE TO PIPE RCIC-101 VOL 19930527 4RCIC (13) 19 PIPE TO VLV RCIC-101 VOL 19930527 4RCIC (13) -19 PIPE TO VLV RCIC-101 SUR 19930527 6RC I C ( 1 ) -1'3 VLV TO PIPE RCIC-102 VOL 19930527 6RCIC(1) 13 VLV TO PIPE RCI C-102 SUR 19930527 6RCIC(1)-14 PI PE TO ELL RCIC-102 VOL 19930527 6RCIC(1)-14 PIPE TO ELL RCIC-102 SUR 19930527 6RCIC (1) -45 FLG TO NOZZLE RCIC-102 VOL 19930511 (4) 14LPCI (1) B-4 PIPE TO ELL RHR-102 VOL 19930513 14LPCI (1) B-4 PIPE TO ELL RHR-102 SUR 19930512

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES B-J 14LPCI (1) B-5 ELL TO PEN RHR-102 VOL 1 '99305 1 3 14LPCI(1)B-5 ELL -TO PEN RHR-102 SUR 19'930512 14LPCI(1)C-1 VLV TO PIPE RHR-103 VOL 19930512 14LPCI (1) C-1 VLV TO PIPE RHR-103 SUR 1'9930512 14LPCI (1) C-8 ELL TO PEN RHR-103 VOL 19930508 14LPC I ( 1 ) C-8 ELL TO PEN RHR-103 SUR 19930508 20RHR(2)-5 ELL TO PIPE RHR-104 VOL 1 9'930529 20RHR (2) -5 ELL TO PIPE RHR-104 SUR 1'9930529 12RHR(1) A-10 ELL TO PIPE RHR-105 VOL 19930517 12RHR (1) A-10 ELL TO PIPE RHR-105 SUR 19930517 12RHR (1) A-13 P IPE TO VALVE RHR-105 VOL 19930517 12RHR(i) A-13 PIPE TO VALVE RHR-105 SUR 19930517 12RHR (1) B-l VLV TO PEN RHR-106 VOL 19930516 12RHR(1)B-1 VLV TO PEN RHR-106 SUR 19930516 12RHR (1) B-7 PIPE TO ELL RHR-106 VOL 1'9930513 12RHR (1) B-7 PIPE TO ELL RHR-106 SUR 1 9'9305 1 3 12RHR (1) B-9 PIPE TO VLV RHR-106 VOL 19930513 12RHR (1) B-9 PIPE TO VLV RHR-106 SUR 19930513 12RHR'( 1 ) B-12LUO ELL SEAN RHR-106 VOL 1 9'9305 1 4 12RHR(1) B-12LUO ELL SEAN RHR-106 SUR 19930512 12RHR (1) B-12 ELL TO PIPE RHR-106 SUR 19'930512 12RHR(1)B-13 P IPE TO VLV RHR-106 VOL 19930514 12RHR (1) B-13 PIPE TO VLV RHR-106 SUR 19930512 26NS ( 1 ) A-7/8NSR-4A PIPE TO SWL NS-101 VOL 19930521 26NS(1)A-7/8MSR-4A PIPE TO SWL NS-101 SUR 1'9930521 26NS(1)A-7/8NSR-3A PIPE TO SWL NS-101 VOL 1'9930521 26NS (1) A-7/8NSR-3A PIPE TO SWL NS-101 SUR 1'9930521 26NS (1) D-7/8MSR-4D PIPE TO SWL MS-104 VOL 19930522 26NS (1) D-7/8NSR-4D PIPE TO SWL NS-104 SUR 19930522 26NS(1)D-7/8NSR-3D PIPE TO SWL NS-104 VOL 19930522 26NS(1)D-7/8NSR-3D PIPE TO SWL MS-104 SUR 19'930522

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION- NO. DESCRIPTION I BI DRAWING NET80D EXAN DATE NOTES B-J 26NS(1)D-7/8NSR-2D PIPE TO SWL NS-104 VOL 19930522 26NS(1)D-7/8MSR-ZD P IPE TO SWL NS-104 SUR 19930522 26NS (1) D-7/8NSR-1D P IPE TO SWL I'IS-104 VOL 19930522 26NS (1) D-7/8NSR-1D PIPE TO SWL NS-104 SUR 19930522 26NS (1) D-8 PIPE TO ELL NS-104 VOL 19930525 26NS ( 1 ) D-8 PIPE TO ELL NS-104 SUR 19'930525 26NS (1) D-8LDI ELL SEAN NS-104 VOL 19930525 26MS (1) D-8LDI ELL SEAN NS-104 SUR 19'930525 Z6NS (1) D-8LDO ELL SEAN I'IS-1 04 VOL 19930525 26NS ( 1 ) D-8LDO FLL SEAN MS-104 SUR 19930525 26NS (1) D-9LUI ELL SEAN NS-104 VOL 1'9'930527 26MS(1) D-9LUI ELL SEAN I'IS-104 SUR 19930527 26NS (1) D-'9LUO ELL SEAN NS-104 VOL 19'930527 26NS(1)D=9LUO ELL BEAN NS-104 SUR 1 9'930527 26MS(1)D-9 ELL TO PIPE NS-104 VOL 19'930527 26NS(1)D-9 ELL TO PIPE NS-104 SUR 19930527 26MB<1)D-16 VALVE TO PENE NS-104 VOL 19930522 26NS(1)D-16 VALVE TO PENE NS-104 SUR 19'930522 26NS(1)D-17 PENE TO PIPE NS-104 VOL 1 '9'9305 1 2 NS-V-28D/2NS(9)-4 DRAIN. CONN NS-104 SUR 19930513 4NS(12)-2 FLANGE/REDUCER NS-106 VOL 19930511 (4) 24RFW (1) A-1 VALVE TO PIPE RFW-101 VOL 19930508 (4) 24RFW (1) A-1/5RFW (11) -4 P IPE TO WOL RFW-101 VOL 1 '99305 1 0 (4) 5RFW (11) A-2 SLEEVE TO WOL RFW-101 VOL 19930510 5RFW(11)A-2 SLEEVE TO WOL RFW-101 SUR 1'9'930507 24RFW(l) A-2 PIPE TO VALVE RFW-101 VOL 19930508 (4) 24RFW(1)A-3 VALVE TO PENE RFW-101 VOL 19930508 (4) 24RFW (1) A-5 VALVE TO PIPE RFW-101 VOL 1'9930522 (4) 24RFW< 1) A-6 PIPE TO ELL RFW-101 VOL 19930522 (4) 24RFW (1) A-7 ELL TO P IPE RFW-101 VOL 19930517 (4) 24RFW ( 1 ) A-8 PIPE TO VALVE RFW-101 VOL 19930517

TABLE I EXAMINATIONS CONPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING I'JETMOD EXAJ'1 DATE NOTES B-J 24RFW (1) A-8 PIPE TO VALVE RFH-101 SUR 19930517 24RFH (1) A-15 P IPE TO TEE RFH-101 VOL 19930519 24RFW (1) A-17 PIPE TO REDUCER RFH-101 VOL 19930520 24RFW (1) A-17 PIPE TO REDUCER RFH-101 SUR 19930520 18RFW < 1) A-1 REDUCER TO PIPE RFW-101 VOL 19930520 18RFH(1)A-1 REDUCER TO PIPE RFH-101 SUR 1'9930520 18RFH(1) A-2 PIPE TO TEE RFW-101 VOL 1'9930522 18RFW(l) A-2 PIPE TO TEE RFW-101 SUR 19930522 18RFH (1) A-4 PIPE TO REDUCER RFM-101 VOL 1'9'930520 18RFM(1)A-4 PIPE TO REDUCER RFH-101 SUR 19930520 24RFM(1)B-1 VALVE TO PIPE RFH-102 VOL 1'9930511 (4) 24RFW(1) B-l/5RFM(11) -4 PIPE TO WOL RFH-102 VOL 19930511 (4) 5RFH(11) B-2 SLEEVE TO WOL RFW-102 VOL 19930512 <4) 24RFW (1) B-2 PIPE TO VALVE RFW-102 VOL 19930511 (4) 24RFIJ(l) B-3 VALVE TO PENE RFM-102 VOL 19930511 (4) 24RFM(1) B-8 PIPE TO VALVE RFW-102 VOL 1'9930517 12RFW (1) BF-2 PIPE TO ELL RFW-102 VOL 1'9930524 12RFW (1) BF-2 PIPE TO ELL RFW-102 SUR 1'9930524 12RFW (1) BF-7 PIPE TO ELL RFM-102 VOL 19930522 12RFW (1) BF-7 PIPE TO ELL RFH-102 SUR 1 9'930'5 22 12RFW (1) BF-8 ELL TO PIPE RFH-102 VOL 19930522 12RFW(1) BF-8 ELL TO PIPE RFW-102 SUR 1'9930522 24RFW (1) B-17 PIPE TO REDUCER RFW-102 VOL 1993051'9 24RFW(1)B-17 PIPE TO REDUCER RFW-102 SUR 1'9930519 18RFW(l)B-1 REDUCER TO PIPE RFW-102 VOL 1993051'9 18RFW(1)B-1 REDUCER TO PIPE RFlJ-102 SUR 1 '99305 1 9 18RFW(1)B-4 PIPE TO REDUCER RFW-102 VOL 19930519 18RFH(l) B-4 PIPE TO REDUCER RFM-102 SUR 19930519 24RRC (1) A-20/12RRC (7) -4S PIPE TO SHL RRC-101 VOL 19930518 24RRC (1) A-20/12RRC (7) -4S PIPE TO SWL RRC-iol SUR 19930506 24RRC <2) B-8/4RRC (8) -4S PIPE TO SWL RRC-102 VOL 19930512

TABLE I EXANI NATIONS CONPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION IS I DRAWING i)ETHOD EXAH DATE NOTES 8-J 24RRC ( 2) 8-S/4RRC (8) -4S PIPE TO SWL RRC-102 SUR 1'9930511 4RRC(8)28-1 SWL TO PIPE RRC-102 VOL 19930512 4RRC (8) 28-1 SWL TO PIPE RRC-102 SUR 19930511 4RRC(S)28-2 PIPE TO FLANGE RRC-102 VOL 19'930512 4RRC(8)28-2 PIPE TO FLANGE RRC-102 SUR 1 9'93051 1 24RRC(2)B-S/4RRC(4)-4S PIPE TO SWL RRC-102 VOL 19930512 24RRC(2)8-S/4RRC(4)-4S PIPE TO SWL RRC-102 SUR 1'9930511 24RRC(2)8-9 PIPE TO ELL RRC-102 VOL 1 '99305 1 3 24RRC(2)8-9LDO ELL SEAN RRC-102 VOL 1 '993051 1 24RRC(2)8-9LDI ELL SEAN RRC-102 VOL 1 '99305 1 1 24RRC(2)8-10LUO ELL SEAN RRC-102 VOL 19'930511 24RRC(2)8-10LUI ELL SEAN RRC-102 VOL 19930511 24RRC(2)B-10 ELL TO PUMP RRC-102 VOL 19930518 24RRC (1) B-l 1 PUNP TO PIPE RRC-102 VOL 19930519

             '24RRC ( 1 ) 8-1 1LD           PIPE SEAM           RRC-102      VOL     19930517 4RRC (8) 18-1                        TO PIPE       RRC-102      VOL     19930517
                                                        'WL 4RRC(8)18-1                    SWL TO PIPE         RRC-102      SUR     19930514 4RRC(8)18-2                    PIPE   TO FLANGE    RRC-102      VOL     19930514 4RRC(8)18-2                    PIPE   TO FLANGE    RRC-102      SUR     19930506 24RRC(1)8-18/12RRC(7)-4S       P IPE  TO SWL       RRC-102      VOL     19'930511 24RRC(1)B-18/12RRC(7)-4S       P IPE  TO SWL       RRC-102      SUR     19930506 lbRRC(1)B-1                    CROSS TO PIPE       RRC-102      VOL     19930522 16RRC(i)B-1/12RRC(1)-N2G       PIPE TO SWL         PRC-102      VOL     19930521 16RRC(1)B-1/12RRC(1)-N2G       PIPE TO SWL         RRC-102      SUR     19930513 16RRC(1)B-1/12RRC(1.)    .N2F PIPE TO SWL         RRC-102      VOL     19930521 lbRRC (1) B-l/12RRC (1) -N2F   PIPE TO SWL         RRC-102      SUR     19930514 16RRC (1) 8-3/12RRC (1) -N2J   PIPE TO SWL         RRC-102      VOL     19930521 16RRC (1) 8-3/12RRC (1) -N2J   PIPE TO SWL         RRC-102      SUR     19930513 16RRC(1)B-3/12RRC(1)-N2K       PIPE TO SWL         RRC-102      VOL     1'9930521 16RRC (1) 8-3/12RRC (1) -N2K   PIPE TO SWL         RRC-102      SUR     19930514 12RRC (1) -N2H-1               REDUCER TO PIPE     RRC-102      VOL     19'930520

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF'93A CODE CATEGORY I DENTI F ICATION NO. DESCRIPTION I SI DRAWING METHOD EXAM DATE 12RRC (1) -N2H-iLD PIPE SEAM RRC-102 VOL 19'930519 20RRC (6) -8 PIPE TO VALVE RRC-105 VOL 19930513 12RRC (7) 8-2LD I ELL SEAM RRC-107 VOL 19'9'30514 12RRC (7) 8-2LDI ELL SEAM RRC-107 SUR 19930512 12RRC(7)8-2LDO ELL SEAM RRC-107 VOL 19930514 12RRC(7)8-2LDO ELL SEAM RRC-107 SUR 19930512 12RRC(7)8-3LUI ELL SEAM RRC-107 VOL 19930514 12RRC(7)B-3LUI ELL SEAM RRC-107 SUR 1 '9'9305 1 2 12RRC(7)8-3LUO ELL SEAM RRC-107 VOL 19'930514 12RRC(7)8-3LUO ELL SEAM RRC-107 SUR 1'9930512 12RRC(7)8-3 ELL TO PIPE RRC-107 VOL 19930517 12RRC(7)8-3 ELL TO PIPE RRC-107 SUR 19930512 12RRC(7)8-3LD PIPE SEAM RRC-107 VOL 19930514 12RRC(7)B-3LD PIPE SEAM RRC-107 SUR 19930512 4RRC(4)8-4 PIPE TO TEE RRC-109 VOL 19930520 4RRC(4)8-5 TEE TO PIPE RRC-109 VOL 19'930520 4RRC(4)8-10 ELL TO PIPE RRC-10'9 VOL 1'9930519 4RRC(4)8-10 ELL TO PIPE RRC-10'9 SUR 1'9930515 6RWCU(3)-20 PIPE TO VALVE RWCU-101 VOL 19930528 6RWCU(3)-21 VALVE TO PIPE RWCU-101 VOL 19930527 6RWCU(3)-22 PIPE TO PENE RWCU-101 VOL 19930527 6RWCU(3)-23 PEN TO ELL RWCU-101 VOL 19'930524 bRWCU(3)-24 ELL TO PIPE RWCU-101 VOL 19930524 bRWCU(3)-25 P I PE TO ELL RWCU-101 VOL 19930524 6RWCU(3)-26 ELL TO PIPE RWCU-101 VOL 1 9'930524 COUNT 170 RCIC-iC-2 (W) 8 WELDED LUGS RCIC-ioi SUR 19930527 RHR-231(W) 4 WELDED LUGS RHR-1 0 1 SUR 19930603 RHR-483(W) WELDED LUGS RHR-102 SUR 19930512

TABL'E I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION IS I DRAWING METHOD EXAM DATE NOTES 8-K-1 MS FLUED HEAD B FLUED HEAD tlELD NS-102 SUR 19930512 NS-HD-2(M) WELDED LUGS MS-104 SUR 19930522 NS FLUED HEAD D FLUED HEAD WELD NS-104 SUR 199'30512 RFW-186 (M) 6 WELDED LUGS RFW-101 SUR 1'9930518 RFM-159(M) 4 WELDED LUGS RFW-101 SUR 1'9930528 RFW-162 (M) 6 WELDED LUGS RFW-102 SUR 19930517 RFW-183 (W) 4 WELDED LUGS RFW-102 SUR 19930528 RRC-SA-2(W) 4 WELDED LUGS RRC-101 SUR 19930506 RRC-SA-1(W) 4 WELDED LUGS RRC-101 SUR 1'9930508 RRC-SB-16(W) 8 WELDED LUGS RRC-102 SUR 19'930515 COUNT 13 B-P RPV-PB-101 (L) LK PRES BNDRY RPV-101 VT-2 19'930620 RPV-PB-102(L) LK PRES BNDRY RPV-102 VT-2 1'9930620 RCIC-PB-101(L) LK PRES BNDRY RCIC-101 VT-2 19930620 RCIC-PB-102(L) LK PRES BNDRY RCIC-102 VT-2 19'930620 HPCS-PB-101 (L) LK PRES BNDRY HPCS-101 VT-2 19930620 LPCS-PB-101 (L) LK PRES BNDRY LPCS-101 VT-2 19930620 RHR-PB-101 (L) LK PRES BNDRY RHR-101 VT-2 1'9930620 RHR-PB-102(L) LK PRES BNDRY RHR-102 VT-2 19930620 RHR-PB-103 (L) LK PRES BNDRY RHR-103 VT-2 19930620 RHR-PB-104(L) LK PRES BNDRY RHR-104 VT-2 19930620 RHR-PB-105 (L) LK PRES BNDRY RHR-105 VT-2 19930620 RHR-PB-106 (L) LK PRES BNDRY RHR-106 VT-2 19'930620 NS-PB-101 (L) LK PRES BNDRY NS-101 VT-2 19930620 NS-PB-102(L) LK PRES BNDRY HS-102 VT-2 1'9930620 NS-PB-103 (L) LK PRES BNDRY NS-103 VT-2 19930620 HS-PB-104 (L) LK PRES BNDRY NS-104 VT-2 19'930620 NS-PB-105 (L) LK PRES BNDRY NS-105 VT-2 19930620 NS-PB-106(L) LK PRES BNDRY NS-106 VT-2 1'9930620

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY I DENT IF ICATION NO. DESCR I PT I ON ISI DRAWING t'1ETHOD EXAM DATE NOTES 8-P RFW-PB-101(L) LK PRES BNDRY RFW-101 VT-2 19930620 RFW-PB-102 (L) LK PRES BNDRY RFM-102 VT-2 1'9930620 RFM-PB-103(L) LK PRES BNDRY RFW-103 VT-2 19930620 RRC-PB-101(L) LK PRES BNDRY RRC-101 VT-2 19'930620 RRC-PB-102(L) LK PRES BNDRY RRC-102 VT-2 19930620 RRC-PB-103(L) LK PRES BNDRY RRC-103 VT-2 19930620 RRC-PB-104(L) LK PRES BNDRY RRC-104 VT-2 19930620 RRC-PB-105(L) LK PRES BNDRY RRC-105 VT-2 19930620 RRC-PB-106(L) LK PRES BNDRY RRC-106 VT-2 19930620 RRC-PB-107 (L) LK PRES BNDRY RRC-107 VT-2 19'930620 RRC-PB-108(L) LK PRES BNDRY RRC-108 VT-2 19930620 RRC-PB-109 (L) LK PRES BNDRY RRC-109 VT-2 19930620 RRC-PB-110 (L) LK PRES BNDRY RRC-110 VT-2 1'9'930620 RRC-PB-111(L) LK PRES BNDRY RRC-111 VT-2 1'9930620 RWCU-PB-101(L) LK PRES BNDRY RWCU-101 VT-2 19930620 SLC-PB-101 (L) LK PRESS BNDRY SLC-101 VT-2 19'930620 COUNT C-C RHR-188 W)< 4 WELDED LUGS RHR-201 SUR 19930604 RHR-419(W) WELDED LUGS RHR-203 SUR 19930521 RHR-420(W) WELDED LUGS RHR-203 SUR 19930521 RHR-76(W) WELDED LUGS RHR-205 SUR 19930524 RHR-'917N(W) 4 WELDED LUGS RHR-205 SUR 1'9930531 RHR-'918N(W) 8 WELDED LUGS RHR-207 SUR 1993052 ) RHR-924N(W) 4 WELDED LUGS RHR-207 SUR 1'9930604 RHR-495(M) 8 WELDED LUGS RHR-207 SUR 19930528 RHR-185<W) 4 MELDED LUGS RHR-207 SUR 19930528 RHR-218 (W) 8 WELDED LUGS RHR-207 SUR 19930521 RHR-184 (W) 16 WELDED LUGS RHR-207 SUR 1'9930521 NS-71(W) 2 WELDED LUGS NS-204 SUR 19930531 COUNT 12

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES C-F-2 6RCIC (6) 1 TEE TO PIPE RCIC-205 VOL 19930505 10HPCS (9 )-1 TEE TO PIPE HPCS-202 VOL 19'930506 (4) 18RHR (1) A-4 PIPE TO ELL RHR-201 VOL 19930531 18RHR(1) A-4 PIPE TO ELL RHR-201 SUR 19930531 18RHR(1) A-5 ELL TO PIPE RHR-201 VOL 19930531 18RHR(1) A-5 ELL TO PIPE RHR-201 SUR 19930531 18RHR(1) A-6 PIPE TO ELL RHR-201 VOL 19'930531 18RHR(l) A-6 PIPE TO ELL RHR-201 SUR 19930531 18RHR(i) A-21 PIPE TO TEE RHR-201 VOL 19'930603 18RHR(1) A-21 PIPE TO TEE RHR-201 SUR 19930603 18RHR(2) A-12 PIPE TO TEE RHR-205 VOL 19930531 18RHR(2) A-12 PIPE TO TEE RHR-205 SUR 19930531 24RHR(2) A-2 TEE TO PIPE RHR-205 VOL 19930531 24RHR(2) A-2 TEE TO PIPE RHR-205 SUR 19930531 24RHR(2) A-6 FLANGE TO ELL RHR-205 VOL 1'9930531 24RHR(2) A-6 FLANGE TO ELL RHR-205 SUR 19930531 24RHR(3) A-10 ELL TO TEE RHR-205 VOL 19930531 24RHR(3) A-10 ELL TO TEE RHR-205 SUR 19930531 20RHR(8) A-lB FLANGE TO PIPE RHR-206 VOL 19930603 20RHR(8) A-1B FLANGE TO PIPE RHR-206 SUR 19'930603 20RHR(8) A-4 PIPE TO PIPE RHR-206 VOL 199306Q1 20RHR(8) A-4 PIPE TO PIPE RHR-206 SUR 1'9930601 20RHR(8) A-17 ELL TO PIPE RHR-206 VOL 1'9930603 20RHR(8) A-17 ELL TO PIPE RHR-206 SUR 19930603 14RHR(1) C-1 RED TO PIPE RHR-210 VOL 19'930506 14RHR(1) C-1 RED TO PIPE RHR-210 SUR 19930506 14RHR(1) C-6 PIPE TO PIPE RHR-210 VOL 19930506 14RHR(1) C-6 PIPE TO PIPE RHR-210 SUR 19930506 24RHR(3) -2 VALVE TO PIPE RHR-211 VOL 1993Q602 24RHR(3) -2 VALVE TO PIPE RHR-211 SUR 19930602 24RHR(3) -2/3(17)-1 BRANCH CONN RHR-211 SUR 1'9'930602

TABLE I EXAMINATIONS CONPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION IS I DRAWING METHOD EXAM DATE NOTES C-F-2 24RHR(3)-6 ELL TO PIPE RHR-211 VOL 19930602 ZORHR(3)-6 ELL TO PIPE RHR-Zli SUR 19930602 ZRRHR(3)-8 ELL TO PIPE RHR-211 VOL 19930602 24RHR(3)-8 ELL TO PIPE RHR-211 SUR 19'930602 26MS (1) A-19/3V-20 DRAIN CONN NS-201 SUR 1'9930511 30NS(1)A-7LU PIPE LONG SEAN NS-201 VOL 19930603 30NS (1) A-7LU PIPE LONG SEAN NS-201 SUR 19930603 30NS (1) A-7 PIPE TO ELL NS-201 VOL 19'930529 30NS ( 1 ) A-7 PIPE TO ELL NS-201 SUR 19930529 30NS (1) A-7LDI ELL SEAM MS-201 VOL 19930529 30NS (1) A-7LDI ELL SEAN NS-201 SUR 19930529 30NS (1) A-7LDO ELL SEAM NS-201 VOL 19930529 30MS (1) A-7LDO ELL SEAN NS-201 SUR 1993052'9 30NS(1) A-lbLUO ELL SEAN NS-201 VOL 19930529 30NS (1) A-16LUO ELL SEAM NS-201 SUR 19930529 30NS (1) A-16 ELL TO PIPE NS-201 VOL 1'9930529 30MS(1) A-16 ELL TO PIPE NS-201 SUR 19'930529 30MS(1)A-16LD PIPE LONG SEAM MS-201 VOL 19930603 30NS (1) A-16LD PIPE LONG SEAM MS-201 SUR 19'930603 18NS(1) A-3 ELL TO PIPE NS-201 VOL 19930528 18NS ( 1 ) A-3 ELL TO PIPE NS-201 SUR 1993052'9 18NS (1) A-8 PIPE TO ELL NS-201 VOL 1 '9'93053 1 18NS(1) A-8 PIPE TO ELL MS-201 SUR 19930531 18NS ( 1') A-9 ELL TO PIPE NS-201 VOL 1'9930531 18NS (1) A-9 ELL TO PIPE MS-201 SUR 1'9930531 26NS (1) B-20LU PIPE LONG SEAN MS-202 VOL 1'9'930512 26NS(l)B-20LU PIPE LONG SEAN NS-202 SUR 19930511 26NS(l)B-20 PIPE TO PIPE NS-202 VOL 19930508 26NS (1) B-20 PIPE TO PIPE NS-202 SUR 19'930507 26NS ( 1 ) B-20LD PIPE LONG SEAM MS-202 VOL 19930512 26NS(l)B-20LD PIPE LONG SEAN NS-202 SUR 1'9930511

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION I SI DRAWING METHOD EXAM DATE C-F-2 26MS(i)B-20/3V-20 DRAIN CONN MS-202 SUR 19930513 26MS(1)C-20/3V-20 DRAIN CONN MS-203 SUR 19930513 24MS (1) -2 PIPE TO VALVE MS-205 VOL 19930513 24MB (1) -2 PIPE TO VALVE MS-205 SUR 1'9930513 SCRD (12) A-18/2FLG PIPET TO EL CRD-201 SUR 19930518 8CRD ( 1 2) A-22! 2FLG P I PET TO EL CRD-201 SUR 19930519 SCRD (12) B-18/2FLG P I PET TO EL CRD-202 SUR 1'9930520 SCRD (12) B-22/2FLG P I PET TO EL CRD-202 SUR 19930520 COUNT 70 D-A RCC-PB-303(H) HYDRO TEST BNDY RCC-303 VT-~ 19930301 RCC-PB-304(H) HYDRO TEST BNDY RCC-304 VT-2 19930301 MSRV-1B-2(M) WELDED ATTACH 1'1S-305 VT-3 19930517 MS-281 (M) WELDED ATTACH MS-305 VT-3 19930515 MS-282 (W) WELDED ATTACH MS-305 VT-3 19930515 COUNT D-B SW-59(M) WELDED ATTACH SW-301 VT-3 1'99'30508 SM-62(W) WELDED ATTACH SW-301 VT-3 1993050S SW-63(M) WELDED ATTACH SW-301 VT-3 1993050S SW-64(M) IJELDED ATTACH SW-301 VT-3 19930508 SW-66(W) WELDED ATTACH SIJ-301 VT-3 19930508 SW-71(W) WELDED ATTACH SM-301 VT-3 19930508 SW-173 (W) WELDED ATTACH SW-301 VT-3 19930508 SW-68 (W) WELDED ATTACH SW-301 VT-3 19930508 SM-70(M) IJELDED ATTACH SM-301 VT-3 1'9930510 SW-73(W) WELDED ATTACH SW-301 VT-3 1 '9'9305 1 0 SW-200(W) WELDED ATTACH SW-301 VT-3 1 '99305 1 0 SW-434(W) WELDED ATTACH SW-301 VT-3 1 '99305 1 0

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DFSCR I PT I OI'l IS I DRAWING NETHOD EXAM DATE NOTES D-B SW-122 (W) WELDED ATTACH SW-301 VT-3 19930513 SM-123(W) WELDED ATTACH SM-301 VT-'3 19'930513 SN-358(M) WELDED ATTACH SM-304 VT-3 19930429 SW-357(W) WELDED ATTACH SW-304 VT-3 19930429 SM-356(W) WELDED ATTACH SW-304 VT-3 19930429 SW-354(W) WELDED ATTACH SW-304 VT-3 19930429 SN-426(W) WELDED ATTACH SW-304 VT-3 1'993042'9 SW-355(M) WELDED ATTACH SN-304 VT-3 19930429 SW-22(W) WELDED ATTACH SW-305 VT-3 19'930513 SW-308(N) WELDED ATTACH SW-306 VT-3 1993042'9 SW-307(W) WELDED ATTACH SW-306 VT-3 19930429 SW-266(W) WELDED ATTACH SM-306 VT-3 19930429 SW-267(W) WELDED ATTACH SW-306 VT-3 19930429 SW-292(W) WELDED ATTACH SM-306 VT-3 1'9'93042'9 SM-293(W) WELDED ATTACH SM-306 VT-3 1993042'9 SM-294(W) WELDED ATTACH SW-306 VT-3 1 9'93042'9 SW-306(W) WELDED ATTACH SM-306 VT-3 1993042'9 SW-302(W) WELDED ATTACH SM-306 VT-3 1993042'9 SW-312 (N) WELDED ATTACH SM-306 VT-3 1993042'9 SM-80(W) WELDED ATTACH SW-307 VT-3 19'930511 SW-81 (M) WELDED ATTACH SW-307 VT-3 19930511 SM-914N (N) WELDED ATTACH SW-307 VT-3 1'993051 1 SN-'917N ( W) WELDED ATTACH SW-307 VT-3 19930511 SW-83(W) WELDED ATTACH SW-307 VT-3 1 '9 930 S 1 3 SW-84(W) WELDED ATTACH SW-307 VT-3 19930511 SW-195 (W) WELDED ATTACH SW-307 VT-3 19930514 SW-943N(W) WELDED ATTACH SW-307 VT-3 19930429 SW-19(W) WELDED ATTACH SW-307 VT-3 19930430 SW-919N(W) WELDED ATTACH SW-307 VT-3 19'930504 SN-921N (W) WELDED ATTACH SW-307 VT-3 19930504 SW-922N(W) WELDED ATTACH SN-307 VT-3 1'9930430

TABLE EXAMINATIONS CONPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING NETHOD EXAth DATE NOTES 0-B SW-923N(W) WELDED ATTACH SW-307 VT-3 19930504 SW-924N(W) WELDED ATTACH SW-307 VT-3 19930504 SW-925N(W) WELDED ATTACH SW-307 VT-3 19930504 SW-926N(W) WELDED ATTACH SW-307 VT-3 19930504 SW-927N(W) WELDED ATTACH SW-307 VT-3 19930504 SW-928N(W) WELDED ATTACH SW-307 VT-3 19930430 SW-929N(W) WELDED ATTACH SW-307 VT-3 19930430 SW-935N(M) WELDED ATTACH SM-307 VT-3 19930430 SW-13 (M) WELDED ATTACH SW-309 VT-3 19930429 StJ-966N (W) WELDED ATTACH SM-312 VT-3 19930514 SW-1022N (M) WELDED ATTACH SW-313 VT-3 19930513 SW-1032N (W) WELDED ATTACH SW-313 VT-3 19930513 SW-954N (W) WELDED ATTACH SW-314 VT-3 19930513 CCH-PB (H) HYDRO PB N/A VT-2 19930528 COUNT D-C FPC-64(W) WELDED ATTACH FPC-301 VT-3 19930514 (1) FPC-PB-301(H) HYDRO PRES BNDR FPC-301 VT-2 19930301 R9SCH FPC-PB-302(H) HYDRO PRES BNDR FPC-302 VT-2 19930301 R9SCH FPC-PB-303(H) HYDRO PRES BNDR FPC-303 VT-2 1 '9'93030 1 R9SCH FPC-PB-304(H) HYDRO PRES BNDR FPC-304 VT-2 19930301 R'9SCH FPC-48(M) WELDED ATTACH FPC-307 VT-3 1'9930514 FPC-50(W) WELDED ATTACH FPC-307 VT-3 19930514 FPC-PB-307(H) HYDRO PRES BNDR FPC-307 VT-2 19930301 R'95CH FPC-PB-309(H) HYDRO PRES BNDR FPC-308 VT-2 1'9930514 FPC-PB-310(H) HYDRO PRES BNDR FPC-308 VT-2 19930514 FPC-PB-311(H) HYDRO PRES BNDR FPC-308 VT-2 19'930514 FPC-PB-324(K) HYDRO PRES BNDR FPC-308 VT-2 19930514 FPC-PB-325(H) HYDRO PRES BNDR FPC-308 VT-2 19'930514 FPC-PB-326(H) HYDRO PRES BNDR FPC-308 VT-2 19930514 COUNT 14

TABLE I EXANINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION IS I DRAWING NETHOD EXAH DATE NOTES IWF RHR-520 SPRING RCIC-102 VT3H 19930514 RHR-979N STRUT RCIC-102 VT3H 1'9930514 RCIC-102 STRUT RCIC-102 VT3H 1'9930514 RCIC-103 STRUT RCIC-102 VT3H 19930514 RCIC-104 SPRING RCIC-102 VT3H 1'9930514 RC I C-942N SPRING RCIC-102 VT3H 19930515 RCIC-939N STRUT RCIC-102 VT3H 19930515 RCIC-56 SPRING RCIC-204 VT3H 19930430 RCIC-47 BOX RCIC-204 VT3H 19930430 RCIC-902N SPRING RCIC-204 VT3H 19930511 RCIC-53 SPRING RCIC-204 VT3H 19'930405 RCI C-'90l N STRUT RCIC-204 VT3H 1 9'930430 HPCS-31 STRUT HPCS-202 VT38 19930505 HPCS-32 SPRING HPCS-202 VT3H 19930505 HPCS-33 BOX/STR UT HPCS-202 VT3H 19'930505 HPCS-34 SPRING HPCS-202 VT3H 19930505 HPCS-921N STRUT HPCS-205 VT3H 19930501 HPCS-12 STRUT HPCS-205 VT3H 19930501 HPCS-922N STRUT HPCS-205 VT3H 1'9930430 LPCS-13 SPRING LPCS-101 VT3H 19930511 RHR-504 SPRING 'NUBBER RHR-105 VT3H 1 '99305 1 2 RHR-SA-40 PSA-10 RHR-105 VT3H 19930512 RHR-SA-39 PSA-10 SN(2) RHR-105 VT3H 19930512 RHR-SA-38 PSA-10 SNUBBER RHR-105 VT3H 1 9'9305 1 2 RHR-506 SPRING RHR-105 VT3H 1'9930512 RHR-SA-36 PSA-35 SNUBBER RHR-105 VT3H 19930512 RHR-SA-35 PSA-10 SNUBBER RHR-105 VT3H 19930512 RHR-159 STRUT RHR-201 VT3H 1'9930430 RHR-161 SPRING RHR-201 VT3H 19930430 RHR-162 STRUT RHR-201 VT3H 19930430 RHR-163 STRUT RHR-201 VT3H 19930430

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF'93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES IWF RHR-164 STRUT RHR-201 VT3H 1'9930430 RHR-165 STRUT RHR-201 VT3H 19'930430 RHR-188 SPRING RHR-201 VT3H 19930430 RHR-'970N ANCHOR RHR-201 VT3H 19930504 RHR-419 PSA-3 SN(2) RHR-203 VT3H 19'930504 RHR-130 BOX RHR-206 VT3H 19930503 RHR-131 STRUT RHR-206 VT3H 19930501 RHR-432 SPRING RHR-206 VT3H 19930501 RHR-132 ANCHOR RHR-206 VT3H 19930503 RHR-916N RIGID RHR-206 VT3H 19930503 RHR-55 BOX ,RHR-206 VT3H 19930503 RHR-493 SPRING RHR-207 VT3H 19930505 RHR-495 PSA-35 SN (2) RHR-207 VT3H 19930510 RHR-4'94 PSA-10 SNUBBER RHR-207 VT3H 19'930505 RHR-496 PSA-10 SNUBBER RHR-207 VT3H 1'9930505 RHR-497 SPRING RHR-207 VT3H 1'9930505 RHR-323 SPRING RHR-210 VT3H 19930501 RHR-1021N PSA-3 SN(2) RHR-210 VT3H 19930501 RHR-322 BOX RHR-210 VT3H 19930501 RHR-321 SPRING RHR-210 VT3H 19930501 RHR-31 1 PSA-3 SN (2) RHR-210 VT3H 19930501 RHR-303 SPRING RHR-210 VT3H 19930501 RHR-302 STRUT RHR-210 VT3H 19930501 RHR-301 PSA-3 SNUBBER RHR-210 VT3H 19930501 RHR-304 STRUT RHR-210 VT3H 19930501 RHR-298 BOX/STRUT RHR-210 VT3H 19930501 RHR-324 STRUT RHR-210 VT3H 1'9'930501 RHR-337 STRUT RHR-210 VT3H 19930501 RHR-338 SPRING RHR-210 VT3H 19930501 RHR-973N ANCHOR RHR-210 VT3H 19930517 RHR-972N BOX RHR-210 VT3H 19930501

TABLE EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE IMF RHR-345 PSA-1 S N(2) RHR-210 VT3H 19930501 RHR-347 BOX RHR-210 VT3H 19'930501 RHR-346 STRUT RHR-210 VT3H 1'9930S01 RHR-348 SPRING RHR-210 VT3H 19930501 RHR-349 SPRING RHR-210 VT3H 19930501 RHR-296 SPRING RHR-210 VT'3H 19'930501 RHR-2'95 BOX RHR-210 VT3H 19930501 RHR-98 STRUT RHR-210 VT3H 1'9'930505 RHR-'97 BOX RHR-210 VT3H 19930505 RHR-96 BOX RHR-210 VT3H 1'9930505 RHR-95 SPRING RHR-210 VT3H 19930505 RHR-94 STRUT RHR-210 VT3H 19930505 RHR-'90 BOX RHR-210 VT3H 1'9930506 RHR-91 STRUT RHR-210 VT3H 1'9930506 RHR-996N ANCHOR RHR-210 VT3H 19930507 RHR-318 RIGID RHR-210 VT3H 1 99'3050 1 RHR-31'9 RIGID RHR-210 VT3H 1'9930501 RHR-'997N ANCHOR RHR-210 VT3H 19930517 RHR-320 SPRING RHR-210 VT3H 19930501 RHR-905N STRUT RHR-211 VT3H 19930501 RHR-900N STRUT RHR-211 VT3H 19'930501 RHR-47 STRUT RHR-211 VT3H 19930501 RHR-46 BOX RHR-211 VT3H 1'9'930501 RHR-966N ANCHOR RHR-211 VT3H 19930501 RHR-41 BOX RHR-211 VT3H 19930501 RHR-13'9 SPRING RHR-211 VT3H 1'9930501 RHR-40 STRUT RHR-211 VT3H 19930501 RHR-39 PSA-3 S N(2) RHR-211 VT3H 19'930501 RHR-35 SPRING RHR-211 VT3H 19930S01 RHR-37 BOX RHR-211 VT3H 19930501 RHR-51 STRUT RHR-211 VT3H 1'9930430

TABLE I EXANI NATIONS CONPLETED DURING OUTAGE RF'93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING NETHOD EXAM DATE NOTES IWF RHR-50 PSA-3 SNB/STRUT RHR-211 VT3H 19930430 RHR-42 PSA-3 SNUBBER RHR-211 VT3H 19930501 RHR-43 SPRING RHR-211 VT3H 1'9'930501 RHR-395 SPRING RHR-212 VT3H 19930430 RHR-3'9l ANCHOR RHR-212 VT3H 19930430 RHR-392 BOX RHR-212 VT3H 19930430 RHR-393 BOX RHR-212 VT3H 19930430 RHR-3'94 SPRING RHR-212 VT3H 19930430 RHR-954N PSA-1 SN (2) RHR-216 VT3H 19930504 RHR-940N PSA-3 SN(2) RHR-224 VT3H 19930504 RHR-959N PSA-3 SN(2) RHR-224 VT3H 1'9930504 RHR-934N SPRING RHR-224 VT3H 19930504 RHR-987N RIGID RHR-232 VT3H 19930504 NS-SA-4 STRUT MS-101 VT3H 19930512 NS-HA-2 SPRING (2) NS-101 VT3H 19'930512 NS-HB-1 SPRING (2) MS-102 VT3H 19930515 NS-SB-7 RIGID STRUT 1'1S-102 VT3H 19930515 NS-SD-4 STRUT NS-104 VT3H 19930513 MS-HD-2 SPR ING (2) NS-104 VT3H 19930513 NS-SD-1 STRUT NS-104 VT3H 19930513 MS-Sn-2 STRUT NS-104 VT3H 19'930513 MS-2619-16 STRUT MS-106 VT3H 19930503 MS-2619-17 SPRING NS-106 VT3H 1'9'930503 NS-2619-21 STRUT 1'1S-1 06 VT3H 19930517 MS-2619-211 SPRING MS-106 VT3H 1 '99305 1 7 NS-2619-22 RIGID MS-106 VT3H 19930517 NS-2619-24 RIGID MS-106 VT3H 19930517 NS-137 SPRING NS-201 VT3H 1'9'930505 NS-123 STRUT MS-201 VT3H 19930518 MS-121 SPRING (2) NS-201 VT3H 19930520 NS-120 SPRING (2) MS-201 VT3H 19930520

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION I S I DRA(l ING METHOD EXAi'1 DATE NOTES IMF MS-119 STRUT MS-201 VT3H 19930520 MS-118 STRUT -MS-201 VT3H 1 9'930520 MS-1 1-5 SPRING MS-201 VT3H 19930520 MS-103 BOX MS-201 VT3H 19930520 MS-101 SPRING (2) MS-201 VT3H 19930520 MS-100 STRUT MS-201 VT3H 19930520 MS-992N BOX MS-201 VT3H 19930520 MS-98 STRUT MS-201 VT3H 19930520 MS-97 SPRING MS-201 VT3H 19930520 MS-139 SPRING MS-201 VT3H 1'9'930520 MS-140 STRUT MS-201 VT3H 19930520 MS-94 BOQ MS-201 VT3H 19930520 MS-95 STRUT MS-201 VT3H 19930520 MS-96 PSA-10 SN (2) MS-201 VT3H 19930520 MS-93 SPRING (2) MS-201 VT3H 19930520 MS-'924N SPRING MS-?01 VT3H 19930520 MS-'91 PSA-3 SN(2) MS-201 VT3H 19930520 MS-174 PSA-35 SNUBBER MS-202 VT3H 19930518 MS-173 SPRING MS-202 VT38 1'9'930520 MS-171 SPRING MS-202 VT38 19930518 MS-997N STRUT MS-202 VT3H 19930518 MS-998N PSA-10 SN (2) MS-202 VT3H 19930518 MS-170 SPRING (2) MS-202 VT3H 19930520 MS-168 STRUT MS-202 VT3H 19930520 MS-167 PSA-10 SN (2) MS-202 VT3H 1'9930S20 MS-996N PSA-10 SN (2) MS-202 VT3H 19930520 MS-163 SPRING (2) MS-202 VT3H 19930520 MS-160 STRUT MS-202 VT3H 19930520 MS-162 PSA-io SN(2) MS-202 VT3H 19930520 MS-157 STRUT MS-202 VT3H 19930520 MS-1S4 RIGID MS-202 VT3H 19'930520

TABLE EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES MS-177 PSA-3 SN(2) MS-202 VT3H 19930520 MS-147 PSA-35 SN(2) MS-202 VT3H 19930520 MS-148 PSA-10 SNUBBER MS-202 VT3H 19'930520 MS-145 PSA-10 SNUBBER I'ls-202 VT3H 19930520 MS-921 N STRUT MS-203 VT3H .19930520 MS-38 PSA-10 SN (2) MS-203 VT3H 19930520 MS-37'S-1001N SPRING (2) l'ls-203 VT3H 19930520 PSA-35 SNUBBER MS-203 VT3H 19'930520 MS-36 STRUT MS-203 VT3H 19930520 MS-1000N STRUT MS-203 VT3H 19930520 MS-34 STRUT MS-203 VT3H 19930520 l'1S-33 SPRING (2) MS-203 VT3H 19930520 MS-999N PSA-10 SNUBBER MS-203 VT3H 1'9930520 MS-48 PSA-3 SNUBBER MS-203 VT3H 19930520 MS-994N BOX MS-203 VT3H 1'9930520 MS-27 PSA-10 SN(2) MS-203 VT3H 19930520 MS-26 STRUT MS-203 VT3H 19930522 MS-63 SPRING (2) MS-204 VT3H 19930520 MS-906N STRUT(2) MS-204 VT3H 1'9930520 MS-62 SPRING (2) MS-204 VT3H 19'930520 MS-61 STRUT MS-204 VT3H 19930520 MS-1009N RIGID MS-204 VT3H 19930520 MS-59 STRUT MS-204 VT3H 19930520 MS-57 STRUT MS-204 VT3H 19930522 MS-53, STRUT l'1S-204 VT3H 19930522 MS-54 STRUT MS-204 VT3H 1'9930522 MS-51 SPRING (2) MS-204 VT3H 19930522 MS-1005N PSA-35 SNUBBER MS-204 VT3H 19930522 MS-50 SPRING MS-204 VT3H 19930522 RFW-164 STRUT RFW-102 VT3H 1'9930513 RRC-SA-65 PSA-35 SNUBBER RRC-101 VT3H 1'9930515

TABLE I EXAMINATIONS COI1PLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO ~ DESCRIPTION IS I DRAWING NETHOD EXAM DATE NOTES IWF RRC-SA-7 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-SA-15 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-SA-8 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-SA-'9 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-SA-17 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-SA-18 PSA-35 SNUBBER RRC-101 VT3H 19930515 RRC-HB-7 SPRING RRC-102 VT3H 19930515 RRC-HB-9 SPRING RRC-102 VT3H 19'930515 RRC-SB-13 PSA-35 SNUBBER RRC-102 VT3H 19930515 RRC-SB-11 PSA-35 SNUBBER RRC-102 VT3H 19930515 RRC-HB-8 SPRING RRC-102 VT3H 19930515 RRC-SB-14 PSA-35 SNUBBER RRC-102 VT3H 19930515 RHR-SA-30 PSA-10 SN(2) RRC-106 VT3H 1'9930515 RHR-SA-31 PSA-10 SNUBBER RRC-106 VT3H 19930515 RRC-9 SPRING RRC-106 VT3H 19930515 RRC-6 SPRING RRC-109 VT3H 19930517 RRC-1C-6PS STRUT RRC-10'9 VT3H 19930517 RRC-4470-31 PSA-1 SNUBBER RRC-111 VT3H 19930517 RWCU-1C-17 PSA-1 SN(2) RWCU-101 VT3H 19930512 RMCU-144 SPRING RWCU-101 VT3H 19930512 RWCU-143 SPRING RWCU-101 VT3H 1 9'9305 1 2 RWCU-146 SPRING RWCU-101 VT3H 1'9930512 RWCU-1C-7PS STRUT RMCU-101 VT3H 19930512 RMCU-145 SPRING RWCU-101 VT3H 19930512 RWCU-1C-7 PSA-3 SNUBBER RWCU-101 VT3H 19930512 RWCU-1C-6 PSA-3 SNUBBER RWCU-101 VT3H 19930513 RWCU-1C-8 PSA-3 SNUBBER RWCU-101 VT3H 1 9'930513 RMCU-1C-5PS STRUT RWCU-101 VT3H 19930513 Rt)CU-1C-5 PSA-3 SNUBBER RWCU-101 VT3H 19930513 RWCU-1C-3PS STRUT RWCU-101 VT3H 19930513 RWCU-1C-1 STRUT RWCU-101 VT3H 19930521

TABLE I EXAMINATIONS COMPLETED DURING OUTAGE RF93A CODE CATEGORY IDENTIFICATION NO. -DESCRIPTION ISI DRAWING METHOD EXAM DATE NOTES IWF RWCU-927N PSA-3 SNUBBER RWCU-301 VT3H 19930524 RWCU-928N PSA-10 SNUBBER RWCU-301 VT3H 19930524 S(l-'938N BOX SW-303 VT3H 1'9930509 SW-936N BOX SW-303 VT3H 1'9930509 SW RI NG HDR B (CS) RING HDR SUPPT SW-303 VT3H 1993050'9 SW-920N BOX SW-307 VT3H 1 9'9305 1 0 FPC-243 BOX FPC-305 VT3H 1 9'930521 FPC-244 BOX FPC-305 VT3H 19930521 FPC-245 BOX FPC-305 VT3H 19930521 FPC-246 BOX FPC-305 VT3H 19930521 FPC-247 BOX FPC-305 VT'3H 19'930521 FPC-24o BOX FPC-305 VT3H 19930521 MS-272. SPRING MS-303 VT3H 19930517 MS-273 SPRING MS-303 VT3H 19930517 MS-274 SPRING MS-303 VT3H 19930515 MS-275 SPRING MS-303 VT3H 19930515 MSRV-3A-7PS RIGID MS-303 VT3H 19930515 MSRV-4B-5 RIGID STRUT MS-308 VT3H 19930515 MSRV-4B-7 RIGID STRUT MS-308 VT3H 19930515 COUNT 236 N/A JET PUMP BEAMS JP HLD DWN BMS RPV-101 VT-1 19930601 (6) JET PUMP BEAMS JP HLD DWN BMS RPV-101 VOL 1'9930526 (6) JET PUMP SENSING LINES JP SENSING LINE RPV-101 VT-1 1'9930601 (7) CORE SPRAY SPARGERS CORE- SPRAY SPG RPV-101 VT-1 19930601 (8) STEAM DRYER STEAM DRYER RPV-101 VT-3 19930601 16LPCS (1) -5 PIPE TO ELL LPCS-202 THK 1'9'930529 ('9) RWCU THRM SLEEVE THERMAL SLEEVE RWCU-301 VOL 19930524 (10) 24CSP (1) -2 ELL TO TEE MISC VOL 19930506 (11) COUNT TOTAL COUNT 732

ISI

SUMMARY

REPORT RF93A Table II Snubber Testing Summary

TABLE II SNUBBER TEST SUMNARY HANGER NARK NO. (O'OSITION) TEST DATE TEST RESULT REPLACEMENT RETEST NEXT DESCRIPTION b SERIAL NO. YR/NO/DA ACC/REJ SERIAL NO. OUTAGE: Y/N DE-2 PSA-3 SNUBBER 3934 19930508 ACC DE-2839-14B PSA-1/4 SNUBBER 19930508 ACC NO FPC-918N PSA-1 SNUBBER 114 19930508 ACC NO LPCS-28 PSA-3 SNUBBER 3891 19'930507 ACC NO ND-1285-14A PSA-1/2 SNUBBER 2473 1 9'9305 1 0 ACC NO ND-1285-14A PSA-1/2 SNUBBER 4011 19930507 ACC 2473 NO NS-1002N NORTH PSA-10 SN(2) 9900 19930507 ACC NO NS-114 SOUTH PSA:10 SN(2) 19'930507 ACC NO NS-177 NORTH PSA-3 SN (2) 1071 19'930507 ACC NO NS-4448-46 PSA-1/4 SNUBBER 19930503 ACC NB-72 PSA-35 SNUBBER 8691 19930506 ACC NO

TABLE II SNUBBER TEST SUNNARY HANGER NARK NO. (5 POSITION) TEST DATE TEST RESULT REPLACENENT RETEST NEXT DESCRIPTION h SER I AL NO. YR/MO/DA ACC/REJ SERIAL NO. OUTAGE: Y/N NS-91 WEST PSA-3 SN(2) 2793 19930507 ACC NO NSLC-2821-22 PSA-1 SNUBBER 581 19930503 ACC NO NSRV-2B-3 PSA-35 SNUBBER 10729 19'930504 ACC NO NSRV-2D-2 PSA-10 SNUBBER 1'9930504 ACC NO NSRV-3B-2 PSA-10 SNUBBER 31b 19930504 ACC MSRV-4D-2 PSA-10 SNUBBER 9'933 19930504 ACC NO NSRV-5C-2 PSA-10 SNUBBER 4872 19930504 ACC NO RCIC-2562-25 PSA-1/2 SNUBBER 24b2 19'930507 ACC NO RFW-929N PSA-10 SNUBBER 19930504 ACC NO RHR-150 NORTH/WE PSA-3 SN(2) 19930507 ACC NO RHR-345 EAST PSA-1 SN(2) 571 19930507 ACC

TABLE II SNUBBER TEST

SUMMARY

HANGER NARK NO. (h POSITION) TEST DATE TEST RESULT REPLACEMENT RETEST NEXT

  'DESCRIPTION h SERIAL NO ~          YR/MO/DA     ACC/REJ     SERIAL NO ~ OUTAGE: Y/N RRC-SA-17 PSA-35 SNUBBER          4217       19930505     ACC                     NO RRC-SB-16         EAST PSA-35 SN(2)            4222       19930506     ACC RRC-SB-3 PSA-100 SNUBBER           617      19930504     ACC                     NO Rt4CU-iC-8 PSA-3 SNUBBER           2'587      19930503     ACC                     NO SGT-11            BOTTOM PSA-10 SN (2)           7787       19930507     ACC                     NO TOTAL COUNT

ISI

SUMMARY

REPORT RF93A Table III Significant Indications Data Sheet Identification No o. k 1RIU-056 4RCIC(13)-13 Pipe to Penetration 180 to 0 deg 159% DAC Root Geom. 1MSU-072 26MS(1)B-20 Pipe to Pipe ID Geom at varying amplitudes. 1RHM-077 20RHR(8)A-17 Elbow to Pipe 270 to 315 deg 5.3" x .1" broad and fuzzy. Supplemental examination indicate non-relevant R-R8-111 20RRC(6)-8 Pipe to Valve Planar indication 3.6" long x 17.5% of wall. Acceptable for one operating cycle 1HV-0249 SW RING HDR Ring Hdr Support Corrosion pitting I/2" dia 200 mil deep. Acceptable by IOM SS2-PE-88-0507 1HV-0248 RCIC-53 Spring Spring settings exceed 10% of Drawing. Acceptable by engineering evaluation.

0-ISI

SUMMARY

REPORT RF93A APPENDIX A NIS-I Owner's Data Report for Inservice Inspection

WASHINGTON PUBLIC POWER 4N SUPPLY SYSTEM INTEROFFICE MEMORANDA)UM Dhm: September 9, 1993 vo: J, V. Parrish, Asst. Managing Director, Operations (1023) FROM: J. H. Swailes, WNP-2 Plant Manager (927 susszcT: DELEGATION OF AUTHORITY uzezRt! NcaI None During my absence from the Supply System from 2400 hours September 9 to September 11, 1993, J. R. Sampson is delegated to act as the WNP-2 Plant Manager, and M. J. Mann is delegated to act as the Plant Emergency Director (PED). For the periods of September 12-21 and 23-27, 1993, inclusive, G. O. Smith is delegated to act as WNP-2 Plant Manager with R. L. Webring delegated for Wednesday, September 22, 1993. Messrs. Sampson, Mann, Smith and Webring will have the full authority of the positions with the exception ofpersonnel andlor salary actions. Should my return be delayed, this delegation will continue in effect until my actual return. dm Distribution Distribution A JP Albers (927K) MJ Mann (9270) MM Monopoli (927S) JF Peters (927S) JR Sampson (927S) GO Smith (9270) RL Webring (PE27) Payroll (090) Travel (090) JHS/lb (927M) WP 102 R8 (6 QOI

FORM NIS-I OWNERS'ATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules Washington Public Power upp y ys em 3000 George Hashington Hay, Richland, HA 99352

1. Owner (Name and Address of Owner)

HNP-2, Hanford Reservation, Benton County, WA

2. Plant (Name and Address of Plant)

HNP-2 N/A

3. Plant Unit 4. Owner Certificate of Authorization (if required) 12/13/B4 N/A
5. Commercial Service Date 6. National Board Number for Unit
7. Components Inspected Manufacturer Component or Manufacturer or Installer State or National Appurtenance or Installer Serial No. Province No. Board No.

RPV CBIN Nuclear Co. T"45 29936"84H Lg Bore Pipe Bechtel N/A N/A Note (1): Th pipe examined is listed n Pages 3-24 Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8 h in. x 11 in. ~ (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. This form IE00029) may be obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017

Page 2 of 24 FORM NIS-I (back) Abstract of Examinations. Include a list of examinations and a statement concerning status of work required 10. fo t t l APProxi mately 90K o f f i requi red exami nati ons or thi s nsPecti on nterva1 i are complete. See Page 3-24 for list of examinations completed at this refueling

11. Abstract of Conditions Noted. Outage The indication in Weld 20RRC(6)-8, found at R-6, was resized. No significant change
12. Aostract ot t.orrective Measures Recommended and Taken The results of Weld 20RRC(6)-8 resizing were within the bounds of the analysis ~

performed at R-6 for continued operation. We certify that the statements made in this report are correct and the examinatio nd orrective mea-sures taken conform to the rules of the ASME Code, Section Xl.

                                     ~~     Signed    Vv PPsS                               ~ J&AJO > ~%9                       rr~t/>oQ
                                                                                                   ~.

Owner pcs~ SGC g 9/Y>/Q (4>f~'pwt'n p'9 Certificate of Authorization No. (if applicable) N/A CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel 5 have inspected to 2 ~, the components described in this Owners'ata Report during the period and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners'ata Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners'ata Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. ~d. Assoc,.

                                                                               %Simeon<

Date Comm>ss>ons 5 N' Insp r's Signature National Board, State, Province and No.

1 i OWNER i WASHINGTON PUBLIC POWER SUPPLY SYSTEN t 3000 GEORGE WASHINGTON MAY t P i 0 BOX 968 t R I CHLAND t WASHINGTON 99352 2 ~ PLANT 'NP ~ 2 i HANFORD RESERVAT I ON t BENTON COUNTY ~ MA

3. PLANT UNIT: MNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. CONNERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXANINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. METHOD DRAWING NO ~ 8-A AA BTN HD-SC01 MD 81.11 VOL RPV-101 AB 5 1 -N2 SC CRC MD 81.11 VOL RPV-101 AC 82-Q3 SC CRC WD Bl.ll VOL RPV-101 BA 01 SC VRT WDR45 81.12 VOL RPV-101 88 $ 1 SC VRT W8135 81.12 VOL RPV-101 BC 51 SC VRT M8225 Bl 12

                                                                            ~     VOL     RPV-101 BD                        51 SC VRT       MR315   81.12    VOL     RPV-101 BE                       52 SC VRT       W8 10   81.12    VOL     RPV-101 BF                       02 SC VRT WR 100        81.12    VOL      RPV-101 BG                       02 SC VRT W8190         81   12  VOL      RPV-101 BH                       Q2 SC VRT WC280         81.12    VOL      RPV-101 BJ                       83 SC VRT W8 50         81   12  VOL      RPV-101 BK                        83 SC VRT W8 170       81.12    VOL      RPV-101 BM                       53 SC VRT WP290         81   12  VOL      RPV-101 BN BP 54 SC VRT W8330 84 SC VRT MR 90 81  '2 Ble12 VOL VOL RPV-101 RPV-101 BR                       04 SC VRT MR210         81.12    VOL      RPV-101 MRP-1                    REPAIR AREA             81.51    VOL      RPV-101 DA                        BOT   HD  l1RD 8272    81.22    VOL      RPV-102 DB                        BOT   HD  HRD 8332     81 22    VOL      RPV-102 DC                        BOT   HD  NRD 8 32      81.22   VOL      RPV-102 DD                        BOT   HD  NRD 8 92      81. 22  VOL      RPV-102 DE                        BOT   HD  NRD 8152      81.22   VOL      RPV-102 DF                        BOT   HD  t1RD 8212     81 22   VOL      RPV-102 AJ                        BOT   HD  DOL MELD      81.21    VOL     RPV-102 DG                        BOT   HD  DOL /270      81.21    VOL     RPV-102 DR                        BOT   HD  DOL   /  '90  Blt21    VOL     RPV-102 8-D                N4-30-IR                  FW   NZ-IR    8 30      83.100   VOL     RPV-101 N4-30-NB                  FM N1 BORE 8       30   83.100   VOL     RPV-101 8-F                 12RHR (1) A-14           VALVE TO SE             85.50    VOL     RHR-105 12RHR (1) A-14           VALVE TO SE             85.50    SUR     RHR-105
1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEN. 3000 GEORGE WASHINGTON WAY P.O. BOX 968 RICHLAND r WASHINGTON '99352 2 ~ PLANT: WNP-2i HANFORD RESERVATIONi BENTON COUNTY t WA ~

3 ~ PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A 5 ~ COMMERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUNBER: N/A 10 ABSTRACT OF EXAMINATIONS. LIST OF EXANINATIONS: CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO ~ NETHOD DRAWING NO. 12RFW (1) AC-12 SE/STUB TO SE 85.10 VOL RFW-101 12RFW (1) AC-13 SE TO N4 85.10 VOL RFW-101 4RRC(4)8-12 SE TO VALVE 85.50 VOL RRC-109 4RRC(4)8-12 SE TO VALVE 85.50 SUR RRC-109 8-G-1 RPV STUD 35-i-7A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-7A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-14A RPV STUD 86.30 VOL RPV-101 RPV RPV STUD 35-1-14A STUD 35-1-21A RPV RPV S TUD STUD 86 '0 86.30 SUR VOL RPV-101 RPV-101 RPV STUD 35-1-21A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-28A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-28A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-35A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-3'5A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-42A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-42A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-49A RPV STUD Bbo30 VOL RPV-101 RPV STUD 35-1-49A RPV STUD Bbe30 SUR RPV-10! RPV STUD 35-1-56A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-56A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-63A RPV STUD 86 o'30 VOL RPV-101 RPV STUD 35-1-63A RPV STUD 86.30 SUR RPV-101 RPV STUD 35-1-70A RPV STUD 86.30 VOL RPV-101 RPV STUD 35-1-70A RPV STUD 86.30 SUR RPV-101 RPV NUT 36-1-7A RPV NUT 86.1O VOL RPV-101 RPV NUT 36-1-7A RPV NUT 86.10 SUR RPV-101 RPV NUT 36-1-14A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-14A RPV NUT 86.10 SUR RPV-101 RPV NUT 36-1-21A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-21A RPV NUT 86.10 SUR RPV-101 RPV NUT 36-1-28A RPV NUT 86 10 VOL RPV-101 RPV NUT 36-1-28A RPV NUT 86.10 SUR RPV-101

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM 3000 GEORGE WASHINGTON WAY P O. BOX 968 RICHLAND'ASHINGTON 9935? 2 PLANT'NP 2t HANFORD RESERVATIONS BENTON COUNTY'A
                                            ~
                                                                                                              ~

3 PLANT UNIT: WNP-2 4- OWNER CERTIFICATE OF AUTHORIZATION: N/A

5. COMMERCIAL SERVICE DATE: 12/13/1984 6 NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO.. METHOD DRAWING NO. B-G-1 RPV NUT 36-1-35A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-35A RPV NUT 86.10 SUR RPV-.101 RPV NUT 36-1-42A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-42A RPV NUT 86.10 = SUR RPV-101 RPV NUT 36-1-4'9A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-49A RPV NUT 86.10 SUR RPV-101 RPV NUT 36-1-56A RPV NUT 86.10 VOL RPV-101 RPV NUT 36-1-56A RPV NUT Bb F 10 SUR RPV-101 RPV NUT 36-1-63A RPV NUT 86.10 VOL RPV-101 RPV. NUT 36-1-63A RPV NUT 86.10 SUR RPV-101 RPV NUT 36-1-70A RPV NUT Bbe10 VOL RPV-101 RPV NUT 36-1-70* RPV NUT 86.10 SUR RPV-101 RPV WASHERS .RPV WASHER-76EA Bbe50 VT-1 RPV-101 see note 1 8-G-2 RC I C-V-13-BLT RCIC-V-65-BLT VALVE BOLTING VALVE BOLTING 87 '0 87.70 VT-1 VT-1 RCIC-102 RCI C-102 bRCIC(1)-ZSBD FLANGE BOLTING 87.50 VT-1 RCIC-102 bRCIC(1)-318U FLANGE BOLTING 87.50 VT-1 RCIC-102 bRCIC(1)-41ABD FLANGE BOLTING 87 50 VT-1 .RC I C-102 bRCIC(1)-448D FLANGE BOLTING 87 50 VT-1 RCIC-102 RHR-V-41A-DLT VALVE BOLT ING 87.70 VT-1 RHR-101 RHR-V-42C-BLT RHR-V-41C-BLT VALVE BOLT ING VALVE BOLTING 87 '0 87.70 VT-1 VT-1 RHR-103 RHR-103 RHR-V-111C-BLT VALVE'OLTING 87 '0 VT-1 RHR-103 87 '0

                                                                  ~

RHR-V-112A-BLT VALVE BOLTING VT-1 RHR-105 RHR-V-1128-BLT VALVE BOLTING 87 70 VT-1 RHR-106 MS-V-22A-BLT VALVE BOLTING 87.70 VT-1 MS-101 MS-V-28A-BLT VALVE BOLTING 87.70 VT-1 MS-101 4MS (12),-18D FLANGE BOLTING 87.50 VT-1 MS-106 4RRC (8) ZA-2BD FLANGE BOLTING 87 50 VT-1 RRC-101 4RRC(8)1A-ZBD FLANGE BOLTING 87.50 VT-1 RRC-101 RRC-V-67A-BLT VALVE BOLTING 87 70 VT-1 RRC-101 4RWCU(3)-4BD FLANGE BOLTING 87 ~ 50 VT-1 RWCU-101 Note 1: Examined washers for RPV studs 7A,14A,21A,28A,35A,42A,49A,56A,63A,70A

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEMt 3000 GEORGE WASHINGTON WAYt P.O. OOX 968t RICHLANDt WASHINGTON 99352 2 PLANT'NP 2t HANFORD RESERVATIONS BENTON COUNTY'A~
                                          ~
3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A

~ J ~ COMMERCIAL SERVICE DATE: 12/13/1984 6 ~ NATIONAL BOARD NUMBERS N/A

10. ABSTRACT QF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO METHOD DRAWING NO.

                                                                            ~

B-G-2 RWCU-V-100-BLT VALVE BOLTING 87.70 VT-1 RWCU-101 4RWCU (3) -108D FLANGE BOLTING 87.50 VT-1 RWCU-101 RWCU-V-4-BLT VALVE BOLTING 87.70 VT-1 RWCU-101 SKIRT KNUCKLE BS.10 SUR RPV-101 6SPARE-1 SPARE NZ-FLANGE 89.11 VOL RPV-102 4RCIC(13)-12 PIPE TO PIPE 89.11 VOL RCIC-101 4RCIC(13)-13 PIPE TO PEN 89.11 VOL RCIC-101 4RCIC(13)-14 PEN TO ELL 8'9. 11 VOL RCIC-101 4RCIC(13)-14 PEN TO ELL 89.11 SUR RCIC-101 4RCIC (13) -15 ELL TO PIPE 8'9. 11 VOL RC I C-101 4RCI C (13) -15 ELL TO PIPE 89.11 SUR RCIC-101 4RCIC(13)-16 PIPE TO ELL 89.11 VOL RCIC-101 4RCIC(13)-16 PIPE TO ELL 89.11 SUR RCIC-101 4RCIC(13)-17 ELL TO PIPE 8'9. 11 VOL RCIC-101 4RCIC(13)-17 . ELL TO PIPE 89.11 SUR RCIC-101 4RCI C (13) -18 PIPE TO PIPE 89 11 F VOL RCIC-101 4RCI C (13) -19 PIPE TO VLV 89.11 VOL- RCI C-101 4RCIC(13)-19 PIPE TO VLV 89.11 SUR RCIC-101 6RCIC(1)-13 VLV TO PIPE 89.11 VOL RCIC-102 6RCIC(1)-13 VLV TO PIPE 89.11 SUR RCIC-102 6RCIC(1)-14 PIPE TO ELL 89.11 VOL RCIC-102 6RCIC(1)-14 PIPE TO ELL 8'9. 11 SUR RCIC-102 bRCIC(1)-45 FLG TO NOZZLE 89.11 VOL RCIC-102 14LPCI (1) 8-4 PIPE TO ELL 89.11 VOL RHR-102 14LPCI (1) 8-4 PIPE TO ELL 89.11 SUR RHR-102 14LPCI(1)O-5 ELL TO PEN 89.11 VOL RHR-102 14LPCI (1) 8-5 ELL TO PEN 89.11 SUR RHR-102 14LPCI (1) C-1 VLV TO PIPE 89.11 VOL RHR-103 14LPCI(1) C-1 VLV TO PIPE . 89.11 SUR RHR-103 14LPCI(1)C-8 ELL TO PEN 89.11 VOL RHR-103 14LPCI(1)C-8 ELL TO PEN 8'9. 11 SUR RHR-103

1 OWNER'ASHINGTON PUBLIC POWER SUPPLY SYSTEMr 3000 GEORGE WASHINGTON WAYS PION BOX 968r RICHLAND'ASHINGTON 99352 2 PLANT WNP 2 HANFORD RESERVATIONS BENTON COUNTY'A

                                              ~              ~                                       N
3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/19S4 b. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO. METHOD DRAWING NO. 20RHR(2)-5 ELL TO PIPE 89.11 VOL RHR-104 B-J 20RHR(2)-5 ELL TO PIPE 89.11 SUR RHR-104 12RHR (1) A-10 ELL TO PIPE 89.11 VOL RHR-105 12RHR (1) A-10 ELL'O P I P E 89.11 SUR RHR-105 12RHR (1) A-13 PIPE TO VALVE 89.11 VOL RHR-105 12RHR (1) A-13 PIPE TO VALVE 89.11 SUR RHR-105 12RHR (1) 8-1 VLV TO PEN 8'9. 11 VOL RHR-106 12RHR(1)8-1 VLV TO PEN 8'9. 11 SUR RHR-106 12RHR (1) 8-7 PIPE TO ELL 89 11 F VOL RHR-106 12RHR (1) 8-7 PIPE TO ELL ~ 89o11 SUR RHR-106 12RHR (1) 8-9 PIPE TO VLV 89.11 VOL RHR-106 12RHR ( 1 ) 8-9 PIPE TO VLV 89.11 SUR RHR-106 12RHR (1) 8-12LUO ELL SEAM 8'9. 12 VOL RHR-106 12RHR (1) 8-12LUO ELL SEAM 89. 12 SUR RHR-106 12RHR(1)B-12 ELL TO PIPE 89. 11 SUR RHR-106 12RHR(1)B-13 PIPE TO VLV 89.11 VOL RHR-106 12RHR (1) 8-13 P IPE TO VLV 89.11 SUR RHR-106 26MS(1)A-7/SMSR-4A PIPE TO SWL 89.31 VOL MS-101 26MS(1)A-7/SMSR-4A 26MS(1)A-7/8MSR-3A PIPE TO SWL PIPE TO SWL 89 89

                                                                       '1
                                                                       '1         SUR VOL MS-101 MS-101 26MS(1)A-7/SMSR-3A              PIPE TO SWL      89.31          SUR MS-101 26MS(1)D-7/SMSR-4D              P IPE TO SWL     89.31         VOL  MS-104 26MS ( 1 ) D-7/SMSR-4D          PIPE TO SWL      8'9. 31        SUR MS-104 26MB (1) D-7/SMSR-3D            PIPE TO SWL      8'9. 31        VOL MS-104 26MS ( 1 ) D-7/SMSR-3D          PIPE TO SWL      89+31          SUR MS-104 26MS (1) D-7/SMSR-2D            PIPE TO SWL      89.31          VOL  MS-104 26MS(l)D-7/SMSR-2D              PIPE TO SWL      89.31          SUR  MS-104   '0 26MS (1) D-7/8MSR-1D           PIPE TO SWL      89.31          VOL  MS-104   00 26MS (1) D-7/SMSR-1D            PIPE TO SWL      89.31          SUR  MS-104    CD eMS (1) D-S                   PIPE TO ELL              '9.11 VOL  MS-104    O 26MS ( 1 ) D-8                 PIPE TO ELL      89.11          SUR  MS-104 2&MS (1) D-SLDI                ELL SEAM         89.12          VOL  MS-104 26MS (1) D-SLDI                ELL SEAM         89.12          SUR  MS-104

1 ~ OMNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM 3000 GEORGE WASHINGTON WAY P.O. BOX 968 RICHLAND>> WASHINGTON '9'9352 2 ~ PLANT WNP 2r HANFORD RESERVATION>> BENTON COUNTYt WA ~

3. PLANT UNIT: MNP-2 4 OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COHNERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS>> LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. NETHOD DRAWING NO. B-J 26NS (1) D-8LDO ELL SEAN 89.12 VOL MS-104 26NS ( 1 ) D-8LDO ELL SEAN 89.12 SUR NS-104 26NS (1) D-9LUI ELL SEAN 89.12 VOL NS-104 26NS (1) D-9LUI ELL SEAN 89.12 SUR NS-104 26NS(1)D-9LUO ELL SEAN 8'9. 12 VOL NS-104 26NS (1) D-9LUO ELL SEAM 89.12 SUR MS-104 26NS (1) D-9 ELL TO PIPE 8'9. 11 VOL NS-104 26NS(1)D-9 ELL TO PIPE 89. 11 SUR NS-104 26NS(1)D-lb VALVE TO PENE 89.11 VOL NS-104 26NS(1)D-16 VALVE TO PENE 89.11 SUR NS-104 26NS(1)D-17 PENE TO PIPE 8'9 ~ 1 1 VOL NS-104 t15-V-28D/2NS(9)-4 DRAIN CONN 89. 11 SUR NS-104 4t1S (12) -2 FLANGE/REDUCER 89.11 VOL NS-106 24RFM(1) A-1 VALVE TO PIPE 89 11 VOL RFW-101

                                                                    '1 F

24RFM(1) A-1/5RFW (11) -4 PIPE TO MOL 89 VOL RFW-101 5RFW (11) A-2 SLEEVE TO WOL 8'9. 11 VOL RFW-101 5RFW(11) A-2 SLEEVE TO WOL 89>>ll SUR RFW-101 24RFW ( 1 ) A-2 PIPE TO VALVE 89>> 1 1 VOL RFW-101 24RFW (1) A-3 VALVE TO PENE 89.11 VOL RFW-101 24RFW(1) A-5 VALVE TO P IPE 89.11 VOL RFW-101 24RFM(l) A-6 PIPE TO ELL 89.11 VOL RFW-101

                   '24RFW ( 1 ) A-7            ELL TO PIPE      89.11     VOL   RFM-101 24RFW ( 1 ) A-8             PIPE TO VALVE    89.11     VOL   RFW-101 24RFW(1) A-8                PIPE TO VALVE    89.11     SUR   RFW-101 24RFW(1) A-15               PIPE TO TEE      89.11     VOL   RFW-101 24RFW(1) A-17               PIPE TO REDUCER  89. 11    VOL   RFW-101 24RFM(1) A-17               PIPE TO REDUCER  89.11     SUR   RFW-101 18RFW (1) A-1              REDUCER TO PIPE  89.11     VOL   RFW-101 18RFW(1) A-1               REDUCER TO PIPE  89.11     SUR   RFW-101 18RFW (1) A-2              PIPE TO TEE      89.11     VOL   RFW-101 18RFM ( 1 ) A-2 18RFM(1) A-4 PIPE TO TEE PIPE TO REDUCER 89 89.11 ll  SUR VOL RFW-101 RFW-101 18RFW(1) A-4               PIPE TO REDUCER  89.11     SUR   RFW-101 0

0

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM> 3000 GEORGE WASHINGTON WAY>,P.O. BOX 968t RICHLAND'ASHINGTON 99352 2 ~ PLANT: WNP-2 ~ HANFORD RESERVATIONS BENTON COUNTY'A~
3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A 5e CONt1ERCIAL SERVICE DATE: 12/13/19S4 b. NATIONAL BOARD NUMBER: N/A 10 ~ ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION NETHOD DRAWING NO. B-J 24RFM (1) 8-1 VALVE TO PIPE 8'9. 11 VOL RFM-102 24RFW (1) B-l/5RFM (11) -4 P IPE TO MOL 89.31 VOL RFW-102 5RFW ( 1 1 ) 8-2 SLEEVE TO MOL 89.11 VOL RFM-102 24RFW (1) 8-2 PIPE TO VALVE 89.11 VOL RFW-102 24RFW (1) 8-3 VALVE TO PENE 89.11 VOL RFW-102 24RFW(1) 8-8 PIPE TO VALVE 89.11 VOL RFW-102 12RFW (1) BF-2 PIPE TO ELL 89 11 F VOL RFM-102 12RFW (1) BF-2 PIPE TO ELL 89.11 SUR RFW-102 12RFM(1) BF-7 PIPE TO ELL 89.11 VOL RFM-102 12RFW (1) BF-7 PIPE TO ELL 89.11 SUR RFW-102 12RFW(i)BF-8 ELL TO PIPE 89.11 VOL RFW-102 12RFW (1) BF-8 ELL TO PIPE 8'9. 11 SUR RFW-102 24RFW (1) 8-17 PIPE TO REDUCER 89.11 VOL RFM-102 24RFM(1) 8-17 PIPE TO REDUCER 89.11 SUR RFW-102 18RFW (1) B-l REDUCER TO PIPE 8'9. 11 VOL RFW-102 18RFW (1) 8-1 REDUCER TO PIPE 8'9 11 SUR RFW-102 18RFM(1) 8-4 PIPE TO REDUCER 89.11 VOL RFM-102 18RFW(1) 8-4 PIPE TO REDUCER 89 F 11 SUR RFW-102 24RRC (1) A-20/12RRC (7) -4S PIPE TO SWL 89.31 VOL RRC-101 24RRC (1) A-20/12RRC (7) -4S PIPE TO SWL 89 31 SUR RRC-101 24RRC (2) 8-8/4RRC (8) -4S PIPE TO SWL 89.31 VOL RRC-102 24RRC (Z) 8-8/4RRC (a) -4S PIPE TO SWL 89.31 SUR RRC-10Z 4RRC (8) 28-1 SWL TO PIPE 89 11 VOL RRC-102 4RRC(8)28-1 SWL TO PIPE 89.11 SUR RRC-102 4RRC(S)28-2 4RRC(8)28-2 PIPE TO FLANGE PIPE TO FLANGE 89 89.11 ll VOL SUR RRC-102 RRC-102 24RRC(2)8-S/4RRC(4)-4S PIPE TO SWL 8'9. 31 VOL RRC-102 24RRC(2)8-8/4RRC(4)-45 PIPE TO SWL 89.31 SUR RRC-102 24RRC (2) 8-9 PIPE TO ELL 89.11 VOL RRC-102 24RRC(2)8-9LDO ELL SEAN 8'9. 12 VOL RRC-102 24RRC(2)B-9LDI ELL SEAN 89.12 VOL RRC-102 24RRC (2) 8-10LUO ELL SEAN 89.12 VOL RRC-102 24RRC (2) 8-10LUI ELL SEAN 89.12 VOL RRC-102

1 ~ OWNER t WASHINGTON PUBLIC POWER SUPPLY SYSTEM ~ 3000 GEORGE WASHINGTON WAY r P ~ 0 ~ BOX 96S ~ RICHLAND'ASHINGTON 993'52 2 PLANT'NP 2t HANFORD RESERVATIONS BENTON COUNTY'A ~

3. PLANT UNIT: WNP-2 4 OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/19S4 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO. METHOD DRAWING NO. B-J 24RRC (2) 8-'10 ELL TO PUMP 89.11 VOL RRC-102 24RRC(1)B-11 PUMP TO PIPE 89.11 VOL RRC-102 24RRC(1)B-11LD 4RRC(8)18-1 4RRC(8)18-1 PIPE SEAM SWL TO PIPE SWL TO PIPE 89 'l 89.12 89.11 VOL VOL SUR RRC-102 RRC-102 RRC-102 4RRC (8) 18-2 PIPE TO FLANGE 89.11 VOL RRC-102 4RRC(8)18-2 PIPE TO FLANGE 8'9. 11 SUR RRC-102 24RRC 1) 8-18/12RRC (7)-4S PIPE TO SWL

                          <                                         89.31    VOL    RRC-102 24RRC (1) 8-18/12RRC (7)-4S P IPE TO SWL        89.31    SUR    RRC-102 16RRC(l)8-1                    CROSS TO PIPE    89.11    VOL    RRC-102 16RRC(l) 8-1/12RRC( 1) -N2G PIPE TO SWL         89.31    VOL    RRC-102 16RRC(l) B-l/12RRC( 1) -N2G PIPE TO SWL         8'9. 31  SUR    RRC-102 16RRC (1) 8-1/12RRC ( 1) -N2F PIPE TO SWL       89.31    VOL    RRC-102 16RRC(1) 8-1/12RRC( 1) -N2F PIPE TO SWL         89.31    SUR    RRC-102 16RRC (1) 8-3/12RRC ( I ) -N2J PIPE TO SWL      89.31    VOL    RRC-102 16RRC(1) 8-3/12RRC( 1)-N2J PIPE TO SWL          89.31    SUR    RRC-102 16RRC(l) 8-3/12RRC( 1) -N2K PIPE TO SWL         89' 31   VOL    RRC-102 16RRC(1) B-3/12RRC( 1) -N2K PIPE TO SWL 12RRC ( 1) -NBH-1              REDUCER TO PIPE 89  '1 8'9e 11 SUR VOL RRC-102 RRC-102 12RRC (1) -N2H-1LD             PIPE SEAM        8'9. 12  VOL    RRC-102 20RRC (6) -S                   PIPE TO VALVE    89 ~ 11  VOL    RRC-105 12RRC (7) 8-2LDI               ELL SEAM         89el2    VOL    RRC-107 12RRC(7)B-2LDI                 ELL SEAM         89.12    SUR    RRC-107 12RRC(7)B-2LDO                 ELL SEAM         8'9. 12  VOL    RRC-107 12RRC(7)8-2LDO                 ELL SEAM         89 ~ 12  SUR    RRC-107 12RRC(7)8-3LUI 12RRC(7)8-3LUI ELL SEAM ELL SEAM 89  '2 89.12 VOL SUR RRC-107 RRC-107 12RRC(7)B-3LUO                 ELL SEAM         8'9. 12  VOL    RRC-107       CO 12RRC(7)B-3LUO                 ELL SEAM         89.12    SUR    RRC-107        CD 12RRC(7)8-3                    ELL TO PIPE      8'9. 11  VOL    RRC-107        CO 12RRC<7)8-3                    ELL TO PIPE      89.11    SUR    RRC-107        0 12RRC(7)8-3LD                  PIPE SEAM        89.12    VOL    RRC-107 12RRC(7)8-3LD                  PIPE SEAM        89.12    SUR    RRC-107
1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTENt 3000 GEORGE WASHINGTON WAYS PION BOX 968t RICHLAND~ WASHINGTON 99352 2 ~ PLANT: MNP-2r HANFORD RESERVATIONS BENTON COUNTYt WA 3 PLANT UNIT: MNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/1984 b. NATIONAL BOARD NUNBER: N/A 10 ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE. CATEGORY IDENTIFICATION NO. DESCR I PT I ON ITEN NO. METHOD DRAWING NO. B-J 4RRC (4) 8-4 PIPE TO TEE 89.11 VOL RRC-109 4RRC (4) 8-5 TEE TO PIPE 89.11 VOL RRC-109 4RRC (4) 8-10 ELL TO PIPE 89.11 VOL RRC-109 4RRC(4)8-10 ELL TO PIPE 89.11 SUR RRC-109 6RWCU(3)-20 PIPE TO VALVE 89.11 VOL RWCU-101 6RWCU(3)-21 VALVE TO PIPE 8'9. 11 VOL RWCU-101

                   -bRWCU(3)-22               PIPE  TO PENE    89.11          VOL   RWCU-10.1 6RWCU(3)-23               PEN TO ELL       8'9.       1'1 VOL   RWCU-101 6RWCU(3)-'24              ELL TO PIPE      89.        11  VOL   RWCU-101 6RWCU(3)-25               PIPE TO ELL       8'9.      11  VOL   RWCU-101 6RMCU(3)-26               ELL TO PIPE       89.11         VOL   RWCU-101 8-K-1           RCIC-1C-2 (M)

RHR-231 (W) 8 WELDED LUGS 4 WELDED LUGS 810 810.10

                                                                          '0  SUR SUR RCIC-101 RHR-101 RHR-483(M)                4 WELDED LUGS     810.10        SUR   RHR-102 NS FLUED HEAD 8           FLUED HEAD WELD   810 '0        SUR   NS-102 NS-HD-2(W)                4 WELDED LUGS     810.10        SUR   NS-104 NS FLUED HEAD D           FLUED HEAD WELD   810 10    F   SUR   f1S-104 RFM-186 (W)               6.WELDED LUGS     810.10        SUR   RFW-101 RFW-159 (W)               4 WELDED LUGS                   SUR   RFW-101 RFW-162 (W)

RFW-1S3 (W) 6 WELDED LUGS 4 WELDED LUGS 810.10'10 810.10

                                                                          '0  SUR SUR RFW-102 RFW-102 RRC-SA-2(M)               4 WELDED LUGS     810.10        SUR   RRC-101 RRC-SA-1 (W)              4 WELDED LUGS     810 '0        SUR   RRC-101 RRC-SB-16(W)              8 WELDED LUGS     810.10        SUR   RRC-102 8-P             RPV-PB-101 (L)            LK  PRES BNDRY    815.10        VT-2  RPV-101 RPV-PB-102 (L)            LK  PRES BNDRY    815.10        VT-2  RPV-102 RCIC-PB-101(L)            LK  PRES BNDRY    815.50        VT-2  RCIC-101 RCIC-PB-102(L)            LK  PRES BNDRY    815.50        VT-2  RC I C-102 HPCS-PB-101 (L)           LK  PRES BNDRY    815.50        VT-2  HPCS-101 LPCS-PB-101 (L)

RHR-PB-101 (L) LK LK PRES BNDRY PRES BNDRY 815 815.50

                                                                           '0 VT-2 VT-2 LPCS-101 RHR-101

1 ~ OWNER WASHINGTON PUBLIC POWER SUPPLY SYSTEM 3000 GEORGE WASHINGTON WAY r P ~ 0 ~ BOX 968 r

                                                ~

RICHLAND'ASHINGTON 9935? ? PLANT'NP 2t HANFORD RESERVATIONS BENTON COUNTYr WA ~ 3~ PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORI EAT!ON: N/A 5e COMMERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A

10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO. METHOD DRAWING NO>> B-P RHR-PB-102 (L) LK PRES BNDRY 815.50 VT-2 RHR-102 RHR-,PB-103 (L) LK PRES BNDRY 815.50 VT-2 RHR-103 RHR-PB-104(L) LK PRES BNDRY 815.50 VT-2 RHR-104 RHR-PB-105(L) LK PRES BNDRY 815 50

                                                                  ~      VT-2 RHR-105 RHR-PB-106(L)             LK PRES  BNDRY  815 50
                                                                  ~      VT-2 RHR-106 MS-PB-101 (L)             LK PRES  BNDRY  815.50      VT-2 MS-101 MS-PB-102 (L)             LK  PRES BNDRY  915 50
                                                                  ~      VT-2 MS-102 MS-PB-103 (L)             LK  PRES BNDRY  815 50
                                                                  ~      VT-2 MS-103 MS-PB-104 (L)            LK  PRES BNDRY  915.50      VT-2 MS-104 MS-PB-105 (L)            LK  PRES BNDRY  815 50F     VT-2 MS-105 MS-PB-106 (L)            LK  PRES BNDRY  915.50      VT-2 MS-106 RFW-PB-101 (L)           LK'PRES BNDRY   815e50      VT-2 RFW-101 RFW-PB-102 (L)           LK PRES BNDRY   915.50      VT-2 RFW-102 RFW-PB-103 (L)           LK PRES BNDRY   815.50      VT-2 RFW-103 RRC-PB-101(L)

RRC-PB-102(L) LK PRES BNDRY LK PRES BNDRY 81'5 815.50

                                                                   '0    VT-2 VT-2 RRC-101 RRC-102 RRC-PB-103(L)            LK PRES BNDRY   815.50      VT-2 RRC-103 RRC-PB-104(L)            LK PRES BNDRY   815.50      VT-2 RRC-104 RRC-PB-105 (L)           LK PRES BNDRY   815e50      VT-2 RRC-105 RRC-PB-106 (L)           LK PRES BNDRY   815.50      VT-2 RRC-106 RRC-PB-107 (L)           LK PRES BNDRY   915.50      VT-2 RRC-107 RRC-PB-108(L)            LK PRES BNDRY    815.50     VT-2 RRC-108 RRC-PB-10'V(L)           LK PRES BNDRY    915   ~ 50 VT-2 RRC-109 RRC-PB-110(L)            LK PRES BNDRY    815   ~ 50 VT-2 RRC-110 RRC-PB-111(L)            LK PRES BNDRY    815   ~ 50 VT-2 RRC-1 1 1 RWCU-PB-101(L)           LK PRES BNDRY    915   ~ 50 VT-2 RWCU-101 SLC-PB-101(L)            LK PRESS BNDRY   815   ~ 50 VT-2 SLC-101 C-C            RHR-188 (W)               4 WELDED LUGS   C3. 40     SUR  RHR-201 RHR-41(W)              4- WELDED LUGS   C3.40      SUR  RHR-203 RHR-420(W)                4 WELDED LUGS   C3.40      SUR  RHR-203 RHR-76(W)                 4 WELDED LUGS   C3.40      SUR  RHR-205 RHR-917N(W)               4 WELDED LUGS   C3.40      SUR   RHR-205
1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTENr 3000 GEORGE WASHINGTON WAYr P.O. BOX 968r RICHLAND'ASHINGTON 99352 2 PLANT WNP 2r HANFORD RESERVATIONr BENTON COUNTYr
                                       ~

WA ~

3. PLANT UNI T: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. CONNERCIAL SERVICE DATE: 12/13/1984 6 NATIONAL BOARD NUNBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO.. DESCRIPTION ITEN NO. METHOD DRAWING NO ~ C-C RHR-918N (M) 8 WELDED LUGS C3.40 SUR RHR-207 RHR-924N(W) 4 WELDED LUGS C3.40 SUR RHR-207 RHR-495(W) 8 WELDED LUGS C3 ~ 40 SUR RHR-207 RHR-185 (W) 4 WELDED LUGS C3.40 SUR RHR-207 RHR-218 (W) 8 WELDED LUGS C3.40 SUR RHR-207 RHR-184 (W) 16 WELDED LUGS C3.40 SUR RHR-207 MS-71 (M) 2 WELDED LUGS C3.40 SUR MS-204 C-F-2 6RCIC(6)-1 TEE TO PIPE C5.51 VOL RCIC-205 10HPCS('9)-1 TEE TO PIPE CS.51 VOL HPCS-202 18RHR (1) A-4 PIPE TO ELL C5.51 VOL RHR-201 18RHR (1) A-4 PIPE TO ELL C5r51 SUR- RHR-201 18RHR (1) A-5 ELL TO PIPE C5.51 VOL RHR-201 18RHR (1) A-5 ELL TO P I PE C5.51 SUR RHR-201 1SRHR(1) A-6 PIPE TO ELL C5.51 VOL RHR-201 18RHR (1) A-6 TO ELL 'IPE C5.51 SUR RHR-201 1SRHR (1) A-21 PIPE TO TEE C5.51 VOL RHR-201 1SRHR (1) A-21 PIPE TO TEE C5 ~ 51 SUR RHR-201 18RHR (2) A-12 PIPE TO TEE C5 ~ 51 VOL RHR-205 18RHR (2) A-12 P I PE TO TEE C5.51 SUR RHR-205 24RHR(2)A-2 TEE TO PIPE C5.51 VOL RHR-205 24RHR(2)A-2 TEE TO PIPE C5.51 SUR RHR-205 24RHR(2)A-6 FLANGE TO ELL C5r51 VOL RHR-205 24RHR(2)A-6 FLANGE TO ELL C5 ~ 51 SUR RHR-205 24RHR (3) A-10 ELL TO TEE C5.51 VOL RHR-205 24RHR (3) A-10 ELL TO TEE C5 ~ 51 SUR RHR-205 20RHR (8) A-1B FLANGE TO PIPE C5.51 VOL RHR-206 20RHR (8) A-1B FLANGE TO PIPE C5.51 SUR RHR-206 20RHR (8) A-4 PIPE. TO PIPE C5.51 VOL RHR-206 20RHR (8) A-4 PIPE TO PIPE C5.51 SUR RHR-206 20RHR(8)A-17 ELL TO PIPE C5.51 VOL RHR-206 20RHR (8) A-17 ELL TO P IPE C5.51 SUR RHR-206 14RHR (1) C-1 RED TO PIPE C5r51 VOL RHR-210

l. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEMt 3000 GEORGE WASHINGTON WAYi P.O. BOX WASHINGTON 99352 2 PLANT: WNP-2 ~ HANFORD RESERVATIONS BENTON COUNTY'A~

968'ICHLANDt

3. PLANT UNIT: WNP-2 4 OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO. METHOD DRAWING NO. C-F-2 14RHR (1) C-1 RED TO PIPE C5.51 SUR RHR-210 14RHR < 1) C-6 PIPE TO PIPE C5.51 VOL RHR-210 14RHR(1)C-6 PIPE TO PIPE C5 ~ 51 SUR RHR-210 24RHR<3)-2 VALVE TO P IPE C5 51 VOL RHR-211 24RHR(3)-2 VALVE TO PIPE C5.51 SUR RHR-211 24RHR (3) -2/3 (17) -1 BRANCH CONN C5.81 SUR RHR-211 24RHR(3)-6 ELL TO PIPE C5.51 VOL RHR-211 24RHR(3)-6 ELL TO P IPE C5.51 SUR RHR-211 24RHR (3) -S ELL TO PIPE C5.51 VOL RHR-211 24RHR(3)-8 ELL TO PIPE C5.51 SUR RHR-211 26MS(1)A-19/3V-20 DRAIN CONN C5.81 SUR MS-201 30MS (1) A-7LU PIPE LONG SEAM C5.52 VOI MS-201 30MS(1)A-7LU PIPE LONG SEAM C5.52 SUR MS-201 30MS (1) A-7 PIPE TO ELL C5.51 VOL MS-201 30MS ( 1 ) A-7 PIPE TO ELL C5 ~ 51 SUR MS-201 30MB (1) A-7LDI ELL SEAM C5 52 VOL MS-201 30MS (1) A-7LDI ELL SEAM C5 52 SUR MS-201 30MS ( 1 ) A-7LDO ELL SEAM C5.52 VOL MS-201 30MB ( 1 ) A-7LDO ELL SEAM C5.52 SUR MS-201 30MS (1) A-16LUO ELL SEAM C5.52 VOL MS-201 30MS (1) A-16LUO ELL SEAM C5.52 SUR MS-201 30MS (1) A-16 ELL TO PIPE C5.51 VOL MS-201 30MS (1) A-16 ELL TO P IPE C5.51 SUR MS-201 30MS (1) A-16LD PIPE LONG SEAM C5 ~ 52 VOL MS-201 30MS (1) A-16LD PIPE LONG SEAM C5.52 SUR MS-201 18MS ( 1 ) A-3 ELL TO PIPE C5 ~ 51 VOL MS-201 18MS (1) A-3 ELL TO PIPE C5.51 .SUR MS-201 1SMS (1) A-8 PIPE TO ELL C5.51 VOL MS-201 QO CD 1SMS (1) A-8 PIPE TO ELL C5.51 SUR MS-201 1SMS (1) A-'9 ELL TO P IPE C5.51 VOL MS-201 4 O 18MS(i)A-9 ELL TO PIPE C5.51 SUR MS-201 26MS(1)B-20LU PIPE LONG SEAM C5.52 VOL MS-202 26MS (1) B-20LU PIPE LONG SEAM C5.52 SUR MS-202

0 1 ~ OWNER WASHINGTON PUBLIC POWER SUPPLY SYSTEMr 3000 GEORGE WASHINGTON WAYr P 0 BOX 968t RICHLANDr WASHINGTON 99352 2 ~ PLANT WNP 2t HANFORD RESERVATIONS BENTON COUNTYt WA ~

3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF. AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. METHOD DRAWING NO ~ C-F-2 26NS (1) 8-20 PIPE TO PIPE C5.51 VOL NS-202 26NS (1) 8-20 PIPE TO PIPE C5.51 SUR NS-202 26MS (1) 8-20LD PIPE LONG SEAN C5.52 VOL NS-202 26NS (1) 8-20LD PIPE LONG SEAM C5 ~ 5? SUR NS-202 26NS(1)8-20/3V-20 DRAIN CONN C5.S1 SUR NS-202 26NS(1)C-20/3V-20 DRAIN CONN C5.81 SUR NS-203 24NS(1)-2 PIPE TO VALVE C5.51 VOL NS-205 24NS (1) -2 PIPE TO VALVE C5.51 SUR NS-205 SCRD (12) A-1S/2FLG P I PET TO EL C5.70 SUR CRD-201 8CRD ( 12) A-22/?FLG P IPET TO EL C5.70 SUR CRD-201 SCRD (12) 8-18/2FLG PI PET TO EL C5.70 SUR CRD-202 8CRD(12)8-22/2FLG P IPET TO EL C5.70 SUR CRD-202 D-A RCC-PB-303(H) HYDRO TEST BNDY D1.10 VT-2 RCC-303 RCC-PB-304(H) HYDRO TEST BNDY D1.10 VT-2 RCC-304 NSRV-18-2(W) WELDED ATTACH D1.30 VT-3 MS-305 NS-281 (W) MELDED ATTACH D1 ~ 40 VT-3 NS-305 NS-282 (W) WELDED ATTACH D1.40 VT-3 NS-305 D-8 SW-59(W) WELDED ATTACH D2.20 VT-3 SW-301 SM-62(W) WELDED ATTACH D2 ~ 20 VT-3 SW-301 SW-63(W) WELDED ATTACH D2.20 VT-3 SW-301 SM-64(W) WELDED ATTACH D2-?0 VT-3 SM-301 SW-66(W) WELDED ATTACH D2.20 VT-3 SW-301 SW-71(M) WELDED ATTACH D2.20 VT-3 SW-301 SM-173 (W) WELDED ATTACH D2.20 VT-3 SW-301 SW-68(M) WELDED ATTACH D2.20 VT-3 SW-301 SW-70(W) WELDED ATTACH D2.20 VT-3 SW-301 SW-73(W) WELDED ATTACH D2.20 VT-3 SM-301 SW-200(W) WELDED ATTACH D2.20 VT-3 SM-301 SW-434(W) WELDED ATTACH D2 20 VT-3 SW-301 SW-122(W) WELDED ATTACH D2.40 VT-3 SW-301 SW-123(W) WELDED ATTACH D2.20 VT-3 SM-301

i. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEMr 3000 GEORGE WASHINGTON WAYr PION BOX 968r RICHLANDr WASHINGTON 99352 2. PLANT- WNP-2r HANFORD RESERVA TIONr BENTON COUNTYr WA ~
3. PLANT UNIT '- WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERC! AL SERVICE DATE: 12/13/1984 6. NATIONAl BOARD NUMBER- N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO DESCRIPTION ITEM NO. METHOD DRAWING NO. 0-8 SW-358 (W) MELDED ATTACH D2.20 VT-3 SW-304 SM-357 (M) WELDED ATTACH D2 20 VT-3 SM-304 SW-3'56(W) MELDED ATTACH D2.20 VT-3 SW-304 SW-354(W> WELDED ATTACH D2.20 VT-3 SW-304 SW-426(W) WELDED ATTACH D2.20 VT-3 SM-304 SW-355(W) WELDED ATTACH D2 ~ 20 VT-3 SW-304 SW-22(W) WELDED ATTACH D2.40 VT-3 SM-305 SW-30S(W) WELDED ATTACH D2.20 VT-3 SW-306 SW-307 (W) WELDED ATTACH D2.20 VT-3 SW-306 SW-266 (W) WELDED ATTACH D2.20 VT-3 SM-306 SW-267(W) WELDED ATTACH D2.20 VT-3 SM-306 SW-2'92 (W) WELDED ATTACH D2 ~ 20 VT-3 SW-306 SW-293 (W) WELDED ATTACH D2.20 VT-3 SM-306 SW-294(W> WELDED ATTACH D2.20 VT-3 SW-306 SW-306 (M) WELDED ATTACH D2.20 VT-3 SW-306 SW-302 (M) WELDED ATTACH D2.20 VT-3 SW-306 SW-312(M) WELDED ATTACH D2.20 VT-3 SM-306 SW-80(W) WELDED ATTACH D2.20 VT-3 SW-307 SW-el(M) WELDED ATTACH D2.20 VT-3 SW-307 SW-914N(W) WELDED ATTACH D2.30 VT-3 SW-307 SW-917N(M) WELDED ATTACH D2 ~ 40 VT-3 SW-307 SW-83(W) WELDED ATTACH D2.20 VT-3 SM-307 SM-84(M) WELDED ATTACH D2.PO VT-3 SM-307 SW-195(W) WELDED ATTACH D2.20 VT-3 SW-307 SW-943N(M) WELDED ATTACH D2.20 VT-3 SW-307 SW-19 (M) WELDED ATTACH D2.20 VT-3 SW-307 SW-919N(W) WELDED ATTACH D2.20 VT-3 SM-307 'O SW-921M (W) WELDED ATTACH D2.20 VT-3 SM-307 CCI A SW-922N(M) WELDED ATTACH D2.20 VT-3 SW-307 SW-923N(W) WEl DED ATTACH D2.20 VT-3 SW-307 O SW-924N(W) WELDED ATTACH D2.20 VT-3 SW-307 SW-92SN(M) WELDED ATTACH D2.20 VT-3 SW-307 SW-926N(W) WELDED ATTACH D2.20 VT-3 SM-307

0 1 OWNER'ASHINGTON PUBLIC POWER SUPPLY SYSTENr 3000 GEORGE WASHINGTON WAYr P 0 BOX 968r RICHLANDr WASHINGTON 99352 2. PLANT: WNP-2r HANFORD RESERVATIONr BENTON COUNTYr WA

3. PLANT UNIT: MNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. CONNERCIAL SERVICE DATE: 12/13/1984 6 ~ NATIONAL BOARD NUNBER: N/A 10 ~ ABSTRACT OF EXANINATIONS~ LIST OF EXANINATIONS:

CODE CATEGORY IDENTIFICATION NO r DESCRIPTION ITEN NO. NETHOD DRAWING NO. D-D SW-927N(W) WELDED ATTACH D2.20 VT-3 SW-307 SW-928N(W) WELDED ATTACH D2. '20 VT-3 SW-307 SW-929N(W) WELDED ATTACH D2.20 VT-3 SM-307 SM-935N(W) WELDED ATTACH D2.20 VT-3 SW-307-SW-13 (W) WELDED ATTACH D2.20 VT-3 SW-309 SW-966N (W) WELDED ATTACH 'D2. 20 VT-3 SM-3 1"2 SW-1022N (W) WELDED ATTACH D2.20 VT-3 SW-313 SW-1032N (W) WELDED ATTACH D2.20 VT-3 SM-313 SW-954N(W) WELDED ATTACH D2.20 VT-3 SW-314 CCK-PB(H) HYDRO PB D2.10 VT-2 N/A D-C FPC-64(W) WELDED ATTACH D3.20 VT-3 FPC-301 FPC-PB-301(H) HYDRO PRES BNDR D3.10 VT-2 FPC-301 FPC-PB-302(H) HYDRO PRES BNDR D3.10 VT-2 FPC-302 FPC-PB-303(H) HYDRO PRES BNDR D3.10 VT-2 FPC-303 FPC-PB-304(H) HYDRO PRES BNDR D3.10 VT-2 FPC-304 FPC-48(W) WELDED ATTACH D3.20 VT-3 FPC-307 FPC-50(W) WELDED ATTACH D3r20 VT-3 FPC-307 FPC-PB-307(H) HYDRO PRES BNDR D3.10 VT-2 FPC-307 FPC-PB-309(H) HYDRO PRES BNDR D3.10 VT-? FPC-30S FPC-PB-310 (H) HYDRO PRES BNDR D3.10 VT-2 FPC-308 FPC-PB-311(H) HYDRO PRES BNDR D3.10 VT-2 FPC-308 FPC-PB-'324(H) HYDRO PRES BNDR D3.10 VT-2 FPC-308 FPC-PB-325(H) HYDRO PRES BNDR D3.10 VT-? FPC-308 FPC-PB-32*(H) HYDRO PRES BNDR D3.10 VT-~ FPC-308 IWF RHR-520 SPRING F-X VT3H RCIC-102 RHR-979N STRUT F-X VT3H RCIC-102 RCIC-102 STRUT F-X VT3H RCIC-102 RCIC-103 STRUT F-X VT3H RCIC-102 RCIC-104 SPRING F-X- VT3H RCI C-102 RC I C-942N SPRING F-X- VT3H RCIC-102 R C I C-'93 9 N STRUT F-X VT3H RCIC-102

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM 3000 GEORGE WASHINGTON WAY P.O. BOX 968 R I CHLAND t WASH I NGTON 99352 2 ~ PLANT 'NP 2 t HANFORD RESERVAT I ON i BENTON COUNTY ~ WA ~

3 ~ PLANT UNIT: -WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A

5. COMl1ERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXANINATIONS. LIST OF EXANINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. METHOD DRAWING NO. IHF RCIC-56 SPRING F-X VT3H RCI C-204 RCIC-47 BOX F-X VT3H RCIC-204 RCIC-902N SPRING F-X VT3H RCIC-204 RCIC-53 SPRING F-X VT3H RCIC-204 RCIC-9Q1N STRUT F-X VT3H RCIC-204 HPCS-31 STRUT F-X VT3H HPCS-202 HPCS-32 SPRING F-X VT3H HPCS-202 HPCS-33 BOX/STRUT F-X VT3H HPCS-202 HPCS-34 SPRING F-X VT3H HPCS-202 HPCS-921N STRUT F-X VT3H HPCS-205 HPCS-12 STRUT F-X VT3H HPCS-205 HPCS-922N STRUT F-X VT3H HPCS-205 LPCS-13 SPRING F-X VT3H LPCS-101 RHR-504 SPRING F-X VT3H RHR-105 RHR-SA-40 PSA-1Q SNUBBER F-X VT3H RHR-105 RHR-SA-39 PSA-10 SN (2) F-X VT3H RHR-105 RHR-SA-38 PSA-10 SNUBBER F-X VT3H RHR-105 RHR-506 SPRING F-X VT3H RHR-105 RHR-SA-36 PSA-35 SNUBBER F-X VT3H RHR-105 RHR-SA-35 PSA-10 SNUBBER .F-X VT3H RHR-105 RHR-159 STRUT F-X VT3H RHR-201 RHR-161 SPRING F-X VT3H RHR-201 RHR-162 STRUT F-X VT3H RHR-201 RHR-163 STRUT F-X VT3H RHR-201 RHR-164 STRUT F-X VT3H RHR-201 RHR-165 STRUT F-X VT3H RHR-201 RHR-188 SPRING F-X VT3H RHR-201 RHR-970N ANCHOR F-X VT3H RHR-201 RHR-419 PSA-3 SN(2) F-X VT3H RHR-203 RHR-130 BOX F-X VT3H RHR-206 RHR-131 STRUT F-X VT3M RHR-206 RHR-432 SPRING F-X VT3H RHR-206 RHR-132 ANCHOR F-X VT3H RHR-206

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM. 3000 GEORGE WASHINGTON WAY P.O. BOX 968 RICHLANDt WASHINGTON 99352 2 ~ PLANT: WNP-2~ HANFORD RESERVATIONS BENTON COUNTY'A~
3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION'/A
5. COMNERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXANINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. METHOD DRAWING NO. IHF RHR-916N RIGID F-X VT3H RHR-206 RHR-55 BOX F-X VT3H RHR-206 RHR-493 SPRING F-X VT3H RHR-207 RHR-495 PSA-35 SN (2) F-X VT3H RHR-207 RHR-494 PSA-10 SNUBBER F-X VT3H RHR-207 RHR-4'96 PSA-10 SNUBBER F-X VT3H RHR-207 RHR-497 SPRING F-X VT3H RHR=207. RHR-323 SPRING F-X VT3H RHR-210 RHR-1021N PSA-3 SN (2) F-X VT3H RHR-210 RHR-322 BOX F-X VT3H RHR-210 RHR-321 SPRING F-X VT3H RHR-210 RHR-311 PSA-3 SN(2) F-X VT3H RHR-210 RHR-303 SPRING F-X VT3H RHR-210 RHR-302 STRUT F-X VT3H RHR-210 RHR-301 PSA-3 SNUBBER F-X VT3H RHR-210 RHR-304 STRUT F-X VT3H RHR-210 RHR-298 BOX/STRUT 'F-X VT3H RHR-210 RHR-3P4 STRUT F-X VT3H RHR-210 RHR-337 STRUT F-X VT3H RHR-210 RHR-338 SPRING F-X VT3H RHR-210 RHR-973N ANCHOR F-X 'T3H RHR-210 RHR-972N BOX F-X VT3H RHR-210 RHR-345 PSA-1 SN (2) F-X VT3H RHR-210 RHR-347 BOX F-X VT3H RHR-210 RHR-346 STRUT F-X VT3H RHR-21 0 RHR-348 SPRING F-X VT3H RHR-210 RHR-34'9 SPRING F-X VT3H RHR-210 RHR-2'96 SPRING F-X VT3H RHR-210 RHR-295 BOX F-X VT3H RHR-210 RHR-98 STRUT F-X VT3H RHR-210 RHR-'97 BOX F-X VT3H RHR-210 RHR-96 BOX F-X VT3H RHR-210 RHR-'95 SPRING F-X VT3H RHR-2 10

1. OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEM 3000 GEORGE WASHINGTON WAY. P.O. BOX 968, RICHLANDt WASHINGTON 99352 2 ~ PLANT'NP 2 ~ HANFORD RESERVATIONr BENTON COUNTYr WA ~

3 ~ PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A

5. COMMERCIAL SERVICE DATE: 12/13/1984 b. NATIONAL BOARD NUMBER: N/A 10+ ABSTRACT OF EXAMINATIONS. LIST OF EXANINATIONS-CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEN NO. METHOD DRAWING NO.

IV.F RHR-94 STRUT F-X VT3H RHR-210 RHR-90 BOX F-X VT3H RHR-210 RHR-91 STRUT F-X VT3H RHR-210 RHR-996N ANCHOR F-X VT3H RHR-210 RHR-318 RIGID F-X VT3H RHR-210 RHR-319 RIGID F-X VT3H RHR-210 RHR-997N ANCHOR F-X VT3H RHR-210 RHR-320 SPRING F-X VT3H RHR-210 RHR-'905N STRUT F-X VT3H RHR-211 RHR-900N STRUT F-X VT3H RHR-211 RHR-47 STRUT F-X VT3H RHR-211 RHR-46 BOX F-X VT3H RHR-211 RHR-966N ANCHOR F-X VT3H RHR-211 RHR-41 BOX F-X VT3H RHR-211 RHR-139 SPRING F-X VT3H RHR-21 1 RHR-40 STRUT F-X VT3H RHR-211 RHR-39 PSA-3 SN(2) F-X VT3H RHR-211 RHR-35 SPRING F-X VT3H RHR-211 RHR-37 BOX F-X VT3H RHR-211 RHR-51 STRUT F-X VT3H RHR-211 RMR-50 PSA-3 SNB/STRUT F-X VT3H RHR-211 RHR-42 PSA-3 SNUBBER F-X VT3H RHR-211 RHR-43 SPRING F-X VT3H RHR-211 RHR-395 SPRING F-X VT3H RHR-212 RHR-391 ANCHOR F-X VT3H RHR-212 RHR-392 BOX F-X VT3H RHR-212 RHR-393 BOX F-X VT3H RHR-212 CO RHR-394 SPRING F-X VT3H RHR-212 h3 RHR-954N PSA-1 SN (2) F-X VT3H RHR-216 RHR-940N PSA-3 SN (2) F-X VT3H RHR-224 0 RHR-'95'9N PSA-3 SN (2) F-X VT3H RHR-224 RHR-934N SPRING F-X VT3H RHR-224 RHR-987N RIGID F-X VT3H RHR-232

1 OWNER WASHINGTON PUBLIC POWER SUPPLY SYSTEM ~ 3000 GEORGE WASHINGTON WAY r P ~ 0 ~ BOX 968 r 3. RICHLAND r WASHINGTON 99352 PLANT UNIT: WNP-2 2 ~ PLANT 'NP 2 r HANFORD RESERVATION r BENTON COUNTY r WA ~

4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMNERCIAL SERVICE DATE: 12/1'3/1984 b. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCR I PTI ON I TEN NO. NETHOD DRAWING NO. NS-SA-4 STRUT F-X VT3H NS-101 NS-HA-2 SPRING (2) F-X VT3H NS-101 NS-HB-1 SPRING (2) F-X VT3H MS-102 NS-SB-7 RIGID S TRUT F-X VT3H NS-102 MS-SD-4 STRUT F-X VT3H NS-104 NS-HD-2 SPRING (2) F-X VT3H MS-104 MS-SD-1 STRUT F-X VT3H MS-104 MS-SD-2 STRUT F-X VT3H NS-104 NS-2619-16 STRUT F-X VT3H MS-106 MS-261'9-17 SPRING F-X VT3H MS-106 MS-2619-21 STRUT F-X VT3H NS-106 NS-2619-211 SPRING F-X VT3H NS-106 MS-261'9-22 RIGID F-X VT3H MS-106 MS-2619-24 RIGID F-X VT3H NS-106 NS-137 SPRING F-X VT3H MS-201 NS-123 STRUT F-X VT3H MS-201 MS-121 SPRING (2) F-X VT3H MS-201 NS-120 SPRING (2) F-X VT3H MS-201 MS-119 STRUT F-X VT3H MS-201 MS-118 STRUT F-X VT3H MS-201 NS-115 SPRING (2) F-X VT3H MS-201 MS-103 BOX F-X VT3H NS-201 MS-101 SPRING (2) F-X VT3H NS-201 NS-100 STRUT F-X VT3H NS-201 MS-992N BOX F-X VT3H NS-201 MS-98 STRUT F-X VT3H NS-201 MS-'97 SPRING (2) F-X VT3H NS-201 MS-139 SPRING F-X VT3H MS-201 MS-140 STRUT F-X VT3H MS-201 MS-94 BOX F-X VT3H MS-201 MS-95 STRUT F-X VT3H MS-201 MS-96 PSA-10 SN(2) F-X VT3H NS-201 MS-93 SPRING (2) F-X VT3H NS-201

1 OWNER'ASHINGTON PUBLIC POWER SUPPLY SYSTEM r 3000 GEORGE WASHINGTON WAY P 0 ~ BOX 968> ~ RICHLAND'ASHINGTON 9'9352 2. PLANT: WNP-2t HANFORD RESERVATIONt BENTON COUNTYt WA ~

3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/1984 b. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS LIST OF EXAMINATIONS-'ODE CATEGORY IDENTIFICATION NO. DESCRIPTION. ITEM NO. METHOD DRAWING NO.

MS-924N SPRING F-X VT3H MS-201 MS-91 PSA-3 SN(2) F-X VT3H MS-201 MS-174 PSA-35 SNUBBER F-X VT3H" MS-202 MS-173 SPRING F-X VT3H MS-202 MS-171 SPRING F-X VT3H MS-202 MS-997N STRUT F-X VT3H MS-202 MS-998N PSA-10 SN (2) F-X VT3H MS-202 MS-170 SPRING (2) F-X VT3H MS-202 MS-168 STRUT F-X VT3H MS-202 MS-167 PSA-10 SN (2) F-X VT3H MS-202 MS-996N PSA-10 SN (2) F-X VT3H MS-202 MS-163 SPRING (2) F-X VT3H MS-20Z MS-160 STRUT F-X VT3H MS-ZOZ MS-162 PSA-10 SN(2) F-X VT3H MS-202 MS-157 STRUT F-X VT3H MS-202 MS-154 RIGID F-X VT3H MS-202 MS-177 PSA-3 SN(2) F-X VT3H MS-202 MS-147 PSA-35 SN(2) F-X VT3H MS-202 MS-148 PSA-10 SNUBBER F-X VT3H MS-202 MS-145 PSA-10 SNUBBER F-X VT3H MS-202 MS-'921N STRUT F-X VT3H MS-203 MS-38 PSA-10 SN (2) F-X VT3H MS-203 MS-37 SPRING (2) F-X VT3H MS-203 MS-1001N PSA-35 SNUBBER F-X VT3H MS-203 MS-36 STRUT F-X VT3H MS-203 MS-1000N STRUT F-X VT3H MS-203 MS-34 STRUT F-X VT3H MS-203 MS-33 SPRING (2) F-X VT3H MS-203 MS-999N PSA-10 SNUBBER F-X VT3H MS-203 MS-48 PS*-3 SNUBBER F-X VT3H MS-203 MS-994N BOX F-X VT3H MS-203 MS-27 q PSA-10 SN (2) F-X VT3H MS-203 MS-26 STRUT F-X VT3H MS-203

1 ~ OWNER: WASHINGTON PUBLIC POWER SUPPLY SYSTEMS 3000 GEORGE WASHINGTON WAYi PION BOX 968 WASHINGTON 9'9352 Z PLANT'NP 2t HANFORD RESERVATIONr BENTON COUNTY'A 'ICHLANDt

3. PLANT UNIT: WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION: N/A
5. COMMERCIAL SERVICE DATE: 12/13/1984 6. NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPTION ITEM NO. METHOD DRAWING NO. MS-63 SPRING (2) F-X VT3H MS-204 MS-906N STRUT (2 ) F-X VT3H MS-204 MS-62 SPRING (2) F-X VT3H MS-204 MS-61 STRUT F-X VT3H MS-204 MS-1009N RIGID F-X VT3H MS-204 MS-59 STRUT F-X VT3H MS'-204 MS-57 STRUT F-X VT3H MS=204 MS-53 STRUT F-X VT3H MS-204 MS-54 STRUT F-X VT3H MS-Z04 MS-51 SPRING (2) F-X VT3H MS-204 MS-1005N PSA-35 SNUBBER F-X VT3H MS-204 MS-50 SPRING F-X VT3H MS-204 RFW-164 STRUT F-X VT3H RFW-10Z RRC-SA-65 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-7 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-15 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-8 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-'9 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-17 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-SA-18 PSA-35 SNUBBER F-X VT3H RRC-101 RRC-HB-7 SPRING F-X VT3H RRC-102 RRC-HB-9 SPRING F-X VT3H RRC-102 RRC-SB-13 PSA-35 SNUBBER F-X VT3H RRC-102 RRC-SB-11 PSA-35 SNUBBER F-X VT3H RRC-102 RRC-HB-8 SPRING F-X VT3H RRC-102 RRC-SB-14 PSA'-35 SNUBBER'N F-X VT3H RRC-102 RHR-SA-30 PSA-10 (2) F-X VT3H RRC-106 RHR-SA-31 PSA-10 SNUBBER F-X VT3H RRC-106 RRC-9 SPRING F-X VT3H RRC-106 RRC-6 SPRING F-X VT3H RRC-109 RRC-1C-6PS STRUT F-X VT3H RRC-109 RRC-4470-31 PSA-1 S NUBBER F-X VT3H RRC-ill RWCU-1C-17 PSA-1 S N(2) F-X VT3H RWCU-101

1 ~ OWNER ~ 'WASHINGTON PUBLIC POWER SUPPLY SYSTEl1 ~ 3000 GEORGE WASHINGTON WAY t P 0 BOX 968

                                                                                         ~   ~    ~

RICHLAND'ASHINGTON 99352 Z PLANT WNP Zr HANFORD RESERVATIONS BENTON COUNTY'A

                                          ~                                                         ~
3. PLANT UNIT: 'WNP-2 4. OWNER CERTIFICATE OF AUTHORIZATION'/A 5 ~ CONt1ERCI AL SERVICE DATE: 12/13/1'984 6 ~ NATIONAL BOARD NUMBER: N/A
10. ABSTRACT OF EXAMINATIONS. LIST OF EXAMINATIONS:

CODE CATEGORY IDENTIFICATION NO. DESCRIPT I ON ITEN METHOD DRAWING NO. RWCU-144 SPRING F-X VT3H RWCU-101 RWCU-143 SPRING F-X VT3H RWCU-101 RWCU-146 SPRING F-X VT3H RWCU-101 RWCU-1C-7PS STRUT F-X VT3H RWCU-101 RMCU-145 SPRING F-X VT3H RWCU-101 RMCU-1C-7 PSA-3 SNUBBER F-X VT3H RWCU-101 RMCU-1C-6 PSA-3 SNUBBER F-X VT3H RWCU-101 RMCU-1 C-8 PSA-3 SNUBBER F-X VT3H RWCU-101 RMCU-1C-5PS STRUT F-X VT3H RWCU-101 RWCU-1C-5 PSA-P SNUBBER F-X VT3H RMCU-101 RWCU-1C-3PS STRUT F-X VT3H RWCU-101 RWCU-1C-1 STRUT F-X VT3H RWCU-101 RWCU-'927N PSA-3 SNUBBER F-X VT3H RWCU-301 RWCU-928N PSA-10 SNUBBER F-X VT3H RWCU-301 SM-938N BOX F-X VT3H SW-303 SM-936N BOX F-X. VT3H SW-303 SW RING HDR B (CS) RING HDR SUPPT F-X VT3H SW-303 SW-920N BOX F-X VT3H SW-307 FPC-243 BOX F-X VT3H FPC-305 FPC-244 BOX F-X VT3H FPC-305 FPC-245 BOX F-X VT3H FPC-305 FPC-246 BOX F-X VT3H FPC-305 FPC-247 BOX F-X VT3H FPC-305 FPC-248 BOX F-X VT3H FPC-305 MS-272 SPRING F-X VT3H l1 S-303 HS-273 SPRING F-X VT3H NS-303 NS-274 SPRING F-X VT3H NS-303 MS-275 SPRING F-X VT3H HS-303 HSRV-3A-7PS RIGID F-X VT3H AS-303 NSRV-4B-5 R I G ID STRUT F-X VT3H NS-308 NSRV-4B-7 RIGID STRUT F-X VT3H NS-308 0

ISI

SUMMARY

REPORT RF93A APPENDIX B This appendix summarizes the ISI results for refueling outage RF93A. This outage is identified as R8 in this summary. The following notes in the REMARKS column apply: 1 This weld did not receive full UT coverage from both sides. It did receive full coverage from one side and meets ASME Section XI coverage requirements. 2 This examination did not meet full ASME Section XI coverage requirements.

~.

   ~                           ~

~r.'P - l'r" "ASHINGTON PUBLIC SUPPLY SYSTE)( (AT(.RV>L: ~l NON-DESTRUCTIVE EXAHI ION SUNNARY TABLE PAGE 00 l FPII l): SYSTEM OR COHPONENT RRC(g)-4S DATE A(3/20/93 !.'UTA l:E: i(f! DES CR IPTI ON: RQJACTg R R ECQR LOQP 8 l RA-,1ilJ('> 'Ji". PRC-10~ EX Af'l ~ DA'l 4 AQQNAT~Q R ES JU

                                                                                                        - TS                          EMBARKS F  ',( i'L',1
                                                          ~  SH(   F. T    l'JO       . I N S I GN'I F        S I G N I F I CANT l bL liT        e
                    'J "r ~                 "~ Tll~          NO  ~         INDI C ~      INDIC~     ~  'EONETRY            OTHER    R RP   C-Sh- l!,( ')         ~

1RRP-130 ACC NO RECORDABLE INDICATIONS 24 l'!? l ( ' ' s . 4 il ', C ( l'. ) " 4 ." Vl)L '"P0-106 45 e60 NO RECORDABLE INDICATIONS SCAN LINITED ONE SIDE DUE TO S WEEP OLET CONFI G ~ SEE NOTE 1 I RAP-123 ACC NO RECORDABLE INDICATIONS 4RRC(<,) "~3-1 V '-l. (-R8-107 45 y60 NO R E COR 0 ABLE INDI CAT IONS SCAN LI)5ITEO ONE SIDE DUF TO SWEEPOLET CONFI G ~ SEE NOTE 1 SUw I R RP -123 4C C NO RECORDABLE INDI CAT10NS 4 l(R C ( ';3 )  ? l) ". R-RB-108 45>60 NO RECORDABLE INDICATIONS SCAN LINITED ONE SIDE DUE TO FLANGE CONFI G ~ SEE NOTE 1 SUR 1%lip-173 ACC NO RECORDABLE. INDI CAT IONS "4(l v C (.") <3-P/ 4P RC ( 4) -4" VOL 8-RB-109 45 q60 NO RECORDABLE I NOI CAT IONS S CA NgL-I:H$.7EP. ONE SIDE DUE TO S WE Eg,OL'E'7~~4'O.N FI G ~ SEE NOTE 1 S UR 1R RP" 123 AC C NO R(COB'QJItSLE INDI CAT IONS c 4 l! l' ( 2) B- 9 VOL R-RB-110 454qfi0 NO REQ .(A/LE INDI CAT TONS

  ?4Rf      C (      )  B-9LDO VOL             R-R8 "10.5     45                                                       NO RE,'GO/SABLE
                                                                                                                                            ':(I ",-

I NDI CAT IONS

V@V-na MASHI NGTON PUBLIC POWER SUPPLY SYSTEf( INTL'RV AL: (iI E f? I nD: () . SYSTEM;..OR";~('jCt)5~4IlIENT f NON-DESTRUCTI) E1lAHINATI ON SUHNAR Y TABLE RRC (2)-4S DATE PAGE 002 08/20/93 ciUT A GE: DESCRIPTIOH'; REACTOR RECIR LOOP I iR A W I f'I 6 r? )3

                     '4 0  ~   " '? C -1 0
                                                                   '- '-'.-".'"::                                         B r XAg ~                           Z':.-:.'X~AH DATA                   N~A~IQ~E~TS
                                         'hH  ~ ~>3 "ET        MO   ."""",".'-I NS I'GH:XF                   SIGNIFICANT I f)f  ii T,. ) 3.                           NO  ~                       ."

JHQM 'NDLR 2iiR f C ( ) 1~-'I "I VOL R -Rf3 -1 04 45 NO RECORDABLE INDICATIONS i" ii R P C (

                   " ) '3 "  1 ) LU n VnL    R -R8-1   01   45                                                           NO RECORDABLE         INDICATIONS 2'ii? I'C (        )!3- I    1 f  J I                                                          ."'nL R-R8-102       45                                                           NO RECORDABLE         INDICATIONS
  ".48 RC        (   )  "-1!i PC(                            VOL    R-R8-127                       45y60                                        R OOT AND ID GEO MET R Y NO SCAN PUMP SIDE DUE TO            CONFIG ~

S EE NOTE 1 2iif'RC (1) '.3-11 R-R8-123 45 F60 NO RECORDABLE INOICAITONS NO SCAN PUMP SIDE DUE TO CONFI G ~ SEE NOTE 1 2iiP I ) (I- I I Lf) V Af R-R8-12ii 45 NO RECORDABLE INDICATIONS 41?f. r. (i'.)1I:-1 Vn. R-RB-121 45 s60 NO RECORDABLE INDICATIONS SCAN L IN I TED ONE .S IDE DUE TO S4EEPOLET CONFIG ~ SEE NOTE 1 SUi? 1RRP-128 ACC NO;, 'OROAQLE INDICATIONS

  <>                                                           DESCRIPT.I',QN g",~~R'TOR   R ECgR L,QQP R UIe ri I J  l N! (>    I~   ~
                              " i'. (: -I n ."

EXr,M. DATA EX AHQNAT~Q ~R~-TS iH'T NO INSIGN'IF; SIGNIF I CANT It)f !JT .. <). >'40 i INDI C INDICT". GE'OMETRY OTHER REMARKS Iei(C-I!i.r VT >"I 1HV-()254 ACC SPRING CAN DAMAGED AT CONTACT WITH CLAMP ~ EVALUATED AS ACCEPTABLE ~ SPRING IS TO OE Iil CONTACT WITH CLAMP WHFN COLD

  ," 4 'e I! C ( I    I I{ -!: / I >" i( i,   C r
                                                   '  - 'i R-R8-1(ib
                                                              "'!'L 4".i s60                                        NO RECORDABLE                 INDI CAT IONS SCAN       LIHiITED          ONE  SIDE DUE    TO SWEEPOLET CONFIG ~ SEE NOTE 1

I RRP-119 ACC NO RECORDABLE INDICATIONS I 6P >C ( I )!<- I Y (iL R-RB-159 45t60 R OOT AND ID GEOMET RY NO SCAN UPSTREAM DUE TO CROSS CONFIG ~ SEE NOTE 1 RRC -III{-'i V T.iH 1HY-0246 ACC NO RECORDABLE INDICATIONS I6 R PC i ! ) I' I / 1 2 i!R C ( I ) - I'I.". G V OL R -R8-1.i'i 45 e60 NO RECORDABLE INDICATIONS SUB 1RRP-126 ACC NO RECORDABLE I NDI CAT IONS I'RC -5'i-I  % q4 . , qi

                                                                                                                                                    >~i{
                                                                                                                                                         ..{g VT 'il                  I lk V-0246   ACC                                             NO g! (O,g,bA'ALE             I NDI CAT IONS

{ele C-SB-11 VTPI 1HV-0246 ACC NO R .C5R.DA LE I NDI CAT IONS I 6 Ie R C ( I ) 0 - I / I 2 R R C (! ) - N 'i I VOL R-RB-155 45q60 No RK>{'3I((/LE I NDI CAT IONS SUR IRRP-127 ACC NO RK,CORDABLE INDICATIONS

                                                                                                                                        '; 4 449~:,"-,y

WNP- 0? WASHINGTON PUBLIC POWER SUPPLY SYSTEH 1iVTF. RV AL: 0 1 NON" DESTROY IV E='EX'$HIN AT I ON SUMH AR Y T ABL E PAGE 000 f'f R1 (if): 03 SYSTE)."Off,'.~Cd)P Qgf NT RRC (2 )-OS DAT E 0 8/20/93 (iUTA( C: Rii. DES CRZ J',,TI OH'".~JTg R R EC J R ~QP g f)f(AI' N(i ~ ~RC-l Oi r';r r

                                                     ~XAH ~

DATA f'X AHJ~MIIIQ,Q~E E)'H SHEE,T iVO,....'INSI GNXF: SIGNIFICANT I 1) f fi T ~

                 'c'i 0~              i~
                                         $ 'I ~                     LHglg~       '-~XHDI~          QKRHKIEX, OZHKE     R~fARQS R RC    -iIfI-ip V  T3ii        1HV 0206       ACC                                                NO RECORDABLE      INDICATIONS 1 6R RC     ( 1  )   i) -.'   1 2 RR C (  1  ) -N?. J VilL           R-RB-131       i)5 i 60                                           NO RECORDABLE      INDICATIONS SU~            1RRP   -125    ACC                                                NO RECORDABLE. INDI CAT IONS HP(       4 i    1I)

V f.">H 1HV-O?.96 NO RECORDABLE INDI CAT IONS 1 f I> N'C (1) ii-3/ 12'-8 C (1) -M2K VOL R-RP.-132 05 q60 NO RECORDABLE INDICATIONS 1R RP -1? 7 AC C NO RE CORDABLE I NOI CAT IONS 1 2R RC ( 1 ) -.'4': " -1 VOL '(-R8-135 45y60 R OOT AND ID GEOHETRY 1?i'PC ( 1) -i~? H-1LD V ('L R -RB -122 05 NO RECORDABLE INDICATIONS RRC-PB-10?(L) V T-2 1 VT2-93 ACC NO RECORDABLE INDICATIONS j+ r~g~ c r

   ~                 ~

(:rJI'- 0 ~ MASHI NGTON PUOL IC SUPPLY S YSTEM )NTf.OVAL: '3l riOt)-DESTRUCTIVE EX)MI ION

SUMMARY

tABLE PAGE 00 I'L'f< l (>fl: SYSTEM OR COMPONENT RRC-P "gA OAT E 0 8/P0/95 ( U)A(,C. DES CRIPTI ON:

  • RRC': Qg()P A PUMP f.'. A ff T N (p fA ~ i "C ~
                                                                     > i g~
                                   '.X AM ~

Dn>A i> I T'!.

                                 ~ SH:".LT       NO         INSI  GNIP,'I GNIF I         C AN T IDf. Nl       y(>.      ~        Ni P          INDI C ~   INDICT "f". GEOMETRY OTKER            R LNAR f(S HRC-P(3-) 0 ((i       )

V (-2 1 V T2-9h ACC NO RECORDABLE INDI CAT IONS EXAM AREA IS COVERED ON DRAMINGS RRC-101 AND RRC-102

VlJf'- 9 ~ WASHINGTON PUBLIC POWER SUPPLY SYSTEH INTLt'V<I: 0 I NON-DESTRUCT I V E,gE)tJHI N AT I ON SUHH AR Y T ABL E PAGE 001 PERI <'D: SYSTEH: OR:"CO/FQN/NT RRC(51) -4 DAT E 08/20/93 OUTA ('.: ~<!i D ES'C R I P.TI ON ~ ft P.0," D R A I N DRAW IMG 'yO.::-'C-] O~i EXAH ~ DATA EXAH~N~ION'~J QS A I~J ~ SHEET IDE A,T ..') J ~ Tf> ~ RRC-PB-5 04 (L ) V T-3 1 V T2-93 AC C NO RECORDABLE INDICATIONS c

  • W'gJ =
                                                                                                              ~ '. ~
                                                                                                                     ~

t t4f'-{t2 'ASH1NGTOM PUBLIC . SUPPLY SYSTEH lr(TL VVAf.: t l  !)ON-DESTRUCT I VE EXAHI 1ON SUHH AR Y T AHl l. PAGE on ! f fr 1 S YST Eltl OR CONPONENT RRC ( 6 ) -rf S DATE 08/20/93 Al')'tU1hrtl: DESCRIPTION gHR SHUT ON COOL SUCT l f;hf. lf;(. X.r . PRC f, )( hff ~ DATA t )(;,y ~ SHEET NO .- I NSI GNIF S I GNI F I C ANT 1UL r)T .. c(t. e"i T'f ~ fig ~ INDI C . 'NDIC ~ POR R C (.,) -t. VOL R-R8-111 t'f5 e60 if 5 ANO 60 RL RECORDED ONE PLANAR 1 NDI C AT I ON ~ L EN GTH 3~6 THRU WALL OIN = 17 5X ~ ACCEPTABLE FOR ONE OPERATING CYLCE PER ANALYSIS DONE AT R6 ~ Rf(C-f f'- l t)" { I ) V T-2 l V T2-93 ACC NO RECORDABLE INDICATIONS pPcj ~~i.( gg1 ~

                                                                                                                               <<VS     W ~

a'Affx- f> 2 WASHINGTON PUBLIC POWER SUPPLY SYSTEM I NTERV AL: 0 l NON-DESTRUCT'IYE <<EXAHINATION SU)<<f8ARY TABLE PAGE 001 f fRTOO: 04 SYSTEN; OR COHPOhtkNT RQC(7) 4S DATE 08/20/93 OUTAGE: x l: DES CRII.'TION.,;-Sx 0: DN COOL RETURN A f>R AV I N 0 .'! 0 '. R C - l f> 6 EXAHQ<<<<+EON '~RESQ ' NO';,- '. ~INSI,GNIF;". S IGNI F IC ANT I DENT ~ .'iO. f<<.IIR -$ A-.t 0 V T ~H 1HV-0246 ACC NO RECORDABLE INDICATIONS R flR -$ A-', 1 V T3)l 1HY-0246 ACC NO RECORDABLE INDICATIONS RRC-9 VT '<<H 1H Y-0246 ACC NO RECORDABLE INDICATIONS P RC-f'R-I Ot<<< L ) VT-2 1V T2-93 ACC NO RECORDABLE INDICATIONS

f Nl'- li> 'WASHINGTON PUBLIC SUPPLY SYSTEH l<l TT f'VAL: '< l Ofl-DESTRUCT I YET EXAHI T ION SUHH ARY 1 ABLE PAGE 00 l l H10" S YST EH ~ OR COHP ONENT RRC (g) ->>S DATE 08/20/93 fiU T h l< l.: I AC l". ~ '. f' " 1!} 7

                   !.'<RAMI
f. X AH. <*

DA1A ~E<<Ri.ggg~IQ ~RESU:IS E. )'".) ~ SHf ET NO ~;" ~"I'NSIGMI'F SIGNIFICANT TDE hT i 4'i e ~ R! Tkf ~ NO ~ INOI'C ~ ' INO'ICi -= GEOHETRY OT TIER R SHARKS 1 f(RC( 7) i5- L".1 VOl f(-R8-116 45 NO RECORDABLE INDICATIONS 1RRP -1?>> ACC NO RECORDABLE INDICATIONS 1?RPC( E) 8" 2Li'li Vf;L f(- RB-11'z 45 NO RE CORT)ABLE I NDI CAT IONS iUh, 1R RP -124 AC C NO RECORDABLE INDI CAT IONS 1? F 'f C ( 7 ) "- ': L 1 f 1 VOL R-R8-117 45 NO RECORDABLE INDICATIONS

                                       > UP.      1RRP    -124   AC C                                         NO RECORDABLE    INDICATIONS 1."l;1'C (     f) fl- 'LUO VOL        R  - f(8-118   45                                           NO RECORDABLE    INDICATIONS I ff R~~-124   ACC                                          NO RECORDABLE    INDICATIONS 1". fig ( I) fg- c VOL        P-P8-1?0                                                    NO RECORDABLE    INDICATIONS 1RRF-12>>      ACC                                          NO RE CORDABLE   I NOI CAT IONS 1?Pl'C     f 1)      6-3L D VOL       P.-P,8-119     45                                           NO RANCORD.A)LE I NDI CAT IONS SUf(        1RRF-124      ACC                                          NO  R+OROABLE I NOI CAT I 0NS RRC-s      P-107(L)

V T-? 1 V T2-93 ACC NO RE:GORPPbLE I NDI CATIONS

                                                                                                                       ' 'ff"

r.ref'- nr WASHINGTON PUBLIC POWER SUPPLY SYSTEllf FNTETrVAL: 0l NON-DESTRUCTIVE =EXANINATI ON SU~H AR Y T AaL E PAGE 001 I'r F l OD: rr I S YST.EN 'OR';fCOHP,9'4ENT, RRC (4 ) -4S DATE 08/20/93 rIU I A rA F; H' DESCR,APT'IU/IH".,IQ~@Q JQTERTJQ RRC A r:R nw I rl!:.:.> O. '".~i-10>! EX ANl ~ DATA ERAHJN$'j~llg: " S F .">>F' SHE'E T NO!.A;:",.~[INSESN F: SIGNIFICANT I DE r;T ..:io. HTII ran. $$ ~02 '"IN/}IM~ ': G~EH EQR~ IIT HER SETIARSS Fr RC - P B" l '3 '< ( L > V T-2 1 VT2-93 ACC NO RECORDABLE INDICATIONS

'. llP- 02 PASk(I NGTON PUBLIC ', SUPPLY S YST EH I HTEqV I L. 'T1 NON-OES TRUCTI VE EXAHI I ON SUHH AR Y TABL F PAGE 0

r. f. R 1!) D .,'

SYSTEH OR COHPONENT RRC(4)-4S OAT E 08/20/93 ('U)A+F: "f( 0 ESSCRIPTION RWCU INTERTIE RRC 0 1' A! I 1 hl (. 'A ".l ~ R! < C 1, 'J " r

                                                    'A<)      ~

f) A T A ERAS/NATION ~RESll TS Jr'<c!T ~ ~ 4f'<<C ( 4 ) - -4

                                             )T .)y Sv, r.F. T
l() ~

NO INDI C ~ i/DIG~ ', INSI GNIF; S I GNI F I C ANT GEOHETRY OTHER R EHARQS VOL R-f10 "12fi 45 NO RECORDABLE INDICATIONS 4P~. (4 ) VOL R-RR-129 45 NO RECORDABLE I Nf)I CAT IONS

  <<f(C -(',

V f "~ 11(V-0246 ACC NO Rf COROABLE INDICATIONS 4R(((4TT1-) V l'L R- Rf<-126 NO RECORDABLE INDI CAT IONS SU!P 1RRP -129 AC C NO RECORDABLE INDICATIONS fAf(/' C: E)-. VT..T( 1Ãv-024( ACC NO RECORDABLE INDICATIONS VrL ". -R k) -130 4'5 NO RECORDABLE INDICATIONS 4RRC(<<))-1'RC-V!.-1C~(L) 1RRP "129 ACC NO PECOROABLE I NDI CAT IONS V T-2 1V T2-93 YACC NO RECORDABLE INDICATIONS A

I'hJV- (Ig WASHINGTON PUBLIC POLJER SUPPLY SYSTEM 1'INTERVAL: '!1 NON-DESTRUCTIVE-EXAMINATI ON SUMM AR Y T ABL L PAGE 001 l'ER I OD: 0 5 S YS'T Pl '$ COHP~54ENT RRCgQg-4 S DATE 08/20/93 OUTAGE DESCRIPTION:,:RRCiLOOP A DRAIN R A4 1

          ')

N G .4 0 ~ i? 0C -1 1 t) EX API. OA TLA E '; S i'X~AX'iijjffjN'.: E!( 0M ~ SHEET NO-=;;~;:~.:,'-I:NSX g IF'" S I GN IF I C AN T 1DE I!T ~ . XO ~ itA TH ~ NO ~ ~gpss~ QQQ+~'~EQQTRY /THER R~EARQS RRC -l't'-1 10 < L ) Y 1-2 1V T2-9b AC C NO RECORDABLE INDICATIONS

~N f>- fl i> WASHINGTON PUBL IC SUPPLY SYSTEM

   >'7 f !.V AL.                                                    N" DESTRUCTIVE EXAHI       ION 

SUMMARY

TABLE PAGE 0 1

     I 0[)

E' "JO SYSTEH,OR COHPOQENT RRC (6 )-0S> DATE n8/2O/93

              ')UTAGf:

8P. DESCRIPTION: ~RRC'LOOP B DRAIN D ll A W I f J G ~i ) ~  !'. C - I )

                                                                                     'lg 'Yk>

t )! A'A. DATA EXAR1MA'TIRE ~RESU TS

                                           ~  V~V  Sf<<:f. T        NO   < '.:- INSIgNIF       SIGNIFICANT 10f   NT   ..'JO.                       rg Tss  NO   ~           INDI~ - IQDLQe ~'i'fOMf TRY QTHER           REMARKS RR C  -Q A 7')         -3   T V  T.cH i H V-02'! 6     ACC                                         NO RECORDABLE INDICATIONS H!) C-PE'-1            I I (L   )

V T 1V T2-9b ACC NO RECORDABLE INDICATIONS

gfyP ri 2 WASHI NGTON P UBL IC POWER SUPPLY S YST EN INICRVAL: 01 NO N- DES TRUCT I V E EQAHI N AT I ON SUNM AR Y TABLE PAGE 001 f'f R I Of): sf '5 SYSTEHTOR .COMPONENT RWCUCQ) -4 DAT E 0 8/20/93 ()UTA('t.: .(if OEGCRIRTTION".'.~IT,".JR~AN TQ RNgU 11PAW JNG;r,.') R I( U I (I J CX Aflf ~ DATA E itJ.g'aIijg '~C'+ E 7,>>f.f ~ SH f.C T NO '-, .E", ~(l;". 'NS,I'Gl'I.F'IGNIFICANT IL)CNI- VO. fsf 1 fin 30 ~ INO[C'-'SS~OCiC"..':I GEOHETRY OTHER R EHARQS RI.'CU-JC-1"I V I ~H 1HV" 0246 ACC NO RECORDABLE INDICATIONS RWCU-14'I V T.'.H 1H V-0246 AC C NO RECORDABLE INDICATIONS RMCU-14~ V T'sff 1HV-0246 ACC NO R E CORDABLE INDI CAT IONS

41. W CU ( .'.) - I l:is VT-1 1RTV-007 ACC SPOTS OF MINOR CORROSION ON STUDS ~

NO APPARENT fIATERI AL LOSS l(WCU-] 'si V . '>sf 1HV-0246 ACC NO RECORDABLE INDICATIONS ff W C U- V - 1 C fs - iJ L T VT-1 1RTV-006 ACC MINOR CORROSION ON STUDS BETWECN FLANGCS ~ NO APPARENT NATERIAL LOSS 4 P wCU (,' - 1 I)I I( Ls Y T-1 1R TV-005 ACC HINOR CORROSION ON STUDS BETWEEN FLANGCS ~ NO APP ARENT HATER I AL LOSS R 1-.'CU-] C- Yf".> T 74 1HY-0246 ACC NO RECORDABLE INDICATIONS RWCU- 1 4'I Y 1.'ift 1HV-0246 ACC NO RECORDABLE I NDI CAT I ONS RWCff-I ( -'f V T;$ H 1HY-024E ACC NO.:R g5;PP E INDICATIONS PWCU-1'6 V T.5)1 1HV- IJ246 AC C NO R4(JQ't)Ak 'E INDI CAT IONS P.g('sJ I C .Jg A<pf'f'.., VT~H 1HV-0246>>CC NO'$08 Bt,:,E I NDI CAT IONS P WCU-1C-BPS V TRI( 1HV-0246 ACC NO RM "E I NDI CAT IONS

i klP l)Q WASHINGTON PUBLIC R SUPPLY SYSTEH fN Tf'RV AL. <> i !40 N-DESTRUCTIVE EXAH ION SUHH AR Y TABLE PAGE 0 l f'l 1 nD: SYSTEHi OR .COHP'ONENT RWCU(0)-4 DATE 08/20/93 r>U T 4 ('f: DESCRIPTION . RPV DRAIN TQ RMCU f)R t W f lb! .'i -'.l ~ .. ~ C '.r - 1:.I l f XAH ~ DATA EX AHQQ~~IQ~R~S' f'i"~ ~ SHEL' NO .. INSI GNIF," SIGN IF IC ANT IDENT ~ . '0 ~ i~1 'f l i ~ vn. PWiCli 1 r VT<H illV-024 lp ACC NO RECORDABLE INDICATIONS PVCU-lr:- ~f ". V r.'ll 1HV-0206 ACC NO RECORDABLE INDICATIONS RWCl'-1 C- 1 VT <H 1ll V-02~~ ACC NO RECORDABLE INDI CAT IONS r'RWCl.l ( ' -, 0 V Of. 1RTU-0 .6 45 hlO RECORDABLE INDI CAT TONS NO EXAH VALVE SIDE ~ SEE NOTE 1 CiRVCU l '  ;>1 V l>I fRTU-031 0-180 DEG 80X DAC ID GEO RWCU r ~) -'i2 1% TU-035 45 NO RECORDABLE, INDICATIONS rf CUr,) ;3 vnL 1RTU-021 45 NO RECORDABLE. I NDI CAT IONS r,fk,:Cul .) -; l 1lTU-022 ')5 NO RECORDABLE INDICATIONS

 ~fiwCU(          )  -r i 1 RTU "0?$       lr5                                       NO RECOROABLE  INDICATIONS 6f..V ( U  (        "2!i V liL          1R  TU-024       4b                                        NP RECORDABLE  INDICATIONS f'WC U" V-0         -BL 7 V T-1           1 RTV-00zi                 ACC                            HODERAThXIQRROS ION ON STUD S AND NUTS+i N59A)PARENT HATER I AL LOSS
 ~ WC  i>- r'f<- 1 01            < L)

VT r 1VT2 93 ACC NO R.@0$4+LE INDICATIONS

WNP-02 WASHINGTON...P UBL I$ POWER SUPPLY SYSTEM INTEPVAL: nl NON-DFSggVCXI~VI@gi+HINATION SUHH AR Y TABLE PAGE 001 PER 1 00: 03 DATE 08/20/93 OUTAGE: CA DRAWING VO, kWCU->01 gt /k' EX AN ~ DATA ~E~APQ'~ ga,

                          <XA  s ~ SHEET        NO  "'w>j:+":'llg ~ N IPgl. SIGNIF I CANT IDENT ~ ~ "tjO.           8 Thi    NO ~         I N +Dk ~'~".-""I'gQ~iwg<f GEONETRY OTHER       R EMBARKS WCU   TIRY     c Lf EK'f VOL      1R TU -025   45                                              NO RECORDABLE INDICATIONS

v't.l() 0?- WASHINGTON PUBLIC R SUPPLY SYSTEN INTCRVA )) I NO N-DESTRUCTIVE,EXAN ION SUNNAR Y TAB LE PAGE 0 l f RI ()f): ~ ) S YSTEN OR CONPONENT DESCRIPTIONS 'LWWU PUNP RWCU( 3g-4 DATE nO/20/e3 OUTA 0!:  ; )~ SUCTJ()Q l)RAW 1'oi: i ))) ~ !g!~( II- 5 0l I CX A)l e I l) f. )) I ~ ~ x') ~

                                                   ~   )'J)'I ~

itl I H ~ DATA SHf

                                                                   ~

EI'O NO INDI

                                                                                  ..;.I ExANIILAy~I g REggl.-rs C ~ ~

NSI GNIF.'l INDICT' GtJIF I CANT GEOtlETRY OTHER RENARKS () f? W) CU ( .' ,"l A SU:? 1R TP-002 ACC NO RECORDABLE INDICATIONS c) I? '~) Cl) ( .'. ) -,", ') )') U

                                                         ))

IRTV-00? ACC NO Rf CORDASLE INDICATIONS C) f' (. U ( '. ) -? ll C 5 Uf( 1RTP-002 ACC NO RECORDABLE I NDI CAT IONS C) 0 'p' u ( < ) .>f) .) 1P TP-002 ACC t]O RECORDABLE INDICATIONS R WC ll- '>." > ')) VT H 1HV-0247 ACC NO RECORDABLE I NOI CAT IONS 0 )A)( ll ).)')t)

                             )~')(?

VT 1flV-0? 47 ACC NO RECORDABLE INDICATIONS l.i(.'(! ( ' -')',C VOL 1RTU-0?6 45 NO RECORDABLE INDICATIONS C-!', l)) Cl) ( ' - '-') V')L 1R TU-027 45 NO RECORDABLE INDI CATIONS r R lu (.,i ' I A VOL 1RTU-029 4b NO RECORDABLE INDICATIONS C) I( W C 1) ( 3 ) 3 ', 1R TU-OPS 45 NO RECORDABLE I NDI CAT IONS 4 R W CU ( '5) -P A VOI 1R TU-030 45 NO RqPORf)ABLE INDICATIONS 4 f> W (.U ( 5) -3 A VOL 1R TU-031 45 NO 'tEG(!I@'ABLE I ND I C AT I 0NS 4Rll Clt (3) -4 A VOL IR IU-032 45 I NDI CAT I ONS 4VWCU( ') -5A VOL 1R TU-033 45 INDICATIONS tc ~

MNP- 07 MASH I NGTON PUBLIC POMER SUPPLY SY ST EN INTEP VAL: NON-OESITRQCTJVEI;EXAHINATION SUNN AR Y T ABL E PAGE 001 PER100: SYSIT(N,:ORE!GC5NtA f]ENT SN<~-g DATE 08/20/93 OUTA Gf: DESACftIP;T,-E ONi":,,; ':; P A SUPP LY DRAWING %0 ~ ~ ~ A F01 EX AN ~ DATA

                              'E AAN ~ SHf'4 I     NO'q',(',.'.-."'i:!,".)$S)IGPgfj,       SIGNIFICANT IOENT.. )O.                   N1)( ~   NO ~        INOJG'-'"g                  O   ':-'RR   GEOHETRY OTHER       RENARKS SW-".9 ( ':)

V T-3 1SMV-129 ACC LIGHT SURFACE RUST ~ NO APPARENT NATERIAL LOSS SM -f2 ( 'w' VT-3 ] SMV-130 ace LIGHT RUST ON SM PIPING NO APPARENT MATERIAL LOSS gT3 ( TJ) VT-3 1SMV-131 4CC LIGHT SURFACE RUST NO APPARENT MATERI AL LOSS S w'-( e ( A>) V T-3 1SMV-132 ACC HEAVY SURFACE RUST ON 'MELDED ATTACHNENTS AND SM PIPING MITH NO APPARENT NATERI AL LOSS S M- (.t- ( -:) V T-3 1S MV-133 ACC HEAVY SURFACE RUST ON MELDED ATTACHNENTS AND SM PIPING WITH NO APPARENT NATERI AL LOSS SM-11(': ) V1-3 1SMV-135 ACC HEAVY SURFACE UTERI RUAT ON MELDED ATTACHNENTS AND SM PIPING MITH NO. APPAR ENT- HATER I AL LOSS SM-173 (4 ) V T-$ 1SMV-13(o ACC SUR,- ..T,'.ON SM PI~ING METH NO:'.-'At~f". j.",RAT ER I Al LOSS SM-C8(M) V T-3 1SMV-13') ACC SURP+ QjON SM PIPING MITH NO APPI~ AL LOSS 4g

                                                                                                                   '"!""'"'(IgR j)gc ~

OP WASHINGTON PUBLIC R SUPPLY SYSTEM ]NT<<RVA ':1 "~os-DESTRUCTIVE ExaM Iow Sut(t(ARY TABLE PAGE 0 ('E t<1 OD: f} SYSTEH'R COHPONENT SM(g) -g OAT E 0 8/20/93 OUTAGE: RH DESCRIPTION:"'S'O'.LOOP A SUPPLY t}RAWlNO 's Q. r X A.'~. DATA <<xgvi NATION R~EsU 'Ts St(EC T NO,:' NSIGNIF, SIGNIF I CANT I DE NT ~ . '<i). NQ ~ INDI C o, Ig 0 I Ca>" GEON/TRY OTHER R EMARKS 0(' V T-3 1S MV-137 ACC LIGHT SURFACE RUST ON PIPE AND MELDS MI TH NQ APPARENT MATERIAL L OSS "9-73> ('a) V1 -3 1SWV-138 ACC HEAVY SURFACE RUST ON SM PIPING WIT H NO APP AREN T ll AT ERI AL LOSS 8 i'- r". 0 '} ( .t ) VT-3 1SMV-13'3 ACC HEAVY SUt(FACE RUST ON SM PIP'1NG M I TH NQ APP AR EN T 8 ATERI AL LOSS Si-4 44 ( ) VT-3 1SWV-14') ACC t(CAVY SURFACE RUST ON MELDS AND SM PIPING WITH NO APPARENT I'T ER I AL LOSS S'~-1<~<". (; ) V T-3 ] SWV-1 48 ACC SURFACE RUST QN SM PIPING MITH NO APPARENT LOSS OF HATERIAL V T 3 1 S 'v,'V 1 4 9 ACC It(IT ED TO 7 5X QF LUGS DUE TO FIRE B ARR I ER ~ SUR FACE RUST ON MELDS AND SM PIPING MI TH NO APP AR ENT LOSS OF' p >>QCif

M lg P - f.l 2 QASHI NGTON PUBLIC POMER SUPPLY SYSTEM INTERVAL: 01 NON-DESTRUCTIVE. EQUAL'NINATION

SUMMARY

TABL E PAGE 001 f'E.fl I OD: 0 ~ S Y S T, EH:; OR < C5) lit Alp,KNT S M ( 2$ ) - 2 DATE 08/20/95 ffUTAGC: PB DES GRIT,'TI ON'eiq'~Rg R HR-HX-QA l.ff a M I N',, 'f n ..= v- > 0 c EX API ~ DATA EX ARAN~-?If/,. -'. S E XAV SHEET NO'-.".-4:;.,'P- ..l NS.IGQ)F,-'; S I GNI F I C AN T 5'< TH "JO ~ ~Igggp " '""$QQ~+wi'EOHQQQQ OTHE/ QQJARQS V T <ff 1HV-0247 ACC ~ M INOR CORROS ION ON I -BE AH MER E PROTECTIVE COAT ING IS ABSENT 8 M " 9.'> i: lJ YT.':ll 1HV-0247 ACC MINOR CORROS ION ON I-BE AH MERE PROTECT I VE COAT ING IS ABSENT Skl i~" ffD<< ~S( CS f V T.'f{ 1ll V-0249 ACC CORROSION PITTING 1/2" DIA 200 NIL DEEP ~ ACCEPTABLE BY IOM SS2-PE-88-0507'ATED JUNE 2e 1988

   ~                       ~

'I 'lf'- r)2 MASHINGTON PUBLIC SUPPLY SYSTEM 1 VTf, RVAI: i'I NON-DESTRUCTIVE EX!ffHI ION SUNH AR Y T ABL E PAGE 00 f f' 1 i"ri): SYSTEN OR CONPONENT SM(37)-2 DATE 08/20/95 OUTA uf.: DESCRIPTION: ~RTURQ OCLf-HX-gAggAP UR/ \, I0(  !<. ( XAYi ~ t'X f)A TA AH I NATION RESUL'TS L aA~ ~ SRr,.t T r~O I NSI.GN IF.. S I GN I F I C AN T I UL NT ~ ~ V'> ~ Ni r'i r!0 ~ INDI C INDIC- -'EONETRY OTHER RF'MARKS 0 ~i- 5'.>i) (.i ) V T-$ 1S'~V -1 1 u AC C f'JO RECORDABLE INDI CAT IONS S(f- x>> 7 (;. ) Ul -3 1S WV-117 ACC NO RECORDABLE INDICATIONS Cpl 1C'( () VT-3 1SWV-11>i ACC NO R ECOR l)ABLE I NDI CAT IONS SM- %N'i (:q ) VT-v ],SMV-115 ACC NO RECORDABLE INDICATIONS

  ~ ir - 'i ". (;i )
              ~

VT 1 S 'f! V -1 1 4 AC C NO Rf:CORDABLE INDICATIONS C>>4(q ) V T-.S 1S'i'V-11 0 ACC NO RECORDABLE INDICATIONS LUGS RENOVED EXAM OF RENNANTS ~

~Nr -n2 WASHINGTON PUBLIC POWER SUPPLY SYSTEM ltJTCRVAL: 0] NOtJ-DE'STRUCTIVE"'EXAMINATION

SUMMARY

TABLE PAGE 001 PERI nD: 05 SYS,TEH)gk SCAMP'ANENT SW(g) -g DATE 08/20/95 AUTAGE: D SCRJPTf Oil.":. ';-. - 0 OP B SUPPLY OR A W I N 4 'Ii 0 . 5 '.J- 5 05 E X A~' ERAN ~ DATA SHEET EX'Alf +~~S NG'"xi+!INSTS41FF SIGNIFICANT I DE NI ~ ~ 'It 0 Tt< ~ NO ~ IN~DC~.-. IND~Ci ~ GEOMETRY OTHER R~EARgS SW-,"2( i) VT-.5 1S WV-150 ACC HEAVY SURFACE RUST ON LUGS AND SW PIPINC WITH NO APPARENT LOSS OF MATER IAL

'4 9 <'- 0 <? WASHINGTON PUBLIC . SUPPLY SYSTEM I NTf f'.y hf ~ i] Of'J-OESTRUCTIV.E,. EXAHI ION

SUMMARY

TABLE PAGE 00 f'f Rl OD: S YST)EH OR COPIP.'SNCNT SM( 18 )-2 DATE 08/20/93 OUTAGE: ~H 0 ES C RIP TI ON. g~>>', 'QO P 8 SUPP QY DRAW 1 lb JO ~ S '~ S'->b X A)1 ~ f

                                     >.1 XtN ~

T< ~ DATA SHEf. T ro. CXAXgjP~~rj NO>>" '- ~,",I RE~(."-'VS N S.I G N'4 F SIGNIFICANT SQ-.40f) ( ) SW - ('. ) VT-~ ] SMV -128 ACC NO RECORDABLE INDICATIONS VT-c ]SWV-127 ACC NO RECORDABLE INDICATIONS SV-.".b< ( ~ ) VT-4 ]SWV-12b ACC NO RECORDABLE INDICATIONS SW- r,J( I SWV-]25 ~CC NO RECORf)ABLE INDI CAT IONS V]-' ]Shy-]2v ACC NO R E COR 1) ABLE INDICATIONS l W ac)P(, ) I c ]SWV-125 ACC NO RECORDABLE INDICATIONS S) --" ~

               ) (>')

V r-.. 1S 4'V -122 ACC NO RECORDABLE INDI CATIONS

  -0           ()  )

Y'T-;5 ] SWV-121 ACC NO RECORDABLE INDI CAT'IONS St>> >.0P(, ) VT-;5 ]SWV-119 ACC NO RECORDABLE. I NDI CAT IONS a'4:- '] >( ) VT-~ ]SWV-]20 ACC NO RECORDABLE INDICATIONS

WNP- 02 WASHINGTON PUBLIC POWER SUPPLY SYSTEM I'JTERvhL: 0 l NON-DESTRUCTIVE EX'$HINATI ON SUN'R Y TABL f: PAGE n01 PERtno: J > SYSTEH.OR ~COHf.ONENT SW(24 )-2 DATE 08/20/93 ()urh(F: ~f( DESCRIPTION IS~A> '/OP B RETURN UR ho i g'. ' <- V- R.- 7 E)( A.-< . UATA S )(hv SHf ET NO ', I NSI GRIFT S I GN IF I C ANT I Df: (.T ~ ."I'. i" roI NO SW-Jl{l ( ) [ 5 1SWV-141 ACC HEAVY SURFACE RUST ON LUGS AND SW P IPING WITH NO APPARf NT LOSS OF

                                                                                                             )IiATERIAL SIP-f f   ( <I) v  r-3   1SWV-142                      hCC                             HEAVY SURFACE RUST           ON LUGS AND SW     PIPING WITH      NO APPARENT LOSS    OF MATERIAL V  T.-~  1SWV-145                      ACC                             HEAVY SURFACE RUST           ON LUGS AND SW     PIPING WITH      NO APPARENT LOSS    OF
                                                                                                         )Ii ATER  I AL SW-T)17- (       I')

v r-3 1swv-144 HEAVY SURFACE RUST ON LUGS AND SW PIPING WITH NO APPARENT LOSS OF HATER 1AL iP-<I ' ~ ) v 1 -3 lswv-151 ACC H INOR SURFACE RUST ON P IP ING WITH KO APPARENT LOSS OF MATERIAL STr-f)II ( ') V 1-~ ACC LIGHT SURFACE RUST ON SW PIPING 1SWV-14'SQV WIT;H).NO NAPP,ARENT LOSS OF MATERIAL Sl'-195(4) 154 ACC SINO'Li',SINQJ@E RUST ON SII PIPING wITHc~45~'4RENT )(ATERIAL Loss

4 w.J( W) 'g gj I~

VT-5 1SWV-110 ACC NO 5 +LE INDICATIONS SM- ) 9 ('<<') V T-3 1SMV-111 hCC NO Rf4, 8'!sE INDI CATIONS

PIP ',WASHINGTON PUBLIC R SUPPLY SYSTEM INTERVAL. NON-DESTRUCTIVE EXAMI ATION

SUMMARY

TABLE PAGE 00 f fRI;D: S YS T EM OR COMPONENT SIP ( 22 ) -2 DATE 08/20/93 t(UTA(iE: DESCRIPTION.,~S ~ QQP f1 RQTURtf f)R h'4 I NG IL 0 ~ IP g "~ 7 f XAMI ~ P'X DATA AQQNAT~J~RSU 'TS (I ~ SHf.E T NO INSIGNIF SIGNIFICANT I f) F tel T~ A

                     'N O ~         tif 'f v vo.               INDUC~      IQDJ~C        G EO  METR Y   OT HER  R~EAR KQ SI   - I)  1 ') ',

vr .>> 1>t V-0250 ACC MATERIAL LOSS ON THREE NUTS IN WALL PLATE ~ EVALUATED AS ACCEPTABLE ~ EXAM OF PORTION NORMALLY UNDERWATER.. Sq ~Ifo,( V T 'tt 1SMV-099 ACC NO RECORDABLE INDICATIONS VT R ~ ! 1HV-0255 ACC UNDER'HATER PORT ION ~ 5 MALL STUDS HAD SOME MATERIAL LOSS DUE TO CORROSION ~ STILL HAD FULL THREAD ENGAGEMENT ~ ACCEPT ABLE V T-~ J S'AIV-] 00 ACC NO RECORDABLE INDICATIONS

 ~O (I FliI 'i '.st       )

V ~ - . I SVV-I OI ACC NO RECORDABLE INDICATIONS Iy& Z* ( ~

                          )

VT-S 1SHV-It)2 ACC NO RECOftDABLE INDICATIONS Sit-"'9't '"( ' VT-g 1SMV-10~ ACC NO RECORDABLE INDICATIONS Ski- 'A~IT':-( -NF) VT "i 1S "wV-100 ~C C NO RE(ORDPBLE I NDI CAT IONS Sk-')2l "t g) V T:'lit 1S'~V-105 ACC NO ffktAHRD'AkLE INDI CATIONS SIP- Ts~ 7t, ( 'J) 1S'w'V-1 0 c> ACC NELlfggdlpgORTN SIDE OF PIPE ARE RUSfgf;"bIGHT'INOR UNIFORM CORR:ab S"-"2'<'t( tt) VT "5 f,SWV-107 ACC NO RECCO/DJIIlLE INDICATIONS

VNP-n~ MASHINGTON PUBLIC POMER SUPPLY SYSTEM INTERVAL: il 'l NON-DESTRUCTIVE',EX3iHINATION SUCH AR Y TABLE PAGE 003 PC)' i)D: SYSTEH'R* CdgPONENT SQ(22)-2 DAT E 08/20/93 t,'U I A ~"> f: 0 )i DESCRIPTION")~S~ j't)OP B RETURN LR hi' NG ') 0 ~ <'=!-.'s-.l 7 EX AN ~ f)ATA

                                  ! )t >t~ ~ SH'f:T 1l)Et T ..>    ~  ~             h f>       <~Q.

S4-~)2') '0( i) V T-5 1SMV-] 08 ACC SOUTH PAD MELDS RUSTY'IGHT HINOR UNIFORH .CORROSION SM-').S"') t '.') V T-3 1SMV>>109 ACC NO RECORDABLE INDICATIONS

WASHINGTON PUBL IC SUPPLY SYSTEM Nl)N-DESTRUCTIVE EXAMI ION SUMM AR Y TABLE PAGE 00 S YST EM OR 'OMPONENT SM( ZO ):g DAT E 08/20/95 DESCRIPTION ..SM SUPPLY HPCS L.OOP EXAM ~ DATA EXAMJ NATION RESULTS r Vtll~ SH!.E T NO .INSI GNIF SIGNIFICANT V fii N00 III.DQCx, gQQ~g QQOYigTR Y g TflER R EMARQS YT-5 1SLJV-1 12 ACC NO RECORDABLE INDICATIONS

<'NP-'3c'. WASHINGTON PUBLIC POWER SUl'PLY SYSTEM JNTLtt YAl,: t, l NON-DESTRUCTIVE'XAHINATION

SUMMARY

TABLE PAGE 001 l'F R 1 i)f): )-g 08/20/93 ('UTA'-rt . 'i!t SYSTEH 'OR DES COHPONENT CR'IPTI ON ~ SUPPLY T SW($ 0 0 FPC HX 1 A DATE f ISA W1NG l9 ~ 4 i i, EXAM. 1

                                                                       'X DATA            AH 1'NATION RESVt: TS f k'iM ~ SH';ET     NO            " I NSI GNlF          SI GNIF I C ANT I DEfJT ~ 'i0 SW-"4t-' ')

MTf ~

                            ~ h9 I ff[QQ f~"   -
                                                         /gate".-+'       Eg //AERY QT tkQR   R~ ARQS Y7       1SWY-153                   ACC                                  HEAVY UNIFORM SURFACE RUST WITH NO APPAR ENT MAT ERI AL LOSS

l ffi'-02 WASHINGTON PUBLIC R SUPPLY SYSTEM INTF. PV Ai . !l I NO N-DESTRUCTIVE EXAHl TION

SUMMARY

TABLE PfiGE n0 f f" R I f)0: SYSTEH OR COMPONENT SW(1?)=Z DAT E 08/PO/95 <'U T A!': DESCRIPTION: RETURN TQ RHR-HX-gA f.'f A 'k' NG LX AM ~ DATA ~EAH I HAT~If: JESUS'gS f".8 f'M ~ SHEET NO NSI GNIF S I GNIF I CANT I DE ffT ~ ~ 'f 0, "i Tll ~ NO ~ INDI C ~ I NDI C'e~ GEOM ET RY OTHER R EMARKS

 'i V,10",,"'> ('.;)

V T-5 1S WV-1~i2 ACC MINOR SURFACE RUST ON WELDED PIPE AND SW PIPING WITH NO APPARENT LOSS OF MATERI AL

 ':W-)0'," j(iu)

V T-". 1SWV-10o ACC HEAVY SURFACE RUST ON LUGS AND SW P1PING WITH NO APPARENT LOSS OF MATERIAL

MA SHI NG TON PUBL IC POME R SUPPLY SYSTEM f f4Tf'.VAL: j] NON-DESTRUCTIVE EXAMINATION

SUMMARY

TAf)Lf PAGE 001 f'f F( f "f): SYSTEM:OR COHP.OJENT SV(102) -2 DATE 08/20/95 Ufl T! i f... DESCRIPTIONS ~UPSY TO FPC-HX-J,R f iB A!. f f4 i, 'f n...,! - a fq EXAM ~ f)ATA F'x "' SHD. T N!T f NO ~NQQC~ QQQ~~"'. GEg MQQRY //HER R~EAQgQ v r-;~ 1SMV-147 ACC MINOR RUST ON MELDS AND SM PIPING Lt ITH NO APPARENT LOSS OF MATERIAL

  ~                      ~

4 WF - tlr~ 'AASHI NGTON PUBLIC SUPPI Y SYSTEM INDE((VA': {l I NO N-DESTRUCTIVE EXAMI ION

SUMMARY

TABLE PAGE 00 l FRt ){!: SYSTFM OR COMPONENT FPC (1) DATE OS/20/95 OUTA{ F: DES CRIPTI ON: FUEL P 00 1 C IR C/T K-10 {, 0 A l- I N 0 ') ".  ! l'= C -' l

                                                                                            ~  p F RAM.                    4       ,:P'i'~~
                                                                                                 ~

DATA EX AM I NATION RESULTS F ><~M ~ SHE F.' NO

                                                                           . INSI GNIF,              S I GNIF I C ANT I t)E "T ') D.                     <Jl 'T y l     NO ~           INOIC'NDICi i,'                 GEOMETRY OTHER          REMARKS Ff C-{~~     {')                                                                                                                        INDICATIONS V   T-.4       1FPV-01.")     ACC                                                     NO RECORDABLE E XAMINEO ACCESS IDLE AREA ONLY PARTIAL OBSTRUCTION FROM FLOOR F IRE SEAL INSULATION FPC-P ~-$ " ] {~{)

V T- . AP18iG ACC ALSO SEE REPORT 1FPV-012 ~ 2 OPM AT FLANGE MMR AP2809 INITIATEO TO FIX

<<Wf'-02 llASHINGTON PUBLIC POllER SUPPLY SYSTEM INTERVAL: 0] NON-DESTRUCTIVE:,EXANINATION SUNVAR Y TABLE PAGE 001 f'Ef< f nD: 0.s SYSTEM .OR COMPONENT FPC (2 )-g DATE 08/20/93 nUTA( f.: -.f~ DESCRIPTION. )PC' 1A TR Pf lA%1B ffft All ING 'fA 7 >C-7,!1 ". EXALT ~ DATA EX AflA.N~A~IQ~ES g~iS V ~w ~ SHEET NO ' NSIGNIF." S I GN IF I C ANT I DL f! T ~ .'>0. Q'f fJ flO ~ F<C-P ff -.'.? ( 1) V T-2 AP$ 8$ 5 ACC NO RECORDABLE INDICATIONS

Well% WASHINGTON PUBLIC SUPPLY SYSTEM I Nl f'V AL. 6 l NON-DESTRUCTIVE.EXAHI ION SUMNARY TABLE PAGE 0 I'f R I f>U: SYSTEM OR;COHPONENT FPC fg)-1 DATE 08/20/95 OUThbf.. LiRAW I'iil l." ~ I "'C-":0.I. f DESCRIPTI ON:", PQ-'P-gB TQ DH-QA$ gg EX All ~ DATA j ~ 'a~l >H: ET NO'.;- ':INSIGM;IF;-: SIGNIF I CANT I UE I ~ e '30 f~ -'iT l ~ NO INDI C INDICT~:- ~ GEONETRY OTHER R EHARKS Ff-'C-l-'B-505 ( 'l ) AP I 885 ACC NO RECORDABLE INDICATIONS

1.'WP- 02 IrASHINGTON PUBLIC POWER SUPPLY SYSTEM INTERVAL: 01 NON-DESTRUCTIVE 'EXAHINATION

SUMMARY

TABLE PAGE 001 VER t<)D: 0 < S YSTEH. QR" COMPONENT /PC (2 ) "1 DATE 08/20/93 OU T A('t.: DESCRIPT,ION'~P. '-'ga~B PJ~SHARQg DRAV IN'-"C-.cr,c EX AMi ~ DATA EX AHJQ~A. i

                                                     ~I/ -.~jgfS SHFET      NO    . -.;;>r',.;; X,lS I GN I P;..'     I G N I F I C AN T ID['tiT                 NO         ~Djg~'-'<<'QQQQ~C~>>.                    GEOQQQRY ~OHER         R~E. ARKS FPC-iiP.-504 < I )

V T-2 APIBBB ACC NO RECORDABLE INDICATIONS

  ~                       ~

I lgf f) >I 6 WASHINGTON PUBLIC R SUPPLY SYSTEM I N I f. R V A L: (" I ',VON-DESTRUCTIVE EX/HI T ION SUHIIIARY TABLE PAGE 00 I'Lf< I O{): S YST EH'. OR:COHPONENT FPC (3 ) -1S DATE 08/20/93 OUTA {>L: DESCRI'.P.TION I~QH-lA R f.TURQ I)RAV I>>C x>> ~ (l'C-30" l XAJ1 ~ DATA EX A H J N~~Q~-R ~St/"TS Ex Qt4 ~ SIH LET NO .i*= i'INSIGNIFf SIGNIFICANT I {)L HT ~ ~ 'J') NT!i NO+ FP(.-?4 5 VT bti 1HV-0247 ACC NO RECORDABLE INDICATIONS FPC -," 4 4 VT 'lf 1tl V- 024 7 AC C NO RECORDABLE INDICATIONS

f. >

V f 'tl ltlV-0247 ACC NO RECORDABLE INDICATIONS f-'{", 4 r, Vf~f 1tf V-0247 ACC NO RE COR BABLE INDI CAT IONS Ff'C-,'4 I V j,'rf I tl V-024 1 hC C NO RECORDABLE INDICATIONS Ff'( -Pl>,':, V I;:.-'f 1HV-0247 ACC NO RECORDABLE INDICATIONS

f Nl'-OP MASHINGTON PUBLIC POlJER SUPPLY SYSTEhf J WTE((V AL- NON-DESTRUCTIVE'.EX,AHINATION SU(Sf)if ARY TABLE PAGE 001 P f. f! I OD: ii .< SYST.EII;OR COHPOHRNT FPC l8 )-1 DATE 08/P0/9g OUTA (IE: ". ff DESCRIPTIOH.::~~ikP P-3 DISCHARGE f(f(A(; f N.-", f. ('C - 5 0 '? LXAH ~ DATA EX~AH NATION E;TS t y >,(r. SHEET tJO 'p:;.; (.'....".I NSI GM$F" S I GNIF I C ANT I f) E td T ~, X (( ~  !'l <<. h}g, INQL'gg,".'"QQ~Ce:: ." g Eg NggR Y @THER R~ ARKS FPC -E('j ('-') V T-.A IFPV-0<< ACC NO RECORDABLE INDICATIONS FP C-~i 0 (::. ) V T "5 1F f'V-015 ACC NO RECORDABLE INDICATIONS F f:C-P('-4 'l 1 ( ~, ) VT-P AP 1885 ACC NO P E CORDASLE I NDI CATIONS

IMP- i); MASHI NGTON PUBLIC & SUPPLY S YSTE 8 INrfi VAL: NON-DESTRUCT IVE EXAHI ION SUNHARY T PAGE 0 I'.P I Oi,): OR COMPONENT FPC (27) -1 ABLE'YSTEN DATE 08/20/93 <~UTAGL: L!q r.u I f16 ".)-'), )IC l r) ig "p 1j fXAH ~ DATA L'A:) ~ Sii LE T SIGNIFICANT I DEi)T ~ iO ~ I"i Tli t)0 ~ INOIC~ Jgg@~"='.- FPC-PB-i0r'(U) VT-2 1FPV-012 ACC NO RECORDABLE INDICATIONS

f;foal'l WASHI NGTON PUBLIC POMER SUPPLY SYSTEM 2 If4Tl I!V "L: N-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 002 f'le f r:D ~ 5 SYSTEM OR COMI ONENT FPC (27) -1 DATE 08/20/qP OUTA(.[: gH DESCRIPTION: '~PC- GATES TQ FP CI RC P R A k' f< a >,'4 f: . f' C - >, 0 EXAM ~ C DATA EXA~MNATIOQ 'REE~IQQS f Sf)LET NO I ... I NSI'GN IF SIGNIFICANT f:f ..'~('. s-"fll I bf ~ fv'0 ~ I N D I Qq 'ggQ/C ~ '> GEOMETRY OTHER REMARKS Ff f:-I'f<-51f (.~ ) V T-P jf PV-012. ACC NO RECORDABLE INDICATIONS

.-Nl -n2 MASMINGTON PUBLIC R SUPPLY SYSTEM IN TEPV hL ~ llI NON-DESTRUCTIVE EXAMI T ION

SUMMARY

TABLE PAGE 0 I'f:R I OD: SYSTEM OR CO/PONENT FPC(27)-1 DATE 08/20/93 OUTAGE: RH DESCRIPTION,P'RY~SEP Pffft-FP CIRQ URAl'NG "A ~ Fl'C- 0V. ( >L g E J EXAM ~ I f!E '-'1 ~ . "i'. l XhH ~ 8 I:i. f)ATA SHF.C T rln. NO =,'I INDI C~ NSI GN1K-", IQOQCa " S I GN IF I C ANT GEOMETRY gTHER R EMARKS F l'C -P I<-3 l l (: l ) V l-2 lFPV-0I2 ACC NO RECORDABLE INDICATIONS

fjP 0'> <AS)) I NGTON PUBLIC POMER SUPPLY SYSTEM t/JTt OVAL: l>1 MQ N-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 004 i'QR I Op; SYSTEM OR ~COMPONENT FPC(27)-g DATE, 08/20/95 f'UTA(E: '<P. DESCRIPTI t)g ~f't)NQAQB RETURN URA4 tl<: '4" o i..'C-~0>'XAM ~ +~a( cf

                                                 ~

DATA E X A 8 ~N~A~I Q,R~EQ+TS p z r y~ i ".<<F'E T NO 4NSIGNIF, S I GNIF I C ANT I fJE I'l ~ o 'q s i41'Is t 0 ~ f I Q-s:B- ~ Q ( ~

                           $ )

V 7-9 1 FPV-012 ACC NO RECORDABLE INDICATIONS 0

   ~                  ~

',-HP fI 2 MASHI NG TON PUBLIC, SUPPLY SYSTEN PAGE 00 [N fEPVAL: g] NO N-DESTRUCTIVE" ERA)fI ION SUNH AR Y TABL f l'f. !( I ~>0: SYSTEH, OR '-C6M/ONENT FPC (27) -g DRAFF DATE 08/20/93 (Uf AGE: DESCRIPTION 'P. -"/NCAA/8 TO L:"AGING MP ~ "i'C- <08 r XAV. DATA L.K A"4 St]EET

  ] Df. f$ 7 ~ .iiP ~        fP, 7   tJO ~

F f'C-f'-fi-0"' ~) VT-2 1FPV-012 ACC NO RECORDABLE INDICATIONS FF'C-PB- ~'. (~f) VT-2 1FPV-012 ACC NO RECORDABLE INDICATIONS

~ f'. NP lNT R I ('D: h L:

                  '33
                       'J I WASHINGTON PUBL IC PO~AER SUPPLY SYSTEM WON-DESTRUCT I VE EXAHI NAT I ON SUCH AR Y T ABL E SYSTEM OR COMPONENT          RCC(g)-g                      DAT E PAGE 001 08/20/93 PUT Ac," E:                                                    DESCRIPTION .RCC SUPPLY-FPC-HX-1A fJ R A l I f N Cj 'J 0   ~

Pl l )() EX Ath ~ DATA EXAMINATION.RESULTS P li'I g ,"lf EE T NO, '"'- INSI'GNIP.' SI GN IF I C ANT f 0 t VT ~ ~ w O ~ I>> T i> ~ f40 ~ RCC-r'i<-.< ". VT-7 AP2132 ACC NO RECORDABLE INDICATIONS

VNP-02 WASHINGTON PUBLIC R SUPPLY SYST EM I NT E ff V AL ~ 0 ) NON-DESTRUCT I VEcEWA51 T ION

SUMMARY

TABLE PAGE 00 f'f:P I DD: S YST,EM'OR-~CORPORE.'PT RRC (4 )-2 DATE 08/20/93 OUTA Gf: F ROM HX-1A ING '40. 0 CC-504 R4'PRAV f.'X AM ~ DATA EX~M/.fag I ION S " 'S E x 'a:-'.

                                           ~ SHf. f T    NO ~ . ':. ', " I;NSI'.GN,':KFj'-   SIGNIFICANT I DF NT   ..'! r>.             M Tif~       NO   ~      mDJi =:-"'""i'i5~f&":t.m MfTRY               QTHgR     REMARKS RCC-P!)-.',4 (ti }

V r-2 AP 2132 ACC NO RECORDABLE INDICATIONS

'P-02 MASH I NGTON PUBLIC POME R SUPPLY S YS TEN 1f'f TF. f;V AL,: 01 NOtk-OESTRUCTI YE'XAMINATION SUAN AR Y T ABLE PAGE 001 PERI OD: SYSTEH OR COMPONENT FfS($ 8)-g DATE 08/20/93 OUTAGL: ~ P OEiS CRI PTI'ON ~SARY-5A OI SCH AR GE [>R A".I ry 0 tf A. LX AH ~ 67'X DATA EX AH~IA ION R ES TS h" ~ SHEE T NO '-.

                                                        "- . INSI4)QJ 'IGNIFICANT II)f f:T   o ~ .) 0 ~  Ff TH ~  KQ.         IEQIH~- LHQ~-""-'-           QK95KIRY Qj;f<KR RQl4R55 fifh VT5!f    1H V-0246   ACC                                           NO RECORDABLE INDICATIONS
 <iS- 27,~

Y T-.'iH 1H V-0246 ACC NO RECORDABLE INDICATIONS f<S- " I 4 f lf V-024'CC NO RECORDABLE INDICATIONS h'!S ~'7 ~, YT 'H 1HV-0246 ACC NO RECORDABLE INDICATIONS

 <<Sfh   V- ') f,- /i 3 HV-0246   ACC                                           NO RECORDABLE INDI CATIONS

0 ~ 'P- i)2 WASHINGTON PUBI,IC SUPPLY SYSTEM INTERVAL: !'I NON-OES7RUCTlVE,)gXAHI I ON SUMM AR Y TABL E PAGE 00 ( rR1OP

         ~    r, q                            S YST EM OR CORI.,QgENT         gS ( 18 ) 2-10                DAT E 0 8/20/93

( UTA (;E: )" 8 DESCRIPTION'. '.Q~Rg-$ 8 DQSCHAR Gf DR h" 1 rJ('lo ~ rXAN ~ DATA EX~A~A~Q-' S "; S EN AN ~ SHLET NG.: -: <INGIGl)JN'", SIGNIFICANT I DC NT ~ . '(0 ."i T)( r.o MSR V-1) -2 ( a! ) V T-.l 1 "ISV-1(8 ACC NO RECORDABLE INDICATIONS MS-2P ] ( ~') V T-3 1MSV-106 ACC NO RECORDABLE INDICATIONS MS- r" Mr" ( -' V T-3 1MSV-147 ACC NO RECORDABLE INDICATIONS

L:NP-0" MASHINGTON PUBLIC POMER SUPPLY SYSTEN INTEhVAL: 01 NON-DESTRUCTIVE'i@HINATION SUMH AR Y TABLE PAGE 001 PCH I OD: 05 SYS'TEH."'QR CQ.H, OQENT HS( 18-) 2-13 DATE 08/20/93 (!UTACL:. P/> DESCRI.P.,TION ~;~" < V-4B DISCHARGE UR A, IN G ln. ':: -.-:,'8

                                     .".X 4!0 t

MENTION

                                              ~

DATA EX~AH 'f~E'TS

                             ~l  H ~ Sill;f. T    NO <'=    ". I $ S:Egg IF-'... S I GN IF I C ANT I DEN I ~ ~ <<'.) ~        YTH       I  0 ~

i<SR V-4 rl- H 1HV-0246 ACC NO RECORDABLE INDICATIONS

0 0 L'NP-(:2 MASHINGTON PUBLIC R SUPPLY SYSTEH I (V T C f( V )') L ~ 0 1 NON-DESTRUCT'I'VE'E)'$H T I ON SUHH AR Y T ABL E PAGE 0 f'f P]PO: I S YS YEH.,';OR "COHP~ONENT CRD (g2$ -g DATE 08/20/95 nUTA ('E: DES CRIPTI,ON+:i<L4D 'SCRAH DISCHARGE l'RAM]NG>>O. CRr;-.. 0] EXAH ~ DATA 'R ES TS EX AN~NATION< SHEET NO F'.;:)'-"> ') NQ I'Pl' S I G N I F I C AN T un. REHARKS 1 Cf<P-001 ACC NO RECORDABLE INDICATIONS PSI OF NEM MELD PLAN 2-0878 8CRD(]; I A-'.); /Pf:L(; S (! P. 1 CRH -0 0 1 AC C NO RECORDABLE INDI CAI TONS PSI OF NEW MELD PLAN 2-0878

4fJP-0? tJASHI NGTON PUBLIC POWER SUPPLY SYSTEM I AJTf f(VAL: IJ] ,AJON-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 001 f'f'ffI ITD, El 3 SYSTEM OR COMPONENT CRD (12) -3 DATE 08/20/93 OU f A ('L: ff RAW I NG i" 0 ~ Tg I ~A () ~ LXr M.

                                                                           ".  ':I'I DESCRIPTION:'.CRDI SCRAH DISCHARGE 1, f DATA              EXANQJATION- ~RESU    ".TS
                                         'I ~ SHLf    T         NO   . I NSI GN /lj'. SI GN IF I CANT fur Uf .. JO.                I! 7'i ~                      INggg~    'gg~e".."'-'     EO MQT R Y QT HQR  R~EARQS f~CRrT( 1.>)    B- TI.! /P;L.

SUR 1 C R, I-O 0 5 AC C NO RECORDABLE INDICATIONS PSI OF NEW WELD PLAN 2-0878 BCR II( l ") ' "'-'/~ f LG SUP 1CRN-002 ACC NO RECORDABLE INDICATIONS PSI OF NEW WELD f LAN 2-0878

JASHI NGTON PUBLIC. SUPPLY SYSTEH NON-DESTRUtCTIVE<.EWfft'HI ION SUHHAR Y TABLE - PAGE 00 I','R I Ofl: SYSTE)i OR,. CtlHPOAENT ~SC(g)-4S DATE 08/20/93 (iUTA(L: DESCRIPT'I ON ~ .'.,Q~P UHP QJ SCH AR GQ URAV T X<0 fO..",LC-101 EX AH ~ y ~- DATA "ttt i&ltJLJi':t E x hfdf ~ SHEET NO . "~ji%~'~.f,NSI.'CN'iP:i S I GN IF I C AN T I DENT ~ ~ Y.-.O ~ H Tlf ~ iN0 ~ INDICT." I~dgC~;.":~:. GEOHETRY OTHER R EHARKS SLC-f" D-I fly (L ) V T-2 1 V T2-93 AC C NO RECORDABl E INDICATIONS

1 W~-Oi WASHINGTON PUBLIC POIJER SUPPLY SYSTEM f NTf'RVAL: 01 NON-DESTRUCTIVE. EXAMINATION SUMM AR Y TABLE PAGE 001 f'E P I OO: ". 3 SYSTEM: OR'-COMPONENT CCH (P ) -g DATE OS/20/93 OUfniE: <n URA" f NG '~O / DES tRIPTION ~P A/8 CCH

                ~

EXAM ~ DATA EXAHINATJQg.: R~E: JS r A~@ SH f.'E T NO ..:":l>'hfD+C INSIGN'l1",SIGNIFICANT 1UL Nf ..'<<. M T'3 ~ NO ~ INDI C ~ ~ ":. GEOMETRY OTHER R EMARKS Cell-Pn< < >

                    '0 T-2   AP2160      ACC                                        NO RECORDABLE INDICATIONS AP 2131     ACC                                        Nn RECORDABLE INDICATIONS

VNP- MASH I NGTON PUBL IC SUPPLY SYSTEN INTERVAL. ] .'CON-DESTRUCTIVE '-EXAHI ION SUAN ARY TABLE PAGE 00 PERIOD: 0 5 S Y,S'f hH:<OR CQMPOQ,ENT RPV DAT E 08/20/95 OU T A GE::1 P. DES 1:RIP/I ON;;.SHL~".CR S 8 SKRT KNKL DRAM] AGIO i~i 0~ "PY-] 0 ] EXAM ~ tP el DATA EX ANIL~IIN'. RES:T;S E X,gP' SHEET NO :0 '>:;~'I NS.I GN XF.ri- S I GNIF I C ANT ID] NT ~ ~ 10 ~ N T'< ~ NO ~ INDI 5"' '/gal+~~ Q~E VO'-R8-005 <5,60 0 0 DEG INDICATIONS EVALUATED AS S I.GR E G AT ES COVER AGE = 99 ~ 8X V f]L F-Re=00> ~5,60 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVER AGE = 79 ~ 7X SEE NOTE 2 VOL R-R8-025 45 y60 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVER AGE = 92 ~ 0 X, CG

                      ~

S UR 1R P'1-0 58 AC C NO RECORDABLE INDICATIONS VOL 8-RH-015 Oy 45 i 60 NO RECORDABLE INDICATIONS COVERAGE = 90 'X. VOL R-RH-006 45>f 0 0 0 DEG INDICATIONS EVALUATED AS S EGR EGATES COVE/ g~;=, 91 ~ 9 X VOL R-RH-01<> e5 >60 0 0 DE, ~~/)5$ ATIONS EVALUATED AS S EGR /@i C OV.EQ@@~g:1' X Wl gjt p <'f'*

>Nr-0; WASHINGTON PUBLIC POMER SUPPLY SYST EM 1MTLRV i I: 0 l NON-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE PQ2 l'( 8 I 0(': P. S YS T EM -OR ~ COMP Op ENT RP V DATE 08/20/93 T 4 t. L: <i 8 DESCRIPTION ~C~Hj,L, Cg URSUS i <8 E V 1il(~ ':: 0 ~

                          ". ' -1 il ]

f XA~ ~ DA TA X <ii ~ SHL'ET NO I NS I GN IF SIGNIFICANT IOLi<T~o ~" ~ l$ T<1 ~ lg O INDI C INDIC~ GEOMETRY OTHER REMARKS R-R8-00 1 il5 e60 0 0 DEG INDICAT I 0NS EVALUATED AS SEGREGATES COVERAGE = 92 ~ 8X BE V (H. R-RH-016 05 y60 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVER AGE = 98 ~ 1X V r l. 8-RH-001 05 e60 0 0 DEG INDICATIONS EVALUATED AS S EGRE GAT ES COVERAGE -" 95 ~ 6X V iOL r-R8-00~<<(5+60 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVEP AGE = 98 ~ 1X BH VOL R-PQ-002 05 60 n 0 DEG INDICTTONS EVALUATED AS SEGREGATES COVERAGE = 93 'X VOL -". -R8-01 'l 60 0 AD%5 0 DE/.iIQDICATI ONS EVALUATED AS S EGRBQ,Pg~j COVE;RAGF"-+9,1 ~ 7 X VOI R-88-023 t5 e60 0 0 DIG:PI'iig(CATIONS EVALUATED AS S EGk'GC'$,7@m gw',.l4;

                                                                                                               <i?
                                                                                                                          <9(i(f+'>>;

y~g'.

                                                                                                                -$ ."'i("y,'.~3.'".c'-i
 ~                 0 k NP- (I2                                        MASH I NGTON, PUI3L.ITC                 SUPPLY SYSTEM INTf:RVAL- 01                                  NON-OESTRUCT'IV.F+BJtAHI              I ON SUCH AR Y T ABL E                    PAGE 00 Pf.RI f)f): 0 c                                            EK)00~00$ III0( EST                                             DATE 08/20/95 STTST OUTAGE: CV                                        DES   GRIP/ION ~'.,0~ELQ         COURSES

[sRAL INCi XO ~ Rl V 101 EX AH ~ DATA EX'~AQ~T I'Og;R ~, S f.XA ) ~ SHEET NO~i sf'~-~ "=~I;klSI,gg'IF~'~ S I GNIF I C AN T I OE. NT .. "") ~ T'l ~ <0 ~ VOL ".<<f10-017 95 060 0 0 DEG INDICATIONS EVALUATED AS S EGRE GAT ES COVERAGE = 92 ~ 1X VC'L P-RH-020 05 060 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVERAGE = 60 ~ SX VOL R-RB-027 Q5 0 60 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVER AGE = 62 ~ 9X VOL R-R8-026 Q5 060 0 0 DEG INDICATIONS EVALUATED AS SEGREGATES COVER AGE = 60 ~ 3 X

W9P-OP WASHINGTON PUBLIC POWER SUPPLY SYSTEM ' I N TE f( V A L::( 1 NON-DESTRUCTIVE,'EXAMINATION SUMM AR Y TABLE AGE non

'f." f )D:                                             SYSTEM      OR    COMPONENT              RPV                        DATE  08/20/93 (1U1  D (,E: 4))

f'((~" I'0( ' "l'V-I0 DES CRIPTI ON. gggIES:

                                                                                .)~~.

SHELJ, 1 f.X AR ~ OA1A ~E~A I NA J ~If Q~EQQS f: i "i4s ~ ~Hf'.f 1 NO -, ~ I N SI 6/4'F.'., S I GN IF I CANT 1 UL HT ~ ~ '~!>. Y1'f ~ (iO o INDI C ~ INO~C'i~"'- ~ GEOMETRY OTHER R EMARQS Nii- <0- f c VOL 1RPU-119 70 NO RECORDABLE INDI CAT IONS VOL 1RPU-11'9 25 NO RECORDABLE INDICATIONS

QhfP-07 MASHINGTON, PUBLIC, SUPPLY SYSTEH IhlTC~VAL: ~ll NON-DE:STRICT$-:VE;-')gfAHI ION SUMN AR Y TABL PAGE 00 l F.R I ~D: 03 SYST~gk~'OR CO)AAKAT RPV DATE 08/20/93 OUTA GC: %8 FI V-101 DES',)lP.T'ION'Q), ~R REP~AR ARE AS DRAWING "~0 ~ CX Ah'l ~ DATA 1 ',IQ J! I 5 JIERULIR EXAM ~ SHEET NO "-..f t <l~<INSIGNjf~~ SIGNIF I CANT 1DENT ~ .'lO. hl 1 ll ~ hO ~ ~I+DC":-": J,gggge'.~'".~.*- g EllNjTR~ QT HER hlRP -1 VOL R-R8-022 95t60 0 0 DEG INDICATIONS EVALUATED AS ACCEPTABLE COVER AGE = '00 X

f, i'J P '.I WASHINGTON PUBLIC POMER SUPPLY SYSTEM I~J TE J.-VAL: ' NOi'J-DESTRUCT'I VE ERQMINAT ION SUMM AR Y TABLE PAGE 006 l'f RI OD: 'J3 SYSTEM<<OR. COMPONENT RPV DATE 08/20/93 Off I hfdf.: DES GRIP TI Olla JR 0V; STUDS'UTS'T C f}RA'A ll'jl NO '- f'V-1 JJ I f.XAM ~ EX AMJ NAtJI'ON RESUL'-TS I DE lJT ~ ".0 r X iif-;. ill f'J ~ DATA SHi.E T J'J Q 0, 1NOIg~

                                                                           ~
                                                                             . IIIJSI'GNIF;'IGNIFICANT IQD~.~      QEOMQTRY @THER   R~EARKS fff'V .'T<<JJ          <     7A VOL        1P.J   U-120    0                                           NO RECORDABLE            INDICATIONS SUR         1RPJ>>-03    J   ACC                                         NO RECORDABLE            INDICATIONS P.f'V ~ f'<"i        '='- 11k    h V (.'l     1RPU-120        0                                           NO RECORDABLE            INDICATIONS 1RPM-039       ACC                                         NO RECORDABLE            INDI CATIONS "T')". l ,.1          SU'f'V A

V J-L 1RPU-120 0 NO RECORDAOLf: INDICATIONS S fili 1Rf'M-039 ACC NO RECORDABLE INDICATIONS RPV STD J "~-) ->>:h VnL 1RPU-120 0 NO Rf:CORDABLE INDICATIONS 5 O'J 1R P J>>-039 AC C NO RECORDABLE INDICATIONS RPV ~ Ti!iJ 4'"-7-3"ih, VnL 1RPU "120 0 NO RECORDABLE INDI CAT IONS SUB 1RPM-039 ACC NO RECORDABLE INDICATIONS Rf<<V ". TUO 35-1-<<<<2A V Ol. 1Rf'U-120 0 N O,gE~QQR DPB L E I NDI CAT IONS

                                                                                                                              <<Skt i SUB        1RPM-039       ACC                                                                  INDI CA T IONS Rf'V STiJD          35-I-49A VOL        1 R  PU-120    0                                                                    INDI CAT IONS SUB         JRPM-040       ACC                                                                  I NDI CAT IONS RV   l    STJJ-J    3cj       1  56A VOL       1RPU-120        0                                           NO   i<<$$(R,ARABLE INDICATIONS
                                                                                                                              ~

Q+q/QJ lq J,>>

1JNP-02 - fJASHI NGTON PUBLIC SUPPLY SYSTEM I NTC If VAJ,: NON-OESTRUC/IV.E~;Ej)WI ION

SUMMARY

TABLE PAGE 00 f'EP t AD S YSTiEH -OR'OflP.,0$ ENT DATE Oe/20/93

         'UTAGC:
                    >lf                                          DES.CRI~P.T;I.ON   '-V   STUDS~ NUTS~ ETC URA1JJNG             ~n. -;l     V "X AJ1 ~

DATA EX AH I NAT1.0N "-'R 'S~OCS Ex AH ~ SHCET IDENT ~ ~ JO i>. I II~ f00 e SUR lR PH-040 ACC NO RECORDABLE INDICATIONS RPV ST f l'! VOL 1RPU-120 0 NO RECORDABLE INDICATIONS SUR 1R PJ1-039 AC C NO RECORDABLE INDICATIONS RPV STUD 3".-1-70A VOL 1RPU-120 0 NO RECORDABLE INDICATIONS lR PM-039 AC C NO RECORDABLE INDICATIONS RPV NUT 3c.-1-7h VOL 1RPU-121 Oq 37 q 45 NO RECORDABLE INDICATIONS S UP. 1RPM-041 ACC NO RECORDABLE INDICATIONS RPV NU f 3~ 14A VnL 1RPU-121 0~ 37 ~ 45 NO RECORDABLE INDICATIONS SUR 1RPM-041 ACC NO RECORDABLE INDICATIONS Rf'V NU f 3t'~- 1 -21 A VnL 1RPU-121 Oe 37 F 45 NO RECORDABLE INDICATIONS SUR 1%PM-0 ll ACC NO(k ORDQB,LE I NDI CAT IONS RPV JJUT 36-1>>2BA VOL 1RPU-121 1 RPM- 0 4 1 0>37145 ACC No:.gflp (g)(8e J INDICATIONS INDICATIONS RPV NUT 36-'1-35A

                              ~

VOL 1RPU-121 Oq 37'5 INDICATIONS SUR 1RPH-041 ACC NO R'E'f54'0&LE I NDI CAT IONS

I off. - I' JASHINGTON PUBLIC POMER SUPPLY SYSTEM I Ni T f. f' h f.: 'i 1 '40N-DESTRUCTIVE.,EXAMIN AT I ON SUMM AR Y TABLE PAGE 008 pf'I? f nfj ~ SYST EM OR COMP;ONENT RPV DATE 08/20/93 AUIhpi: IH DESCRIPTION'I.'RPV STUDS'UTSg ETC I 5[ *'gCky Ufi au I f fr >I

                                                                                       ~
                                              'AM   ~

g DATA X AM ~ SIILLT IDEI. T,--.O 'I 7 if "(0 ~ PF V 'IUI:,i.-f-42A VOL 1Rf'U-121 Oy 37 y45 NO RECORDABLE INDICATIONS SUR 1P Pv-041 ACC NO RECORDABLE INDI CAT IONS RPV NliI VOL I RPU-121 Oy 37'5 NO R E COR DABLE I NDI CAT'IONS SUR 1RPM-041 ACC NO RECORDABLE INDICATIONS Rf'V Nili I 3i)-1-5 i, A V;>L lRPU-121 Oy37y45 NO RECORDABLE INDICATIONS SUR I RPM-041 hCC NO RECORDABLE INDICATIONS RPV NU f 5[)-1 -( 3>> VnL IRPU-121 Oy37q45 NO RECORDABLE INDICATIONS S Uf~ I RPM-04 I ACC NO RECORDABLE INDICATIONS HPV tJUT 3~:- I - 7flh OL 1RPU-1 2 I Oe 37 5 45 NO RECORDABLF. INDI CAT IONS SUR 1RPM-041 ACC NO RECORDABLE INDICATIONS R PV '." h > I LR 6 V T-l 1RPV-lt)6 ACC WASHY/S,,VERE EXAMINED FOR THE F OLID+'NP)EST UDS: 3 5-1-7 A ~ -1 4 A ~

                                                                                                            -214'.jgkklfy -35 Ae -42Ae 49Ae -56A
                                                                                                            -63"'i:;,< 7,OAT NO   RECORDABLE I ND I$4TQ ON8' j>>'+iL~'q'~
  ~                  ~

V.tlP- (f2 WASHINGTON PUBLIC, SUPPLY SYST EH-INTf ffYAI: "1 NON-DES.T$ UCTfVE.','6 'Nl ION

SUMMARY

TABLE PAGE 0 f ERI oD; 03 SY,3't.kh'";O,R XCihph .ENT DATE 08/20/93 OUTAGE: 98 EXALT, ORAl4I WG W(). Rf'V-101 "@3'."-"'~~A@4A'rv:

                                             ~

DATA E)(hN ~ SHEET NOy~:" W~~<:;IN,IS - 8"'~ SIGNIFICANT I DE NT 8 f) ~ N T!i. rzo, ~I+0$~4>g "t w'4, gzfPH fTRY /THER R~ARKs JET P!)f,P <<F.ANS C V T "3 1RPV-167 ACC NO RECORDABLE INDICATIONS VOL 1RPU-122 ACC NO. RECORDABLE INDICATIONS JET PUN~ S."-:tfSI NG LI")ES V T-1 1RP V-167 ACC NO RECORDABLE INDICATIONS CORf. Sf'RAY SPARGERS V T-1 1RPV "167 ACC NP RECORDABLE I NDI C'AT IONS STf.kN !)%Yf ~ VT-3 1RPV-167 ACC NO RECORDABLE INDICATIONS RPV-PO-101(L) VT-2 1 VT2-93 ACC NO RECORDABLE INDICATIONS

Wr]f'- 02 WASHINGTON PUBLIC POWER SUPPLY SYSTEM ]n]Tr]'V~L- 0 l ]40N-DESTRUCTIVE EXAMINATION

SUMMARY

TABLf: PAGE 001 f'~]r. f ri )') S YST EM OR COMP ONENT RPV DATE 08/20/9q UT 0!if.: DESCRIPTION ~ ~T L BOTTOM HEAD lrp Al~r l N(. 'i Oi ~ r~ ~'V-I 0 ~ ) regig PC <<<

XAMr ~

DATA j< SHF'E NO: '. I NSI.GN.IPr S I GNI F I C ANT I f)l l'lT ~ ~ =40 ~ l'l>]

                                         ~

f'<n. INDI Ce - INO~Ce~,>>'EOMETRY OTHER REMARKS j) Ai VnL R-Hff-008 Oy 45 t 60 NO RECORDABLE INDICATIONS COVER AGE = 78 ~ 6X SEE. RELIEF REQUEST 2" IST-001 0 I] V(1L fk-RF]-01~ Oe 451 60 NO RECORDABLE INDI CATIONS COVERAGE = 78 'X SEE RELIEF REQUEST 2-ISI-001 OC V".L R -RO-009 Oy 45 q 60 NO RECORDABLE INDICATIONS COVER AGE = 78 ~ 6X S EE R EL I EF REQUEST 2" IS I-001 DD VOL R-RB-010 0e 45 e 60 NO RECORDABLE INDICATIONS COVER AGE = 78 ~ 6X SEE RELIEF REQUEST 2-IS I-001 VOL R-RB-011 Oy f5q60 NO RECORDABLE INDICATIONS COVERAGE = 78 ~ 6X. S EE R EL I EF REQU EST 2- IS I-001 Df-V(rL R-R8-012 0~ 45 f 60 NO ggCOPPABLE INDICATIONS C OV E8$ 5E..'~P 78. 6 X SEE;.R:EC~XFFpREQUEST

                                                                                                                     ..iy'i)(gf,"~

2-IS I-001 n,] VnL R-R8-019 0>> 45 y 60 SPOT/'TgglgPTION RECORDED AT 50X D A8,+P.) q,']'DE G

MNP-02 WASHINGTON,,P.UBL',g SUPPLY SYSTEN INTERVAL. 01 NON-OESTIhCT~lgg,-k '4HI ION SUHM AR Y T ABL E PAGE 0 PERIOD: 0 3 Sf;SgXk;-'~Ok"~<',".Chal,.'khT DATE 08/20/93 OUTAGE: RB DRAWING '~{) ~ RPV-I0P EXAM ~ tsar DATA EX A!1 ~ SHEET NOj..f~gi'$~g')j';Q'N,0 'NQ'.i(4;;i I I S I G N F C AN T IDENT ~ ~ f! 0 ~ 8TH ~ NO ~ ~IND 'C~+"-'.<p~b~Ca~~~<:" GEOMETRY OTHER REMARKS DG l VOL R-RB-021 45y60 0 0 .DEG SPOT INDICATION UNDER 50X DAC COVER AGE = 16 ~ 6X SEE RELIEF REQUEST 2-IS I-001 nR VOI R-RB-020 45%60 0 0 DEG SPOT INDICATIONS RECORDED BELOW 50X DAC COVERAGE = 16 ~ 7X SEE RELIEF REQUEST 2-ISI-001

                                                                                                             'V

'4>JP-OP JJASH I NGTON PUBL IC POMER SUPPLY SYSTEM JRJTrRVAL: NON-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 003 f EP[OP S YST EM OR'COJIJP.ONENT RPV DATE'8/20/g3 OUTA GE: '1 JJ DES GRIP TI ON.' TOP.* 8 BT M HD NOZ ZLES JIR A P J (4 G 4 O~ > <> y E

                                                                      -~

EXAM. I UE NT ..-'T.."a J.". M Ai ~ Til ~ DATA SHEET QQx EXARCH NATION NO LHQLE~ 'HQLCa

                                                                 ~RESU
                                                            'NSIGNIF TS SIGNIFICANT QEOMQTRY   /THER  R~E'RgS c)SP ARr VOL       1RPU-118   65                                            NO RECORDABLE     INDICATIONS CIRC SCAN ONLY RPy-+I -1;~,'x(t     )

V I-2 1VT2-93 ACC TMO AREAS DRIPPING AT 3-5 DPM EVALUATED AS NOT FROM PRESSURE BOUND AR Y ~ SOUR C E CONDENSATE

0 'WNP-02 WASHINGTON'UBLIC,. R SUPPLY SYSTEM INTERVA Ol NON;.PES. AIICj'IAY.QIANA TON SUNN ARY TABLE PAGE 0 f'ERIOD: 03 S,YS'J. Hi'OR<..((dN ', 'RNT ~RC C (g~4 DATE 08/20/93 OUTAGE: R8 DRAWING f40. PCIC-Ig) D5 C $ $T$ $ )g 4i-STEAK SUPPLY E XAR( ~ DATA EXAH ~ SHEET NO,Q~":P~>P>PSS$ , .; - S I GNIF IC AN T JOENT ..NO. +TH ~ NO ~ t"." ITEBNf~RY gTH R R jPARQS RCIC-1C-2(M) SUR IRIS'-033 ACC NO RECORDABLE INDICATIONS 4RCIC(13)-12 VOL 1R IU-063 45 NO RECORDABLE INDICATIONS 4RCIC(13)-13 VOL IRIU-056 180-0 DEG 159K DAC ROOT GEO 4RCIC(13)-l4 VnL 1RIU-057 0-180 DEG 85K DAC ROOT GEO SUP 1R IP-015 ACC NO RECORDABLE INDICATIONS 4RC IC ( l." ) -15 VOL 1R IU-058 0-180 DEGREE 80X DAC ROOT GEO S UP. 1R I f'-015 AC C 'O RECORDABLE; INDICATIONS 4RC IC (13) -16 VOL 1R IU-059 180-0 DEG 88X DAC ROOT GEO SUB 1R IP-015 ACC NO RECORDABLE INDICATIONS 4RCIC(13)-17 VOI 1R IU-060 45 0-180 DEG 55K DAC ROOT GEO SUR 1R IP-015 ACC N04$ ., YXAa".*e~~glL!~IRAQI"q SLE

                                                                                                                                 'jQ INDI CAT IONS 4 RC 4RC I C (13 ) -18 IC(13) -19 VOL VOL "SUR 1R 1R 1R IU-061 I U-062 IP-015     ACC O'-,"K'.,j.

o-.i; NOjg

                                                                                                                  'X                   .

jl DAC ROOT GEO PAC ROOT GEO NDI CAT IONS N RCI C-~B-101 (L') V T-2 1VT2-93 ACC g'- I NDI CAT IONS

le',)4P f) Q WASHINGTON PUBLIC POWER SUPPLY SYSTEM I)4T E ~r V nL: NON DESTRUCT I VE;.'EXA MIN AT I ON SUMM AR Y T ABL E PAGE'01 I'ER I IAI,": SYSTEM OR ~ COMPONENT RHR~(g) -4 DATE OS/20/93 GE: >>! DES,CRIPTION ',~RP =tIEAD /PRAY 0.'UTA DRAW IN)': .;O. I CI C-1:;.;

                                            'AII.

DATA EX AM~N~fOg'. ~E~Tg

                                                                   '""' INSIGNIA>>

E I(AM. SHI ET NO SIGNIF ICANT 1[)f NT . ~ '}O ~ AA T)l UQ= ~TI Qgg~r 'gQ~Ci'>>': g~MQTRQ QT HER R LQARgS P)ER -52!) V T3H 1HV-0246 ACC NO RECORDABLE INDICATIONS R)IR -97' V T3H 1HV" 0246 ACC NO RECORDABLE INDICATIONS RCIC-V-1'5-ALT V T-1 1%IV-013 ACC MINOR RUST ON SOME NUTS AND STUDS ~ NO APPARENT MATERIAL LOSS RCI C-102 V T:H 1HV-0246 ACC NO RECORDABLE INDICATIONS RCI C-] r) 5 V T3H 1 HV-0246 AC C NO RECORDABLE INDICATIONS R C I C-1:) 4 V I.4H lH V-0245 ACC NO RECORDABLE INDICATIONS RCI C-V-65-UL T VT-1 1R IV-012 ACC NO RECORDABLE INDICATIONS 6 RCIC(1)-I3 VOL 1RIU-055 45 NO RECORDABLE INDICATIONS 3UR 1R I)I -034 AC C NO RECORDABLE INDICATIONS 6RC1C ( I ) -14 VOL 1R I U-054 45 NO RECORDABLE INDICATIONS SUR lR IAA-034 ACC NO'A$ bgs LE INDICATIONS RC I C-9nr.'4 Ni e 'IfAf+ VThrl 1HV-0246 ACC NO RQCOf~t45LE I NDI CAT IONS RC I C-939)4 V T3H 1HV-0246 ACC NO-fK OP E INOICATIONS 6RCIC(1)-28BD V T-1 1RIV-014 ACC MINOif<CO(R SION ON STUDS BETWEEN FLAhjQC'kq.jan('PP ARENT MATERIAL LOSS

WNP-02 WASHINGTON <<PUBLIC.'. SUPPLY SYST EH INTERVAL. 91 NON-t)fiSTRUCTfgEjg,g I ION SUNNARY TABLE PAGE 0 PERI OD: ') 3 DATE 08/20/93 OUTAGE: '?8 D,ES5 3P.; 6W < 0:, EAD SPRAY AH:-.. I C-1 02 n DRAWING NO ~ i? C EXAV DATA S EXAN ~ SHEET NO';:t;"j,'~gPf Xqg F,~~ SIGNIF ICANT IDENT ~ .lJO ~ 6RCIC(1) -3] HU h! TH ~ HQx ~V.,g $~'w Q~g fJ R Y QT H f R YT-1 1R I V-011 ACC FLANGE WAS BEING DISSASSEHBLEt),, FOR~;:. R EFUELING 6RC1C(1) -41 ADD YT-1 1R IV-015 ACC NO RECORDABLE INDICATIONS PSI ON NEW BOLTS PLAN 2-0947 6RCIC(1) -44BD Y T-1 1R I V-016 ACC NO RECORDABLE INDICATIONS PSI ON NEW BOLTS PLAN 2-0947 6RCIC(1) -45 VOL 1R I U-053 45 NO RECORDABLE INDICATIONS RCIC-PB-102(I ) YT-2 1VT2-93 ACC NO RECORDABLE INDICATIONS lg

                                                                                                %I
                                                                                                   ~

VNr-02 WASHINGTON PUBLIC POlJER SUPPLY SYSTEM INTERVAL: Ill NON-DES TRUC T I V( EXAHINAT I ON SUMM AR Y T ABL E PAGE 001 I'ERIOD: 0 3 SYSTEM OR COMPONENT R CI C ( 10 ) "1 DATE 08/20/93 OUTA GI;: %8 DESCRIPTION'..;~UP SUCTQ~ LgNgS ORA4 IN 0 lNQ ~ > CI C-2 0 EXAM ~ DATA EX AMI:tI~AIOQ QE~QS E X >".fl ~ SHEE I NO .:-;: 'INSIGN'XF'~'IGNIF I CANT I DE NT., 'g!). ll i~ T ~ NO ~ QLQ'a lHDL~~"'. G~MQTRY QT HER R~ARQS R C I C-'j>> VIiLl 1HV-0247 ACC NO RECORDABLE INDICATIONS R C I C-4r V I..H 1HV-0247 ACC NO RECORDABLE INDICATIONS RCI C-O'J2'3 VT5H 1HV-0252 ACC NO RECORDABLE INDICATIONS EXPANDED SAMPLE FOR RCI C-53 RCI C-" 5 V T "H 1H V- 0248 ACC SPR SETT INGS: N=1820 S=1720 NO RECORDABLE I NDI CAT IONS S PR S ETT I INGS ACC PER ENGINEERING EVALUATION RC I C-9( I >>>>l V T.~l! 1HV-0247 ACC NO RECORDABLE INDICATIONS

MNP-02 MASHINGTONTRPUBLXC' SUPPLY SYST EN INTERVA . 01 NON-DQS'QUCJI'Q'K'f'gl I ON SUNK AR Y TABLE PAGE 0 PERIOD- 03 S TSTg~~OR'j :C"gfl OkENT RCI~(gg-g DATE 08/20/93 OUTAGE: %8 OEL~Cgl'RP)!ON,'P,: 'OSPURP OJSCHARGE DRAWING NO ~ RCI C-20. EXAM ~ DATA E XAl'1 ~ SHEET NOggA'%> '('gggSIQ '%f%'IGNIF I C ANT I DENT ~ ~ NO ~ MTH>> HQx MIM@i"'"'iX "' ~:"-:. QKRMIEX QIHKR EXMR5$ 6RC IC (6) -1 VOL 1R I U" 052 %5 NO RECORDABLE INDICATIONS NO EXAM UPSTRH DUE TO TEE CONFIG HALF NODE CAL FOR SCANS C&D FULL NODE CAL FOR SCAN B

                                                                                                           ~ k<<

k k Sk

                                                                                                       . t      <<4    t  ~ '

Zf;

                                                                                                                   ~g <5 k

k TS pp Sf't kg ce.

VNP-OP MA SHI NG TON PUBL IC POME R SUPPLY S Y ST EH INTERVAL: 01 NON-DESTRUCTIVE EiXAHINATION SUN'R Y TABLE PAGE 001 ER I OD: 0 SYSTEM( OR ~CUHt'SHUNT HPCS(1) -0 DATE 08/20/93 OUTAGE: RH DES'CRIPTIOA".HTTH PRES C9RE SPRAY DRAWING 90 ~ HPCS-10> EX AH ~ 0 QUOTH DATA EX A N J'NQQ~IN .. ~~ jg'.~ EX AN ~ SHEET NO ~ ., - I N S $ GN.$ F: S I G N I F I C AN T IDENT ~ ~ MO ~ ~ B.Q. ~ ~QJ.fg~>> 'QQ~'"."-. G~EH~TRg ~Hfdf R~EARgS HPCS-PB- 101 ( L) V T-2 1VT2-93 ACC NO RECORDABLE INDICATIONS

WhlP-02 WASHINGTON PUBLIC SUPPLY SYSTEH INTERVAL. J 1 NON-DESTRUCT I VE,/gal'$1 ION SUHHARY TABLE PAGE 00 rERIOD: 03 S YST$ H,'OR;. 40HPONENT HPCS(9)-4 DATE 08/20/93 OUTAGE: 88 DES/RIP,740tif'ggQ+P~ Q~S~C~ GQ DRAWING NOe HPC -202 EXAM ~ DATA ~EX>> i~iZ~~~~ CX A~ SHEET NO .;i~-'.",~,. '-PI;PS E SIGNIFICANT 10E NT ~ e ht0 ~ H Tll ~ NO ~ '"ZHQLL~'~-'-=-.: t'f/'IMD'0>

                                                                                    %ME H~RQ /THE/      P~ARQQ 10HPCS(:))-1 VOL     1HPU-020    45                                                         NO RECORDABLE  INDICATIONS CIRC SCAN ONLY HPCS-31 V T3H   1H V-0247   ACC                                                        NO RECORDABLE  INDICATIONS HPCS-32 VT3H   1HV-0247    ACC                                                        NO RECORDABLE  INDICATIONS HPCS-33 VT3H    1HY-0247    ACC                                                        NO RECORDABLE  INDICATIONS HP C 8-34 V T3!l 1HY-0247    ACC                                                        NO RECORDABLE  INDICATIONS 4$

VNP- 02 MASHINGTON PUBLIC POMER SUPPLY SYSTEN IN TERVAL: 01 NON-DESTRUCTIVE,'-.E3f)HINATION SUNNAR Y TABLE PAGE 001 PERIOD: 0> SYSTE}I.OR COMPONENT HPCSj4)-1 DATE 08/20/93 OUTA GF.: R 8 D ES C RIP T;I O,N~.'-<~'S URALI ING 90 ~ llf CS 205 EX AH ~ DATA CX aaa jLA/LR/j;".' jR EVAN ~ SHEF;T NO -.. '-'~:".'-I NSI GhlXF~-' I GN IF I C ANT I DE NT ~ ~ ~'40 ~ HP CS-971 N i~i TH ~ M. ~QJ f,~" JQQ~ ~ '>": G f,QNQ~RY QT HE.R g~gR$ $ VT<H 1HV-024 7 ACC NO RECORDABLE INDICATIONS HPC S-I 2 V T,~H 1H V-0247 ACC NO RECORDABLE INDICATIONS VPCS-922N V T.'.H 1HV" 0247 ACC NO RECORDABLE INDICATIONS

I'NP- 02 WASHINGTON PUBLIC., SUPPLY SYSTEH INTERVAL. I1 MON- DESTRUCT'IllE:".EIt'A/I I ON SUN'R Y T ABL E PAGE 00 PERI OD: 03 ()UTA GE: R 8 S YSPKH'R, C0$ l.6FfgNT DE4cKJPTItrNo} Q}Q"PREs LPCS l g) cQR f sPRAY

                                                                                       ~                    DATE  08/20/93 DRAINING NO ~   Lt'CS-101 TEXAN.

DATA ~EAH~NQQ~IQ ' 'O LX A+I ~ SHEET <<"",.'q~,';::I.NSIGg Ppp SIGNIFICANT I UEMT ~ MO ~ NTH ~ NO ~ INDI ci', 'NDI'cd.-"'EoNETRY 0T HER R EMBARKS LPC S-13 V T 5H 1HV-0246 ACC NO RECORDABLE INDICATIONS LPCS-PB-101 (L) V T-2 1V T2 "93 AC C No RECORDABLE rNDrcATIONS "1

l"NP- ll2 MA SHI NGTON PUBLIC POME R SUPPLY S YST EH INTERVAL: 01 NON" DESTRUCTIVE;EXAHINATION SUHHARY TABLE PAGE 001 FERInD: 0 4 SYSTEHi'OR COMPONENT f PCS(1) -g DAT E 0 8/20/95 OUTAGE: QH DESCRIPTION ~,."L PCS-P-g DJSCHARGQ ORAMING VO ~ LPC"-202 E,X AH. DA TA EX~A~AT~Ilf-~RQJQTS E. X All ~ SHEET NO "-INSIGftIFi'IGNIFICANT I DE.':T ~ . 0 iITlI l'JO INDgf~ Jg~ge-' GEOHQQ~Y gTHER P~ARQS 16Ll'C" (1 ) -'~ T >'.4 5-9~-5e AC C T HI CK NESS HE ASUREH ENT UPS TR EAH OF Q ELD IN BLENDED AR EA

l"NP- 02 MASHINGTON PUBLIC SUPPLY SYST EH INTERVAL: 01 NON-DESTRUCTIVE E'$AHI T ION SUNllARY TABLE PAGE 00 I'ER I fiO: S YST;EN .OR"-,,COMPO ENT DATE 08/20/93 OUTAGf: 48 DESCRIPTION' '~C~QQP "A" UR A%i I:I "i NA ~ >~ HR -1 0 I E'X AVi ~ DATA EX~AN ~HATI N RE F ka>) ~ SHEET NO

                                                     '    '~' NSIGNIFi=        SIGNIF ICANT I DC NT ~ e'!O.              TH ~   NO  ~

RHR-2 c I <, > SUR 1RIIH-OT5 ACC NO RECORDABLE INDICATIONS PHR-y-4 I 4-BL T V T-] IRHV-031 4CC L I GHT SURF ACE R UST ~ NO APPAR ENT HATER I AL LOSS R HR -l':- I ' IL > VT-> 1VT2-98 ACC NO PE CORDABLE I NDI CAT IONS

MNP- 07. WASHINGTON PUBL IC POWER SUPPLY SYSTEM INTLf(VAi.: 01 NON-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 001 f ER I OO: ~ SYS (EH OR COMPONENT RHR ll )-4 DATE 08/20/93 OUTAGE: RO DESCRIPTI'ON -fQRgQP~C J,ggP "B" DR A W I N i-;J 0 ~ R ~!". -1 I 2 CXAH ~ DATA EX A ~N~A~IQ P~@'S SHEET NO I NSI GN IF. SIGNIFICANT I DEfi T ~ ~  ! (! Rf-If! -4tf."-( <<)

                     .                   "JO           IN Off'O/C       ~

S Uf< 1R HH -053 AC C NO RECORDABLE INDICATIONS I 4Lf'C I ( I ) it-4 VOL 1R HU-103 45 I 0 GEOHE.TRY RECORDED 90-180 AND 1 80-270 S ll< 1R flN-052 AC C NO RE COROABLE I NOI CAT IONS 14L f'C I f I ) 0-'i VOL 1RHU-104 ID GEONETRY RECORDED 0-90 OEG Sl!R 1R HH-057 AC C NO RECORDABLE INDICATIONS RHR-PB-102(L) V T-2 1 V T2-93 AC C NO RE COROABLE I NDI CAT IONS

0 0 S. N!'- 02 WASHINGTON PUBLIC SUPPLY SYSTEM [W)rrVhL: 01 NON-DESTRUGTIVE EMHI ION

SUMMARY

TABLE PAGE 0 ! LHI OO: C3 S YST EM'. OR C05P'ONENT RHRggg-4 DATE oe/20/e3 (iU7 h lp j DESCRIPTION: .RQR *SHUTDN CgOQ SUCT !) R h 4 I l ~ G 'u 0. !l!~R -1 ~)

                                   ~

XAv, ~

                                                                          ~RQ'Tg I DE  WT    .. cn.

E gh'P; MTL~

                                         ~

DATA SH!'.E T NO ~ NO, EX AM INDI I/AJ C ~ IOQ INSI GN'XF.'-. S I GNI F I C ANT INDICT'.. G EO METR Y OT HER REMARKS RHR -V-'i C-!!L T V)-1. 1R HV -030 AC C MINOR DEBRI ON FLANGE SURFACE 1<<L)" C I (1 i C-! VOI 1". HU-1 02 NO RECORDABLE INDICATIONS EXAM LIMITED BY VALVE CONF IG ~ SEE NOTE' 1'iL t'Cf (1 ) C-': S U)'R HM-0 54 AC C NO RECORDABLE INDICATIONS V OL 1R HU-1 01 I NTER Ml TTENT i 0-350 DEG y AT VARYING LOWER AMPLITUDE~ ID GEO SUE 1RHM-051 ACC NO RECORDABLE INDICATIONS

  ! HR-V-n> C-!!L T V  T-1     1RHV-034                   ACC                                   LIGHT SURFACE RUST NO APPARENT MATERIAL LOSS R>>R   "V-11 1 C-BLT V   T-I    1RHV-032                    ACC                                  L IGHT SURFACE RUST ~

NO A!'PARENT MATER.I AL LOSS RHR -)'-1 03 ( L) V T-2 1VT2>>9i ACC NO RECORDABLE INDICATIONS t

                                                                                                                  ~h"<)4RaSip>  .
                                                                                                                   ".'p,)5;Q'.P
                                                       )FLASK MNP- ff2                                                       ING TON PUBL IC PORE R SUPPLY S YSTEH I N T L l'. V A L: ff 1                               NON-DESTRUCTIVE EQAHINATION SUHHARY TABLE                             PAGE 001 P F ft I r>O ~ !> .5                                      SYST  EQ  OR   CORP ONENT         RKR (2 ) -4                DATE  08/20/95 OUT a    l.f.:                                            DESCRIPTION        ~HR'HUTDQ      COOL SUCT BRA~ I AC NO ~          R "ti( -I 0 s EX At~i ~

DATA LXhH ~ SHEET NO, g 'I NSI GN'IF'" SIGNIFICANT If)ENT VO ~ ."( ~ Ql 5Q= QI+OQ~, jgQJC

                                                                            "".'   jj+EiifTRY @THER    R+EARiiS PORHR(')

VOL 1R llU-1 10 45 NO RECORDABLE INDICATIONS S ltd 1RKM-068 ACC NO RECORDABLE INDICATIONS RKR-PP-)00(L) V T-2 1V T2-95 ACC NO R CORDABLE INDICATIONS

i.-i'IP np 5JASHI NGTON PUBLIC R SUPPLY SYSTEM 141f. I'VAL. (if NON" DESTRUCT I VE EXA)tl ION SUNN AR Y T ABL f PAGE 00 l f P 1 Ot): SYST EN OR, COHPONENT RHR (g) -4 DATf- 08/20/93 r:Urn(;E: DESCRIPTION iS~UTDQ CQQL, RET I P-A I.RA(J IIJ( JO. i iiR-I 0';, EX AM ~ I'LL:Jr DA TA LX~M ~ SHTE t NO INSIGNIF'IGNIFICANT

              ..'JO.                 8 THo     NO  ~         INDI C ~   INDI Co      GEOMETRY OTHER       R Et1ARKS R llP.  -5 n <<

VT3H 1H V-0246 ACC NO RECORDABLE INDICATIONS RHR -S A-'i ". V T.'iii 1H V-0246 ACC NO RECORDABLE INDICATIONS Plk(? -SA 'i'! V T,IH 1HV-0246 ACC NO RECORDABLE INDI CAT IONS

  ] 2R ilR    (  1  ) Ai-1  ',

VOL R HU -108 45 NO RECORDABLf I NDICAT IOI'JS SUR 1R HYi-058 AC C NO RECORDABLE INDICATIONS PilP -Sfi-xiii V T'.Aii lflv-024e Acc NO RECORDABLE INDICATIONS R fi R - 5 A i'. V'1 'o 1HV-E)246 ACC NO RLCORDABLE INDICATIONS R l)l? i A-'0 V T,5fI 1HV-024$ ACC NO RECORDABLE INDICATIONS P.i I R - S fi - 5 Y5 V T.'.H 1HV-0246 ACC NO RECORDABLE INDICATIONS 12i~ f'P. ( l ) A-l.5 V PL 1R HU-1i)'9 45 NO RECORDABLE INDICATIONS SUR 1R H"--059 AC C NO RE@l)(6ABLE INDICATIONS 12R ilP ( 1 ) A-14 VOL R-RB-136 5~60 RORY'".4glfgg)'EORI:YRY SUR 1RHP-neo ACC NO REC6RDABLE INDICATIONS RiiR -V-11 2 A-8LT VT-] 1R HV-033 ACC NO Ai PARWKT )if AT ERI AL LOSS

I NP MA S H I NGT0N P U BL IC P 0 ME R SUPPLY S Y S T E )if ItJff PVAL: Al NOf4-DESTRUCTIVE EXAMINATION

SUMMARY

TABLE PAGE 002 f'EP f,ifl: ! .'. SYSTEM OR COMPONENT RHR (1) -4S DATE n8/20/9b (IUTA;.P (u ~ DESCRIPTION;.~~HUTDQ CQO~~RT L,P-A I'f<AWING 'fO "l ~-13 "Y .-

                                                                        ',gpss]G .If>~ If>>

LX Ai< ~ DATA EX AM I AAT~I~~Egfj~TS

                             ~     JIW!'

[, I( i\ SHEET NO;C"': I NSI.GNIFP I'/~DC'",. r: S I GN IF I C AN T I DENT ~ ~ "f Or 8 Tll NOD INDI GEOHETRY OTHER R EMARKS fl flP -P H- I 0I) ( L ) V T-2 1VT2-93 ACC NO RECORDABLE INDICATIONS

0 0 i aASHI NG TON PUBL IC SUPPLY SYSTEM

)  g1;VAL:          i                                'ION-DESTRUCTIVE EXAMI       T ION SUMM AR Y TABLE                             PAGE no

')RI SYST EM OR COMPONENT RHR (g)-0 DATE n8/20/95 i=Urb i..': DES CRIPTI ON S HUTDQ COQUE RE T QP-Q ( )<At 1'.-. ~ ij ~ I iiP

XbY ~

DArA

                                          %Hat. T         NO         I NSI GNIF       SI GNIF I CANT I  bL-" t ~ ~   ~ "~                    NO   ~          INDI C ~   INDICT       GEOMETRY OTHER       R EMiAR KS 1
     "~(<R  ( 1':" )

V iAL 1RHU-107 65 NO RECORDABLE INDICATIONS 1R HM-051 AC C NO RECORDABLE INDICAT10NS 12>> ~'R< ) ) -I VOL 1RHU-105 45 NO RECORDABLE INDICATIONS c UQ 1R HM-055 AC C NO RECORDABLE INDICATIONS

   $ PRHP())i -          ~

V ('L 1 R HU-106 q5 NO Rf CORDABLE INDICATIONS 1R H8-056 AC C NO RECORDABLE INDICATIONS 1,"P <c~ ( 1) -1> LU') R-RB-1 1.~ NO RECORDABLE INDICATIONS 1RHP-067 ACC NO RECORDABLE INDICATIONS 120)'P ( l ) P-) > 1RHP-067 ACC NO RECORDARI E INDI CATIONS I PP <0 (1) ~'-I ~ VOL R-RB-112 60 45 DEG RECORDE D COUNT FRBORE G EOME TRY N0 ~ A g~.V AL V E S EEg(.OTE-.~I. S I DE DUE TO CONF I G ~ SUR 1B HP-067 AC C NO RECORDABLE I NDI CAT IONS "liP - V- I 2B-B LT 1 VT-l. 1RHV-02~ 4CC NO ~R.ECORl3'ABLE I NDI CAT IONS

   '(HP -( .'-106(L             )

VT-2 1VT2-<3 bCC NO RE.CDRD,ABLE I NDI CAT I ONS

                                                                                                                     ~ /
                                                                                                                 ~ 0

Wh!P- Ii2 WASHINGTON PUBLIC POWER SUPPLY SYSTEM I N7 I. l!V Al: NON-OESTRUGTIVE...;EXAMINATION SUMM AR Y TABLf PAGE 001 I'ERI(iu' > SYSTEM ORj COMPQNENT RHR lg) -P DATE 08/20/93 (OUTA bC: w l! 0 ES.GRIP.JP Ohl,'",~T~>SP~Y Tg ~RR Hgg$ ORAW IN(: "!O IIHR 20 I CX AN ~ DATA ~E~AQQAT~I ~ E 0 S I. XAM ~ SHCCT NO-:<j;; * ...IiNSI'gNXP;:-. SI GNIF I CANT I OC ~!T ~ IO ~ N Til ~ NO ~ INDI C~. INDIO~,~~ GEOMETRY OTHER REMARKS R t! R - I 'i '> VT <H 1H V-024 7 ACC NO RECORDABLE INDICATIONS I P R!-lR ( I ) A -4 VOL 1R HU-111 45 NO RECORDABLE INDICATIONS 1RHi'1-071 ACC NO RECORDABLE INDICATIONS IBRHH(]) A-'.. VOL 1RllU "112 45 NO RECORDABLE INDICATIONS SUR 1RHN-071 ACC NO RECORDABLE INDICATIONS R Hll - I 6i I V T,iH 1HV-0247 ACC NO RECORDABLE INDICATIONS I BR HR ( I ) A-l. VOL 1RHU-115 45 NO RECORDABLE INDICATIONS SUR 1R-HN-071 AC C NO RECORDABLE INDICATIONS AHI( - I C." V I SH 1HV-0247 ACC ,NO RECORDABLE INDICATIONS RHI( I j~< VT')H 1HV-0247 ACC NO RECORDABLE I NDI CAT IONS RHR -] I-4 ,a, h, V TDH 1H V-0247 AC C iiO'( .QIQQABL'E I NDI CAT I ONS VT3H 1HV-0247 ACC NO' INDI CAT IONS RHR-I BHl W) gt 1RHM-080 tE INDICATIONS 4'O SUR ACC @/gite Rl! 0 - I I<H VT "'l 1HV-0247 ACC I NDI CAT IONS Rl:,ll-'~ 7gg< V T 3H 1H V-0247 ACC No Rppg 'QL:E I NDI CAT IONS

                                                                                                                "~r~ 'e~K=

l!A SHI NGTON PUBL IC R SUPPLY S YS T EMi X<ON-DESTRUCT I VE EXAM ION SUMM AR Y T ABL E PAGE 0 f j.>>f!P: SYSTEM OR COMPONENT RHR(l )-2 DATE 08/20/95 (il!Th'f: 4 DESCRIPTION: STN SPLY TO RHR f(Xya <<:f< <<"<<!. f!i' g AM DATA C '(5<<; ~ SHEET NO I NSI GNIF S I GNIF I C ANT r~ f.i <<'!0 e INDI C ~ IQDIC ~ GEOYiETRY @THER R f MARKS V!f 1RRU 1 2<< NO RECORDABLE INDICATIONS Sl,li. ) Pi<Pi "079 ACC N 0 R E COP DAB L E I N() I C AT I 0NS

<'NP- 02 IJA SH I NG TON PUBL IC POME.R SUPPLY S YS TEN INTf.kVAL: 01 <<<ON-OESTR0( T I VE-"8:)('AHINATION SUfIH AR Y TABLE PAGE 001 f'ER I OO S YST EffvWR:C,OQP>ONENT ~lR HR (4 ) -g DATE 08/20/93

               'UTAGE:

DESCRY,P<TE 0 '..~l'~TgST Qggg f,g OP A DRAW IWG NO ~ "'HR -205 >,g><<<)g&.-;<~-

f. X Af) ~

DATA CX~A+~~t(g" ' f )<AN ~ SHLET NO;" .'", 'NSZGR< ..< SIGNIFICANT I Of: hT .'.) 0. ><< T!?~ Nn Qw ~NOjg~ ~ gggg~~- G EONQQQ Y //HER R ~ARQS f? I I R ->f 1 't ( ': ) Sf)R 1R f? fi -061 AC C NO RECORDABLE INDICATIONS RHP -4 I <~ V I <fl 1HV-0247 ACC NO RECORDABLE INDICATIONS f<l?R-4'-'0( ') BUR 1R HN -060 AC C NO RECORDABLE INDICATIONS

0 i'NP- Ot WASHINGTON,PUBLIC SUPPLY SYSTEM l)JT Lf? V~L: i'1 NOth-DESTRlJCT5<'VE.'.E.X')MIN ION SUMM AR Y TABLE PAGE 00 f-l. R I r~U: SYSTEM, OR',"QOHPOAENT 20RHR (2)-2 DAT E 08/20/95 f.'U T A e-f: 0 8 f >le A'd l l'J (i 'J u l: HP -" 0'r EXAM. DATA EXQNQN~A~IN -~E'. S g la<" ~ SHEE I NO ".';:..'INSIGH/F.."'. SIGNIF ICANT I I!I JJOo INDICINDICC%9~ GEOMETRY OT HER R EMAR KS i Ufe 1RIlM-064 ACC NO RECORDABLE INDICATIONS 18f?ffR(p) A-j~ VOL lRHU-117 45 NO RECORDABLE INDICATIONS SUR 1R Ilv."0 6') AC C NO RECORDABLE INDI CATIONS "4le 'l '." ) 4-7 VOL 1RHU-116 45 NO RECORDABLE INDICATIONS SU;e 1RHM-063 ACC NO RECORDABLE INDICATIONS R I I fi -'j l f 'i' V ) Sl)"". 1R HM-0 72 AC C NO RECORDABLE INDICATIONS

  ? 4 f? HR (       " )  ~ - 'e VOL         1R  kfU-115      45                                              NO RECORDABLE INDICATIONS SUR          1RHM-069         ACC                                            NO RECORDABLE INDICATIONS V  t'l       1RHU-114        45                                              NO RECORDABLE INDICATIONS SUR          1R HM -070       AC C                                           NO RECORDABLE  INDI CATIONS

N'I'I I'- 0 7 WASHINGTON PUBLIC POMFR SUPPLY SYSTEM JNTI. OVAL: I)1 NON-DESTRUCT IVE E)tAMINATI ON

SUMMARY

TABLE PAGE 001 I'CI? l PO: SYSTEM OR COMPONENT 20RHR (8) -2 DAT E 08/20/93 I!UTAH(',O E>>(r;- DESCRIPTION 'HQP CS CROSS T I E OR AM l!uG I,, ~ EXAM. DATA EXAMQN~TIIN BEQQQQ

                 .'. J V A,f( ~ SH EC'T             NO   'NSIGNIP,            SIGNIFICANT I I.'L I'T                        -'". T!!~     i') O ~

2 II I?!I!( ( > > Ai Vi L 1R HU-125 95 NO RECORDABLE INDICATIONS 1R I-;I< -07',! ACC NO RECORDABLE 'NDICATIONS I (( (I W i? I:< S h - ( VIAL 1RHU-118 45 NO RECORDABLE INDICATIONS 1 R I!M! -0 7 3 hC C NO RECORDABLE I NDI CAT IONS V l '! I HV-0247 ACC NO RECORDABLE INDICATIONS "I!!' l 3l V T.<!! 1H V-0247 hCC NO RECORDABLf INDI CATIONS I? I!R -43.( VT3(I 1HV-026 7 ACC NO RECORDABLE INDICATIONS 2!((? ((P < -) h VOL !RHU-12'( 45 NO RECORDABLE INDICATIONS 1R HU-1 25 45 NO RECORDABLE INDICATIONS SUPP L EM ENTAL FULL. VOLUME E XAM 270-315 TO SUPPLEMENT MT EXAM SEE REPORT 1RHM-077 SUI~ 1RHM-077 REJ 2 70>> )ilgwu'INEAR 5~3 X o1 IND'i ')Yig@."~IS BROAD AND FUZZY'XAM IgOg!/APT AND UT NO RECOMOAI(+~XNDICATIONS ~ THESE ADO-ITI5k)It "g AHS VERIFY THAT HT INDI!(gi(lt(.FIS NON-RELEVANT~

                                                                                                                      'I( '(-'p '8

WASHINGTON PUBLIC R SUPPLY SYSTEM NON" DESTRUCTIVE,EXAMI T ION SUMMAR Y TABLE PAGE 00 S YS 7 EM OR COMP (i@EN T 20R MR t g ) -P DATE 08/20/93 EX ht4 ~ DATA EQ~AQQAT~Q-"~l+f JS E <AH ~ SHEE T NO,l- ".,>>,">I Q S I,NI1 I Fe..

                                       ~

S I G N I F I C AN T 10C!IT ~ ~'L Tl~o NO ~ INDI Ce~'hlD~Ce'.~b'.; GEOMETRY OTHER R EHARKS 1 RHP-069 ACC NO RECORDABLE INDICATIONS~ SEE REPORT 1RHM-077 ~ VT~H 1HV-0247 ACC NO RECORDABLE INDICATIONS VT ':l 1HV-02cl7 ACC NO RECORDABLE INDICATIONS 0HR -'.i!. VT.'>I lHV-0247 ACC NO RECORDABLE INDICATIONS

PNP- 02 WASHINGTON PUBLIC POWFR SUPPLY SYST EM INTE RVAL: 01 NON-DESTRUCTIVE EXAtIINATION

SUMMARY

TABLE PAGE 001 ~r.RI On: S YST EM OR: COMP ONEN T RHR l1 )2 DAT E 0 8/20/93 OUTA( E: DESCRIPT'ION; ~OP B SPLY-RHR HXQB I>PAW III'O.::.'l~:- 0 ~ EXAM ~ DATA EX AM J,Q~A~IQ ~RE ~U-'>TS I. X:~ ~ SHt 1:T NO .I NS I GN IF- S I GN IF I C AN T 1DE <'T ~ 'JC ~ M 1I s'

                                               ~

0 liR -'> I i"..I I .-

                             }

1RIlM-065 ACC NO RECORDABLE INDICATIONS R>IP )P Ii'i < -.') SUg 1R Hi I -001 AC C NO RECORDABLE INDICATIONS Ikt)Q -4 V T~il lHV-0247 ACC NO RECORDABLE INDICATIONS f( > IP - i) 'i ') VT '.ll 1H V-0251 ACC I NT LR F ER ENCE WI TH SHI ELO WALL E VALUAT ED AS ACCEPTABLE ~ SNUBBER STOKED AND FOUND OPERABLE R I IR cl ~' - (;<) S Ui' 1R HM-0 66 AC C NO RECORDABLE INDICATIONS lIIIR -n "0 T.<ll I HY-021' ACC NO RECORDABLE I NDI CAT IONS R IIP -~t'< t. V I,'ill 1HV-0297 ACC NO RECORDABLE INDICATIONS RHR-~ i7 Y T.<l I 1HV-0241 ACC NO RE CORDABLE I NDI CAT IONS P)IR-18'>( SUR 1RllM-Ob 7 ACC NO RECORDABLE INDICATIONS PIIP -214( W) Hi I -0 P HP 1 ~l. Ii I W ) 1 R 62 AC C No R

                                                                                                                         $ 0IHiABLE I NDI CAT IONS SUR        1R IIM -0    65   AC C                                                                     I NOI CAT IONS
>.p~"(

'<<Nf>>- Il? WASHINGTON PUBLIC SUPPLY SYSTEfl

]NTERVAI .                                        NON-DESTRUCTIVF,'XAHI         ION SU f)M AR Y TABLE                      PAGE   0 f:El)] OD:                                            SYSTEM   OR C,OHPOJENT        RHR (J,)-2                         DATE   08/20/93 OU]AGE:                                               DESCRIPTIONLdt)P C/LP CI RETURN BRA" I Nf: )0 ~ ".)IP,-2] 0
                                                                    ~ ikt g T. XAN ~

DATA EXANINATiION RESUL'TS I: X Ai)i ~ SHEET NO . INSIGNXF." .SIGNIF I CANT I UE f! T ..'J)). '~i TI< NO ~ RH)< -3;>3 VT lH 1HV-0247 ACC NO RECORDABLE INDICATIONS R)lR -1 0,= I '3 V T.~f< 1HV-0247 ACC NO RECORDABLE INDICATIONS RH)1 "3i"". V ].'iH 1H V-0247 AC C NO RECORDABLE INDICATIONS P.) IR -.5." 1 V T.'i) I 1HV -024 7 AC C NO RECORDABLE INDICATIONS f! IIP -3] I VT lH 1H V-f}247 ACC NO RECORDABLE INDICATIONS R)if) 'i)) ~ y] 5)! 1HV-0247 ACC NO RECORDABLE INDICATIONS P l)R -302 VT'iH 1)ly-0247 ACC NO RECORDABLE INDICATIONS RIIR -5" 1 VTSH 1HV-0247 ACC NO RECORDABLE INDICATIONS ft ) t - '.' P. VT'aH 1H V- 02'I I AC C NO RECORDABLE I NDI CAT IONS R ) IR ,"" v VT'>H 1H V-024 7 ACC NO RECORDABLE INDICATIONS 0Hfl -3,"4 V T3H 1H V-0247 ACC NO R,

  • QhDABl E I NDI CAT IONS RHR-33 7 VT3)l 1HV-0247 ACC NO R 6tb@LE I NDI CAT IONS 8 II)'. -35)l V T3iH 1H V-024 7 ACC 5 I NDI CAT IONS R))R-O r3'i V T3>I 1HV-0247 ACC NO.'f/'548l'E I NOI CAT IONS P IIR ->7 "N VT lH iffy-0247 ACC NO RK(OgpkpLE I NDI CAT IONS

L'Nl'- li2 'WASHINGTON PUBL IC POMER SUPPLY SYSTEM 1'J] L >" VAL::}1 >>l O N- DESTRUCT I VE EX/MIN AT I ON SU HN AR Y T ABL f PAGE 002 i > E R ] (! f}: S YS TEN'R COMP QNENT RHR ( 1 ) -2 DATE 08/20/95 (UTArl: DESCRIPTION'gP C/QPCI RETUFN IJR Al>> f t>>(. t! 0 ~

                                " i'l. -." 1 0
                                                    "}iA'l ~

DATA t.XQH I NAQ~IN ~E+Qgf V SHEET NO INSI GNIF S I GNIF I CANT I ljL t T,,

          -'54' l>l ~               I'li  ~                     INQgg~     IND~Ci RI.IR VT4H     1HV-024   7       ACC                                             NO   R E COR DABLE     I NDI CAT IONS P  t]R    )4 V T.~H   1HV-0247          ACC                                                  R E CORDABLf. I NOI CAT IONS R lg R -~   'g '. ~

VT >H 1HV-0247 ACC RECORDABLE 1NDI CAT IONS PHP ->>4p' V T cH 1H V-0247 ACC RECORDABLf. INDI CAT IONS RHR-$ ccci V T,='i IHV-0247 ACC NO RECORDABLE INDICATIONS

   ] 4RHR ( l )         C-]

V OI ]RHU-100 ACC NO RECORDABLE I NDI CAT IONS SU~ ] RH>>]-049 ACC NO RECORDABLE INDI CAT IONS RHP V T>H lHV-0247 ACC NO RECORDABLE I NDI CAT IONS V ThH 1HV-0247 ACC NO R E COR DABLE INDICATIONS

   ] 4 0 I IR ( l } 0        !,

VOL ]RHU-0 i9 45 NO RECORDABLE I NDI CAT IONS SUR 1RH'l-050 ACC NO RECOR,DABLE I NOI CAT IONS ft Hp -9lc ..@4jfgI'.'q V T '>H 1H V-0247 AC C No >ch'ijiiiijjjaL'E I NDI CAT IONS FVR-ci 7 VT~fl 1HV-0247 ACC NO R04QR54¹LE I NDI CAT IONS RHF. -96 VT >i< 1HV-0247 ACC No RES]>R)KALE I NDI CAT IONS RHF 9c) V T.>H 3 HV-0247 ACC NO fCQCD,R.D.ABLE INDI CAT IONS

0 } NP- 02 MASHI NGTON. PUBI. IC SUPPLY SYST EYi Ih}Tt f<VAL: 01 NON-DESTRUCTIVE EXAHI ION SUNH ARY TABLE PAGE 00 f'ER I 00: SYSTEH OR COHPONENT RHR lg)-2 DATE 08/20/95 nurAGE.. ~8 DESCRIPTION L~Ofl C/LPCI RETURN f}RA}'ING NO ~ }.:<p EX Al', ~ f)ATA EXAR~N~!I?ON .R~ESU TS SHEE T NO .:

                                                       '" INSI'GN!XF,'.         SIGN  IF I CANT jbj 0 ~           I N 0$ C   ':"'IQQ~C'o -'}"'. QQO H g TRY  g HE R T         RBHARgS V T3ll   1HV-0247         ACC                                                   NO RECORDABLE   INDICATIONS 8 I If} -9  '.}

1HV-0247 ACC NO RECORDABLE INDICATIONS R<<llR -9 1 V f 3'I 1HV-0247 ACC NO RECORDABLE 1NDICATIONS R H }} -'l 9 ' VT <<}l I HV-0247 ACC NO RANCOR DABLE I NDI C'AT TONS VT '<<H 1H V- f}P 47 ACC NO RECORDABLE INDICATIONS VT 4H 1H V-0247 AC C NO RECORDABLE INDICATIONS Riff}-99 7'v V T,W I HV-0247 ACC NO RE CORDABLE I NDI CAT IONS R}hg -320 VT3ll 1HV-0247 ACC NO RECORDABLE INDICATIONS

}.'}JP rl'> WASHI NGTON PUBL IC POWER SUPPLY SYSTFM I r g TfAL t>UI AQL: 1,>i! 'l J NON-DESTRUCTIVE EXAMINATION

SUMMARY

TAB} F SYSTEM .OR COMPONENT DESCRIPTION: R~R<<P-2C SUCTggN RHR (2):1 DAT E PAGE 0 001 8/20/93 }?r} AW I "> '. 'I f XAM ~ I?A TA EX AMQNAJ~IQ~ESUJ..TS E r,"} ~ SHEE T NO i' - INSIGNIF' SI GNIF I CANT I DL l! T o.>:Oe 1}t~ NO IN OQC ~ ' NOI Ce~ EO METR Y OT HER R EMARKS 74R}lP,

                ~

( '. l- ~ VOL 1R}lU-121 45 NO RECORDABLE INDICATIONS R hrl ( ~

                      ), /3 ( I 7)

SUR Ui: I 1%HM-075 1RHM-074 ACC ACC NO RECORDABLE NO RECORDABLE INDICATIONS INDICATIONS R Hl( -') r'.i V T,iH 1HV-0247 ACC NO RECORDABLE INDICATIONS P HP cg g f; 'l< V T S}l 1H V-0247 ACC NO Rf CORDABLE INDICATIONS Rfif'-4 7 VT 'll 1HV-0247 ACC NO RECORDABLE INDICATIONS 74F llk ( )) -(I V Ol. 1Rf}U-120 45 NO RECORDABLE INDICATIONS S U IP 1RHM-075 ACC NO RECORDABLE INDICATIONS Pf}P 4 c VT <H IHV-0247 ACC NO RECORDABLE INDICATIONS 24 fl f}r' c VCL 1RHU-119 270-360 DCG 75K DAC ROOT GEO

           - I', 'g S U'(       I RHM  "075   ACC                                      N0 l,  ')Pj0              BLE INOI CAT IONS P. } l0    <?

VT 3H 1HV-024 7 ACC NO 'g5 L'E I NDI CAT IONS V T3r( 1H V-0247 AC C NO W 6, LE INDICATIONS P}ll> 1 gc) :I

                                                                                                              }  g)8ggfl:

VT:>ff 1HV-0247 ACC NO Spic QI$IL,E INDICATIONS V T3}l 1H V-0247 ACC NO kgCl}~ABLE INDI CAT IONS

                                                                                                             -'-'a/

1 ", . fa + j;

I "IIP- Ef~ MASHINGTON .PUBLIC R SUPPLY SYSTEM I NTf. I>YAL- 01 NON-DESTRUCTIVE'XAHI ION

SUMMARY

TABLE PAGE 00 q I <If) R.z SYS,.TEH OR:.CONP.. MENT RHR lQ)-1 DATE 08/20/93 OUTAGE: ~~ DE,SGRIP,TISH i '.-P-PC SUC~T URAV TNT

f. X Ail ~

jjgj~A jjjj"~~Sj,~s I DENT ~ ~ "4'I ~ E HT IE III ~ f~ DATA SHEET iU0 ~

                                                  ~E NO,." ji;.> p<',,

THOTC','llOJC4>C,. ANSI G $ F.<'I GNIF I C ANT GEOHETRT OTHER REMARKS II I.IR -3'> YT 'ifl 1HY-0247 ACC NO RECORDABLE I NDI CAT IONS P IIII - 5" V T 'ii) 1H V-0247 ACC NO RECORDABLE I NDI CAT IONS RIIR -37 VT 'H 1H V-0247 AC C NO R E COR 0 A BI E I NDI CAT IONS

  'I llg -g I YT    TH   1H V- 0247     AC C                                                NO R E COR 0 ABLE    I NDI CAT IONS RHI>    -~i0 Y T.'H     1HV-0247      ACC                                                  NO REOCRDABLE        I NDI CAT IONS VT   "II   1HV-0247       ACC                                                 NO RECORDABLE        I NDI CAT IONS V T:hH      1H  V-0247    ACC                                                 NO R E COP. DAB L E  I NDI CAT IONS

~'Nt'- 02 MASH I NGTON P UBL IC POME R SUPPLY S YST EM IN I F. I'. V A I: ON- DES TRUCT I V E EXA MIN AT I ON

SUMMARY

T AOL I PAGE 001 I'f I? t.'ft; 1 o '~ SYSTEM OR COMPONENT 'HR (16) -1 DATE 08/20/93 fIU T A GE: 3 t< DESCRIPTION '.~CO 0 MODE SUPPLY ORAM1NG NO. =

                           .R-; I:.                                                 j
                                                                         )ii"+.<"J." i'
.X Aft ~

DATA EX .'f. SHEET 1 Uf. IIT ~ .'4)) ~ HTH ~ WO+ f'lip - T.- t VT JH 1 fi V-024 7 ~ AC C NO RECORDABLE INDICATIONS RHR-3 t I VT;H 1HV-?f247 ACC NO RECORDABLE INDICATIONS R ftt? -3C.7 VT~rl 1!I V-0247 ACC NO RECORDABLE INDI CAT IONS Pt-If'. - <~ > 1HV-02it7 ACC NO RECORDABLE INDICATIONS RHP -394 VT5tl 1HV-0247 ACC NO RECORDABLE INDI CAT IONS

WAFT 02 WASHINGTON PUBLlC . SUPPLY SYSTEM 1fJTF.OVAL: 131 NON-OESTRUCTIVE'EN/HI ION SUIIHARY TABLE PAGE 00 f':f<1 rfU: SYSTEH~(OR". COHPtgl NT RHR j28)-1 OATE 08/20/93 fIUTAriE: QFA, OESCR1PTION,':YfiffR-'HEAT rxCHAQGE gA f.'fiAW ltfi !JO.,Aire -216 F XAH ~ DATA EX~A+/~A EX AT'l SHEET I UE iiJT ~ ~ FJO ~ TH~ NO Rfff(-IfIT<<'J V T5!f 1 ffV-02rf7 ACC NO RECOROABLE INDICATIONS

',NI'- WASHINGTON PUBLIC POMER SUPPLY SYST EN lIP'NTf.!OVAL: 01 NON-DESTRUCTIVE-EXAMINATION SUNHARY TABLE PAGE 001 I'LII I "D: .I.5 SYSTEM .'OR COHPONFNT RHR t 28) -1 DATE Oe/20/eS OUTA':: ~II DESCRIPTION 'RH HEAT gXQHAgQQ QA Dl'Ali I ~IG:I,".. ~ I-. : Pn EXAM ~ I LL 'i T ~ ~,II'

                                     ;-. X i" T AM I

DATA SHf NO ~

i. I NO 'i'NSI EX AH~N~A~IQ R EfQ,"TS GN IF! S I GN IF I C ANT IIIIP -9~< ',,I'x VT <iI 1 H V- 0 2 0 7 AC C NO RECORDABLE INDICATIONS RHP -~N'<'v V'T!I( 1HV-0207 ACC NO RECORDABLE INDICATIONS RI-If! -'!.C'> ~

V r:.II IHV-02< 7 ACC Nn RECORDABLE INDICATIONS

  ~                   ~

ll'-02 MASH I NGTON PUBL IC R SUPPLY S Y STEM l NTL:fVAL: 'll '!Of!-DESTRUCTIVE EXAMI T ION SUMM AR Y T ABLE PAGE 00 '.Rl Ol]- l'.*r SYSTEM .OR COHP5NENT RHR (28) -1 DATE OO/20/85 ()U TA(:E: DESCRIPTION !Qg /EAT EXCHANGE gA ffRAW lfi~G 'qA, Rl P . gp E.X AM ~ DATA EX i'ig ~ S "l EE T If)F l'l ..'~" 0 ~ Vgr.f NO ~ Rf-fr<-Pn iaaf ig /p 1H V-024 7 AC C NO RECORDABLE INDICATIONS

hIP- *'i 9 WASHINGTON PUBLIC POMER SUPPLY SYST EH I N T I. 0 I NON-DESTRUCTIVE .;EXAMINATION

SUMMARY

TABLE

                  ~
                      ~a~

I PAGE 001 I'EP I nt): 0 ~ SYSTEM) OR COMPONENT HS(1) -4 DATE 08/20/93 OUTA(l: DESCRI)TION';JAIL STEAH QINE A I;RA'NG '(O ~ QI.5::% EX AM ~ ~t DATA EX AQ J N$ g~Q ~Ef"$ S E)l ~ c')(ED T NO .'. - I NSIGNIF, SIGNIF I CANT

'IDENT ~       ~   I"                    7 II ~    '4A ~          ggJQQ~       QQQQC  ~  'EQMQ7R~        gTLtER REMARKS pgy!: ( ] ) h-! /:( "4b -4 fi V (il       1  IRSU-0 78   45                                            NO RECORDABLE    INDICATIONS 1HSM-045       ACC                                           NO RECORDABLE    INDICATIONS P b S     ( I ) .". -'     <i:.) S (' 4 I VOL          1MSU-079      45                                            NO RECORDABLE    INDICATIONS 1  HSM-045     ACC                                           NO RECORDABLE    INDICATIONS V T ~'<     1HV-0246       ACC                                           NO RECORDABLE    INDICATIONS MS I! h    ;

VT ~II '1 H V-0246 AC C NO RECORDABLE INDICATIONS MS- V-'.."A -'ILT VT-1 1HSV-150 ACC L I GHT SURFACE RUST ON NUTS NO AP P AR ENT HAT ER I AL LOSS vS- V-;i><h-!(LI V I-1 1MSV-145 ACC NO RECORDABLE INDICATIONS MS-I B-I 1(L). VT-2 I VT2-93 hCC NO RECORDABLE INDICATIONS

VIP- 02 MASHINGTON PUBLIC SUPPLY SYSTEM 1NTERVAL: 01 NON-DESTRUCTI YET EXAMI ION SUMM ARY TABLE PAGE 0 f'ER I OD: SYSTEM,.OR COMPQN'ENT MS(g)-4 DATE 08/20/93 ( UTAGE.:

                      ~ S-DES,CRIPTI        ONNe" ~~ST/ AQ     Qggg     B D R A bl I NG 'Tf 6 ~       ]92 FXAN ~

DATA EX AlfI~AT~I

                             'AM       ~ SHEET         NO  ";, '<', '- I NSI GNIF~"    S I GN IF I C ANT IDE Nr     0,"             M TH ~      iVO ~         INDI C',:."gli[~OC'""if"'. GEOHETRT     OTHER   R EMARKS MS V T '.,'i   1HV-0246      ACC                                                NO RECORDABLE INDICATIONS RR I   I H V T.'H      1HV-0246      ACC                                                NO RECORDABLE INDICATIONS Hi ..D SUR          1M SM -039   ACC                                                NO RECORDABLE I NDI CAT IONS MS-i't-] "P f i V r-2        1VT2-93      ACC                                                NO RECORDABLE INDICATIONS

'r'IJP- O~ WASHINGTON PUBLIC POMER SUPPLY SYSTEN JtJTLIiVAL:  !) I NON-DESTRUCTIVE-:E'XAHINATI ON SUAN AR Y TABLE PAGE 001 1'f k t <'I) ' S YSTEH OR CO,MP:OhlENT MS l 1) -0 DAT E 08/20/93 IJ 'T P c': .H DESCRIPTIt)N:, ~H STEaH ~ME C I>R Ai;, t q c, ')

                                    'A'4  ~

fiATA E X AH J, N$ T I 0 N. Q Egg',"gg I XIV' SHIET NO I'NSI GNIF SIGNIFICANT I DE NT ..'IO. Ii T'l ~ HQ ~ ghfDJgp $ QQggo'=-. G~ENgTRg @THER R~EARQS HS-I'I!-1'.I '. t I ) V T-2 I V T2-93 AC C NO RECORDABLE INDICATIONS

0 (-' P - () 2 MASHI NGTON PUBLIC R SUPPLY SYSTEt( VAL. 01 T I ON SUNHARY TABL E PAGE

                                                                                                      ~

list TE r. NON-DESTRUCTIVEPE'kAH 0 )'ER I OD: SYS'TEH;OR'COttPOhlENT HS(1> -4 DAT E 08/20/93 (>uTArE::~!! DESCRIPTION.: STEAV LINE D t>RA" ING NO "'S-1 0<<

                                                                                ',8~g CXAM OAra               ~EX   Ng               '-~EQgS CX    <'i~) ~   SflEET             Nd'.     '.-.?.'".liI NSX.GN'IF. S I GN I F I C ANT 1DE tpT      . ~ ",.'>.              t>T"            llO ~

ivO 2 0tt 8 ( 1 ) Oi - 7 / 'i Y-S 1> << f: V Ol. 1MSU-083 f5 NO RE COR BABLE I NDI CAT IONS 2 (i.": ( 1 ) -'- ~ /'( " ".- cUR gl 1vi Yi-047

                                                           ~ictus ACC                                                     NO RECORDABLE             I NDI CAT IONS V             ~ 1t1SU-082          45                                                      NO   R E COR 0 ABL E      I NDI CAT TONS S Uf<            I          047    AC C                                                         RECORDABLE           I NDI CAT IONS 26">.'       j ) '>-Yi'< ")SR-c". ci VOL              1MSU-081          45                                                      NO RECORDABLE             INDI CAT TONS
                                        'S 1'R           I tkSt>-047       ACC                                                     NO RE CORDABLE            INDICATIONS 26  ~   ~  ( 1 >D     7/8'R          IU VOL              I NSU-080         45                                                      NO RECORDABLE             I NDI CAT IONS bUR              1 t5 St~i -0 47   AC C                                                         RE COR DAB LE        I NDI CAT IONS 2i-t" 8 (    1 >:>-hi V(>L             1NSU-085          45                                                      NO RECORDABLE             INDICATIONS 8 ltp            1 i'1 St( -0 50   AC C                                                    NO RECORDABLE             I NDI CAT I 0NS "G."8(])O-8LDI VOL              1HSU-087          45                                                      NO. RF COR,O)Q LE INDICATIONS fgip $ ~'I/Q'O SUR             IHSYi 050         ACC                                                          KE45Rj)+LE I NDI CAT IONS Pr  t'. c(  1 >  D-BLDO VOL             1t>SU-086         45                                                      wo'ii68(RP)BLE INDICATIONS SUB             1>>S<-050          AC C                                                                             I NDI CAT TONS 26"t "(1 ) U-9LUI V  Ot           I H SU-090        <<5                                                      No @Cbg              B,LE INDI CAT IONS

02 WASHINGTON PUBL IC POMER SUPPLY SYSTEM 1NTE:itVnL: UI )YON-DESTRUCT I VE;-;EXAHINATI ON SUHN AR Y TABI E PAGE 002 i'lf R 1 ()D ~ SYSTEH OR COHPONENT HS(1) -4 DATE 08/20/93 ()UTA.")E: ~8 OESCRIPTIOQ ~H: STEAQ L,INf Q 1'RnuiNG '=(. E XAH ~ OATA EX AH if~A'TI g ~RS~ Exn~ ~ SHEf. T NO.'. INSIGHlF, SIGNIF I CANT I DE l'T .. ':0 ~ N Tll~

                                                      'G
                                                             ~ 0 I Q~  ~  '$Q~~<)->>. G EO MfJ R Y g$ HE R R f; H A R K S SUB        INSM-051        ACC                                         NO RECORDABLE             INDICATIONS 2 GM    ".  ( 1
                  'l i -",. L!EO VOL        1NSU-0 89       45                                          NO RE COROABLE            INDI CAT IONS 1NSM-051                                                    NO RECORDABLE             INDICATIONS 2 6 t)) 8 (    1 )  '".                                      ACC Vl L       1NSU-088        45                                          NO RECORDABLE             INDICATIONS w

UP 1MSN-051 ACC NO RECORDABLE INDICATIONS V E <H 1 t! V-0246 ACC NO R E COROABLE I NDI CAT IONS M.'>-ill)-,"(-:) S Ul> 1NiSN 048 NO RECORDABLE INDICATIONS M< l:E) V r."li 1H V-0246 AC C NO RECORDABLE INDICATIONS MS-.':E)-1 VT '>I 1HV-0246 ACC NO RECORDABLE INDI CATIONS V T."! ~ 1H V-0246 ACC NO RECORDABLE INDICATIONS 2 o l" -') ( 1 ) ' 1() ~ p VOL 1NSU-084 45 NO j,:CORDABLE INDICATIONS SU)i 1MSN 049 hCC INDI CAT IONS

          '"-LU"'. D     HEA D D SUR        1MSN-040        ACC                                         NO     R6 QIANA L'k INDICATIONS 2 () Mi ".. ( 1 ) O -1 7                                                                                       Q9'q         ,.-

VOL 1M SU "07'l 45 NO .Q BL'E INDICATIONS MS- V-2'!!)/2NS (9 )-4 ~'t i) SUR 1NS'1-041 ACC NO 'Rkg,t)S,,SL'E I NDI CAT IONS

i'NP 0~ MASHINGTON .PUBLIC SUPPLY SYSTEM INT! RVAL: 0] N0 N- DES TR U GT I V E" EX'A+I I ON SUMM AR Y T ABL E PAGE 00 Pf SYSTEM, OR <<,CO+5 (NT MS(1) -0 DATE 08/20/93 RIUO'UTAGf.: OESCRIP.T.:ION, ='A STE AM LINE D ]>RAN ] r/0:uO ~ "'].' ] 0i) EXAM+ OATA EX AMI NATION'ES~V-TS

                                 ! XAQ ~  SI]EET      eo  .:-..-" i..P.NSXeiXF>r       SIGNIF I CANT ILffJT    ~ ~ u~'              i~c T!C ~ r>0.        INOIC~       . QQD~C"     .'jCQ METRY    OTHER       REMARKS
 >S-Pt)-)      "<> (L ]

V T-2 ] VT2-93 ACC NO RECORDABLE INOI CAT IONS

t ttP- (> VASHI NGTON PUBLIC POWER SUPPLY SYSTEM f t>ILRVAt: r;l t~rN-DESTRUCTIVE.EXAMINATION

SUMMARY

TABLE; PAGE 001 I'f F I '.tD: 0 SYS/E) ~OR COMPONENT MS(9) -4 DATE 08/20/95 OUTA GE: DES CftjktION'~SVALVE DRAINS Dt~hv[ttr.;<n. <<.8- t ft, EX Atl ~ .

                                                                                   "TS
                                                               '.()e.'-'XAMINATION DATA                          ~ES SHf ET        NO  -'j" $ . INSIGNIF!                      -SIGN IF ICANT I t.'f t T ~ ')O ~         Nn.

t'S- f'ft- 1 " ( L )

               ."~

v f-> l V T2-9;5 ACC NO RECORDABLE INDICATIONS

v.nSV- 02 MASHINGTON PUBLIC,, R SUPPLY SYSTEM ] "1 1 E. RVA l.: 0 ] NON-DESTRUCTZYE+E)tAMIN T ION

SUMMARY

TABLE PAGE 00 1"( R]()D'UTAGE,: SYSTEHr.OR'OUPON'.ENT MS(~)-f DATE 08/20/93 DESC,RIPTI0,tl) p~d'>aRX YES HEAD VENT 1)RAIJ]f~.('lO. IS- ng 1 EXA~. DATA EX AN J SAT ~ It N I ILES~0gS E. X h-". ~ <El s c NO:.. "'.;" '1NSIGP/Pf; SIGNIFICANT I 1) E N T ~ . 'VT N I~i T~! ~ NO ~ 4M~, (]P )-]i-' ) V T-] ] l'1 S V"151 AC C NO RECORDABLE INDICATIONS PSI ON NEM BOLTS PLAN 2-0951 4AlS(]~)-~~ V ()L ]MSU-073 45 NO RECORDABLE INDICATIONS tlS-,".6] )-1(. VT ~H 1HV-0246 ACC NO RECORDABLE INDICATIONS l'5-? ii ] '.I-] 7 V T3>l 1HV-0246 ACC NO RECORDABLE INDICATIONS

 /AS-i"6]           I-2]

VT':H ]HV-0246 ACC NO RECORDABLE INDICATIONS 1HY-0246 ACC NO RECORDABLE INDICATIONS HS- i" 61"- 72 V T3iH ]HV-0246 ACC NO RECORDABLE INDICATIONS 5'IS-2i> ] 'I-'4 VT~H ]HV-02'l6 ACC NO RECORDABLE INDICATIONS A( S -P - E) ) 0 iT ( L) V T-EXAHINATION SUHHARY TABLE PAGE 001 foER 1 t)D: SYSTEH."OR CUHPONENT HS(1) -4 DAT E 0 8/20/93 (tUTA(it . ti f) DESCRI'PTI;ON' STEAH f,~Nf, A IJR A)'NO 'IO ~ EXCH. DATA EX AH J,N~A'IIlI-'- E>AH ~ St) ELT NO .,: g, f:QSI G4l4IF!$ S I GNIF I C ANT

  ]DI 'I T .."IO.                           ~) Ti-.'   4'I 0 ~            ~NQQQ~
                                                                                      'QDJCii" ..'EOHQQQY OTHE/           R~EARQS f)S-15 I V  r.'.I>  ]HV-0247           ACC                                             NO RECORDABLE            INDICATIONS 4 E. H: ( ] ) A          1
4) / 4V -P 0 SUN 1ySN-037 ACC NO RECORDABLE INDICATIONS t'.5-]2 ~

V 1 'fl 1 HV -0248 AC C NO RECORDABLE INDICATIONS i" ~- I 21 V I .') I 1H V-0244) AC C NO RECORDABLE INDICATIONS

  ,5  0 t      . ( I ):4   - l L. I SU-09'5 4) 1Hi                                                                NO RECORDABLE            INDICATIONS Sl)R       ] HSYi-058         ACC                                             NO RECORDABLE            I NDI CAT IONS 40<S(1              ) ti-7 VOL        ] f) SU-0    ~'5                                                   NO RECORDABLE            INDICATIONS
                                                       ]HSH-0455          RCC                                             NO RECORDABLE            INDICATIONS
  .'4 (t t) .: (   1   ) A - l L ')   1 V  tiL     1 "I SU   -0 9"    45                                              NO RECORDABLE            INDICATIONS SU~         1HSiH    -0 J.5   AC C                                            NO RECORDABLE            INDICATIONS cutis(         1   ) '.-1LDO VOL        1HSU-092           45                                              NO,REC.O DABL,E          I NDI CAT IONS 1   H 5!" -0 5 3   AC C                                            NO)  ktOQPQE             I NDI CAT IONS P)4             44 ~

I VT~ ) 1HV-0248 ACC NO RE~pl L:-E- I NDI CAT IONS MS- I 14) tIfg@+ ~

                                                                                                                                            +pi VT   5)I   1H    V-0248       ACC                                             N0 ~ R Cga        gJ'E   I NDI CAT IONS t>>" 11't                                                                                                                       r~gi ~
                                                                                                                                          'P+'

VTRII ] HV-0248 ACC NO REEjll@t)ttLE I NOI CAT I ONS

0 1:H)'-0P 1)ASH I NGTON PUBLIC.. SUPPLY SYST EM INTf OVAL. '1 NO N-DESTRUCTIVE. EXAH ION

SUMMARY

TABLE PAGE 0 )'f ll f Of!: ) 3 QS t 1) -4 08/20/93 (>U f A(;f: 1:8AW1NG SYSTEM'.OR DESCRIPTION f~ COHPON!ENT STEAQ /FANE A DATE f.X AM ~ DATa EX AQJ.Q~A~IQ~R ES ' X)!H ~ SHf LT NO .',,;;,.=';""-',I.NSI,GQQi .~- I GN IF I CANT I l)EN1 ~ . % O. MS- 11'5

                              <<"1 T li ~ NO  ~           INDI  Ci; INO+i-'.ii'-               S GEOMETRY OTHER        R EMARKS Y 1'5H     1H  V-0248      AC C                                                     NO RECORDABLE         INDICATIONS VT~lt      1HV-0248        ACC                                                      NO RE CORDABLE        I NDI CAT IONS MS-101 V   1.<<ll  1H  V- 0248     AC C                                                     NO   R  ECOROABLE     I NDI CAT IONS 3OVS(1)u-lr              LUO VOL        1MSU-093        4S                                                       NO RECORDABLE         I NDI CAT IONS SUR        lMSM 054        AC C                                                     NO RE COR DABLE       I NOI CAT IONS 3 0 n.': ( 1 ) A -

1!'OM Vnl 1M SU-093 45 NO R E COR D ABLE I ND I CAT I 0NS S Uf( lMSH-054 ACC NO RECORDABLE I NOI CAT IONS S(1 ) A-1< Lf) VOL 1MSU-095 45 NO RECORDABLE I NOI CAT IONS S Ull 1M SM -0 57 'AC C NO RECORDABLE I NOI CAT IONS l!S ] 0(> VT 5! l lHV-O24a ACC NO R E COROABLE I NDI CAT I ONS Y T.?H lHV-l)248 ACC NO .$ PCP DABj E I NOI CAT IONS IPE 9<<! -:.'-<8,.- @<%.g-" V T.'H 1HY-(1248 AC C NP rttFCO LiE I NDI CAT IONS A7 VT5H lH V-0248 ACC INDI CAT IONS 18MS(1) A-3 J~ VOL 1MSU-091 4S INDI CAT IONS SUR 1MSMi-052 AC C NO R'KC5$ PAS.L.E INDI CATIONS

wqt'- n2 'WASHI NGTON PUBL IC POMER SUPPLY SY STEM > N T f l'. V A L::) l NON-DESTRUCTIVEEXAMINATION

SUMMARY

TABLl PAGE 003 I'ER I nil S YST EM',OR "COMPONENT MS ( 1) -4 DAT E 08/20/93 DESCRIPT'? ON',~A'g STEAM J ('RA)l)N( "O

                'UTA~~:
                    ~
                           =:,
                                -' 1 I

Q I )'p Itt[E A f VAM. l)A TA

                                     '.'( 'i-) ~ 3Hf ET JUL)i T~ ')()          ~                        NO.

51$ (1 1 $ Vi "I 1HV-024)3 ACC NO RECORDABLE INDICATIONS

 'tlS-     ) 4 n V  1 '0     1HV-0248        ACC                                            NO RECORDABLE     INDICATIONS
 ]8!)< ()               )'i-"

1MSU-0 94 45 NO RECORDABLE INDICATIONS 1".SM-055 ACC NO RECORDABLE INDICATIONS

 )   nl);,i(    1
                        ).'a VOL         1MSU-094        45                                             NO RECORDABLE     INDICATIONS 1(.) ",M -055   AC C                                           NO RECORDABLE     INDICATIONS V T.) ll    1HV-0248        ACC                                            NO RECORDABLE     INDICAT IONS
 )4  g    tgt~

V T.SH 1HV-0248 ACC NO RECORDABLE INDICATIONS Mb-E)'i V T.~)) 1H V-0248 AC C NO RECORDABLE INDICATIONS l') c. E'3 VT ~H 1HV-0248 ACC NO RECORDABLE INDICATIONS

   

EXAM ~ DATA EX I'M.I NjJ~IQ~ E . LX AM ~ SHEET NO" -.~.','i'I.NSl Ght'HP I GNI F I CANT I DL'ttT ~ .'I" ~ . I!~ NO ~ ~IDgg'- -'-'QQDJ~e<'~ GEOMI.TRQ QT HER R~EARQS 2f,t!S ( I ) '-'-."OL;J Vi)L IMSU"075 45 NP RECORDABLE INDICATIONS

                                    'UR      IMSM-05tl    ACC                                                    NO RECORDABLE     INDICATIONS 2 f- M '~ (  1 ) ~ -2 "

VOL 1MSU-072 I NTERMI TTENT AT VARYING LOMER AMPLITUDES'O GEO 1MSM-056 ACC NO RECORDABLE INDICATIONS P e, t l w ( I ) i 2 0i i I) V C~L IMSU-076 45 NO RECORDABLE INDICATIONS SUR IMSM-038 ACC NO RECORDABLE INDICATIONS 26hlS( I )!I-20/ iV 20 SUR It'tSM-045 ACC NO RECORDABLE INDICATIONS MS- ] I4 V T:>I 1HV-024tt ACC NO RECORDABLE INDICATIONS MS-I73 VT 'H 1HV-0248 ACC NO RECORDABLE IN'ATIONS t'tS-171 V T5H 1HV-0249 ACC NO RECORDABLE INDI CAT IONS nq 7i'I VT5H 1HV-0248 ACC NO "fC ~ tE INDI CAT IONS MS- <<8,"s VTAH 1HV-0249 ACC NOi LE I NDI CAT IONS tlS- I 70 pp VT <fl 1HV-0248 4CC NO E. I NDI CAT IONS M 8- ('ti 1 VT 'H IllV-024!I ACC NO RE; 6LE INDI CATIONS

4'NP- () P WA SH I NGTON PUBL IC POWER SUPPLY SYSTEM JNT).()VAL: 01 NON"DESTRUCTIVE EXAHINATION SUHHARY TABLE PAGE 002 l EPTn)): S YST EH OR, CDHPQNENT l HS ( ) -4 DATE 08/20/93 (iU 1 A Q)l h Lj 1 (sE:

            ) ) (i '3 (),

DESCRIPTION::~A J STEAM Igg 8

                                     'XAN ~

DATA

                            / A)'I ~ SHEET 1 t)f."f                MT)l~      )JO~
 ')S- Ii 7 VT;<)      1)] V-0248          ACC                                       NO RECORDABLE  INDI CAT IONS
 )q c;   u g g. ')                                                                                  I k

V T '>) jH V-0249 AC C NO RECORDABLE I NDI CAT IONS V T ~)l 1)i V-0248 AC C NO RECORDABLE INDICATIONS Q(-)( 0 VT 4H 1))V-0248 ACC NO RECORDABLE INDI CATI'ONS V1 '.i) 1HV-0248 ACC NO RECORDABLE INDICATIONS

 <<1~-    1 i~ 7 VT <H      1 ll V- 024))       AC C                                      NO RECORDABLE  INDICATIONS MS-154 V f,')l    1HV-0248            ACC                                       NO RECORDABLE  INDICATIONS MS- 177 V T 5))    iH V-0249           AC C                                      NO RECORDABLE  INDICATIONS HS-14          7 V T 4!I    1 HV  - 1) 2 4 ()   AC C                                      NO RECORDABLE  INDICATIONS V T.<1)    1HV-0248            ACC                                       NO RECORDABLE  INDICATIONS
 'lS-    1  4    ~

VT -H 1HV-0248 ACC NO 'RECORDABLE INDICATIONS

1!P - 0 2 WASHINGTON PUBLIC SUPPLY SYSTEM I NT5 c'.VAL. 41 NON-DESTRUCT IVE;.EIt'AHI I ON SUMM AR Y T ABL E I AGE 00 PER I Oli: 0.5 S YgT,EH 'OR C05P~PhlENT ~S5.1) "f DAT E 0 8/20/95 OUTA GE. 8 hl L'RAP ING 'oO ~ l XAM ~ DATA ~EAMJ~hlA ~If 'ES "'

l. X AM ~ SHLET -'I NO h', =f '4,: N S 'GN IPc
                                                                         $              S I G N I F I C AN T I DEfi   T ~ ~  '!0 ~     M T! l~   NO   ~        INDI C e.-.:.-..INDI C'e~,      G EO METR Y      OTHER        REMARKS 96M.p( 1)       C-20/ 4Y-20 SUR       IMSM-042      ACC                                                           NO RECORDABLE           INDICATIONS h'S- '721    '3 V  T.')ll 1H   V-0240   AC C                                                          NO RECORDABLE           INDICATIONS MS-50 V T.4H    1H   V-0248   ACC                                                           NO RECORDABLE           I NDI CAT IONS MS-7)    7 V  T.'H   IHV-0249      ACC                                                           NO RECORDABLE           INDICATIONS hlS-1 001'!

VT .>> lH V-0248 AC C NO RECORDABLE INDICATIONS MS -,5(, 1HY-024H ACC NO RECORDABLE INDICATIONS hler- 1 000'( YT'H IHV-0248 'CC NO RECORDABLE INDICATIONS VT '>H 1HV-0240 ACC NO RECORDABLE INDICATIONS VT <<3 1H Y-0240 ACC NO RECORDABLE INDICATIONS h'lS- '!~) 9l~ V1 ~H 1H V-0240 AC C NO RECORDABLE INDICATIONS

 !" S-48 V T.4H    1H Y-0240    ACC                                                           N 0>.Rg'CPP+PBLE        INDICATIONS
 ~~

S c3t)4!g V Thill 1H Y-024!i AC C N O'+~~4P4+bL E I NDI CAT IONS V,Q w7  %@8@4""y~~g:-,"... V T'iH 'I l!V-0248 AC C NO. RC,'COPQkeiE INDI CAT IONS MS-P6 V T;)fl IHY-0246 Acc INDI CAT IONS

~ ter r)~ WASHINGTON PUBLIC POKIER SUPPLY SYSTEM rrlTE't YAL: !'1 NO tc-OE S TRUCT I VE E XA MI N AT I ON SUMM AR Y T ABL E PAGE 001 l'1 i!1.)[): '),C SYSTEM, OR COMPONENT QS(g) -4 DATE 08/70/93 ()) 1 I A i"i1.: [) R A i~ 1 ',i i: ~ fl

                        ) ~
                            " .. . '.) 4 1 XAM ~

DESCRIPTION: ~Ay STEAM g~NE D

                                                                                         ~.p>n t

I liLT '*0>> ~ ~

i. X 'i'5 ~

M Ti~ ~ DATA SHEET iV0 ~ NO.. 'NSI Egal.NAQ~IQ I!ItOIC ~

                                                                                       ~R$ UQTS (NIFF
                                                                                  'INDI6>>:-

SIGNIF ICANT GEOMETRY OTHER R E.MAR KS l<S-71! -) 1MSM-056 ACC NO RECORDABLE INDICATIONS

  ")S-6't VT i)l      1HV-0748          ACC                                                NO RECORDABLE      INDICATIONS 0  g" i Yr     H     1H  V-0248       ACC                                                NO RECORDABLE      INDI CATIONS S-ii7 VT'il       1rr V-0248        ACC                                               NO RECORDABLE      INDICATIONS
  ')S-(      1 YT   ~H     1HV-02'!8          ACC                                               NO RECORDABLE      INDICATIONS QS     1  PO ih YT   '!l    lHY-0248          ACC                                                NO RECORDABLE      INDICATIONS vw.')r      1H   Y- J'248      ACC                                               NO RECORDABLE      INDICATIONS lyr    t    ]

V T.'ii 1HY-0248 ACC NO RECORDABLE INDICATIONS ug ri VT irl 1H V- 02".) 5 ACC LOOSE LOCK NUT. EVALUATED AS F UNCT ION AL ~ VT "H 1HV-0248 ACC NO RECORDABLE INDICATIONS

  ":S-vl r)S-lnr) '>>

VT iir 1H Y- 0248 AC C NO~ '.ALE I NDI CAT IONS VT"'i 1HV-0248 ACC NO Q'>CqLO LE INDICATIONS VTSH 1HV-0248 ACC NO kgCOQQA L.E INDICATIONS

.-NP- n," WASHI NGTON PUBLIC, SU~PLY SYSTEM >Nor.RVOL. NO N-DESTRUCTIVE E)fAHI ION SUHHAR Y TABLE PA GE 00 SYSTEH; OR"-'C,OHP.QUENT HS tg) -4 DAT E 08/20/93 OES GRIP TLON;i H8"-;HDR / BYPASS VLV F RAM ~ DATA EXAHINATION'RESULTS E X.".M ~ SHEET NO - " I NSIGN IF-. S I GNIF I C ANT DENT ~ ~ Ng ~ T>l ~ NO INDI C 'INDICi '<'. GEOMETRY OTHER REHARKS 2 <t M! ( 1 ) -,? VOL 1MSU-077 it5 NO RECORDABLE INDI CAT IONS c U 1MSM-094 ACC NO RECORDABLE INDICATIONS

~Nf'-07 WASHINGTON PUBLIC POWER SUPPLY SYSTEM

]'I ft."VhL:          0 f                                NOtl-DESTRUCTIVE EXAMINATION SUMM AR Y TABLE                                              PAGE  001 f' l' (IO:                                                   SYSTEM OR COMPONENT                    RFW(1)-4                                 DAT E. 08/20/93 r'U Th    bi:                                                DES  CRIPTI ON      g~PEQDW ATER L,IME              A I IR A IQ ] t(, 'l 0 ~                                                                rV EXAM.

DATA EX AM I NAj~IN RE~SU QS E w Sfl E E T NO N SI GPJ ZF..' I GN I F I C AN T

  ] I)L t!T.. xO.

few'4I T

  • .~ i ( ] I) -4 V ()L 1F WU-115 45 NO RECORDABLE INDICATIONS CIRC SCAN ONLY ".f(l-V(]f) a-:: V (IL 1F WU -112 45 NO RECORDABLE INDICATIONS SUP 1F WM-026 ACC NO RECORDABLE INDICATIONS 5f(~:N(] 1) A-1 SUB ] FWI)A-02K. ACC NO RECORDABLE INDICATIONS 24RFW( 11 d-,'A VOL 1F WU-110 45 NO RECORDABLE INDI CAT IONS 741> FW ( ] ) A-3 V I)L ] F1IU-111 45 NO RECORDABLE INDiCATIONS CIRC SCAN ONLY "4Rl "(]) A-5 VOL 1F WU-132 45 NO.RECORDABLE IN OI CAT IONS C IR CQSCAN",.:ONL S Y 2s f':,4 ( 1) A-6 ~ "$y ~ VOL 1FWll-133 45 NO RECiRDPSLE IN DI CAT TONS C IR C";>%PJ'S'-] ONL Y ,"-4)I ]I'AI( f ) A-7 f'~+ Qf~g VOL 1F WU-120 NO RE45iIOANLE IN DI CAT I ONS C I R C"-'SCUBA'ONLY Qi,'- 0 Ws)P > ~ ) WASHINGTON PUBLIC SUPPLY SYSTEM fNrf:f VnL: VOW- DES TRUCT I Y E,EXAHI I ON SU MN AR Y T ABL E PAGE 00 ('E f(1 >')0: 0 '. SYSTEff OR": COMPONENT RFM (I )-4 DAT E 08/20/95 ()U 1 h (:-E: DESCRIPTION.~ "~~'fEQDMATQR~jgg A L>RAW 1 N(T Ak(' F~'-1 T)1 f'X AH ~ DATA ~14'X~AQNATIOQ-QE~S C X >4'~ ~ SH"ET NO,'. -,-'; INSI GNIF.+ S I GNIF I C ANT ID L NT .. <<'I (.T. fl I'I I'(0 e INDI c"...'NDIce"PI. GEOMETRY 0T HER RENARKs I( f W 1 (( > ( '.: ) 3 F Qf>(<<02'3 AC C NO RF CORDABLE INDICATIONS 7 4 R f' ( 1 ) A - E'. V ~ 1F MU "121 45 NO RECORDABLE INDICATIONS )'OL 1FI'M-027 ACC NO RECORDABLE INDICATIONS 24RF':(1) 4-1" 1FMU-125 45 NO RECORDABLE INDICATIONS CIRC SCAN ONLY 12(U;(1) "C-12 Y(L R- R8-1.S7 4 5 R OOT AND ID GEOHET RY 1 2 R f..N ( 1 ) ". C - 1 5 VOL u-I<8-1 )f( 60 45 RL AND SHEAR RECORDED ROOT ANO I NS I 0 E SURF ACE GEOHETRY I OWNS'I RN EXAN L I NI ED TO ~ M ~ OF I 5" FROH MCL DUE TO NOZZLE CONFIG S EE NOTE 1 74" W(1) A-17 ~ VOL 1F WU-12') 45 NO RECORDABLE INDICATIONS S Ur( 1F W(". 057. AC C NO RECORDABLE INDICATIONS 1HhFM(1) A-I VOL 1FMU-127 45 NO ITT>~k5$bLE INDICATIONS MELBIIII0%'fAHP,ED lBRHR < I) A-l S U(< 1F WN'-0 52 AC C NO gag SPILE INDICATIONS 1 Rf I'I". ( 1 ) A 2 YOL lf WU-1/1 ID /If',gg'.270-0 RECON'5 ~i.'A4;:,A '>>OT AND 0-90 f'NP- f) 2 l'ASH I NGTON PUBL IC POMER SUPP L Y S YS TEM ] NTf.RV AL: 0) NON-DESTRUCTIVE EXAHINATION

    SUMMARY

    TABLE PAGE 003 f 1 f? I Pf): SYSTEHi",OR,"-COMPONENT RFM(g)-4 DATE 08/20/93 Putn'L: f8 DES CRIP.TK ON ";.RX.';F.EEDM ATER L INE A ff)A'; ING Npo "f "-101 f.'X AM ~ DATA EX~AH, NATIDN ~REStl TS E )I 'A> 1 fJG ~~f0+ "1 >i-102 E XAH ~ X AH ~ DATA SHEET EX~A~H~A, ~ ~R "TS I DE 4T ~iO ~ HTH>> NO 24RI 4 (1'l 8- I A VOL 1F MU-117 45 NO RECORDABLE INDICATIONS EXAH LIHITED BY VALVE CONF IG SEE NOTE 1 24Pf Iq'(1) <(-1 V()L 1F'a'U-114 45 NO RECORDABLE I NDI CAT IONS CIRC SCAN ONLY c' R f. V( 1 ) '1 - / ")F. "~i ( 1 ] ) -4 1 V (1L 1F MU-118 45 NO RECORDABLE INDICATIONS CIRC SCAN ONLY

     ~/PE    !;( 1  1  ) f)-2 V)L       1F 'QU-119     45                                            NO RECORDABLE      INDICATIONS CIRC SCAN INCLUDED
      'iI l'E-4( ] )
    

    V i".L 1F WU-115 45 NO RECORDABLE INDICATIONS CIRC SCAN ONLY

       ?nl7f   l4>(  1 ) P     l V<:L        1F ~U-116      45                                            NO RECORDABLE      INDICATIONS CIRC SCAN ONLY Pf )i      I( gl ir) 8UR         1F 1)H -OFF(    AC C                                         NO RECORDABLE      I NDI CAT I ONS f(f E'-1 64 V T3H      1HV-0246         ACC                                          NO,Itic;$ 8)SLE INDICATIONS 7 4 f'   '~'  1  )  0 -8 VOL        1 F ~~U-I  22                                                                   AN BE   SEEN   360 DEG BLE LEVEL~
    

    12Rf "(l) BF-2 VOL 1FVU-134 45 NO->>, 'Q. BIE I NDI CAT IONS S UE< fF WE'>>069 ACC No glEcoj@4LE INDI CAT IONS

    f'Nfo-02 !WASHINGTON P UBL IC POWER SUPPLY S YS'I EH ln,Tr OVAL: R) ON- DESTRUCT I V E 'EXAHINAT I ON SUHH AR Y I ABL E PAGE 002 f C((IOD: SYSTEH'>OR: COHPONENT RFM(1)-4 DATE 08/20/93 OUTA': !(fi DESCR.IP.TIONgr'."fX -F.EgDMATER QJ(II/ 8 ! Rat'IN!0 XIO. ".!" <<' 1 02 CXAN. DATA EX ~AH N~ I 0 /~Egg QS fI!t TEXAN ~ SHEET NO I i" ..;:;INSIGNIFi SIGNIFICANT

                       'V) ~                                                           "-
    

    If)f (IT ~ ~ HT'l ~ ti2 ~ JMQJ f,~ 'QNOJ~Ci g~MQT~Q QJ HER R~HARl(S 1 c'( f'>> ( l ) ~f -7 V f)L 1F MU-135 45 NO RECORDABLE INDICATIONS 1FW-034 ACC NO RECORDABLE INDI CAT IONS 1 2 P, F H ( } ) T'i F- LI. VOL 1FLIU-130 45 NO RECORDABLE INDICATIONS SUR 1 f f-IN-033 ACC NO RECORDABLE INDICATIONS 24Pf <<(1) i -I,! VOL 1FiU-124 45 NO RECORDABLE INDICATIONS Sl)4 1F VH-030 ACC NO RECORDABLE INDICATIONS L IHI TED EXAM FROM 0-90 DEG AND 180-360 OUE TO ACCESS ~ 90-180 DEG EXAMINED PT REPORT 1FllP-068 1F 4!P -068 AC C NO RECORDABLE I NDI CAT IONS L IHI TED EXAM FROM 90-180 OEG SEE REPORT 1FMH-030 FOR REMAINING EXAH 1HR f '4 ( l ) 8-1 1F AU-126 45 NOTRE).RDABLE INDI CAT IONS

                                                                                                                   ,."  <<k-.l'P~)AP";4-S U'(   1FMH-031         ACC                                            NO      RkgORQABLE INDICATIONS 1 fl fk f'.4 ( 1  ) 8-4 VOL     1F<<U-125         45                                             NO      R(/DR.bAPLE INDICATIONS f .g ~if 'QPt$ 'i, SUR      1F 'k!H-031     AC C                                           NO,RL             R)IlIDLE INDICATIONS Rl T4- l f>3(
         ~
    
    4) I!'I j)Pgf:
                                                                                                                        ,~PJ'S SUR     1FVH-036         ACC                                            NO      R)CI)RP'II!fLE INDIcATIQNS Ie  I Ai!)'('/ST rf>>
    

    0 0 4 Wf'2 MASHI NGTON PUBLIC SUPPLY SYSTE M f ff Tl. RVAf.. < i, NOhl-DESTRUCTIVE E)the ION SUNNARY TABLE PAGE 0 I'Lf' >f) ~ S YS T EN,OR 'C OHP ON EN T DAT E 08/20/93 nU TA Gf.: DESCRIPTION ~ ~X>'<FQEOLJATER I ggg 8 f~ffA:~t:ff,- '>>. -r;-i~P

                                         'AN g)lQV, ~
    

    DATA SHEET

                                               ~
    

    NO

                                                                 '~~
                                                    '=" "1-'-'-'<.
                                                             ';- INSIGNIA>>       SIGNIFICANT I U.'>> T  ~ ~
                   'i 0 ~       HTii~    f40 ~
    

    0f ~'-'~l< ',l<; ff ) V T-2 I VT2-93 ACC NO RECORDABLE INDICATIONS

    'I N f- - T) P WASHINGTON PUBL.IC POWER SUPPLY SYSTEM ANTI. RV AL: 0 l VOl'l-DESTRUCTIVE EXAMINATION SUMMAR Y TABLE PAGE 001 PER I I)D: '> I SYSTEM 'RT COHP ANENT R FM (1 1) -0 DATE OB/20/95 (lUT A <-.-Q: RESCRIPTION:, ~RRCTIIR LgfgllA~TR {;((AiW I t)G 'f) ~ EXAM'ATA ( AiM ~ SH! ET Dl NT il 1 H iV0 ~ RF W ~{'-l0 5 {L ) V 1-2 1VT2-95 ACC NO RECORDABLE INDICATIONS

    Vlf'-02 MASHI NGTON PUBL IC SUPPLY SYSTFH I NTF RVAL. NON-DESTRUCTIVE",EXAHI ION SUHH AR Y TABLE PAGE 0 1'ERI nfl: ".3 S YST'EH'R;.COHRIONENT RRC (2 )-4S DATE 08/20/95 l'UTA Gf: "8 DESCRIPT'IDN j~CTQR RQCQR LgQP A LR A'>>'1N( '>>- ';1C-1 01 EX af~. OA TA I:XAII/NAI'~If'*~E~S i TH.

                                         '8 I( AA.'1 ~   SHLET           NO,'.",: - .." '  NSI GN fF, S I GN IF I C ANT I UE   lAA T ~
             ~
    
    • I ~ NO leleC j A-2 (I')
                                          $ Ule           1RRP-120        ACC                                            NO RECORDABLE             INDICATIONS l?  RC-SA-1             (")
    

    1RRP-122 ACC NO RECORDABLE INDICATIONS 4Rf> 0 ( t') > A 2I ') V T-1 1 fe R V-026 AC C Nn RECORDABLE INDICATIONS Af',n((~>> A-2 LP V r-1 1leRV-027 ACC NO RECORDABLE INDI CAT IONS l' C - 5 k "". "!

                                                 'll       1HV-024F       ACC                                            NC RECORDABLE             INDICATIONS RPC-SA-r 3:  l'  V      -   7 A l 3 L 1'T1,'ll V                 1H V-0246      AC C                                           Nn RECORDABLE INDICATIONS V  T-.1          1RPV-028                        ACC                           LIGHT SURFACE RUST (elec   -sk-3           ":
    

    v 1:.o 1HV-0246 ACC NO RECORDABLE INDICATIONS i ~'" C( 1) A ."0/12~ R C( 1 ) -4S VOL R-R8-125 45 ~60 NO RECORDABLE INDICATIONS SCAN LIHITED ONE .SIDE TO SMEEPOLET CONF I G ~ SEE NOTE 1 SUB 1RR~-121 ACC "p ROQNDg 180-90 DEG

      >~C      - ."w A  - I3 V  I '4l          1 f3 9-0246   ACC                                            NO'. RFdjA.5$8QE         I NDI CAT IONS
    

    ()QC SA "(~>g::;:r.:.'$.::

                                                                                                                                               '/8 VT,"H            1HV-0246       ACC                                            NO    j'F'GOI(DP(L'E I NDI CAT IONS C-S A-1 fe R f )<C-SA            18 1
    

    V T.iH illV-0246 ACC NO:, I331$ 48fg LE INDICATIONS V T.'H 1HV-f)24- ACC NO..Rl(CDR;.DABLE I NDI CAT IONS

    """"9/j74+

    r NP-02 WASHI NGTON PUBLIC POWER SUPPLY SYSTEM

    )r )LRVn~:                                   NON-DESTRUCT I V E XAMINAT I ON 
    

    SUMMARY

    TABLE PAGE 002 r EPI On: SYSTEM,,OR" COMPONENT RRClg)-4S DATE 08/20/93 ('UI A r; f.: DESCRI'PTION'EACTQR RgCJR QQQP A Urr A V I N G 'l 0 . ""RC-l01 t.X AN ~ v'ATA EQ~AQ)~~Ihl g @+~S

                                '::)  ~ SH $.E T   NO  .:.').),
                                                                   =
    

    ENSIGN'IF, SIGNIF ICANT I DENT ~ ~

                   '4 0~        MTH~    NO  ~      INDI C'i,    I/O~Ce+~,i  GEOMETRY OT HER   R EMARKS RRC-Vr)-101(L)
    

    V 1-2 1 VT2-93 ACC NO RECORDABLE INDICATIONS n3" t>> I'

    ISI

    SUMMARY

    REPORT RF93A APPENDIX C ASME SECTION XI REPAIR AND REPLACEMENT LISTING NIS-2 OWNER'S REPORTS This appendix summarizes ASME Section XI repair or replacement work performed and closed out between July 19, 1992 and June 21, 1993. The status of the NIS-2 Owner's Report is stated for each repair and replacement work performed.

    APPENDIX C ASME SECTION XI REPAIR AND REPLACEMENT USTING FOR WNP-2 8/24/93 COMPONENT NUMBER / WORK DESCRIPTION DESC OF COMP R&R REPORTED IN 2%728 AR 6375 Replaced mechanical seal for pump FPC-P-1A Pump RF93A Summary Report 241729 AR 6375 Installed pump case vent for pump FPC-P-1A Piping See Note 1 241737 AR 7283 Modified test connection with valves HPCS.V<7 and HPCS-V~ Piping RF93A Summary Report 2-0739 AR 7285 Modified test connection with valves LPCS-V47 and LPCS-V-38 Piping RF93A Summary Re port 2%740 AR 7299 Modwed test connection with valves RHR-V-157C and RHR.V-158C Piping RF93A Summary Report 2%771 AR 9071 Fabricated and installed restriction orifice for SW-FERA Piping RF93A Summary Report 2%772 AR 9072 Fabricated and installed restriction orifice for SW-FEW9B Piping RF93A Summary Report 2%777 AR 7431 Replaced body to bonnet bolting for valve RHR.V-SOB Valve RF93A Summary Report 2%778 AR 6913 Performed work for JCI support B-220-1077-145 Support RF93A Summary Report, 2%779 AR 6913 Performed work for PDM reinforcement structural steel Support RF93A Summary Report 2%780 AR 7435 Modified test connection with valves RHR-V-157B and RHR-V-158B Piping RF93A Summary Report 2%782 AR 7425 Modified test connection with valves HPCS-V-713 and HPCS-V-714 Piping RF93A Summary Report 24)806 AR 4935 Replaced stem/disc assembly for valve MS-V-1 Valve RF93A Summary Report 24817 AR 7595 Replaced disc insert for relief valve CCH-RV-2A Relief valve RF93A Summary Report 24XI19 AR 8426 Installed test port for relief valve HPCS-RV~ Relief Valve RF93A Summary Report 2<820 AR 6609 Removed scratches on the disc seating surface for valve MS-V<1 Valve RF93A Summary Report 241826 AR 5436 Plugged tube for heat exchanger OG-HX-1 B Heat Exchanger RF93A Summary Report 24XI51 AR 8906 Machined defects on plug seating surlace for valve RHR.FCV~B Valve RF93A Summary Report 2~52 AR 8990 Replaced wedge for valve RHR-V-27B Valve RF93A Summary Report 2~53 AR 9103 Replaced relief valve HPCS-RVQ5 inlet piping material Piping RF93A Summary Report 24855 AR 8988 Replaced disc for relief valve RHR RV.25A Relief valve RF93A Summary Report 2%859 AR 9075 Installed cathodic protection for spray pond siphon pipe - Spray Pond 1B Piping RF93A Summary Report 2%860 AR 9080 Removed vent valves SW-V-168B and SW-V-169B Piping RF93A Summary Report 2~69 AP 0086 Modified connection with failed weld for valve FPC-V-730 Piping RF93A Summary Report 2%871 AR 9426 Fabricated and installed restriction orifice for SW-RO-12A Piping RF93A Summary Report 2%873 AR 9977 Installed thermowells and annubars in SW piping (DG-1) Piping RF93A Summary Report 2%874 AR 9976 Installed thermowells and annubars in SW piping (DG-2) Piping RF93A Summary Report 2~75 AP 0081 Installed thermowells in SW piping (DG4) Piping RF93A Summary Report 2~77 AR 9070 Body to bonnet seal weld for valve SW-V-931 B Valve RF93A Summary Report 2<878 AP 0686 Installed flushing taps for Scram Discharge Volume (SDV - CRD) Piping RF93A Summary Report 24XI86 AP 0421 Modified connection with valve Pl-V-901 Piping RF93A Summary Report 24889 AP 0244 Replaced disc insert and nozzle for relief valve S/N 63790~4120 Relief Valve RF93A Summary Report 2%890 AP 0245 Replaced disc insert and nozzle for relief valve S/N 63790404057 Relief Valve RF93A Summary Report 2~91 AP 0246 Replaced disc insert and nozzle for relief valve S/N 63790~%122 Relief Valve RF93A Summary Report 24$ 93 AP 0644 Refurbished and reinstalled MS-RV<D, S/N N6379040<126 Relief Valve RF93A Summary Report 24)897 AP 0640 Replaced existing relief valve MS.RV<C with spare S/N N63790~%052 Relief Valve RF93A Summary Report 2~98 AP 0639 Replaced existing relief valve MS-RYE with spare S/N N63790~4057 Relief Valve RF93A Summary Report 24900 AP 0427 Installed lap joint flange for relief valve RHR-RV~B Piping See Note 1 2.0905 AR 8762 Body to bonnet seal weld for valve DO-V<1A Valve See Plan No 241959 2%910 AP 2671 Replaced relief valve RHR-RV&with blind flanges - Pre outage Piping RF93A Summary Report 24)910 AP 1457 Replaced relief valve RHR.RVQ6 with blind flanges - Outage Piping RF93A Summary Report 2%911 AP 2245 Removed drain connection with valves MS-V-238B and MS-V-239 Piping RF93A Summary Report 2%913 AP 0081 Installed instrument tubing for SW.FT-9 Tubing See Note 1 2%914 AR 8980 Body to bonnet seal weld for valve SW-V~ Valve RF93A Summary Report 2%915 AR 8981 Body to bonnet seal weld for valve SW-V47 Valve RF93A Summary Report 2%917 AR 9069 Body to bonnet seal weld for valve SW-V-1 09A Valve RF93A Summary Report 24918 AP 0388 Replaced disc for relief valve RRC-RV~A Relief Valve See Note 1 2%923 AP 1954 Refurbished and reinstalled MS.RV-2B, S/N N83790404049 Relief Valve RF93A Summary Report 241926 AP 1952 Refurbished and reinstalled MS-RVP B, S/N N6379040<053 Relief Valve RF93A Summary Report 2~27 AP 1951 Refurbished and reinstalled MS-RV-1 C, S/N N63790404046 Relief Valve RF93A Summary Report 2<945 AP 3471 Installed and seal welded leak off connection for val ve MS-V-1 46 2%953 AP 3765 Modified instrument lines Pl(1)AS-X37e and Pl(1)AS-X37f Valve Piping See Plan No 241958 See Note 1 0 2~58 AP 3471 Installed and seal welded leak off connection for valve MS-V-1 46 Valve See Note 1 2~59 AR 8762 Replaced valve DO-V<1 A Valve See Note 1 24$ 70 AP 4031 Installed U bolt for support B.220-107345 on Dwg D-220.9.0-X39d Tubing See Note 1 N/A AP 0797 Replaced snubbers for support MD-1 285-14A and MD-1287-11 Supports RF93A Summary Report Note 1 NIS-2 form not required. Replacement work for one (1) inch nominal pipe size (NPS) and smaller Page 1

    PLAN NO 2%728 xASHJNGTOM pusuc potrKR SUPPLY SYSTEM( FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 7at/93 Address: 3000 George Washington Way, Richland, Washington Sheet: 1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Santon County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Rkhiand, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. Jdentfflcatlon of System: Fuel Poet Cooling (FPC) System
    5. (a) Applicable Construction Code: ASME Section III Code C4LSS 3, 1971 Edition with Winter 1973 Addceda, Coda Case: None (b) Applicable Edltlon of ASME Section Xl Utlllzed for Repairs or Replacementst 1 960 Edition with Winter 1980 Addenda, Code Case: N408
    8. ldentlfication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class FPC-P-1A Worthington 44 000019 (3 LR 9) N/A 1977 Yes, Code Class 3

    7. Descrlptlon of Work:
    1) Removed existing Replaced mechanical seal (gland plate) for pump mechanical seal (gland plate) from the pump
                                                                                     ~       tA.'Iho replacement work was performed as follows
    
    2) Installed new mechanical seel (gland plato) in the pump
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2OF28 trASHlNGTON PUBUC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Test Pressure: SS to 87 Psig Test Temperature: 944 F Component Design Pressure: t so Pslg Temperature: 2t P F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not appt'cabte Certificate Authorization No.: Not applicable Expiration Date: Not Appl'cable Cl 0 Prepared by Signed by Materials And nspection Manager, Materials And Inspection Date Z2- 3 Date 7- z7-4 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section N.

    By signing this certificat neither the Inspector nor his employer makes any warranty, expressed or Implied, concemlng the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal In/ury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions nspechx's Signature National Board, State, and Endorsernents

    XASHINGTON PUBUC POWER SUPPLY SYSTEM PIAN NO 2<737 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWnef: Washington Public Power Supply System (WPPSS) Date: 10/26/92 AddreSs: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: wNP.2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: High Pressure Core Spray(HPCS) System
    5. (a) AppliCable COnStruCtiOn COde: ASME Section III Code Class 1, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements:1980 Edition with winter 1980 Addenda, Code Case: N408
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D Built Replaced or Stamped No Replacement (Yes or No)

    Code Class HPCS(1) <CLl WPPSS HPCS(1) ACL1 N/A N/A 1982 Replacement Yes, Code Oass 1

    7. DeSCriptiOn Of WOrk: Fabricated and installed modified connection with valves HPCS.V47 and HPCS-V48. The fabrication and installation work was performed as follows
    1) Beveled one (1) socket end of the new valve for butt welding
    2) Performed PT examination on the beveled end ol the valve. PT examination results acceptable
    3) Cut and removed the existing connection
    4) Beveled the existing sockolet socket end
    6) Performed PT examination on the beveled end of the sockolet. PT examination results acceptable
    6) Installed new pipe and valves and made required welds
    7) Performed PT examination on the final welds. PT examination results acceptable
    8) Performed RT examination on the final circumferential butt weld. RT examination results acceptable 968.22684 (9/87)

    WASHINGTON PUBUC POWER SUPPLY SYSTEM PLAN NO 2%737 0 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other x None Test Pressure: Pslg ~ Test Temperature: F Component Design Pressure: Psig Temperature: o F

    9. Remarks: See attached NPV-1 Code Data Report for the following new valves HPCS-VD7, Serial No 79970 HPCS.V<8, Serial No 79969 CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable EXpiratian Date: Not Applicable Q

    Signed by Materials And lnspectio s Plant Technical Manager Date o 2.4, 2.. Date ro- r.~r t CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this Owner's Report during the period < - ~ W z- to /n -3'u-1Z and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions I pector's Signature National Board, State, and Endorsements Date l4'- ~- W~ 968.22684 (9/87)

    p>~ Qc.Z-D7~7 FORM NPY-') N CMTIF(CATE HOLDERS'ATA REPORT FOR NUCLEAR PUMPS OR yALyES As Required by the Provisians of the ASME Code. Section ll(, Div. 1 Jtzc~tr Va1ve Div. Ror %srne 7500 cne Ave. 'an Havs Ca1 iZ.

    ~ ';3>>
    

    by (Ns(n(( an(t address of N certlfiute Hnldert pashinfrton Public Power Supply Sys ems, Richland, WashinWoa j t(eorge nasaiagT.oa i ay fNeme end Address ot Purchaser or Owner) X Location af Installation Richland. Vashin ton if%'SS Hanford ~2 Job Site Built'anufactured frteme end Address/ Y Globe Valve . Nominal Inlet Size / Outlet Size 3 /4

    4. Pump or Valve (inch) linen)

    (a) Model No., (b) N Certificate Holder's (c) Canadian Series No. Serial Registration (d) Dravring (f) Nat'L (g) Year

                                                                                                                              '/A or Type                   No.                       No.                  No.           (e) Class       Bd. Na.
    

    15008 7SS51 thru N/A 765SO" 2 . 1 19S3 (5) cS- Y-3 5 AJ '2 70 c(- V-(8)

                                                                                                               ~    /
    

    (10) The va1ves a~ c{esionecl to bztntila a flttitiM~ vhich inchrhs 8~, m"en t~xttt tt D~~ttn tt zany tanet deocnonon (f t sen(ice for wnich eouiement was dssiened) o~ the ttsec{M i'tztLeh belc(tr ~

    6. Design Canditians 100 'F ar Valve Prcssure Class N/A (rt(((w(eg ~

    lT((mperetv(Il ~

    7. Cold Working Pressure psi at 10G F.

    L Pressure Retaining Pieces Mark No. Material Spec. Na. Manufacturer (a) Clstln s Disc-Co'de 1X20' Sejli "e 8o Rex Precision 1T01; Uv 10; 5F32) (b) Forgings Body- o 1 <o SA 105 Katratzuchi .0 (1) For manually operated valves only.

            'upplemental sheets in form of fists: sketches ar drawings may be used provided (1) size is 8-tQ x 11; (2) information in items 1. 2 and 5 on this Data Report is included an ea~ sheet. and (3) each sheet j~umbered and number of sheets is recorded at tap af this farm.                                                                                                                       g+wr.
    

    B( 4J I (

    Fof54 NPV 1 (Back) Mari No. Material Spec. No. Manufacturar (c) I Iting N/A (dl Other Parts Bac)cseat-Code 4J8o . SA "o4 Tv o30 Jor ensen Stee). 4H70. E 4 M. Hydraccatlr test 5 psl. Dlak Oltlaeedd tare lmswm 360O pal.

        ~ certify that the statements made in this report are correct and that this pump. or valve. conforms to the rules of construcdon of the ASME Code for Nuclear Power Plant Components. Seaion ill. Div. I Edidon.                                     L9~4 R~mter '75                      ~e C ~         N~                    /
    

    (Qatel EucLaar Valve Div. Bo Vaznar IN certlncste Hol~ Our ASME Card fiesta of Authorizadon No. to use the symbol exp'res tin Qwel CKRTIRCAT)ON OF DES(GN D n;nh,rmadon on ge aPVD analys(s report (Class 1 of Bo only) on fil~ at ~ Marner o 7500 f Born 4arne one dna~ r, 7 '0 Vmt N Ca. 91409 T; rone Ave .. V:n Nu"s . CA Design spec(flcadona cerdfied by (1) David 4, Xttr)le Stress analysis certified by (1 ) Bvron H. Leonard PK Slate Aeg. No. (1) SIgnature not required. Ust name only. CERT)RCATE OF SHOP INSPECT1ON I, the undersigned. holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed byL~e~ a 1 a1 ~~LE of have Inspec:ed the pump. or valve, described in this Data Report on IS ~~. and state that to the best of my knowl edge and belief, the N Cartfficste Holder has con-struaed this pump. or valve, in accordance with the ASME Code. Seaion N. By signing this card6cate. neither the Inspector nor his empioye7 makes any warranty, expressed or implied. concerning the equipment described In this Data Report. Furthermore. neither the Inspector nor hia empfoyer shall be liaol~ in sny manner for any personal Injury or property damage or a (oss of any kind arising from or connected with this inspection. 7/R

                                                                                      , /~Xi INe!'I  M-%97&                               i ~
                                                                                                           $ 4 Stats. Prav. snO Next
    

    WAsHINOTCN pusuc powER SUPPLY SYSTEM PLAN NO 2%739 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: to/26/92 Address: Oooo George Washington Way, Richland, Washington Sheet: i o(1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNF -2 AddreSS: Hanford Reservation, Benton County, Washington Richland, WA
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, P.O. JOb etC.: Washington Public Power Supply System (WPPSS)

    (b) Repair OrganiZatiOn NO, NO, .

    4. IdentifiCatian Of SyStem: Low Pressure Core Spray (LPCS) System
    5. (a) AppliCable COnStruCtiOn COde: ASME Section III Code Class 1, 1971 Edition with Winter 1973 Addenda, Code Case: None Edition with winter 1980 (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements:1980 Addenda, Code Case: N-308
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D Built Replaced or Stamped No Replacement (Yes or No)

    Code Class LPCS(l)A WPPSS LPCS(I)< P2 1982 Repair Yes, Code Class 1

    7. DeSCriptiOn Of WOrk: Modified connection with valves LPCS-V47 and LPCS-V-38. The modification work was performed as follows
    1) Cut and removed the existing connection
    2) Beveled one (1) socket end of the existing valve for butt welding
    3) Performed PT examination on the beveled end of the valve. PT examination results acceptable
    4) Beveled the existing sockolet socket end
    5) Performed PT examination on the beveled end of the sockolet. PT examination results acceptable
    6) Reinstalled the connection and made required welds
    7) Performed PT examination on the final welds. PT examination results acceptable
    8) Performed RT examination on the final circumferential butt weld. RT examination results acceptable 968-22684 (9/87)

    tfASHINGTON PUBLtc POWER SUPPLY SYSTEM PLAN NO M)739 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other x Test Pressure: Psig Test Temperature: o F COmpanent DeSign PreSSure: Psig Temperature F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repa r conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable CertifiCate AuthOriZatiOn NO.: Not appricable EXPiratiOn Date: Not Applicable Prepared by Signed by Materials d Inspection Plant Technical Manager Date 0 Date ds -
                                                                                            " > ~i.
    

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this Owner's Report during the period I- Zst 'FZto ~rD m -.mand state -to th-e best oi my knowtedge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection nspector's Signature Commissions K~4 ~ Add'i National Board, State, and Endorsements Date 968.22684 (9/87)

    XASHINCTOH PUBLIC POWER 49 SUPPLY SYSTEM PION NO 2<740 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 10/26/92 Addi'eSS: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: Residual Heat Removal (RHR) System
    5. (a) AppliCable COnStruCtiOn Cade: ASME Section III Code Class 1, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements:1980 Edition with winter 1980 Addenda, Code Case: N<08
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D Built Replaced or Stamped No Replacement (Yes or No)

    Code Class RHR(1)<C WPPSS RHR(1) AC-Pt N/A 1983 Replacement Yes, Code Class 1

    7. DeSCriptiOn Of WOrk: Fabricated and installed modified connection with valves RHR-V-157C and RHR-V-158C. The fabrication and installation work was performed as follows
    1) Fabricated carbon steel pipe nipple
    2) Performed PT examination on the final machined surfaces of the carbon steel pipe nipple. PT examination results acceptable
    3) Fabricated stainless pipe nipple
    4) Performed PT examination on the final machined surfaces of the stainless steel pipe nipple. PT examination results acceptable
    5) Beveled the socket ends of two (2) new valves for butt welding
    6) Performed PT examination on the beveled ends of both the valves. PT examination results acceptable
    7) Cut and removed the existing connection
    8) Installed pipe nipples and valves and made required welds
    9) Performed PT examination on the final welds. PT examination results acceptable
    10) Performed RT examination on the final circuinferential butt welds. RT examination results acceptable 968-22684 (9/87)

    XASHINGTON PUBUC POXER SUPPLY SYSTEM PIAN NO 2<740 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Test Pressure: Psig Test Temperature: o F Component Design Pressure: Psig Temperature: F

    9. Remarks: See attached NPV-1 Code Data Report for the foiiowing new valves RHR-V-157C, Serial No PB 1156 RHR-V-158C, Serial No PB 1157 CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI TyPe Code Symbol StamP: Not applicable CertifiCate AuthOriZatiOn NO.: Not applicable Expiration Date: Not Applicable Prepared by Signed by Materials d Inspections Plant Technical Manager Date 0 X4, Date gg. 7-f l.

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this Owner's Report during the period ~-~ -5~ toXP-~- 5'~ and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a toss of any kind arising from or connected with this inspection Commissions I spector's Signature National Board, State, and Endorsements Date HC -~ 968.22684 (9/87l

       ~ '                                                         ~   ~
                                                                              ~ ~  ~    ~
                                                                                          ~ ~
                                                                                                  ~   ~           ~ ~        ~
                                                                                                                                    ~   ~ ~
                                ~     0
                             ~      0   ~                                                                                   V'            I
                                                         ~ ' ~                        ~   ~
                                                                         ~ ~                    ~       L ~   ' I         ~      ~
                                                                                                                                            ~ ~
    

    0 0 ~ ~

                                                                                       ~
                                                              ~  ~
              ~            J                                                                                                                    ~ ~
    

    5lIIRI@i%PRM 0 ~

            ~   ~     ~                 ~   II                               I~
    

    ~ ~ ~

                                               ~ ~ I            ~  . II
                  ~ I                                                                                   0   ~   ~                  ~ ~
    

    0 ~ 0 0 I'L0.

                        ~0        0 I~
                                                                     ~ ~                      ~     ~
                                      ~   I          ~ ~                                                                       ~      ~
    
                    ~        ~
                  ~     ~
                                                                                                ~   I      ~
                                                   ~
                                                        ~ II                                                                           ~ ~
                                                                                                                        ~          ~
                                                                                                       ~ ~                                                         ~    ~              ~      ~
                          ~       ~                              ~ ~                                                           ~   ~ ~                                           ~       ~
                                                                                                                                                                                                ~ ~
          ~ '                                                                        ~ ~                                                                       ~ .
        ~     '
                                                                 ~,         ~                                                                                                  ~   ~         ~
                                                                                                                       ~         ~
    ~        ~             ~            ~      ~                                       ~     ~             ~                               ~ ~
                                                                                                             ~     ~ ~  0                                              ~ ~
    ~        ~          ~                                      ~   ~                         I~                0     ~
                                      ~    I                           ~         ~
                                                     ~     ~
                                                                                                      ~ ~
                                                                       ~         ~              ~
                                    ~        '
                                 ~       ~       +     I     ~           ~       ~                               ~   ~                   ~,      ~   . t   ~       ~                                       ~   ~
                                 ~          ~                                                                                            ~  '      ~
    

    II ~ ' ~ ~ ~ ' ~ .. ' ~

                                                                                                                        ~                     ~        ~ ~           ~                                 ~ ~
                                          ~    ~                           ~    ~                                         ~ ~
                                                                                         ~        ~                     ~    ~                                                       ~     ~     ~   '
                ~     ~                          ~       ~             ~   ..       '      ~                                                                                 ~   ~
                                                                     ~    ~   ~   ~
    

    ~ .

    PLAN NO 277f trAsHNcTOH puBUc polfER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlalona of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Dafe: 7I2tl93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Pubfic Power Supply System (WPPSS) Nudoar Power Rant (WNP) Unit: wNP-2 Address: Hanford Resorvation, Benton County, Washington
    3. (a) Work Performed by: Washkigton Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:Washington Public Power Supply System (WPPSS)
    4. IdentlfIcation of System: Service Wator (SW) System K (a) APPllcable COneflucflon Code: ASME Section lil Code Class 3, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements: 1980 Edition with winter 1980 Addenda, Coda Casa: N~
    8. Identfflcatlon of Components Repaired or Replaced and Replacemenf Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. BQIIf Replaced or Stamped No Replacement (Yes or No)

    Code Class SW(21)-2 WPPSS SW(21)-2-P1 1983 Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Replaced ortfica plate for SW-FE9A.'the replacement work was porfonnad as follows
    1) Fabricated new orifice pkrto
    2) Removed existing orifice plate from the piping system
    3) Installed new orifice phta in the piping system
    4) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2 NASHLHOTolr Pustlc PolfER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other None Test Pressure: 2t a Psig Test Temperature:72 F Component Design Pressure: sos Psrg Temperature: tso F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorlzatlon No.: Not applicable Explratlon Date: Not Applicable fD Prepared by Signed by Mate s And Inspection Manager, Materials And Inspection Date 1>~ 93 Date 7- 2.7-F3 CERTIFICATE OF INSERVICE INSPECT/ON I, the undersigned, holding a valid commlsslon Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright MutuaI Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By slgnlng this certlflcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concemlng the examinations and corrective measures described In this Owner's Report.

    Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arlslng from or connected with this Inspection. Commlsslons $5 spector's SignatUre National Board, State, and Endorsements Date

    PLAN NO 2%772 trAsHINcTOH puBUc poNER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. OHrnef; Washington Public Power Supply System (WPPSS) Date: el2I93 Address: 3000 George Washington Way. Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Vnlt: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. IdentlfIcation of System: Service Water (SW) System
    5. (a) Applicable Construction Code: ASME Section III Coda Cess 3, 1971 Edition with Winter 1973 Addenda, Coda Casa: None (b) Applicable Edltlon of AsME section xl vtlllzed for Repairs or Replacements: 19eo Edition with winter 19eo Addenda, Code Case: N408
    8. Identlflcatlon of Components Repaired or Replaced and Replacement Components Manufacturer's Name of Name of National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class SW(22)-2 WPPSS SW(22).2-P1 N/A 1983 Replacement Yes, Coda Class 3

    7. Desctlptlor1 of VYork: Replaced orifice plate for pump SW.FE~B. Tha replacement work was performed as follows
    1) Fabricated new orifice plate
    2) Removed existing orific plato from the piping system
    3) Installed new orifice plate in the piping system
    4) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2%772

                                                      ÃASHNGTOH PUBUC POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic               Pneumatic        Nominal Operating Pressure           X  Other Test Pressure: 2I5 Peig                         Test Temperature:70         F Component Design Pressure: sos       Palg       Temperature: t so4 F R Remarks:    Nona CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Applicable G
    

    Prepared by Signed by Materials And Inspecbo Manager, Materials And Inspection Date Date 8 CERTIFICATE OF INSERVICE INSPECTION l I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company

                                                                                      ~l (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described ln this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection Commissions             5"5Ã                 /VB~
    

    Inspect r's Signature National Board, State, and Endoreementa Date s- z-

    XASHINCTON PUBUC POXER SUPPLY SYSTEM PLAN NO 2-0777 FORM NIS-2 OWNER'S-REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: >>/1 7/92 Address: 3000 George Washington Way, Richland, Washington Sheet: 1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatian P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: Residual Heat Removal (RHR) System
    5. (a) AppliCable COnStruCtian COde: ASME Section III Code Class 1,1971 Edition with Winter1972 Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements: 1980 Edition with winter 1980 Addenda, Code Case: N.308
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D Built Replaced or Stamped No Replacement (Yes or No)

    Code Class RHR-V-60B Velan 414 N/A 1978 Replacement Yes, Code Class 1

    7. Description of Work: Replaced body to bonnet bolting material for valve RHR-V-60B. The replacement work was performed as follows
    1) Removed existing body to bonnet bolting material
    2) Installed new body to bonnet bolting material
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test 968-22684 (9/87)

    trASNNGTON PVBUC PolfER SUPPLY SYSTEM PLAN NO 2<777 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure ~x Other None Test Pressure: tooo Pslg TeSt Temperature: 888o F Component Design Pressure: t86o Psig Temperature: s7so F

    9. Remarks: None CERTIFICATE OF COMPLIANCE
       .We certify that the statements made in this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Appgcabie 0              O Prepared by                                             Signed by Materi    And Inspectio s                             Plant Technical Manager Date                f( f       2                        Date                fr-H i i
                                                                                           ~
    

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions I s ector's Signatvre National Board, State, and Endorsements Date 968.22684 (9/87)

    llASHNGTOH PUBllc PONKR PLAN NO 2~ SUPPLY SYSTEM FORM NISH OVYNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 7/21/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 ot1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: WNP-2 Addresi: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Bechtel Consruction, Inc, Po Box 800, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc,: c20089
    4. Identlflcatlon of System: Process Instrument (Pl) System
    5. (a) AppllCable COnatruotIOn COde: ASME Section III Code Qass 1', 1974 Edition with Winter 1975 Addenda, Code Case: None (b) APPllcable Edltlon of ASME Section XI Utlllzed for RePalrs or RePlacements:1980 Edition with Winter 1980 Addenda, Code Case: F08
    5. IdentlfIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, AS/ItE Code Component Manufacturer Serial No Board I,D. BuIIt Replaced or Stamped No Replacement P'es or No)

    Code Class" Pl(1) <S-age JCI Pl(1) ~-age N/A N/A 1983 Repair Yes, Code Qass 1 Pl(1) M-X+2I JCI Pl(1) ~-X<2f N/A N/A 1983 Repair Yes, Code Qass 1 Pl(1) AS-X4ISd JCI Pl(1) ~.X4t5d N/A N/A 1983 Repair Yes, Code Qass 1 Pl(l) AS-X4ISe JCI Pl(1) ~-X45e N/A N/A 1983 Repair Yes, Code Qass 1

    7. Descrlptlon of Work: Installed unistrut on the existing support steel. the installation work was performed as follows
    1) Installed unistrut members on the existing support steel
    2) Made required welds

    'SME Section III, Code Qass NF(1)

    PLAN NO 2<778

                                                       'rrASNNGYOH PUSUC PONtR SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back)
    

    B Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other QQ Nene Test Pressure: Pelg Test Temperature: e F Component Design Pressure: Peig Temperature: 4 F

    9. Remarks: None CERTIFICATE OF COMPLIANCE W'e certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Net apprcabte Certificate Authorization No,'ot applicable Expiration Date: Net Applicable O

    Prepared by Signed by Materials And In Manager, Materials And Inspection Date 9s Date 7-'Z7- VS CERTIFICATE OF INSERVICE INSPECTION I, the undersIgned, holding a valid commission issued by the National Board of Boiler and Pressure Vesse/ inspectors and the State ofWashington and employed by Arkwright Mutual insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                          .c   ~
    

    state to the best of my knowledge and belief, the Owner has performed examinations and taken conectlve measures described In this Owner's Report In accordance with the rerlulrements of the ASME Code, Section M. By slgnlng this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examlnatlons and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this inspection. Commissions 5dh/ 4'8Z s Signature National Board, State, and Endersernents Date

    PLAN NO 2%779

                                                           -WASHINGTON PuBUC POXKR SUPPLY SYSTEM FORM NISH OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI
    
    1. OWner". Washington Public Power Supply System (WPPSS) Date: 7/2t/93 Address: 3ooo George Washington Way, Richland, Washington Sheet:t oft
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Rant (WNP) Unit: wNP.2 Address: Hanford Reservation, Benton County, Washington
    • (e) WOrk PerfOrmed by: Bachtal Consruction, Inc, PD Box 6OO, RicMand, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: C2oo69
    4. Identlflcatlon of System: Containment Vassal
    5. (a) Applicable Construction Code: ASME Section III Code Class, 197t Edition with Summer t 972 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements: t geo Editon with Venter t 9eo Addenda, Code Case: N~
    8. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No 'oard I.D. Built Replaced or Stamped Ho Replacement P'es or No)

    Code Class Containment PDM 12764 N/A 1976 Repair, Yas, Code Chss Vessel

    7. Descrlptlon of I/I/ork: Drilled and tapped holes in the reinforcement beams for installation of electrical raceways

    'SME Section lil, Code Chss MC

    PLAN NO 2<II trASHlHGTOH PUBUC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other ~X None Test pressur'e: Pslg Test Temperature: 4 F Component Design Pressure: Pslg Temperature: 4 F R Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Applicable O 0 Signed by Materials d Inspection Manager, Materurls And Inspecbon Date 2w Date 7 2'7-53 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components described in this Owner's Report during the period to 7 and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shell be liable In any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions rU I spector's Signature National Board, State, and Endorsements Date

    WASHINGTON PUBLIC POWER SUPPLY SYSTEM PLAN NO 2<780 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 1o/26/92 Address: 3ooo George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: Residual Heat Removal (RHR) System
    5. (a) AppliCabie COnStruCtiOn COde: ASME Section III Code Class 1, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements:198o Edition with winter 1980 Addenda, Code Case: N<08
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D Built Replaced or Stamped No Replacement (Yes or No)
                                                                                                                                 'ode Class RHR(1)-4B               WPPSS              RHR(1) <B-P 1            N/A                   1983       Replacement       Yes, Code Class 1
    
    7. Description of Work: Fabricated and installed modified connection with valves RHR-V-157B and RHR-V-158B. The fabrication and installation work was performed as follows
    1) Fabricated carbon steel pipe nipple
    2) Performed PT examination on the final machined surfaces of the carbon steel pipe nipple. PT examination results acceptable
    3) Fabricated stainless pipe nipple
    4) Performed PT examination on the final machined surfaces of the stainless steel pipe nipple. PT examination results acceptable
    5) Beveled the socket ends of two (2) new valves for butt welding
    6) Performed PT examination on the beveled ends of both the valves. PT examination results acceptable
    7) Cut and removed the existing connection
    8) Installed pipe nipples and valves and made required welds
    9) Performed PT examination on the final welds. PT examination results acceptable
    10) Performed RT examination on the final circumferential butt welds. RT examination results acceptable 968-22684 (9/87)

    XASHINGIOH 1'UBUC PolrEtt SUPPLY SYSTEM PLAN NO 2%780 FORM NlS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Test Pressure: Psig, Test Temperature F Component Design Pressure: Psig Temperature: F

    9. Remarks: See attached NPV-1 Code Data Report for the following new valves RHR-V-157B, Serial No PB 1158 RHR.V-158B, Serial No PB 1159 CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable EXpiratiOn Date: Not Applicable Q

    Prepared by M - ~ Signed by Materials d Inspections Plant Technical Manager Date tO 2%%d Date ~- '7.52 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the componehts described in this and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions 5 4cJ Inspector's Signature National Board, State, and Endorsements Date ld'- cr 968.22684 (9/87)

                                    ~     ~
    

    r ' ~ 'r ~ ~ r ~ ~

                                      ~ ~  ~
    

    r ~ ~ ~

                                                                             ~ ~                 l~   ' l       ~    ~
                                                                                                                               ~ ~
                                                                                                            ~ ~
    

    0 0 ~

                                                               ~  ~
    

    I I ~ g

                                                                 /      r                  v     j I
    

    0

     ~       ~    ~   ~     ~
         ~ ~
                                                   ~ I~           ~ .       I I
              ~ ~
                        ~ ~     ~                                                                0  ~   ~              ~ ~ ~
    

    0 ~ p i r fr ~ ~

                                               )
                                                                      ~    ~                 ~ ~                                ~, ~
                                          ~  I          ~ ~         ~    ~    ~                                     ~,     ~
    

    e ~

                                                ~
                                                      ~   I                  ~          ~                                                 ~ ~    I
                                                                                                                             ~            ~
                                                                                                        ~  ~                                                                                  ~    ~
                                                                                                                                                                                                         ~   ~
                          ~    ~                                ~ ~                                                                  ~   ~ ~
     ~   0       ~                      ~       4                                      ~ ~                                                                              ~  .
       ~       ~            ~    j     ~
                                                                ~     .      ~                                                                                                          ~ ~       ~
                                                                                                                            ~          ~       ~
    

    ~ .

           ~               ~,        ~      ~                                            ~      ~            ~
                                        ~ ~                                                           a        ~     ~  ~    0     ~         ~
    

    ~ ~ ~ ~ ~ o ~ ~

                                                                        ~         ~
                                                  ~     ~                                                 ~          ~  ~
                                                                                                          ~
                                                                        ~         ~               ~
                    ~   '
                                              ~     ~       ~             ~       ~                                ~    ~                       ~    I ~      ~     ~        ~                                   ~ ~ ~
                                                                                                                                                     ~   ~        ~   ~
                  ~ $ ~      II ~       0                                                                             ~
                                                                                                                                ~              ~   ~                               ~   ~                       ~  ~
                                                                                                                             ~                             ~ ~            ~  ~                          ~  ~
                                       ~    ~                               ~    ~                                              ~    ~
           ~          ~                                                                    ~                                 ~     ~                                                        ~   ~    ~ ~
             ~     ~                          ~       ~                 ~   ..       '       ~                                                                                       ~   ~
                                                                    \      0   ~   \                     ~ '              t        ~                            ~       ~      0 1 g/
    

    WASHINGTON PUBUC POWER 4Q SUPPLY SYSTEM P IAN NO 241782 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by'he Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 10/26/92 Address: 3000 George Washington Way, Richhnd, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) . Unit: wNP-2 Addf'ess: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: High Pressure Core Spray(HPCS) System
    5. (a) AppliCable COnStruCtian COde: ASME Section III Code Class 2, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) AppliCable Editian Of ASME SeCtian XI UtiliZed fOr RepairS Or ReplaCementS: 1980 Edition with Winter 1980 Addenda, Code Case: N-308
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No . Board I.D Built Replaced or Stamped No Replacement (Yes or No)

    Code Class HPCS(t)-4CL2 WPPSS HPCS(1) ACL2-P2 N/A N/A 1982 Repair Yes, Code Class 2

    7. DeScription of WOrk: Modified connection with valves HPCS-V-713 and HPCS-V-714.'The modification work was performed as follows
    1) Cut and removed the existing connection
    2) Beveled one (1) socket end of the existing valve for butt welding
    3) Performed PT examination on the beveled end of the valve. PT examination results acceptable
    4) Beveled the existing sockolet socket end
    6) Performed PT examination on the beveled end of the sockolet. PT examination results acceptable h
    6) Reinstalled the connection and made required welds
    7) Performed PT examination on the final weld. PT examination results acceptable
    8) Performed RT examination on the final circumferential butt weld. RT examination results acceptable 968-22684 (9/87)

    WASHINGTON PUBUC POWER SUPPLY SYSTEM PLAN NO 2<782 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Test Pressure: Psig Test Temperature: F Component Design Pressure: Psig Temperature: o F

    9. RemarkS: None CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repa'r conforms to the rules of the ASME Code, Section XI Type COde Symbal Stamp: Not applicable Certificate Authorization No.: Not applicable EXpiratiOn Date: Not Applicable O

    Prepared by Signed by Materials And InspectIo s Plant Technical Manager Date to M '92. Date /o 'O7 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this

                                                                   /
    

    and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions W5M~ I spector's Signature National Board, State, and Endorsements Date 8'-$4'- 968.22684 (9/87I

                                                                                                                          ~ ~
                                                                                                                                        ~                   i
                                                          ~                   ~             ~    ~                                                                              ~ ~
                                    ~    ~                                             5 ~
         ~ ~              ~ ~ ~             ~                                                                     5            ~  ~
                               ~    ~                                              ~ ~
         ~ ~                      ~    ~                    5                                               5         ~   ~
                                                   ~      ~                          ~  ~                                  ~ ~                                        ~   1  ~       ~  ~
               -  ~        ~                                                                     ~ ~                                    ~  ~          ~       ~                ~ ~
               ~ ~         ~               ~                                       ~ ~                                           ~ ~          5                   ~    5   ~                          ~ ~ 5     ~ 5
       ~       ~ ~         ~               ~                                                                                                                                                            ~   ~ ~
                                ~  ~                             ~
                                                         ~ ~                              ~           ~   ~         ~             ~         ~          ~                           ~       ~ ~
                                                                                                                                                                                                    ~       ~
      ~      ~ ~                                                                                                                       s  ~         ~                                                     ~    ~
                                               ~    ~
       ~-           ~   ~       ~                                 ~     ~   5  '
                                                                                                                ~       5    ~       ~ ~   ~    ~ ~   ~  ~ ~                          ~   ~
    

    5 4 ~

                             ~ ~ ~         ~    ~  ~               '                ~
                    ~ '                                         ~         5  ~   ~           ~ ~ I   ~
                            ~
                                     '       ~
                                 ~  ~  ~         ~    ~ ~
    

    i ~ ~ 5 5 ~ k ' 5 5 ~

                          ~    ~                               ~     5   ~                              ~     ~                                                                               ~ 5 ~
    

    xAsHIHGTOH pUBUc potNER SUPPLY SYSTEM PtAN NO F06 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure x Other Test Pressure: tooo Psig Test Temperature: 64so F COmpOnent DeSign PreSSure: 3600 Psig Temperature: too F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repair/replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable EXpiratiOn Date: Not Applicable b I Prepared by Signed by Materi s And Inspecti ns Plant Technical Manager Date tl Date u-r S- ~g CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this cLII and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI ~

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or properly damage or a loss of any kind arising from or connected with this inspection A. n pector's Signature Commissions 5 4J k~ National Board, State, and Endorsements Date //- '7 C- .968-22684 (9/87)

    PLAN NO2~f F tfABHtMOTOH PUBUC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. OWner. Washington Public Power Supply System (WPPSS) <<Date: 7/28/93 Address: 3000 George Washington Way,-Richland, Washington Sheet:1 of 1
    2. Plant: Washington Pubic Power Supply System (WPPSS) Nuclear Power Rant (WNP) Unit: wNP-2 Address: Hanford Reseivrrtion, Benton County, Washington
    • (a) Wold Performed by: washington Public Power supply system (wPPss), 3000 George washington way, Organlzatlon P.O. No, Job No, etc,: Washington Pubic Power Supply System (WPPSS)

    Richland, wA (b) Repair

    4. IdentNcatlon of System: Controlled Chilled Water (CCH) System
    5. (a) APPIICable COnStruCtlOn COde: ASME Section III Code Case 3, 1977 Edition with Summer 1977 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements:1980 Edition with Winter 1980 Addenda, Code Case: N408
    8. Identlflcatlon of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No 'Board I.D. Built Replaced or Stamped No Replacement P'es or No)

    Code Class CCH-RV-2A Crosby N6303240~8 N/A 1980 Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Replaced disc for relief valve CCH-RV-2A. 'The replacement work was perforrred as follows
    1) Removed existing disc from the relief valve
    2) Installed new disc st the relief valve

    PLAN HO 2~1 trASHlHGTOM Pllslrc Porrma SUPPLY SYSTEM FORM NISH OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other ~X Test Pressure: Psig Test Temperature: o F Component Design Pressure: Pslg Temperature: o F

    9. Remarks: None CERTIFICATE OF COMPVANCE Mfe certify. that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not applicable Certlflcate Authorlzatlon No.: Not applicable Exp!ration Date: Not Applicable Prepared by Signed by
                                   '                                                 Manager, Materials And Inspection Ma       And Inspectron Date                                                    Date                7-SS'- Pg CERTIFICATE OF INSERVICE INSPECTION I, the undersigned,    holding a valid commlsslon Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examlnatlons and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By slgnlng thIs certlflcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report.
    

    Furthermore, neither the Inspector nor his employer shell be liable In any manner for any personal InJury or property damage or a loss of any kind arlslng from or connected with this Inspec tlon 3'ommlsslons SSSLCf'/8X National Board, State, and Endorsements In s Signature Date 7 Xd-

    PLAN NO 2~19 XAstQNGTOH PUBUC Pot(ER SUPPLY SYSTEM FORM NIS-2 0)/f/NER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Prof/felons of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS)
                                                                                                                     'ate:  7/29/93 Address: 3000 George Washington Way, Richland, Washington                                                      Sheet:1 of1
    
    2. Plant: Washington Public Power Supply System (WPPSS) Nuckier Power Rent (WNP) UnIt: WNP-2 Address( Hanford Reservation, Benton County, Washington S. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Wey, RIchland, WA (b) Repair Organtzatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon of System: High Pressure Core Spray (HPCS) System
    5. (a) Applicable Construction Code: AsME section III code casa 2,1974 Erfition wffliwinter 1974 Addenda, code case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements( 1980 Edfbon with Winter1980 Addenda, Code Case: N~
    6. Identlflcatlon of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASMf Code Component Manufacturer Serial No Board I.D. Bl(lit Replaced or Stamped No Replacement (Yes or No)

    Code Class HPCS-RYE Lonergen 509258-73-1 N/A N/A 1978 Yes, Coda Class 2

    7. Descrlptlon of Work: Installed test port for relief valve HPCS+V~. The work wes performed as follows
    1) Surface finlshed the raised face on the pipe flenge
    2) Machined grooves in the refief valve discharge flang to accommodate the '0'ings
    3) Drilled hole in the relief valve discharge flange outer edge
    4) Instalbd mala connector end made required weld
    5) Performed PT examination on the final weld. PT examination results acceptable
    6) Installed cep on the male connector
    7) Performed pressive test to confirm pressure boundary kitegrfty. No evidence of leakage during the pressure test

    PLAN NO 2~1 tfASHlMGTON PVBUC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressurr 'ther Test Pressure: Psig Test Temprraturr: ~ F Component Design Pressure: t 575 Pslg Temperaturr: 45co F

    9. Remarks: 'ominal operating prossuro tost on the relief valve Inlet ftanged loint test pressure of 15.4 Psig at 7so F. Appendix J (LLRf) tost on tho relief valve discharge flangod loint, test press'f 35.2 Pslg at 75.4 F CERTTFICA TE OF COMPVANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicablo Expiration Date: Not Appt'cable O

    Prepared by Signed by Materials And Inspection Manager, Materials And Inspectim Date 72-1 53 Date -z '- 9Z CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                                      '7 f                 ~7 state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the rerlulrements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising fiom or connected with this Inspection Commissions                  SM                    4Zz In        s Signature                                                  National Board, State, and Endorsements Date             7- Zd"
    

    trAsHINGTOH pusuc powER SUPPLY SYSTEM PlAN NO 24820 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Require'd by the Provisions of the ASME Code Section Xl

    1. OWner: Washington Public Power Supply System (WPPSS) Date: >>/5/92 AddreSS: 8000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNr -2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. Identification of System: Main steam (Ms) system
    5. (a) AppliCable COnStruCtiOn COde: ASME Section ill Code Class 1, 1974 Edition with Summer 1975 Addenda, Code Caso: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements:198o Edition with winter 1980 Addenda, Code Case: N<08
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D, Built Replaced or Stamped No Replacement (Yes or No)

    Code Class MS-Vdt Borg Warner 28722 N/A N/A 1978 Repair Yes, Code Class 1

    7. Description of Work: Removed scratches on the disc seating surface for valve Ms-V<1. Ibo repair work was performed as follows
    1) Removed scratches on the disc seating surface by machining
    2) Per/ormed PT examination on the final machined seating surface. PT examination results acceptable 968.22684 (9/87)

    WASHIHGToH pusuc powER SUPPLY SYSTEM PLAN NO 2%820 FORM NIS-2 (8ack) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other x None Test Pressure: Psig Test Temperature P Component Design Pressure: Psig Temperature: P

    9. RemarkS: None CERTIFICATE OF COMPLIANCE We, certify that the statements made in this Owner's Report are correct and this repa r conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not appgcable EXpiratiOn Date: Not Applicable Prepared by Signed by Materials nspectio s Plant Technical Manager Date tl G 2 Date //-C -fK CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this Owner's Report during the period M 'F z- to /u ~ and state to the best of my knowledge and belief, the Owner has performed examinations and aken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions 'PS S spector's Signature National Board, State, and Endorsements Date /' 2 968.22684 (9/87)

    XASHlNGTON PVSUC PotrER SUPPLY SYSTEM PIAN NO 2~26 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: >>/24/92 Address: 3ooo George Washington Way, Richland, Washington Sheet: 1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) wNP-2 'nit:

    Address: Hanford Reservation, Benton County. Washington

    3. (a) WOrk PerfOrmed by: Bechtel Construction, Inc, PO Box 600, Richland, WA (b) Repair Organization P,O. No, Job No, etc.: c2oo69
    4. IdentifiCatiOn Of SyStem: Off Gas (OG) System
    5. (a) AppliCable COnStruCtian COde: ASME Section III Code Qass 3, 1971 Edition with no Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utilized for Repairs or Replacements: 198o Edition with winter 1980 Addenda, Code Case: N408
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class OG-HX-1 B GE 223717 57776 N/A 1974 Repair Yes, Code Qass 3

    7. Description of Work: Plugged tube in OD HX-1B heat exchanger. The repair work was performed as follows
    1) Machined tube plugs to the required dimensions
    2) Installed tube plugs and made required seal weld
    3) Performed PT examination on the final seal welds. PT examination results acceptable

    ~ 968-22684 (9/87)

    lfASHINGTOH PUSLIC POXER SUPPLY SYSTEM PLAN NO 2%826 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other Test Pressure: Pslg Test Temperature: o F Component Design Pressure: Pslg Temperature: F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not appgcable Certificate Authorization No.: Not appgcable EXpiratian Date: Not Applicable Prepared by 4 Signed by Materials d Inspectio Manager, Plant Technical Date Date rr ->V-e.

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions 5~C spector's Signature National Board, State, and Endorsements Date 968.22684 (9/87)

    WASHINGTON PUBUC POWER Qj SUPPLY SYSTEM PLAN NO 2~51 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 9/28/92 AddresS: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit:WN -2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatian P.O. NO, Jab NO, etC.: Washington Public Power Supply System (WPPSS)
    4. Identification of System: Residual Heat Removal (RHR) System
    5. (a) AppliCable COnStruCtiOn COde: ASME Section III Code Class 2, 1971 Edition with Summer 1973 Addenda. Coda Case: None (b) Applicable Edition of AS ME Section XI Utilized for Repairs or Replacements: 1980 Edition with winter 1980 Addenda, Code Case: F08
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement (Yes or No)
                                                                                                                             ~ Code Class RHR.FCV-64B             Fisher                 6069710                                     1977          Repair        Yes, Code Class 2
    
    7. Description of Work: Removed surface defects on tho valve plug seating surface for valve RHR-FCV<4B. The repair work was performed as follows
    1) Removed surfaco defects on the valve plug seating surface by machining
    2) Performed PT examination on the final machined surface on the valve plug seating surface. PT examination results acceptable
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during tho pressure test 968-22684 (9/87)

    XASHtNGTOH PUBUC PONER SUPPLY SYSTEM PIAN NO 2~51 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure ~x Other None Test Pressure: 198 Pslg Test Temperature: 72.3 F Component Design Pressure: soo Pslg Temperature:368 F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section XI TyPe Code Symbol StamP: Not applicable Certificate Authorization No.: Not applicable EXpiratiOn Date: Not Applicable Prepared by 0

    Mater'als And Inspections Signed by Plant Technical Manager p-At-5" O. Date 2. Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certTilcate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions pector's Signature National Board, State, and Endorsements Date 968-22684 (9/87)

    xAsHIHGTON pusUc poNER SUPPLY SYSTEM PLAN NO 24852 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: >>/2/92 AddreSs: 3000 George Washington Way, Richland, Washington Sheet: 1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 AddreSs: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatiOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: Residual Heat Removal (RHR) System
    5. (a) AppliCable COnStruCtiOn COde: ASME Sect'on III Code Class 2,1971 Edition with Summer 1973 Addenda, Code Case: None (b) AppliCable Editian Of ASME SeCtian XI UtiliZed fOr RepairS Or ReplaCementS: 1980 Edition with Winter 1980 Addenda, Code Case: N408
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board- I.D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class RHR-V-27B Velan 355 N/A N/A 1976 Replacement Yes, Code Qass 2

    7. Description of Work: Replaced wedge for valve RHR-V-27B. lee replacement work was performed as follows
    1) Removed existing wedge from the valve
    2) Installed new wedge in the valve
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test 968-22684 (9/87)

    WASMINCTON PUSLLC POWER SUPPLY SYSTEM PLAN NO 2%852 FORM NJS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure x Other None TeSt PreSSure: t98 Pslg Test Temperature: 72.3o F Component Design Pressure: 5oo Pslg Temperature: 358'

    9. RemarkS: See attached N.2 Code Data Report for new wedge, Serial No 3675 C ERTI Fl CATE OF COMPLIANC E We certify that the statements made in this Owner's Report are correct and this repiacement conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not appticabte EXPiratiOn Date: Not Applicable C

    Prepared by Signed by Materials d Inspection Plant Technical Manager Date lt > 'I2. Date // r ci CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this

                                                                  ~//.
    

    and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions bu I ector's Signature National Board, State, and Endorsements Date l/~$ - P~ 968-22684 (9/87)

    FORM N-2 CERTIFICATE HOLDERS'ATA REPORT FOR IDENTICAL~ NUCLEAR PARTS AND APPURTENANCES 9Z 42 I >.'Fr<" SP""rP> As Required by the Provisions of the ASME Lode, Section!II b'neine WASHINGTON G Not to Exceed Ono Day's Production PUBLIC POWER SUPPLY SYSTEM P.O.BOX and adrrreaa or rrpt ceiriric te Holder l

                                                                                                                     ~    ~          968 itjli~
    

    RICFiLAND, WASH. 99352 Pg. 1 of ltnu ectured for tnkme and address ol Pvrcnkaerl WPPSS. VNP 2 OPS NORTH POWER PLANT LOOP RICK,ANDk WASH 99352 USA

    3. Loca'.!on of installation IT.2(M:28 (name and addiekkl r 4 T P2 33 1 I N8/C SA 1 05 70'00 (MIN ) N/A 1992 Imat'I. $ oec. no.l ttenkke suenctnf tcpfn (year trvkrl ldrewino no.l 5ASMB Cd s li(O1 1 97 1S'73N-CLASS:2 leditionl leod ends carel tcrakrl N/A rood e Case no J N/A .

    Revie(on N/A . N/A

    6. Fabric ted in accordance with Cons:. Soec. {Oiv. 2 onlyl Oat'no.l 6 300@ BB GATE VALVE WEDGE MAT L HEPT No ~ J3232/T17910
    7. Remarl.s:

    NOTE: MATERIAL SPEC. SUPPLIKl IS TO ASME SEC.II P'RT-A CODE EDITION 1986 tiDDENDAt NONE

    8. Norn. thickness {in.)
    9. When applicable, A~

    Certificate Min. design thickness (in.) Holders'c.a Reports are

                                                                                   ~~
    

    attached for each Oia. (O {ft & in.) item of this report: M~ Length overall (ft & in.] ~~ Part or Appurtenance National Part or appurtenance National Serial Number Board No. Serial Number Board No. in Numerical Order in Numerical Order WEDGE SN: fr 3675. N/A (26) (2) (27) (3) {28) (4) (29) (5) (30) {6) 0 (31) (7l (32) {8) (33) (9l l34) {10) l35) (11) {36) (12) {37) (13) {38)

          .{14)                                                                                  (39).
    

    (15). (40) l16) (41) ('l 7) i42) {18) {43) (19) (44) (20) (45) (21) {46) (22) (47) (23) (48) (24) l49) (25) {50) 0F

    10. Oesign pressure ~ 6 ii1 0F Hydro test pressure lwr>>llkeoeeaorel at temp.

    is included on each sheet. (3l each sheet is numbered and the number ol sheets is recorded at the top ol this form. This form (800040) mey be obtained from the order oe pt., ASME, 22 Lew orive, 8os 2300. Fkirlield. NJ 07007 2300. it 2f88)

    FORM N-2 (Back Pg. 2 of ) Certificate Holder's Serial Nos. through CERTIFICATION OF DESIGN Design specifications certified by N/A P Seeee R II. o. Iwt>>n eootecsole) N/A I Seeee Ree o. certified by Design report (when city((CSOlel / CERTIFICATE OF COMPUANCE We certify that the statements made in this report are correct and that this lthesel conforms to the rules ot construction of the ASME Code. Section III, Division I. N-2798-2 (NPT) Expires 2 HAY 1992 NPT Certificate of Authorization No. Date +~ + ~~ Name YfKAN INC. (t(PT Cenereeete t(O(Ceil g E.CRBUGUIS p ~ ( thoneec Ieolesehtsttel

                                                                                                                                                        /~
    

    CERTiFICATE OF INSPECTION I. tn underplgned. holding a valid commission i sued the National Board of Boiler and Pressure Vessel Inspectors and the'State or Province of and employed by of have inspected these items described in this Data Report o +, and state that to the best of.my knowledge and belief, the Certificate Holder has fabricated these parts or app rten nces in ac rdance with the ASME Code, Section III, Division 1. Each part listed has been authorized for stamping on the date shown above. By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or propeny damag loss of any kind arising from o nnected with this inspection. MAR( HASID JACQUES D.t. >~- Sig Commissions

                                                                                                                       +cptC1M IGan, ta             Q~ Qj                K1 (AII(honeed Ineoeciotl                                       (NSA  M, linc( encotsettlellisi en45(ete oe(ttoep, sn4 no,l
    

    WASHINCION PUBLIC POWER Qj SUPPLY SYSTEM PLAN NO 2%853 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 11/24/92 AddreSS: 3000 George Washington Way, Richland, Washington Sheet:toft
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) WNP-2 'nit:

    Address: Hanford Reselvafon, Benton County, Washington

    3. (a) Work PerfOrmed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganiZatian P.O, NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. IdentifiCatiOn Of SyStem: High Pressure Core Spray(HPCS) System
    5. (a) AppliCable COnStruCtiOn COde: ASME Section III Code Class 2, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edition of AS ME Section XI Utilized for Repairs or Replacements: 1980 Edition with winter 1980 Addenda, Code Case: N<08
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of M anufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement {Yes or No)

    Code Class HPCS(1) <CL2 WPPSS HPCS(1) ACL2-P2 1982 Replacement Yes, Code Class 2

    7. Description of Work: Replaced pipe piece for relief valve HPCS.RES inlet piping. The replacement work was performed as follows
    1) Cut and removed the existing pipe piece
    2) installed new pipe piece
    3) Made required socket welds
    4) Performed PT examination on the final socket welds. PT examination results acceptable
    5) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test 968.22684 (9/87)

    xAsHlrrGTorr pusUc polfER SUPPLY SYSTEM PLAN NO 2%853 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic x Pneumatic Nominal Operating Pressure Other Test Pressure: 2000 Psig Test Temperature: 8t.6 F Component Design Pressure:1575 Psig Temperature: 2t2o F

    9. Remarks: None CERTIFICATE OF COMPLlANCE We certify that the statements made in this Owner's Report are correct and this replacement conforms to the rules of the ASME Code,'Section XI" Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Applicable 0

    Prepared by Signed by Materials And Ins ection Manager, Plant Technical Date t L Date ir-a%-'FM CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure

                                                                      ~~
    

    Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have. inspected the components described in this Owner's Report during the period -/ . to and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions AS l spector's Signature National Board, State, and Endorsements Date 968-22684 (9/87)

    trAQruroTorr puBUC porrER PLAN NO 2~ SUPPLY SYSTEM FORM NISH OWNER'S REPORT FOR REPA/RS OR REPLACEMENTS. As Required by the Provlslons of the ASME Code Section XI

    1. Ottrner: Washington Public Power Supply System (WPPSS) Date: msN3 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Su pply System (WPPSS) Nudear Power Rant (WNP) Unit: WNr -2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 30oo George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:Washington Publ'c Power Supply System (WPPSS)
    4. Identfflcatlon of System: Reskfuai Heat Removal (RHR) System S. (a) ApPllCable COnStruCtlOn COde: ASME Section III Code Cess 2, 1974 Edition with Winter 1974 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements: 1 seo Edition with Winter 1980 Addenda, Code Case: N~
    6. IdentlfIcation of Components Repabed or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board LD. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class RHR.RV-25A Loner gan 509258-74-1 1978 Replacement Yes, Code Class 2

    7. Descrlptlon of Work: Replaced disc for relief valve RHR-RV-25A. M replacement work was performed as follows
    1) Removed existing disc from the relief valve
    2) Installed new disc in the relief valve
    3) Reinstalled the relief valve
    4) Performed pressure test to con5rm pressure boundary integrity. No evidence of leakage during the pressure test
                                                         'NASHlHGTOM PUB1JC POXER PLAN NO       2~
    

    SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tesfs Conducted: Hydrosfatlc Pneumatic Test Pressure: 35.g perg

                                                               ~      Nominal Operating Pressure Tesf Temperature: eo.s
                                                                                                           ~  F Other Component Design Pressure:          5oo peg            Temperature: 45rf'
    
    9. Remarks: 'ppendix J (LLRT) test on the relief velve discharge ttanged joint CERTIFICATEOF COMPVANCE We certify that fhe stafements made In this Owner's Report are correct and this'reptacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Net appl'cable Certificate Authorization No.: Net applicable Explrafion Date: Net Ap pllcabte O

    Prepared by Signed by Materials And n Manager, Materials And Inspection Date 2 Date 7-Z-CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken conective measures described In this Owner's Report In accordance with the regulrements of the ASME Code, Section N By signing this certificate neither the Inspector nor his employer makes any wananty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this InspectIon Commissions 5 Ins s SignatUre National Board, State, and Endoraernenta Date 7A

    PLAN NO 2~II trASHIHcTOM pusuc potrER SUPPLY SYSTEM FORN NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Sect!on XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 7I2tl93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: wNP-2 Address: Hanford Reservation, Bonton County, Washington
    3. (a) Work Performed by: Bochtel Consruction, inc, PO Box 600, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: c20089
    4. IdentlfIcation of System: Servtce Water (SW) System
    5. (a) Applicable Construction Code: ASME Section III Code Qass 3, 1974 Edition with Winter 1978 Addenda, Code Case: None (b) APpllCable EdltlOn Of ASME SeCtlOn XI tjtIIIZed fOr RePalrS Or RePlaCemente: 1980 Edi5On With Wrnter 1980 Addenda, Code Case: N408
    5. Identiflcatlon of Components Repaired or Replaced end Replacement Components Name of Name of Manufacturer's Netlonel Other Year Repaired, ASME Code Component Manufacturer Serial No Boerd I.D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class SW(35).2-1 BF Shaw S W(35) 1 N/A 1978 Repair Yes, Code Cfass 3

    7. Descrlptlon of Work: Installed galvanic ground connection on 30'ervice Water (SW) syphon piping. The work was performed as follows
    1) Installed threaded rod on the pipe
    2) Made threaded rod to pipe weld

    PLAN HO 2~9 XASHIXGTOX PUBLIC POWER SUPPLY SYSTEM FORM HIS-2 OMfNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Hominal Operating Pressure Other X None Test Pressure: pslg Test Temperature: F Component Design Pressure: petti Temperature'o F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certlflcate Authorization No.: Not applicable EXplratIOn Date: Not Apprcable 0

    Signed by Mater' And inspection Manager, Material s And Inspection Date 2 Date 27>> CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the Hatlonal Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Aritwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components descrIbed in this Owner's Report during the period 8 Zd P to T P7 53'nd state to the best of my knowledge and belief, the Owner has performed examinations and taken ASME Code, SectIon ¹ corrective measures described ln this Owner's Report ln accordance with the requirements of the By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal lnJury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions Inspector's Signature National Board, State, and Endorsements Date

    PLAN NO 2~80 trA5HBlGTOH PUBLIC POXElt SUPPLY SYSTEM FORM HIS-2 OWNER'S REPOR7 FOR REPAIRS OR REPLACENEN7S As Required by the Provlslons of the ASNE Code Section XI

    1. Ottrner: Washington Public Power Supply System (WPPSS) Date: 7I2tl93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of>
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Bachtal construction, Inc, Po Box 600, Richhnd, wA (b) Repair Organlzatlon P.O. No, Job No, etc.: c20069
    4. Identlflcatlon of System: Service Water (SW) System
    5. (a) Applicable Construction Code: ASME Section III Coda Qass 3, 1974 Edition with Winter 1976 Addenda, Coda Casa: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements: 1980 Edition with winter 1980 Addenda, Coda Case: N408
    5. Identlfication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board /.D. Built Replaced or Stamped No Replacement P'es or No)

    Code Class SW(35).2-1 BF Shaw SW(35) 1 N/A 1978 Replacement Yas, Coda Qass 3

    7. Descrlptlon of Work: Removed valves SW V 168B and SW V 1698. 7ha work was performed as follows
    1) Cut existing pipe and removed both the vent valves
    2) Installed new pipe cap

    PLAN NO2M60 xAsHIIIGTox pusttc poxER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) S Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X None Test Pressure: Paig Test 7emperature: 4 F Component Design Pressure: palg Temperature: 4 F

    9. Remarks: Nona CERTIFICATE OF COIHPLIANCE We certify that the statements made In this Owner's Report are correct and this reptacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not appt elle Certificate Authorization No.: Not applicable Expiration Date: Not Applcable ct r Prepared by Signed by Materials And Inspection Manager, Materials And Inspection Date 9 Date 7- z7- 3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual insurance Company
                                                                 ~F (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components to state to the best of my knowledge and belief, the Owner has performed examinations and taken
                                                                                                    '7                  arid corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section N.
    

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions S5 Inspects Signature National Board, State, and Endcaements Date

                                                                                                                      ~ ~
    

    r ~ ~ r 5 ~ r ~

                                                                                                                                                               ~ ~
                                                      ~             ~               ~ ~
    

    ' ~ ~ ~ ~ ~ ~ ~ ~

                                 ~     ~                       ~      ~       ~ ~
    

    ' I ~

       ~                             ~   ~           ~                            ~
                                                   ~     ~                      ~    ~                                                                 ~ ~  t       ~ ~            ~  ~         I       I ~
     ~           ~   .        ~      ~                     ~                         ~         ~ ~                             ~  ~                           ~ ~
                            ~        ~                                         ~   I        ~ ~        ~
         '      o                                                             ~ ~                                                                                                       ~ ~         ~ ~
     ~       ~ ~                           ~       ~         ~                                                          ~   ~         ~          ~        ~                          ~    ~   I  ~
           ~  ~        I I        ~ ~
                           ~         ~        ~          ~ ~                            ~             ~    ~       ~      ~        ~      ~                        ~     ~ ~
                                                                                                                                                                                   ~          ~                          ~ ~
    ~    0 ~                                                                                                                  r  ~    ~                                          ~          ~     ~                    ~  ~
                                                                                                                                                                                                                    ~      ~
                                                                                                                                                                                                            ~ ~
                                                                                                                                                                                                                ~ ~
    ~-            ~      ~        ~                                ~ ~      ~                   ~  ~                                                 ~     ~     ~        ~  I   ~
                   ~       ~                ~  ~                  I ~
                     ~           I     '         \     ~    I   ~ ~     ~                  I ~                 ~ ~
                             ~           '
    

    II ' I ~ ~

                                                                                         '               ~                          I   I    ~     '        '       ~   ~
                          ~           ~
                             ~  ~ ~                                                              I  I        ~
    

    trASHINGTOH PUBUC POWER SUPPLY SYSTEM PLAN NO 2%869 FORM NIS-2 (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other TeSt PreSSure: Pslg Test Temperature: ~ F Component Design Pressure: tso Psfg Temperature:t76 F

    9. Remal'ks: Performed open flow test CERTIFICATE OF COMPLIANCE We certify that the statements made in this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable CertifiCate AuthOriZatiOn NO.: Not applicable EXpiratiOn Date: Not Applicable Prepared by Signed by M erials nd Inspection Plant Technical Manager Date LI > Date //-C-i~

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure f~/. .- Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual System) of Norwood, Massachusetts have inspected the components described in this

                                                 ~F                      9 and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.
    

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions I spector's Signatvre National Board, State, and Endorsements Date 968-22684 (9/87)

    PLAN NO 2~71

                                                                     'NASHNGTON PUBUC PoirER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI
    
    1. Owner: Washington Pubfic Power Supply System (WPPSS) Date: 7/29/93 Address: 300o George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plat) t: Washington Public Power Supply System (WPPSS) Nuclear Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 300O George Washington Way, Richland, WA tb) Repair Organlzetlon P.O. No, Job No, etc.: Washington Pubfic Power Supply System (WPPSS)
    4. Identlflcatlon of System: Service Water (SW) System K (a) APPIICable COnatruCtlOn COCfe: ASME Secfion III Code Class 3, 1971 Edition with Winter 1973 Addenda, Code Case: Nona p) Applicable Edition of ASME Section XI Utlllzed for Repairs or Replacements:1980 Edition with Winter 1960 Addenda, Code Case: N~
    8. Identlfication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No 'oard '.D. Built Replaced or Stamped No Replacement (Yes or Ho)

    Code Class SW(1)-2 WPPSS SW(1)-2%1 N/A Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Installed restricting orifice pate for SWRO-1 2K 'nie replacement work was performed as follows
    1) Fabricated new restricting orifico plate
    2) Removed existing spacer ring from the piping system
    3) Installed new restricting orifice plate in the piping system
    4) Performert pressure test to confirm pressure boundary kttegrity. No evidence of leakage during the pressure test

    PLAN NO 2~ lrASHIMQTOM PUBLIC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other Test Pfessufet 215 Pslg Test Temperature: sao F Component Design Pressure: sog P< Temperature:150 F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Ap ptcable Prepared by Signed by Materials Inspection Manager, Materials And Inspecbon Date Date 7-zo -SG CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by ArloNright Mutual Insurance Company (Factory Mutual Engineering Association) of Nontvood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations encl taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report.

    Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions In s SignatUre National 8oard, Stale, and Endorsements Date g

    PLAN NO 2~73 xlsruNGTOH pvsuc poxER SUPPLY SYSTEM FORM HIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by Ne Provlslons of the ASME Code Section XI

    1. OWnerl Washington Public Power Supply System {WPPSS) Date; 7/21/93 Address: 3000 George Washington Way, RicNand, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: WNP.2 Address: Hanford Reservafion, Benton County, Washington
    3. (a) Work Performed by: Bechtel construcbon, Inc, Po Box coo, R'chland, wA (b) Repair Organlzatlon P.O. No, Job No, etc.: c20889
    4. Identlflcatlon of System: Servtce Water (SW) System
    5. (a) Applicable Construction Code: As ME section I I I code oass 3, 1971 Edition with winter 1973 Addenda, code case; None (b) ApPllcable Edltlon of ASME Section XI Utlllzed for RePalrs or RePlacementst 1 980 Edition with Winter 1 980 Addenda, Code Case: N406
    5. IdentifIcation of Components Repaired or Replaced and Replacement Components Manufacturer's Name of Name of National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped No Replacement (Yes or No)

    Code Class SW(1)-2 WPPSS SW(1)-2-P1 N/A N/A 19&3 Replacement Yes, Code Qass 3 SW(21)-2 WPPSS SW(21)-2.P1 N/A '/A 1983 Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Installed SW-TEW SW-TEOB, SW-TELIC, SW-TED, SW-FE<B and SWARD. The installation work was performed as follows
    1) Installed thermowells for SW-TERA, SW-TEQB, SW-TELIC and SW-TED
    2) Made required welds
    3) Installed annubar s, piping and valves for SWAB and SW-FEOD
    4) Made required wekfs S) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2~ XASKNOTON PUBUC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) B Tests Conducted: Hydrostatic X Pneumatic Nominal Operating Pressure Other None Test Pressure: 335 Psig Test Temperature:71 F Component Design pressure: 308 psig Temperature: 150o F

    g. Remarks: See attached NPV-1 Code Data Report for the following new valves SW-VN34, Serial No GT 1285 SW-VN35, Serial No GT 1284 SW-V&36, Serial No GT 1281 SW-V+37, Serial No GT 1276 See attached NPP-1 Code Data Report for the following new annubars SW-FEQB, Serial No 13640.01.1 SW-FEND, Serial No 13640.01.3 CERTIFICATE OF COMPLIANCE We certify that the statements made ln this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not apprcable Certificate Authorization No.: Not applicable Expiration Date: Not Appacable Prepared by Signed by G Materials nspection Manager, Materials And Inspection Date Date 7 Z7 F5 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Aritwright Mutual insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components
                                                                                . 'F state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shell be liable ln any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this inspection.
    

    Commissions Inspector's Signature National Board, State, and Endorsements Date

    e ~ <

     )
       'sC.~r'e, '       W,        "~ .  ',  '    ~
                                                      ~
                                               OQf NPY-l MAiiUFACTURERS'ATAREPORT FOR NUCLEAR PUMPS': OR':.:                                                       YALYES
        .'d r) r
                     ~
                                                                   ~,,      a= R~et~ t v the Prov(a(one of the AQIE Code Holes Notwal)t, Ch.
    

    pCkV hl tir... i',~~.a r N17709R SUPPL. 05 i:I

                                                                                            ~ 1$ 4S7 Excels'lot Dtlva                                  Qt)SSO stanu(actutedd b DRhGON VhLVES. INC.
                                                                                                                                ~                             Order No L                                                       (tteae b hddress er Stenulseturer)
                 \
    

    (Nsae snd hddress) s

               ~
                  'ashington      O<<ner Public Pover               Su     1     S   stem          Hanford Jobsite No. 2
    

    ~ ' ' Pl nt Richland, Mashf n ton Serial Numbers GT1266 thru GT1290 (25 Pcs.)

    5. Pump or Valve tdentittcation CQ 1/2 Inch H(PT Instrument Globe Valves. Part Number 500FN057D1.

    (Br!el descrlptlsca et serrtce rsr <<bteh equlpaent <<ss desleoed) ( ~ ) Dra<<ing No. 12997 Prepared by Dra o Valves Inc. (b) National Board No. 3600 F or Pressure C4ss

    6. Design Conditions (preserve) (Tea peruure)
    7. The material, destgn, construction, aod <<orkmsnsbip compiles <<itb hQ}E Code S<<tron ill
        &~
    

    t dttton 1974 h 'dcnda Date 6-30-76 ~ Case No, Xertr tte, Ststrrlsl epee, Ne, ltsnutseturrr ttrmsrtr ~ (a) Castings None VALVE- +PE o. cn- v-w- v- 35

                                                               +-V- dI9 4/- V (b) For sings DVU                   ttT    7d,OS(~              SA1S2       Cr. F316              Aja:( For e Co.
    

    tl) For tnanuoty operate voves ony

                              ~ supplersentsl    sbeets tn tora et ltsts, saetcbes sr drsvtnes <<sy        be used presided       (t} stre   ts s)t ~ a ttrr (r) tnreraert~ j&t gfaspQ f~.
    

    tb+ t~t~ fg en b s et at ()) seb b t t~ tr red nd nursber sr s sets ls re erd d t t p Qj~

                           'L~
    

    e e r r r 0 t

                                                                                                                                                                             ~ ~
    

    I r ~ ~ ~ r ~ r

                                                                                                                                                                           ~
    

    S'

                                   ~
    

    FOffM SLPV-I (bite)c)

                                                                                                                                                       ]$ -$ /029 4
    

    5BQBR p Stovta ftar Stalartat 5$ CC ?tao St s aa(a ts c lance RCCIErta (e) Bolting None (d) Other Pares

                                                                                                   '2 1 Bonnet            HT 8643                      SA>>7                            Roasaahl      4 C      $            rp.
    

    icDt... Union Nut HT 11684 SA479 TY 316 Car enter Techno o Cor

    8. lfydrostatic tes 5400 pair CERTIFICATION OF DESIGN MSH/BOECON/GERI Desi~
                  ~l,e    s an lys s cep       e rc,f; d by nOC requ?r (ll P         l.Era.S<<R (i(Pat (.E S.aaa WA R
                                                                                                                                                              ~ .R g.Ã.
                                                                                                                                                                   . 12542 (1) Signature not required. Lisc name only.
    

    We eetcify thac the scacemencs made in chis reporc arc correct. fra 2 VkACO<a VSSLI:KS. 1)IC. Ify Itc ~ llllrsciuicrl Ce tif'e te of h tho izst on No. N- I 033 expires Ry CERTIFICATE OF SIIOP la'INSPECTION the undersif neda holding a valid eomrnission issued by the National Board of ffoifer and Pr'en sure Vessel in spec toes

                        ~
    

    A for the qtste of prspvanee of ChLIFORNfh foed byDfvf sion of Industrial Safety have inspected the eciuipmeni frv(<ll I ln:his D t has constructed this equipmenc in aeeordanee <<ith the applicable Subsections of hS~IE Code, See!ion lll. Qy signing this eertitieace, neither the faaspeetot nor his employer makes any <<srrancy, expressed or implied, eonecrn-ing the equipment deseaifrc(f in .is == R. ort, Furthermore, neither the Inspector nor his employer siisii bc lia I in =ny manner tor any personal injury or property damn(te or a loss of any kind arising from oc eoaaaieeted E;ith ~:.s:nspec cion. Date I~ f] 19 Commissions Cal I18anvctor) ftI'Catarlat Cia+a(rr Sic(or Fsavlnce and:to.)

                                   /
    

    Pr into(f ln UA.Ar r

          ~
            $ ~    W~
    
                                                                                                                                 /LAN'IO. 2-<878 FORM NPP.1 CERTIFICATE HOLDERS'DATA REPORT FOR FASRICATED
                                                                                                                                                             ~i NUCLEAR PIPING SUBASSEMSLIESe 1          2 As Required by the Provisions of the ASM E Code, Section III, Oivtsiofs 1                                  Pg.           of Standard INNING ev ~    el err cevl vie trawl I F b      ed fwas hi n          ton Publ i c Power                   Su     l      S  stem, Box 968, Ri chl and,MA 99352-0968 Iaaf W Ieeeel
    
    3. I,,f;,Ii;,MNP-2 3000 Geor e Mashin ton Ma , Richland, MA 99352
    4. Identificadon 13640 01 1-4 NA SU-5271 NA }993 Icec Hoopl In'e.l ICale IOaeeeeg mal curl ee,aeJ IV~leal
    5. ASME Codd, Secllon III 1989 3 NR its~ ~elcel IOoaal icoee Ciiel B. Shop hydrostatic test ~,. ambient room temp.

    Annubar flow sensors 316SS with C/S mounting hardware i in subassemblies B. Ceroficate Holders Oata Reports identified and signed by Commissioned Inspectors have been furnished for the following items of this Reporo propert

    9. Remarks Sw-FD-Lnr-I=rC- /

    o.o 4.0. O/.

                                                                                                                                                          ./
    

    CERTIFICATE OF SHOP COMPLIANCE We cerofy that the statements made in this Report are correct and that the fabrication of the described piping conforms to the rules for construction of the ASME Code, Section III. NPT Ceroficate of Authorization No. N-1728 April 29, 1995 o Q p N Di eteri ch Standard Signed (Nrr cervtscoe Houri CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Yessel Inspectors and the State or f d pi ycdby Comerci al Uni on Insurance Co. of have inspected the component described in this Oata Rcport on

                          , and state that to the best of my knowledge and belief, the Certificate Holder has constructed'this component in ac-cordance with the ASME Code, Section III.
    

    By signing this certificate neither the Inspector nor his employer makes any warranty, ekpreSSed or implied, concerning the component described in this Oats Rcport. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fr connected with this inspection. 'f I t$ W auLSr Supplemental informado for of Ilats, sketches. or drawings may be used provided Itl size ie 8IS X 11, i2I infoimadon in items 1 through 4 on this octa is included on each sheet, I3I each sheet is numbered end the number of sheets is recorded at the top of this form. I8/85) This form IE00082) may be obtained from the Order Oeot., ASM8. 348 8. 47th St., New York, N.Y. 10017.

                                                                                                                                                           ~ ~ I
               ~ ~
    

    FORM NPP-1 (back) Ikfr. Serial No. IO. Description ot field fabrication I t. Pneu., hydro., or comb. test prcssure psi at temp. ' iifssertormedl CERTIFICATE OF FIELD FABRICATION COMPLIANCE Wc certify that the statements an this Rcport are correct and that the field fabrication ot the described pimng conforms with the rules for construction ot the ASME CODE, Section III. NPT Certificate of Authorization No. Expires Date Signed

                                                      'Cpt'<~ HOCW I                                                 I +IOhhOMK~I CERTIFICATE OF FIELD FABRICATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board af Boiler and Pressure Vessel Inspectors and the State or Province af                          and employed by of                                 have compared the statements in this Data Rcport      ~th the deus bed piping and state that parts retcrred to as data items                                                       , not  included    in the Certificate of Shop Inspection have been inspected by me on                           and that to the best of my knowledge and belief the NPT Certificate Holder has fabricated this piping in accordance   with the ASME Code, Section III.
    

    By signing this cerificatc neither the Inspector nor his employer makes any warranty, expressed or implied. concerning thc piping de-scribed in this Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any persaruN injury or property damage ar a loss of any kind arising from or connected with this inspection. Date Signed IAIDO CI4 IACNCWI Commissions IN'. aa ~ osoanesaeecI. suce er Ice. awe Mal

    q o87Z o Page 2 of 2 v/~l>~

    1. Uieterich Standard, bbV1 N. 71st "Street, Boulder, CO 80301 Z. washington Public Power System, Box g68, Richland,-'AA 993~2-09bu MHP-2 30UU I eorge washington w'ay, eicnlana,.llA 99352 13640.01.1-.4 N/A SU-6271 N/A 1993 Annubar Flow Sensors, 316SS with C/S mounting hardware (piping subassem-blies)

    Flange, support aisc SA-182 Velocity probe, sensor tubes, tag ring SA-213 Transition SA-312 cieaa, tips bH 'k 79 weld filler 'SF'-5.9 Threaaed roas SA-1 J3 Hex nuts SA-lg0 Flangea pipe,'ela couplet, support plug SA-105 Certificate Holder oar.e *//f9 Autnorizea Inspector I f3

    0 e

    PLAN HO 24874 trASH1HGTOM Pustlc SYSTEMPOX'UPPLY FORM NIS-2 OWNER'S REPOR7 FOR REPAIRS OR REPLACEMENTS As Required by the Prot/Islons of the ASME Code Section XI

    1. Ott/ner: Washington Public Power Supply System (WPPSS) Date: 7/21/93 Address: oooo George Washington Way, Richland, Washington Sheet: > of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nucbar Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Bechtel Construct'on, Inc, Po Box 8OO, Richland, WA (b) Repair Organlzatlon P.O. No, Job Ho, etc.: c2oo89
    4. Identlflcatlon of System: Service Water (SW) System 5, (a) APPllcable Construction COde: ASME Section III Code Class 3, 1971 Edition with Winier 1973 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements:198o Eden with tMnter 198o Addenda, Code Case: NOM
    6. IdentifIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement (y'es or No)

    Code Class SW(2)-2 WPPSS SW(2) -2.P1 N/A N/A 1983 Replacement Yes, Code Class 3 SW(22)-2 WPPSS SW(22)-2-Pl N/A N/A 1983 Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Installed SW-TEQE, SW-TEcF, SW-TEoG, SW-TECH, SW-FEoF and SWEEaH. The lnstshtion work was performed as follows
    1) Installed thermowells for SW-TEQE, SW-TEPF, SW-TE4G and SW-TECH
    2) Made required welds
    3) Installed annubars, piping and valves for SW-FE4F and SW-FETCH
    4) Made required welds
    5) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2~74 lfASNHGTOH PUBLIC POWER SUPPLY SYSTEM FORM Nl~ OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic X Pneumatic Nominal Operating Pressure Other None Test Pressure: 336 Pig Test Temperature: 74.8 F Component Design Pressure: 309 Psig Temperature: 1 soo F

    g. Remarka: Sae attached NPV-1 Code Data Reports for tha following naw valves SW-V+38, Serial No GT 1286 SW-V4I39, Serial No GT 1289 SW-V4I40, Sedal No GT 1356 SW-V4I41, Serial No GT 1348 Sae attached NPP-1 Code Data Report for the foNowing new annubars SW-FE4F, Serial No 13640.01.2 SW-FETCH, Serial No 13640.01.4 CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not appt'cable Certificate Authorlzetlon No.: Not applcabte Expiration Date: No't Appl'cable O

    Prepared by Signed by Materials Inspection Manager, Materials And Inspection Date Date 7 93 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                          'I 1I'.                                          and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section JK By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report.
    

    Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions nspactoA Signature National Board, State, and Endorsements Date l-zs-

    ~ P "" . '

                                            ".:,', ..',FOR11NPV-'l MPuiUFACTUREHP DATA'REPORT FOR itUCLEAR PUMPS OR
                                              "   '.."   '"'~ -"- I-o                   .I
                                                                                                ".' ".r WI'te
                                                                                                          ~~~. '~:.""'~".
    

    P/oereioeeo[eto Arilc Core IIelee

                                                                                                                                                    '                          YhLYESo-
                                                                                                                                                                        "',,':.'+'          ..  '.. '.-",,o' too~-
    

    Rx.-- ~-" ~ J ' ISl57 Exci)slot Dt(tra ~ Homal ko CA. 90()>0 ()tdcr No N17709R SUPPLo g5 klanufactutedd b DfchCOH vhLYES.INC.

                                                                                              ~
    

    iver,r'." '..'-'. I (N vse h hddreea of tlrrtufseturerj

                                                                      /          ./
    

    (Nmo enof hddrsos) P.'tc t c Washington Public Poster Su 1 S stem Hanford Jobsite No. 2 0<<ncr ~ ~ ~

                                                           "                                        ton:,-"
    

    of Plant -~Richland, Washin ""'ocation

                                                   '.'-'- " ~:".=":." ".'erial Numbers GT1266 thru                                                                             -~
    

    J GT1290 (25 Pcs.) ':

               "o Pump or      Yaloo ldcncificacion                                                                                                            I
                                                                       ~  ~
    

    CO I --," 1/2 Inch FNPT Instrument Globe Valves. Part Number 500FN057Dl. (artef descrlptlon ol seretce for vhlch eetulpeaent vas deslgaed) 12997 Ptcpatcd by Dra o Va ves Inc'. (a) Dta<<ing No. (b) National Doatd No. 3600 I 100 F or Pressure Ctoss pest~ Condtttons (Pres sure) p (Tceo pe rot ere) Th

                                                    '    d;,       construction, and <<otkrnsnsbip complics <<itb hSt)E Code Sect ono lll. Class I;dttton              ] 97(J             hddoenf     r)atc      6-30-76                          r Cast: No.
    

    Stork Ne, Ststertst Spec. Ne. ~ Csnutacturer Krraerks {5) Csstlncs NOne y C.kCPAI O. l ~ C) w- Y-w- Y'- (b) Forgrngs Dod vn 762@II SA182 Gr. F316 A)a: For e Co. ti) For menue y opera te vo ves o

                              ~,sfuPPtersentst shoals ln lorra of Qsts, sketches or drsvtnro raoP hs eee4 Proetded (I) ~ lce Io ~ )coo 5 lloo (3) Infens                       tf~~     fmaggg    +
          '                                                                                                                                                                                  j~+Qgr
                                                                                       -".4k ..ooo::.eo: <-':. i%!:Jr- %% ": O'Jo//JAN)N/t)n
      ~ ~
                    ..         I" Sh on thl ~ data report ls Included on each sheet, and (3) each sheet ls neeahered snd nurshsr of sheets le recorded st top of theirs r                 e           e               e                                                                       r                 r
       /c'.-Isrr,'~i                    UN+o%g'r.)'"kr,.,:i-'-                t   e          J
    
           .~    . frs~/~4/~
    

    2 IL"'""-' '"esR g -"lyon.9 r rr 'I I itatertg)t 5SEe, )tn, St snsglsetseer

      ~- c",.': (c j-'Batting'..u None
                                                                                                                                                    ~
                                                                                                                                                      )~ ~  rs ~
    

    S (d) Ocher Parts SA4" 'I 1{c' Bonnet - HT 8643 Rg Es e rp

    ,Disc "- HT 1810-3-1062
                         . Union Nut HT 11684 Stellite SA479 TY 316 No. 6 Cabot Cor . Stel Car enter Techno o i cDv Cor g
    

    rg i P 4 ~ I ~

                                               ~   r
    
    • psig CERTIFI CATION OF DESIGN MSH BOECON GERI 4 ~

    Stress analysas ceport on file ac ()) P f.sgg.hr ~ ((4 g.)f 12542 R . ()) Pr f.s g.gr r R g.R . {I) Signature aoc ccquared. Lisc name oaly. d'ye cercsfy chac chc stacemeacs snade sn this rcport are correcc. 1()~ Signed f)ftssGO)q VALVES, I.'(O. (ttsnfdsca(sgrr) Cercsficacc of barbarizatio No. N )033 expaces CERTIFICATE OF SIIOP ls'fSPECTIO.'c I; che uadecsigned, holding ~ valid commission issued by the Nacional Board of Boiler and Pressure Vessel laspeccocs

              =-d/or      che Sc ce        of Pro nce of                                                                        D(vis(on of Industrial Safety have inspected the cy'.pm:nc girdles'sir               .'n  as:s D ca bas constructed this equipmenc in accordance aich the applieabge Subsections of hS~IE Code, Section III.
    

    By sagning chis ceccaticate, aeicher the lntpectoc no: his esnployer makes any warranty, expressed or implied, concern-ing chc equipment described In this =:-" q. orc, Furthermore. neither the Inspeccoc nor his employer snail be lia-Ie:n mannec for any personal injury oc property damage or a loss of any kiad arising from or coggnecce~ sich ass:.5: snakc(on.

                                                                                                                                                                                ~
    

    Dace / 'c) g] Ig) gP,O Commsssions Cal-

                                   /   (tnptgg) cans)                                                                (Ssclonnt Boss(Is    SSPS ~ g Pgmlnee nfsft:ro )
        ;. Prtnaed In VA~                                                                                             5
                                                                                                                                                           ...,      FOR(gf/4(
    

    R '--'-'= ..'--'-": - "'==-: ':=-*:.:-: -=: ~ --:- '--. t.-...-a;.~~~;";r Sc rta sto .-: gatofrtat gtfoe tco, Sto rrfara et urot a ~hol'g h .vooh lhohh o' e '&msrsa PWXa4&h' g+ r C ~ h 3 os t o~ ~ (4) Other iaarta ~ . ~

                   ~
                     ".'o
                                                                        ~                       .
                                         . Bonnet,                 HT 8643313 i
                                       ~
    

    fad ~ Disc '". --3-HT 1810-3-1062 Stel1ite No. 6 Cabot or . Ste e v co w ~~ Union Nut HT .11684-=.'.-.-:=2= SA479 TY 316 Car enter Techno o Cor

                                                                                                              ~     ~
      ~~.r:li. ': ff:..                                                               Y Y        f~  ~                ~  OR   '                                                      Jl L~-.-'==':-:
                                                                                                                                                                                                                   'r.
    

    o~

                                                ~ o,  ~   hot, ~ , ~        ~              ~ '.
                                                                                                                                                                               ~ 'I w    ~ ~ - Wua.o h, o.oryh~
    

    o Q slate~i o vho 3 ~ ~

     .tCY..-.'-'-
      ~     >>~            r: eh Hydroscatic tes                                                                                                                       ~o
                                                                               ':.",-,r-;.:,3       r   CEKTlFICATIOa( OF OESIGa(
    

    h "QSH/BOECCH CERX '- f ~ ~ I ~. (l) Signature

                                                         ,.  ,-,f;~bDavid J.
    

    noc tequarcd. Lisc name only. Hur h P of.a r.ao Prof. Eng. State o ffA '"R R.N . 125 Reg. No. We cettafy chac lhe scacemcncs made in chas report >>re correcc. 3 dao < fl 3 o oi h .....,.'-o N f033: fat onfrf oct uroy) hf 3 !allo o CERTIFICATE OF QIOP laMSP ECTIOlfj l, che undcrsigncdr holding a v~lid commission issued by -c Nacimaa. nacrd o. Doilcr and trssure Vessel lnsPCCtotS Dl".!sl n Of industrial Safety e'ate of Province of ChLlFOR!mfa rand employed by of ChLlFORNIh have fnspccccd the equipmenc descrabed ln chis Data

                                                                                     >>33 this equiPment ia a cord acc '<<ith the afoPlicabae Subsections of hSSIE Codcr Seccion ill hao eonoarfrctcd fty slgninc this ccftlllcalca neither lhc ntp                               5           '                 ycr ~cs <<oy coact Nortf3 csprcssco or implied concern lag ahe equapanenc descrabed in chas Data Report. Futthermote neither the inspector nor has employer shall be liable in any raanner for any pctsonal injury ot pcoperty damage or a loss o'l any kind atislng ftom or connected with this inspcccionh Date                                       Jf      i9 QZ p    ~    j pocaor)
                                                                                                                                   ~
    

    Cororfaa <Raons Cal. c {'t~ llOnot Doordo Saotoo Provtneo ond ttoo)

    FORM NPP 1 CERTIFICATE HOLDERS'ATA REPORT FOR FABRICATED NUCLEAR PIPING SUBASSEMBLIESe q/AS 1 2 As Required by the Provisions of the ASME Code, Section III, Dlyision 1 PQ. of Fab ed nd ified by Oi eteri ch Standar d, 560 1 N. 71 st Street . Boiliader, CO 8030 1 t INcrrrc NN ccNNcc et Nrr ccrcrhcccc NNetrl Fab 'd f Was hin ton Publ ic Power Su 1 S stem, Box 968, Ri chl and, WA 99352-0968 INcrrrc cre NNrcet WNP 2 3000 Geor e Washin ton Wa, Ri chl and, WA 99352 INcrrrc tru NNrruc NA SU-5271 NA }993 ICltNI (Drcrrrre re.l INcrt. Sa rN.I Ircu crcrcl 1989 3 NR I ttccccrr INcecrccN recut (ONN IONN Cccr I 470 ambient room temp. 'F iif performedl Annubar flow sensors 316SS with C/S mounting hardware i in subassemblies B. Certtficate Holders Oata Reports identified and signed by Commissioned Inspectors have been turntsned for the tollowing items of this Report: propertA NA

    9. Remarks W-Ff Io'4 0. O/.

    FE'-

                                                                                                                       -gP'-
    

    I'a.ai. CERTIFICATE OF SHOP COMPLIANCE We certily that the statements made in this Report are correct and that the fabrication of the described piping conforms to the rules tor constructton of the ASME Code, Section III. NPT Ceniticate of Authorization No. April 29, 1995 Oate , , Oieterich Standard lrer corbtNNc tcrrccerl S)gned c tcccrrr rrrrcrclrr c

                          /
    

    CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or province of and employed by C mmerCi al Uni On InSuranCe CO. of have Inspected the component described in this Data Report on

                            , and  state  that  to     the   best  of  my   knowledge        and    belief,     the Certificate Holder has constructed this component in ac-cordance with the ASME Code, Section III.
    

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Oata Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising fr connected with this inspection. 9 I1$ INrecnea eeccNN Pug W Calf ss4 Supplemental lnformado t tor of Ibts, sketches, or drawings may ba used provided I1) size ls 8$ X 11, I2) Informadon in items 1 through 4 on this oata rt is incluoecs on each sheet, I3) each sheet is numbered and the number ot sheets is recorded at the top ot this form. I6/86) This form IE00062) may be obtained from the Order Oept., ASMS, 346 S. 47th St., New York, N.Y. 10017.

    FORM NPP-1 (bade) Mfr. Serial No,

    10. Description ot field fabrication
    11. Pneu., hydro., or comb. test pressure psi at temp 'P iit performed)

    CERTIFICATE OF FIELD FABRICATION COMPLIANCE We certify that the statements on this Report are correct and that the field fabrication of the described piping conforms with the rules for construction of the ASME CODE, Section III. NPT Cerhficate of Authorization No. Expires Date Name Signed

                                                                                                                    < l4arnonaawe  >
    

    CERTIFICATE OF FIELD FABRICATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board ot Boiler and Pressure Vessel Inspectors and the State or Province of and employed bv of have compared the statements in this Data Report with the described piping and state that parts referred to as data items , not included in the Certificate of Shop Inspection have been inspected by me on and that to the best of my knowledge and belief the NPT Certificate Holder has fabricated this piping in accordance with the ASME Code, Section III. By signing this cerificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the piping de. scribed in this Data Report. Funhermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection. Date Signed Commissions lANhOrkN IACNCNI iwn. w.~. <<esar~eeen. Suce cv Bee. ass Nal

    Page 2 of 2 ~jm/U

    l. Uieterich Standard, b601-N. 71st Street, Boulder, CO 80301
    2. washington Public Power System, Box 968, Richland, 'AA 993~2-0965 WNP-8 3UOU t eorge w'ashington may, wicnlana, llA 99352 13640.01. 1-. 4 N/A SU-5271 N/A 1993 Annubar Flow Sensors, 316SS with C/S neunting hardware (piping subassem-blies)

    Flange, support aisc SA-182 Velocity prooe, sensor tunes, tag ring SA-213 Transition SA-312 rreda ti ps SA -i 79 weld filler 'bF~-S.9 Threaded roas SA-i93 Hex nuts SA-lg4 F)angea pipe,'eia couplet, support plug SA-10b Certificate Holaer Oeee ~///9 Authori zea Inspector

    PLAN NO 2~7d lrAsttutctoM pusuc poxBR SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 7/21/93 Address: 3000 George Washington Way, Rchland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County. Washington
    3. (a) Work Performed by: Bechtei Consrrction, Inc, PO Box 800, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: C20089
    4. Identlflcatlon of System: Service Water (SW) System
    5. (a) APPllcable ConstructlOn COde: ASME Section III Coda Class 3, 1971 Edition with Winter 1973 Addenda, Code Case: None P) ApPllcable Edltlon of ASME Section XI Utlllzed for RePalrs or RePIacementst1980 Edition w'rth winter 1980 Addenda, Code Casa: N4M
    8. Identlfication of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped No Replacement (y'es or No)

    Code Class SW(70) ~ 1-HPCS WPPSS SW(70)-1-HPCS-P 1 N/A N/A 1983 Replacement Yes, Code Class 3 SW(71)-1-HPCS WPPSS SW(71)-1-HPCS-P1 N/A N/A 1983 Replacement Yes, Code Class 3

    7. Descrlptlon of Work: Installed SW-TECH and SW-TEAK. The installation work was performed as follows
    1) Installed thannowells for SW-TE4J and SW-TEAK
    2) Made required welds
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during tha pressure test

    PLAN NO 2~lS XASHlMGTOH PUBUC POKER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Plack) e Tests Conducted: Hydrostatic ~X Pneumatic Nominal Operating Pressure Other None Test Pressure: 1 sa peg Teat Temperature: 71o F Component Design Pressure:15o Pslg Temperature: tsP F

    9. Remarks: None CERTIFICATE OF COMPVANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not apptcable Certificate Authorization No.: Not apprcable Expiration Date: Not Applicable O

    Prepared by Signed by Materials And Inspection Manager, Materials And Inspection Date 7 2-M. Date - Z7-g3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors end the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components end state to the best of my knowledge and belief, the Owner has performed examinations and taken ASME Code, Section ¹ corrective measures described In this Owner's Report In accordance with the requirements of the By signing this certificat neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Reporf. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or e loss of any kind arising from or connected with this Inspection. Commissions 55cr AJ Inspectors SignatUre National Board, State, and Endor sements Date 7~a gS

    PLAN NO 2~77 lrASHlxcTOH PUIUC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPOR7 FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the A$'ME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 7/30/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1 2, Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Rant (WNP) Unit: WNP.2 Address: Hanford Reservation, Benton County, Washington
    3. (e) 'Work Performed by: Washington Public Power Supply System (WPPS S), 3ooo George Washington Way, Richland, WA (b) Repair Orrpanlzatlon P.O. No, Job No, etc.: Washington Pub4c Power Supply system (WppsS)
    4. IdentlfIcation of System: SarvfceWatar (SW) System
    5. (e) Applicable Construction Code: As ME sacbon ill Coda Cess 2, 1971 Edition wiA Winter 1973 Addenda, Gode casa: None (b) AppllCable EdltlOn Of ASME SeCtlOn XI UtlllZed fOr Repalra Or RepleCementS: 196O Edition with Winter 1960 Addenda, Codo Case: N4M
    8. IdentlfIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired,'eplaced ASME Code Component Manufacturer Serial No Board "

    I.D. Built or Stamped No Replacement (Yes or No) Code Class SW.V-931 B 17616 N/A N/A 1976 Yes, Code Class 2

    7. Descrlptlon of Work: Made body to bonnet seal weld%or valve sw-v.931B. Tha work was performed as follows
    1) Cut valve body to bonnet seal weld
    2) Removed valvo internals for troubleshooting
    3) Prepped cut/ground areas on the valve body and the bonnet
    4) Performed MT examination on the valve body and bonnet prepped areas. MT axaminaion results acceptable
    5) Reinstalied valve internals and the bonnet
    6) Made valve body to bonnet seal wokl
    7) Performed MT examination on tha final seal weld. MT examination results acceptable

    PLAN NO 2~77 trASHINGTON PUBUC POXER SUPPLY SYSTEM FORM HIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Bacg 8 Tests Conducted; Hydrostatic ~ Test Pressure: Pslg Pneumatic Nominal Operating Pressure Test Temperature: F

                                                                                                      ~     Other     X  None Component Design Pressur e:        Pslg           Temperature: o F
    
    9. Remarks: None CERTIFICATE OF COMPLIANCE We cert/fy that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not appl'cable Certificate Authorization No.: Not apprcable EXplratlOn Date: Not Apptloabte Prepared by Signed by Mater'rson Manager, Materials And Inspection Date Date <-R) - 93 CERTIFICATE OF INSERVICE INSPEC77ON
       /, the undersigned,    holding a valid commission Issued by the Natlona/ Board of Boiler and Pressure Vessel Inspectors and the State      of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components described In this Owner's Report during the period               t'Z~-   1~ to           7'7         l~      and state to the best of my knowledge and belief, the         Owner has performed    examinations      and  taken conective measures described in this Owner's Report In accordance with the requ/rements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concemlng the examinations and corrective measures described In this Owner's Report.
    

    Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arlsln g from or connected with this InspectIon Commissions 554 4c/ In or's Signature National Board, State, and Endorsements E- Z.t 3'ate

    PLAN NO 2<878 trASIIIHGTOII PUBLIC PoirfR SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 8I2393 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Hanford Reservation, Benton County, Washington 'ddress:
    3. (a) Work Performed by: Bechtel Construction, Inc, PO Box 800, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: c20089
    4. Identlflcatlon of System: Control Rod Drive (CRD) System "
    5. (a) Applicable Construction Code: ASME Section III Code Class 2, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) Applicable Edition of ASME Section XI Utlllzed for Repairs or Replacements:1980 Edition with Winter 1980 Addenda, Code Case: N~
    6. Identlflcatlon of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement (Yes or Ho)

    Code Class CRD-Saamllnst GE, l8CE CRD-Scram/Inst NIA 1982 Replacement Yes, Code Class 2

    7. Descrlptlon of Work: Installed flush connections for Scram Discharge Volume (SDV). The installation work was performed as follows
    1) Installed new fianged pipets on the existing piping
    2) Made required welds
    3) Performed MT or PT examination on the final welds. MT or PT examination results acceptable
    4) Installed new blind flange and the bolting material
    5) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO2<878

                                                          )rASH)HGTON PUBUC Po)rER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic X Pneumatic                        Nominal Operating Pressure                 Other       None Test Pressure: 1585 to 18oo Pslg                       Tact Temperature:81 to86.5 F Component Design Pressure:            125o Psig        Temperature: 28o F R Remarks:    None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applcable Certlflcate Authorlzatlon No.: Not applicable Explratlon Date: Not Applicable Prepared by Materials     d Inspection D )
    

    Signed by . Manager, Materials And Inspection 8-z- vz Date Date CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commlsslon Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Facto)y Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                                              ~S.        8 .           and state to the best of my knowledge and belief, the Owner has performed examlnatlons and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By slgnlng this certificate neIther the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examlnatlons and corrective measures described In this Owner's Repod.
    

    Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlslng from or connected with this Inspection Commlsslons Ins or's Signature National Board, State, and Endorsements Date

    PLAN NO 2~86 XASIIDIGTOII PUBtIC POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI H

    1. OWnert Washington Public Powor Supply System (WPPSS) Date: 7/22/83 Address: Sooo George washington way, Richland, washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuckwir Power Rant (WNP) Unit: wNr -2 Address: Hanford Reservation, Benton County, Washington
    3. (a) WOrk PerfOrmed by: Bochtol Consruction, Inc, PO Box 6OO. Richland, WA (b) Repair Orrlanlzatlon P.O. No, Job No, etc.: cams
    4. Identlflcatlon of System: Process Instrument (Pl) System
    5. (a) APPIICable COnStruCtlOn COde: AS ME Section III Coda Class 1, 1 974 Edition with Winter 1975 Addenda, ~e Case: None (b) Applicable Edltlon of ASME Section XI UtIILzed for Repairs or Replacements: 1 Mo Edition wnh Winter 188o Addenda, Coda Casa: N408
    5. IdentifIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Repleced or Stamped No Replacement Pes or Ho)

    Code Class Pl(1) <S-X+1 A JCI Pl(1) M-X+1A N/A 1982 Replacement Yas, Code Class 1

    7. Description of Work: Fabricated and installed modified conno'ction with valve pl-V-eot. Tha fabrication and installation work was performed as follows
    1) Fabricated pipe nipple 4
    2) Parformod PT examination on tha final machined surfaces of the pipe nipple. PT examination results acceptable
    3) Beveled the socket and of the new va! ve for butt welding
    4) Performed PT examination on the beveled end of the valve. PT examinabon results acceptable
    5) Cut and removed tha exisbng connection
    6) Installed pipe nipple and valve and made required welds
    7) Performed PT examination on the final walds. PT examination results acceptable
    8) Performed RT examination on the final circumferential butt wokf. RT examination rosults acceptable

    WASHIIICTCII PUBIJC PONER PLAN NO 2~ SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Test Pressure: Pslg Pneumatic ~ Nominal Operating Pressure Test Temperature: oF Other X None Component Design Pressure: Pslg Temperature: o F

    9. Remarks: See attached NPV-1 Code Data Report for the wr valve PI-V4ot, Serial No PB 1 1 62 CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this reptacement conforms to the rules of the ASME Code, Section Xi Type Code Symbol Stamp: Not appt'cable Certificate Authorization No.: Not appl'cable Expiration Date: Not Applicable 0

    Prepared by 4 Signed by Materials And In Manager, Materials And Inspectiort Date 2- 7- 27-F3 CERTIFICATE OF INSERVICE INSPEC77ON I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components described In this Owner's Report during the period /- /2= 9Z to 7-3'e- W3'nd state to the best of my knowledge and belief, the Owner has performed examinations and taken conectlve measures described in this Owner's Report In accordance with the reriulrements of the ASME Code, Section N. By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions NE~~M ~B ~ InspeotoA Signature National Board, State, and Endorsements Date

    pc.~ ]Co, 2-<886 FOIIM NPV-I N CEIITIFICATE HOLDEIIS'ATA REPORT FOR IIUCLEAll PUMPS Oll VALVES'As Required by the Provisions of the ASME Code. Soedon III, Dlv. 1, c I I r e d II D ra 9 o n Va 1 ve s, Xn c ., 1 3 4 S 7 Ex c e 1 s o Dir r ., r 8 o wa 1 k, C A 9 06 5 0 7 eo/T3 (Name and Address of N Certificate Holder) Manufactured for sh . Public Ptfrr . Su . S stettt P ~ 0 . Box 968 Richland WA 99 3S 2 INome ond Addless ol Ptffclsosef of Owned 1

    3. Location of Installation INome ond Addfessi
    4. Pump or Valve Valve (incff) tnclg (a) Model No., (b) N Cerllflcuaufe Holder's (c) Canatlian Series No. Serial Aegislration (d) Drawing (I) Nal'I. (g) Year or Type No. No. No. (c) Class Od. No. Built (I)

    (2) (3) PB1162 (4) (S) (6) Pl P7- tf'- 0/ Z /~ Ala. l fI 42. (8) (g) (lg) Globe Valve 3 s ~ IOfiel descfiplion of service tod which eqvipment wos desienodi

    6. Design Conditions 3600 p~ 100 F or Valve Pressure Class IPfessuf ~ I IZempefoftfeet psi at IIXPF.
    0. I'rossuro Aelaining Pieces Mark No. Material Spec. No. Manufacturer Aemafks fb) Forgings nn Yk (1) For manually operated valves only Supplemental sheets in form of lists. sketches or drawings may be used provided (1) sire Is 8.)f2 st 11 . (2) information in items 1. 2 and 5 on this Data Aeporl is Incksded on each sheol, and (3) each sheet Is numbered and number of sheets is recorded al top of tlfis form.

    I Inn>I 5 Thts lnem IFFSCl111 mrvte ttse eshdtetesnvl revem Pter rsvp ~ aasC Aa a sees eo of~ v~ ae v eesrsei

    FOfthl NPV l (pack) Ma'rk Na. Mater)at Spec. No. Manufacturer II omar)ts (c) Bolli (d) Other Parts 43 ASME SA564 GR 630 Car enter Steel Disc

    p. ttydroriatk test ~Q~ pal. ohk oiffsrant tat test prerrure 3600 prt.
    CERTIFICATE OF COMPLIANCE We certify that tha statements made in this report aro correct and that this pump, or valve, contorms to the rules ot 1974 construction ot tha ASME Code tor Nuclear Power Plant Components. Section ill, Div, l..'Edition Addenda f0 stet
                                                . Coda Casa No.                                                June     ll    1992 Signed                                                                         by                     fI tH Ccrtlncal ~ Holdert Our ASME Ccrtiticata ot Authorfration No.                                   to use the         N           ~ ymbol   exOOoo    5-6-93 (ON    )
    

    CEATIFICATION OF DESIGN Dcsipn information on rile at Washin ton Public Power Su 1 S stem (See Line 2) ~ Stress analysis report (Class 1 only) on lite at Washin ton Public power Su 1 S stem specifications certified by (I) J m s F. Ha en Jr. 'e PE State Rcg. No. 13579 Stress analysis certified by (I) . r und n PE Slate CA Rcg No M20589 (I) Signature not required. Lisl nemo only. r ~ rcL / DATE CEIITIFICATE OF SHOP INSPECTfON l, the underslpnod, holding a valid commission issued by the National Doard ol Baiter arwf Pressure Vessel tnsL3octors CALIFORNIA and the State or Province of employed by H ~ S ~ BN IN of HARTFORD CT

                                             ~,             have inspected tho pump, or valve, described in lhis Data Report on t9 c.$ 9 and stato that to the best of my knowledge and botiat. tho N Cortilicate Holder has con.
    

    struclad this pump, or valve, in accordanco with tha ASME Code, Section ill. Dy sipninp this certificate, ncithcr tha Inspector nor his cmployor makes any warranty. cxprasscd or implied, concarni the equipment described fn this Data Rcport. Furthermore, neither thc Inspector nor his cmploycr shalt be liable i mannor for any personal Injury or property damage or a loss ot any kind arising from or connected wilh this inspocti 4 / .c(P CammlIOoos +O-l~~nd. gnstiocror I tweet State, rio . a~t m)

    lrAsHIHGTOM putrUc potrza PLAN NO 2~ SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI l

    1. OWner: Washington Public Power Supply System (WPPSS) Date: 7/22/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:Washington Pubgc Power Supply System (WPPSS)
    4. Iden tlflcatlon of System: Main Steam (MS) System
    5. (a) Applicable Construction Code: As ME sacked III code class 1, 1971 Edition with no Addenda, code case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacementst1980 Edition with Wetter 1S80 Addenda, Code Case: N408
    5. Identlflcatlon of Components Repaired or Replaced and Replacement Components Manufacturer's Name of Name of National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced or Stamped No Replacement (Yes or Ho)

    Code Class S pare Valve Crosby N/A 1981 Replacement Yes, Code Class 1

    7. Descrlptlon of Work: Replaced disc insert and nozzle for spare main steam relief valve, Serial No N6379040<t 20. The replacement work was performed as follows
    1) Removed existing disc insert and nozzle from the valve
    2) Installed new disc insert and nozzle in the valve

    PLAN htO 2~89 XASItlNGTOII Pusuc POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS p'acket Pneumatic Nominal Operating Pressure Other X None 8 Tests Conducted: Hydrostatic Test Pressure: Pslg Test Temperature: o F Component Design Pressure: Psig Temperature. o F

    9. Remarks: Pressure test to con5rm pressuro boundary Integrity on the hanged joints will be porformod whon the spare valvo is Installed in the systom under a separate ASME Secbon XI plan CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct end this replacement confomts to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicablo Certificate Authorization No.: Not applicable Expiration Date: Not Appl Icabio O Cl Prepared by Signed by Materials And In Manager, Materials And Inspection Date Date 7- 27-g3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors end the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components
                                                                               //.//.
    

    state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M. By signing this certilicate neither the Inspector nor his employer makes any wananty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions 5 Cc/ JV A ~ spectoA Signature National Board, State, and Endorsemonts Date

    PLAN NO 2~90 XASKNGTOH PUBUC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. OWller: Washington Public Power Supply System (WPPSS) Date.'7I2863 Address: 3000 George Washington Way, Richland, Washington Sheett1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudoar Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (e) WOrk PerfOrmed by: Wasliington Pubric Power Supply System (WPPSS), 3000 George Washington Way. Richland, WA (b) Repair Organlzetlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. Identfflcatlon of System: Main Steam (MS) System S. (a) Applicable Construction Code: ASME Section III Code Class 1, 1 671 Edition with no Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements: 1 ceo Editicn wight Winter 1 geo Addenda, Code Case: N~
    6. Identfflcatlon of Components Repaired or Replaced and Replacement Components Heme of Heme of Manufacturer's Hatlonal Other Veer Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped No Replacement (Yes or No)

    V Code Class S pare Valve Crosby N63780%04057 1981 Replacement Yes, Coda Class 1

    7. Descrlptlon of Work: Replaced disc insert and nozzfe for spare main steam relief valve, Serial No N637go40O057. llama replacement work was performed as follows
    1) Removed existing disc insert and nozzle from the valve
    2) Installed new disc insert and nozzle In the valve

    PLAN NO 2~ WAstuHGToN pUBUc powER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) S Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other ~X None Test Pressure: Psig Test Temperature: o F Component Design Pressure: Psrg Temperature: 4 F

    9. Remarks: Pressure test to confirm pressure boundary Integrity on the tlanged ioints will be performed when the spare vatve is installed in the system under a separate ASME Secbon XI plan CERTIFICATE OF COMPVANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not applicable Expiration Date: Not Applicable Prepared by Signed by Material And Inspecbon Manager, Materials And Inspection Date '} Date 7- <7-P3 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken conectlve measures described In this Owner's Report In accordance with the rerlulrements of the ASME Code, Section M.

    By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal lnJury or property damage or a loss of any kind arising from or connected withthis Inspection. Z4'ommissions nspectors Signature 55 National Board, State, and Endorsements Date 7

    PLAN NO 2~91 XASHlNGTOH PUBUC PolfER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS AN Required by the Provlslone of the ASME Code Section Xl

    1. Ottrnel Washington Public Power Supply System (WPPSS) Date: 7tm93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudoar Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Santon County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon of System: Main steam (MS) system
    6. (a) Applicable Construction Code: ASME Section III Coda Cass 1, 1971 Edition with no Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacements:1980 aMon with vrinter 1980 Addenda, Code Case: N408
    6. Identlflcatlon of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board "I.D. Built Replaced or Stamped No Replacement P'es or No)

    Code Class S pare Valve Crosby N63790404122 1981 Replacement Yas, Codo Class 1

    7. Descrlptlon of Work: Replaced disc insert and nozzie for spare main steam relief valve, serial No N637904041 22. Iha replacement work was performed as follows
    1) Removed existing disc insert and nozzle from tha valve
    2) Installed new disc Insert and nozzle in tha valve
    3) Installed two (2) new suds for the valve inlet nozzle

    PLAN NO 2~91 XASKNGTON FUBUC PolfER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X None Test Pressure: peg , Test Temperature: F Component Design Pressure: Pslg Temperature: F valve Is installed

    9. Remarks: Pressure test to confirm pressure boundary integrity on the flanged joints wIII be performed when the spare in the system under a separate ASME Sccbon XI plan CERTIFICATE OF COMPVANCE LVe certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not appr~

    Certificate Authorization No.: Not appl'cable Expiration Date: Not Appt'+able a Prepared by Signed by Materials And In Manager, Materels And Inspecbon Date Date 7-Z -23 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                             / S-                         ~7P examinations       and  taken and state to the best of my knowledge and belief, the Owner             has performed conectlve measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section Xi.
    

    By signing this certifIcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal Injury or property damage or a loss of any kind arlslng from or connected with this Inspection. Commissions 554~ /VE ~ InspectoA Signature National Board, State, and Endorsements Date

    PLAN NO 2<Bg3 XASHINGTON PUBLIC PoirER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS Aa Required By The Provisions Of The ASME Code Section XI

    1. OWner: Washington Public Power Suppty System (WPPSS) Date:@18/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudoar Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed Byt Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organization P.O. No, Job No, etc.:Washington Public Power Suppty System (WPPSS)
    4. Identification Of System: Main Steam (MS) Systom
    5. (a) Applicable Construction Code: ASME Section III Code Class 1, 1971 Edition with no Addenda, Code Case: None (b) AppllCable EdltlOn Of ASME SeCtlOn XI UtIIIZed FOr Repalra Or ReplaCementS:1980 Ed@'on with Winter 1980 Addenda, Code Case: N~

    ti. Identification Of Components Repaired Or Replaced And Replacement Components Name Of Name Of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced Or Stamped No Replacement (Yes Or No) Code Class MS.RVPD Crosby N6379040%1 26 N/A 1981 Replacement Yes, Code Class 1

    7. Description Of Work Performed: Replaced disc insert and nozzle for main steam relief vahre MS-RVQD, Serial No N63790~

    0126. nio replacement work was performed as follows

    1) Removed existing disc insert and nozzle from the valve
    2) Installed now disc insert and nozzle in the valve
    3) Roinstalted the valvo
    4) Installed two (2) new nuts for tho valve inlet nozzle
    6) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2<893 XASHIHGTOH PU9UC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure X Other 'one TeSt PreSSufe: 1005/6.79 Psig Test Temperature: 538/81.2 F COmpOnent DeSlgn PreSSure: 1250/500 Pslg Temperature: 575/47O F

    9. Remarks: -
    1) Nominal operating pressure test on relief valve Inlet fianged Joint test pressure of 1005 Psfg and test temperature of 538 F, 2) Pneumatic test on relief valve outlet joint, body to bonnet joint, naze ring and adjusbng ring set screw joints -test pressure of 6.79 Psig and test temperature of 81.2 F, 3) Component design pressure and temperature-1250 Psig at575o F for relief valve inlet piping and 500 Psig at 470 F for relief valve outlet piping, 4) Relief valve set pressure and rated temperature -1195 Psig at 575 F CERTIFICATE OF COMPLIANCE We certify that the statements made ln this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not appt'cable Certificate Of Authorization No,: Not applicable EXplratlOn Date: Not Applicable c5 Prepared By Signed By Material And n Manager, Materials And Inspection Date Date 8-pb'-

    r CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure

                                                                               ~V Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report.
    

    Furthermore, neither the Inspector nor his employer shall be liable ln any manner for any personal Injury or property damage or a loss of any kind arising from or connected with this Inspection Commissions 5M AJ /YAM Ins s Signature National Board, State, and Endorsements Date

    PLAN NO 2<897 xASHIHcTON puBUC poirER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI 't. Ottrnef: Washington Public Power Supply System (WPPSS) Date: elf el93 Address: 3000 George Washington Way, Richland, Washington Sheet: > of1

    2. Plarlt: Washington Public Power Supply System (WPPSS) Nucfaar Power Rant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed By: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:WashingtonPublic Power Supply System (WPPSS)
    4. Identlflcatlon Of System: Main Steam (MS) System
    5. (a) Applicable Construction Code: AsME section III coda chss 1, 1971 Edition with winter 1973 Addenda, code case: Nona (b) Applicable Edltlon Of ASME Section XI Utlllzed For Repairs Or Replacements: 19eo Edition with Winter 19eo Addenda, Code Case: N~
    5. Identiflcatlon Of Components Repaired Or Replaced And Replacement Components Name Of Name Of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced Or Stamped No Replacement (Yes Or Ho)

    Code Class B22-G001C WPPSS B22~1 C.P1 N/A N/A 1983 Replacement Yas, Code Class 1

    7. Description Of Work Performed: Replaced existing relief valve MS-ROC. The replacement work was performed as follows
    1) Removed existing relief valve MS.ROC, Serial No N63790~~51 with set pressure of 1185 Psig at rated temperature of 575 F
    2) Installed replacement relief valve with Serial No N63790404052 with set pressure of 1185 Psig at rated temperature of 575o F
    3) Perlormed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test NOTES-
    1) ASME Section III Coda Class 1, 1971 Edition with Winter 1973 Addenda for the piping system
    2) ASME Section III Code Class 1, 1971 Edition with no Addenda for the relief valve

    PLAN NO 2<897 XASHrNGTON Pusilc PortER SUPPLY SYSTEM 4 FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure X Other None Test Pressure: 1005(6.65 Psig Test Temperature: 538/88.8o F Component Design Pressure: 1 250l500 Psig Temperature: 575I470o F

    9. Remarks: 1) See attached NV.t Code Data Report for replacement relief valve Serial No N63780404052, 2) Nominal operating pressure test on relief valve inlet flanged joint - test pressure of 1005 Psig and test temperature of 538 F, 3) Pneumatic test on relief valve outlet joint, body to bonnet Joint, nozzle ring and adjusting ring set screw joints - test pressure of 6.65 pslg and test temperature of 88.8 F, 4)

    Component design pressure and temperature - 1250 Psig at 575 F for relief valve inlet piping and 500 Psig at 470 F for relief valve ouflet piping, 5) Relief valve set pressure and rated temperature - 1185 Psig at 575o F CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section N Type Code Symbol Stamp: Not applicable Certificate 01 AuthorIzatlon No.: Not applicable Expiration Date: Not Applicable Signed By Materials And Inspection Manager, Materials And Inspection Date Date 8'-rs'- pz CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the corn onents p and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report ln accordance with the requirements of the ASME Code, Section N By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions s Signature National Board, State, and Endorsements Date ~/

                          ~   I    ~ ~
                                ~ 0~
                      ~ ~
                      ~ ~
                      ~ I
           ~ 'I I I   ~
                      ~ ~
    

    1 ~

           ~ ~    ~ ~
                      ~ ~
    

    ~ ~

                ~ ~,
    

    1 ~ ~ 4 A a

    PLAN NO 2<898 trASHINGTOH PUBUC PONER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provlslons Of The ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: 8/1 8/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed By: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon Of System: Main Steam (MS) System
    5. (a) Applicable Construction Code: ASME Section III Coda Cass 1, 1971 Edition with Winter 1973 Addenda, Code Case: None (b) APPllcable Edltlon Of ASME Section XI Utlllzed For RePalrs Or RePlacements: 1980 Edition with Winter 1980 Addenda, Coda Casa: N408
    5. Identlflcatlon Of Components Repaired Or Replaced And Replacement Components Name Of Name Of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced Or Stamped No Replacement Pes Or No)

    Code Class B22.G001A WPPSS B22.G001 A.P1 Replacement Yas, Code Class 1

    7. Descrlptlon Of Work Performed: Replaced existing relief valve MS.RV~. The replacement work was performed as follows
    1) Removed existing relief valve MS.RYE, Serial No N63790~55 with set pressure of 1195 Psig at rated temperature of 575o F
    2) Installed replacement relief valve with Serial No N637$ HQ~7 with sat pressure of 1195 Psig at rated temperature of 575 F
    3) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test NOTES-
    1) ASME Section III Code Class 1, 1971 Edition with Winter 1973 Addenda for the piping system
    2) ASME Section III Coda Class 1, 1971 Edition with no Addenda for the relief valve

    PLAN NO 2<898 tfASHnrGTOM PUBLlc PONER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure X Other None Test Pressure: 1000/6.78 Psig Test Temperature: 538/86.4 F COmpOnent DeSlgn PreSSure: 1250/500 Pslg Temperature: 575/470o F

    9. Remarks: 1) see attached Nv.t code Data Report for replacement relief valve serial No N63790404057, 2) Nominal operating pressure test on relief valvo inlet ftanged joint - test pressure of 1000 Psig and tost temperature of 538 F, 3) Pneumatic test on relief valve outlet joint, body to bonnet joint, nozzle ring and adjusting ring set screw joints - test pressure of 6.78 Psig and test temperature of 86.4o F, 4)

    Component design pressuro and temperature -1250 Psig at 575o F for relief valve Inlet piping and 500 Psig at 470 F for relief valve ou5et piping, 5) Relief valve set pressure and rated temperature - 1195 Psig at 575o F CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Of A'uthorlzatlon No.: Not applicable EXplratlOn Date: Not Applicable Prepared By 4 Signed By ~ L+-r Materials And In'spection Manager, Materials And Inspection Date Date B. is.=PS CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section N By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described ln this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions 534 In or's Signature National Board, State, and Endorsements Date

    f'. ~l ahcA S Ci 4~ 4 j.j e VA LV E 5 04 GE CO M PAN CRQSBY CRO SBY WR EHTHAQ MASS ~ Y L kyJ f) 2-Gc f 8 FOR.'i HV-l FOR SAFETY Aha) SAFE Y RELIEF VPLVES Q.c.-ccD As Requited by the Provisions of the AS!K Code Rules DATA REPORT Safety and Safecy Relief Valves glBfR.

    l. !dznufactured by Crosb Valve & Case CoCN7hanv C3 Kendrick S M 9 " '.th 03".93 Hase and Address Nodal Nn. NB-65-BP-FN Order llo. N94275 Concraec Dace 4/24/79 haclonal hoard ho. N/A General. Electric Company, 175 Curtner OrAvenue., 205-AJ 986
    2. Nanufaccured For San Jose CA 95125 d er Ho.

    Hashe and. Address 3, DMner Washington Public PoMer SuPPly System, Richland, Washington 99352 Haae and Address 4 locat ion Type of plant Saf ety Relief D.lllee

                                                                    .~d Hanf ord Reservation, Richland, Washington 99352 dree   R    Pipe ddce                lnlec 4 Doedec Safety, Safety Relief. Pilot,                                 lneh     >    r laClr:nn .HaCh'ep:Cneh Pover Actuated
    
    6. Set Pressut>> (psig) 1195 575o Raced Temperature 5taNhped Capacitv 899,185 .Overpressure BlovdoMn (psig) 975 psig (Assembled V Hydroscacic Test (psig) inlet 2370 Ouc!ec 1100 si <Bodv Onl )

    (Apnlicable co Valves for Closed Sys er~ Only) Pressure Retaining Pieces Serial No. Material 5 oct i f !cat !on Ba" Stock, 6 c'orgings ident if!cat ion Including Tvpe or Crade

    a. E'dh~~Ã Body No 18 0076 ASTH d5 A105-7'r.
                                                                                                 "~X SA105 Gr.             IIII AFi.! A105-71 Gr. TI Bonne t                                      N93407-35-0039                          AS<"- SA'05 Gr. II b     Ka      vi g..~~~~         D'sc Insert                  N93185-34-0089                           agNZ SA637 G=. 718 Nozzle                                        Dq     7 0                       >SR'A182 Gr. r316 Disc Holder*K55484 35 0083                  *. o'714- 4  ho
                                                       ~                                      14MS     5662B K 2856-~5-0095                          ASTM       A105 Gr.
    

    Spring flashers K62858-35-0039 hn ~ ASNE SA'05 Gr. I Na3410 33-006 APC: SM93 Gr. B6 i. Adjusting bolt

                                                   'N89720-34-0073                            ASTM. A5      4-71 Tvpe 630 SpindlePoint K62873-35-0057                                                                             4 r7. e   630
    
    c. SpringK52858-35-0039 *N89722-0015 ASTM A304-66 Gr. 416' B

    Soinc e BallK62873-35-0057

    e. ~~~Fh N9 3213-0057 Stellite t6 Thrust Bearin Adaoter N93409-32-0059 ASifE SA193 Gr. B6 N93207-0681 thru 069 A 7' -r ~t onnet Stud (BW5 I17 ch
       ~
    

    Bonnet Stud Nut Inlet Stud (J87) N93210-090'hru 0912 (BW6) N93216-0683 thru 0694 Ao ..'..'ir~r AS.'E SA194 Gr. 2H Inlet'Stud Nut N93218-0687 thru 0698 AS.'lE SAl94 Gr. 2ii Ac] usting Bol But t "n N9 4s'-ia-DJ4'oo

    636'8-33-AG."f

    QQ1[ Lc4civu ivwyioiv Adjusting Bolt, and Thrust Bearing adapter, re~chining of che Body, Spring Washers, Bonnet, and Spindle Assembly, and:d adding an Adjusting Bolt Button Assembly. Nev Serialization is required unless ..indicated by an asterisk. Original nameplate removed and ne.e~ nameplate attached. C~TTFZC TE OF Com~rA:,CE We certify chat the statements cade in this report are correcc and chat this valve confo.m to the rules of construction of che . ARK Code for Nuclear Power Plant Components, Section Zii, Div. 1, 1971 Edition, Addenda No Addenda, Code Case No. Class {Dace) Date - d Signed C"eosbv Valve & Gage Co. by

                                                    ..{H Cert,'ficate Holder)
    

    Our ASHE Certificate of Author~citron Ho. 1878 to use the symbol expires Se tember 30 . 1983 (Dace) TiFiCATiON OF DESiGN I Design info~ation on file ac Crosby Valve & Ga e Com ana Stress analysis report (Class 1 oozy) on f'le a. Crosbv Valve & 43 Kendrick St"eet Wrentha= '.f~ssnchusetts [ Design speci f icac ions cer t' ied by Bovd P. Brooks P:- Scare Califorhia Reg. No. ress report certified by W.D. Greenlav'eg. State Massachusetts No.' 4

    '-nature no" required - 1's= w~ - only. ~ + Q. tc i ~ 1 L'I ~ 4L04
                                            ~T:FECATE        OP SHOP iNSPECTTON i,  the urdersi@ed, holding a n'i== coc='ssion issued by the Nacional Board of Boile" an" Pressure Vessel Inspectors and the . Stace o= Province o Massachusetts and ewloyed by:actorv .iucual Svs-"em*                      of Notvcod ..Pssachuset-have inspected the pump, or valve, described in this Data Report and state that to the bes- of ~ ~ovledge and belief, the N Certi" cate Holder has constructed this pump, or valve, -n accor"-nce vich the ASH Code for Nuclear oc:er Plant Components.
    

    on, 19 By s'gn'ng this certi icace, neith~r tne inspector nor his employer ~kes any c:arrant, expressed or i=plied, concerning -ae ecuipmenc oescribed in this Data Repo=t. Furtner-more, neither the Inspector no= h'-s e 'oyer shall be liable in any ~reer for any persona'njury or property damge. or a loss o any kind arising =rom or connected vich th's inspect'on. Dace 'R 19 Signed Commissions M {inspector)~ (Hat'l. Bd., State, Prov. and No.)

     *Arh~rign -Boston Nanuiac urers 8"-tuaL insurac.ce              Cc oany          - '.1 =ual Boiler     & Nachinery          D 7X00380091
    
                                                                                                                                                                                                                                                ~   ~       r r         ~      r                           y         r    r r  ~
                                                 ~   ~               ~            ~                    r  ~
       ~  ~ ~                       ~ ~ ~              ~   ~     ~                        ~    ~            I                                           I ~
                                         ~       ~               ~                                ~ ~
       ~  ~ ~                        I          ~    ~         ~                ~ ~                   ~                                        ~   ~
    

    I ~ 4~ r \ ~

      ~         '        I                ~:                   I        ~               ~                         ~ ~                                 ~ ~ M
                                   ~             ~                                               ~      I
                 ~ ~                ~        '                                                      ~ ~                                    I ~            ~ ~     '
    

    I ~ I ~ I ~ ~ I I ~ I I ~ ~

      ~     ~   ~ ~                                    ~           r                                                                                                                                 ~
                                                                                                                                                                                                       ~                           '     ~
              ~   +  ~      ~ I
    

    ~ ~ ~ ~ ~ r ~ ~  : ~ ~ ~; r ~ ~ ~ r ~ ~

                                                                                                                                                                                                                              ~  I                                    ~ ~
        ~     ~ ~                                                                                                               I      ~                            ~   I     ~                                            ~   I       r  ~                        ~    ~
                                                                                                                                                                                                                            ~ I                            ~ o  ~    ~
                       ~       ~         I                  ~                                                             I '     ~      ~     I    ~           ~    I    I    ~      '
    

    I I ~ ~ ~ ~ ~

     ~    ~
    

    I ~ i~ ~ I ~ ~ I ~ I ~ I ' '

                                                                             ~      ~       I                                                                                      ~    '   '
                                                   ~     ~   ~   I    ~         ~       ~      ~    ~
                          ~     ~       ~                                             ~        ~       ~        I     ~
    

    I ' I ~ ~ I ~ I ~ ~ '

                              ~                  ~ ~           ~
                                                                         '                ~      ~ ~   ~      I         ~     I    '         ~   ~
                                                                               ~   r  ~                                      ~       ~                                ~   ~      t          ~   II It    '
    

    I I ~

                           ~ a                                                              0       0 ~               g 0            ~   I  y      g           I    ~
          ~       ~                       ~      ~                                                                                                                                       Q            ~             Q
                                            ~ ~                                                                                                                              ~ ~   ~
    

    J I ~ ~ ~ ~ I ~ ~ I I ~ ~ ~ 0 ~ 0 ~

                                                                                                                                      ~ ~                                              ~ I                   ~      ~
                                                              ~ ~
                                  ~ ~                    ~               I ~ ~        I   ~
                       ~     ~          ~          '                              ~      I ~ ~
                                              ~ ~      I   ~
     ~;      '       o           I                                                                                         ~    '
    

    I I ' ~ I ~ I ~ ~ ~ ~ ~

                                             ~     r                            ~          ~                                      ~  ~                    ~ '               ~    ~     ~         '
                                    ~                       ~                                                                                                          C
                               ~               ~                    J         ~                         ~   ~           0    '         ~      ~
                                                      ~               ~            ~            ~      ~        ~ ~ ~                                                                        ~     ~ ~
                                    ~
          ~    '                      ~                           '      ~        ~                             ~       ~ ~
          ~              ~                                               ~ ~    '                 ~                                              ~ '
                                                                 ~ '                                                        ~ ~                  ~    ~
                 ~ ~
                                                                                                                 ~       ~                  ~   ~
        '            ~                                                                                ~       ~                                                 ~    ~                                          ~ ~
    

    ~

                                                                                                                   ~  ~                                                                                  ~        ~
                                                               ~       '                                                           ~      t     ~       ~                                        ~  '
           ~       ~   ~ ~                           ~
    

    I ~ I ~ I ~ I ~ ~ ~ I

                                                                                                                                                                                                                                  ~    ~
    

    a ~ y o ~ e ~ ~ ~ s ~ ~

                                                                                                                                            ~         ~                                ~   ~
                                              ~  ~               ~                              ~ ~
      ~ ~ ~                           ~ ~ ~         ~ ~     ~  ~                    ~    ~                         1   ~
    

    1 ~ ~

        ~ ~                                   ~  ~                     '    ~            ~      ~                                  ~   ~
                                                                                              ~    4                                   ~ ~                                    ~ Ot         ~  ~
     ~         ~ ~      :           0     ~                                                           0 ~                                          ~            ~      ~ ~
                ~ ~               '                                                           ~ ~                             1 ~             ~           I                 ~   1 ~                               ~ ~ ~     ~   1    ~   ~
     ~    ~   ~ ~               l   ~     .        ~          ~                                                                            ~    ~           '                                                   '      ~  1   ~
             ~ ~
                    '         I         o   ~  ~                          ~      1     ~
    

    ~ ~ ~ ~ ~ ~ ~

                                                                                                                                                        ~     1                                            ~  1      ~                                 ~ ~
      ~     ~   ~                                                                                                1          ~                       ~   1   ~                                            ~  1      ~    ~                            ~   ~
                                                                                                                                                                                                                                             ~ ~
                                                                                                                                                                                                         ~ 1                                     ~ ~
    

    e o ~ ~ 1 ~ ~ 1 ~ ~ ~ ~

                ~ ~       ~                          ~     ~
                            ~              ~       ~   1         ~  ~    'I    ~   ~               ~      I  ~
                          ~ ~                  ~ ~       '         ~   1 ~    %1 ~
                  ~    ~        ~         '        ~
                                                                     ~ ~      ~       I                ~     ~         ~  ~                                                                                                        I   '
                                                                                                                                                                                                                                            ~ ~ I 1  ~                 ~ ~    .                     1      ~      ~  ~
                                                                                                               ~          ~                           ~         ~    0     ~ 1     1 ~   ~        ~  I
    

    r ~ r r r I ~ r ~ r ~ ~ ~ r: Q r ~: ~ ~

                                         ~     ~ ~               r           ~
    

    I ~ I J I I ~ ~ I ~ I ~ ~ I ~ ~ I ~ ~ ~ ~ I ~ ~ ~ I ~ J I ~ ~ ~ ~ ~

                                                                                                                                        ~     r         ~
                                                                                                                                       ~  ~                                                                ~     ~
                                                             ~ ~
                   ~ ~               J  ~                        ~     '
                                                                               ~      '     ~       \ ~
       ~      '           r  '               '    ~      I ~
         ~ S
                                                                                    ~   ~                                                                                                        ~      I ~
    

    I r

                                               ~    ~                                                                           ~     ~                        ~         ~   I   ~ ~   r   '
                                 ~              ~                                                      ~   ~           ~           ~    ~     ~    ~                                                   ~     ~
    

    J ~ ~ ~ ~ ~ ~ ~ ' ~ ~ r

                ~   '                                              ~ ~                                         ~  '      ~
    

    J ' ~ ' ~ ' ~ ~ '

                                                                                                                          ~ ~                    ~      ~
                      ~ ~
                                                                                                     ~          ~                           ~   ~                                                  ~     '         ~ ~
       ~    '                                                                                        ~       ~                                                       ~    ~
                                                                ~    '                   ~                        ~  ~                                                                               ~         ~
                       ~  ~ ~                                                                                                    ~        ~     J           ~                                ~           ~
                                                                                                                                                                           ~ ~ '                   ~ ~
    

    PLAN NO 2~14 KASNKGTOH PUBLIC POKER SUPPLY SYSTEM FORM NISH OLVNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: rrm3 Address: 3ooo Goorge Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nucfear Power Ptant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    9. (a) Work performed by': Washington public power Supply System (WppSS) 3tXO George Washington Way, Richland, WA
                                                                                         ~
    

    (b) Repair Organlsatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)

    4. Identlflcatlon of System: Sennco Water (SW) System
    5. (a) Applicable Construction Code: ASME Section III Code Ctass 3, 1971 Edition with Winter 1973 Addenda, Code Case: None P) APPllcable Edltlon of ASME Section XI Utlllzed for RePalrs or RePlacements: 1 960 Erfisonwith Wirrter 1960 Addenda, Code Case: N~
    6. IdentlfIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. BuIIt Replaced or Stamped No Replacemc.nt (Yes or No)

    Code Class SW-V@6 Borg Warner 23762 N/A N/A 1977 Repair Yes, Code Ctass 3

    7. Descrlptlon of Work: Made body to bonnet seal wekf for valve SW-Vm. The work was performed as foliows
    1) Cut valve body to bonnet seal weld
    2) Removed valvo intemais for troubieshooting
    3) Reinstaited valve internals and the bonnet
    4) Made valve body to bonnet seal weld
    5) Performed pressure test to confirm pressure boundary integrity. No evidence of feakage during the pressure test

    PLAN NO 2~1 lrASHIXGTOM PUBIJC PotrER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 0 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other None Test Pressure: at s Psig Test Temperature: es F Component Design Pressure: srxo Psrg Temperature: torP F

    g. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section Xl Type Code Symbol Stamp: Not appi'cable Certificate Authorization No.: Not applicable EXplratlOn Date: Not Apprcabre Prepared by o ~

    C~ r

                                                  ~         Signed by Mater'Andln                                          Manager, Materials And Inspection Date              7x                                 Date            7- Z6'- 7 CERTIFICATE OF INSERVICE INSPEC77ON I, the undersigned,   holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwnght Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken conectlve measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section M By signing this certlflcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report.
    

    Furthermore, neIther the Inspector nor his employer shell be liable In any manner for any personal Infury or property damage or a loss of any kind arising from or connected with this Inspection Commissions Inspects Signature National Board, State, and Endorsements Date T HN

                                                                                                                                                                                                                                                 ~    ~
                                                                                                                                            ~ ~
    

    r r~ ~ r r ~ r ~ r r ~

                                                                                                                                                                                                  ~ ~
                                                                                                ~ ~
     ~  ~ ~                     ~ ~ ~               ~      ~ ~         I            ~    ~                                         I          ~   ~
    

    t ~ I ~

     ~  ~ ~                       I       ~   I                       I  I   ~            ~                                           ~   ~
    

    1 ~ ~ ~ ~ ~ ~ ~ t ~ t I ~

              ~ ~    :        ~       ~    :                    ~                 ~                      ~ ~                                                                   ~   ~         ~  t 1        ~          ~
               ~ ~                                                                            ~ ~                               ~ ~               ~ ~   .                                                                      ~  ~         ~           ~       I         ~
    

    t '

           ~  ~ ~                               ~           ~        ~          ~                                                               ~        ~            ~                                                      I             I ~
             ~ ~         I          ~   ~ ~
    

    ~ ~ ~ ~ ~ ~ ~ ~ ~ . ~ ~ ~ 1 ~ ~ I ~ I ~ r ~

      ~      ~ ~                                                                                                                                            ~  '                                                     ~   1       ~       ~                        I     ~    ~
                                                                                                                                                                                                                                                                      ~        ~
                                                                                                                                                                                                                                                              ~ ~
                                                       ~    ~        I                                                                                                                                                                                            ~ ~
                    ~     ~                                                                                 I ~   ~   ~ ~      ~    ~                     I        ~      ~                                              I   ~           ~         t I     ~
                                   ~ ~ ~         ~     t~
    

    I ~ I ~ ~

                    ~       '                        I           !     t                                                                                                                  I       ~   I ~
                                                                                                                                                  '                                                                                I I     ~              I          I     '
    

    1 ~ I ~ ~ ~ ~ ~ ~ ~ ~

                                  ~       I                                         ~   I   '      ~
                  ~                     ~  ~ ~           t   ~ ~         I
                    ~           ~                                I I   ~              I              I     ~  I     '                                                              ~ Ij  ~
                    ~       ~   ~    ~                                     ~   t ~                                ~ ~        ~  I                                       ~   I  ~ ~            I ~     ~       ~ I ~ ~
    

    PLAN NO 2%915 XASHIMGTOH PUBUC POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure X Other None Test Pressure: gl S psig Test Temperature: ss F Component Design Pressure: ssoo Ps g Temperature: 100 F

    9. Remarks: None CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Of Authorization No.: Not applicable Expiration Date: Not Applicable Prepared By O ~a
                                             -~4    I 4      Signed By Materials And Inspection                             Manager, Materials And Inspection Date                           /      3               Date               H- rW-VZ CERTIFICATE OF INSERVICE INSPECTION I, the
                                                                                         ~3 undersigned, holding a valid commission Issued by the Natlona/ Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components,
                                                                ~Z->>.
    

    state to the best of my knowledge and belief, the Owner has perlormed examinations and taken corrective measures described In this Owner's Report in accordance with the requirements of the ASME Code, Section XI By signing this certifIcate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions 5 Ins or's Signature National Board, State, and Endorsements Date

    PlAN NO 2~11 trAstuHGTON pustlc potrxtt SUPPLY SYSTEM FORM NISH OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provlslons of the ASME Code Section XI

    1. Owner: Washington Public Powor Supply System (WPPSS) Date: 7/29/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Pubtk: Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WN P-2 Addresst Hanford Reservation, Benton County, Washington
    3. (a) )/i/ork performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair OrganlZatlOn P.O. NO, JOb NO, etC.: Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon of System: Servce Water (SW) System S. (a) Applicable Construction Code: ASME Section III Code Crass 1, 1974 Edition with Summer 1975 Addenda, Code Case: None (b) Applicable Edltlon of ASME Section XI Utlllzed for Repairs or Replacementst t 980 Edition with 1/I/inter 1980 Addenda, Code Case: N~
    6. Identification of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I,D. Built Replaced or Stamped Ho Replacement (Yes or No)

    Code Class SW-V-109A Borg Warner N/A N/A 1978 Repair Yes, Code Qass 1 internals

    7. Desctlptlon of Work: Made body to bonnet seal weld for valve SW-V-1 09A. 'The work was performed as follows
    1) Cut valve body to bonnet seal weld
    2) Removed valve internals for troubleshooting
    3) Prepped cut/ground aroas on the valve body and the bonnet
    4) Performed PT examination on the valve body and bonnet prepped areas. PT examination results acceptable
    5) Reinstattod valve and the bonnet
    6) Made valve body to bonnet seal weld
    7) Performed PT oxamination on the final seal weld. PT examination results acceptable
    8) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure tost

    PLAN NO 2~17 tfASHIHCTON PUBUC PONER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) S Tests Conducted: Hydrostatic ~ Test Pressure: 2t s Psig Pneumatic Nominal Operating Pressure Test Temperature: ceo F X Other None Component Design Pressure: 3NN Psig Temperature: sorP F

    9. Remarks: None CERTIFICATE OF COMPUANCE We certify that the statements made In this Owner's Report are correct and this repair conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Authorization No.: Not apprcable Expiration Date: Not Appt'cable prepered by O

    eeer. b Signed by AS7R ~ Materials And Inspection Manager, Materials And Inspection Date 2 3 Date 7-~- Ks CERTIFICATE OF INSERVICE INSPEC77ON I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures descrIbed In this Owner's Report In accordance with the reriulrements of the ASME Code, Section M By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions P5~ I s Signature National Board, State, and Endorsements Date - 9'8

    PLAN NO 2<I)23 XASHIHGTOII PVBUC POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Provisions Of The ASME Code Section XI

    1. Owner: Washington Public Power Supply System (WPPSS) Date: sit@93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nudoar Power Phnt (WNP) Unit: wNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed By: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon Of System: Main Steam (MS) System
    5. (a) Applicable Construction Code: ASME Section III Code Class 1, 1971 Edition with no Addenda, Code Case: None (b) Applicable Edition Of ASME Section XI Utlllzed For Repairs Or Replacements:19eo Edition with Winter 1990 Addenda, Code Case: N~
    6. Identiflcatlon Of Components Repaired Or Replaced And Replacement Components Name 01 Name Of Manufacturer 's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board /.D. BLIIIt Replaced Or Stamped No Replacement (Yes Or No)

    Code Class MS.RV-2B Crosby N/A 1980 Replacement Yes, Code Oass 1

    7. Descrlptlon Of Work Performed: Replaced disc insert and nozzle for mein steam relief valve MS.RV-28, Serial No N637SHO-0049. The replacement work was performed as follows
    1) Removed existing disc insert and nonie from the valve
    2) Installed new disc insert and nonle in the valve
    3) Reinstalled the valve
    4) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2<92 NASHINGTOrr PUBUC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure X Other None TeSt PreSSure:1OO5/8.79 Psig Test Temperature: 538/90.4o F COmpOnent DeSlgn PreSSure: 1250/500 Psig Temperature: 575/47Oo F

    9. Remarks: 1) Nominal operating pressure test on relief valve inlet flangod joint - test pressuro of 1005 Psig and test temperature of 538 F, 2) Pneumatic tost on relief valve outlet joint, body to bonnet joint, nozzle ring and adjusting ring sot screw joints - test pressure of 6.79 Psig andtestternporaturo of904 F,3) Componentdosign prossuroand temporature-1250Psig at575 Ffor relief valve inletpiping and500 Psig at 470o F for rolief valvo outlet piping, 4) Relief valve sot pressure and rated temperature -1175 Psig at 575 F CERTIFICATE OF COMPLIANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applicable Certificate Of A'uthorlzatlon No.: Not applicablo Expiration Date: Not Applicable Prepared By Signed By Materials And Inspection Manager, Materials And Inspection Date 3 Date 8- /6'-

    CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described In this Owner's Report In accordance with the requirements of the ASME Code, Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal InJury or property damage or a loss of any kind arising from or connected with this Inspection Commissions AJ Ins s Signature National Board, State, and Endorsoments Date

    PLAN NO 2~26 XASHIHCIOH PUBLIC POXER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required By The Prot/Islons Of The ASME Code Section XI

    1. Owner. Washington Public Power Supply System (WPPSS) DBfe: 8/1 8/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of 1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP-2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed By: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.: Washington Public Power Supply system (WppSS)
    4. Identlflcatlon Of System: Main Steam (MS) System
    5. (a) Applicable Construction Code: ASME Sactfon III Code Class 1, 1971 Edition with no Addenda, Code Case: None (b) Applicable Edltlon Of ASME Section XI Utilized For Repairs Or Replacements:1980 Edition with Winter 1980 Addenda, Coda Case: N~
    6. Identificatio Of Components Repaired Or Replaced And Replacement Components Name Of Name Of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial No Board I.D. Built Replaced Or Stamped No Replacement (Yes Or No)

    Code Class MS.RVQB Crosby N 63790404053 Replacement Yes, Code Class 1 ex'. Dascrlptlon Of Mfork Performed: Replaced disc insert and nozzle for main steam relief valve MS-RVQlf, Serial No N6379040-0053. the replacement work was performed as follows

    1) Removed existing disc insert and nozzle from the valve
    2) installed new disc insert and nozzle in the valve
    3) Reinstalled tha valve
    4) Installed two (2) naw nuts and one (1) new stud for the valve inlet nozzle
    5) Performed pressure test to confirm pressure boundary integrity. No evidence of leakage during the pressure test

    PLAN NO 2<926 XASHlNGTOM PUBUC POWER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic X Nominal Operating Pressure X Other None Teat PreSSure: 1OOS/6.78 Psig Test Temperature: 538/90.4 F COmpOnent DeSlgn PreSSure:1250/500Psig Temperature:575/47O F

    9. Remarks: 1) Nominal operating pressure tost on relief vahte inlet ftanged joint - tost pressure of 1005 Psig and test temperature of 538 F, 2) pneumatic test on relief valve outlet joint, body to bonnet joint, non@ ring and adjusting ring set screw joints -test pressure of 6.78 pslg and tost temperature of 90.4 F, 3) Component design pressure and temperature - 1250 Psig at 575 F for relief valve inlet piping and 500 Psig at 470 F for relief vahto outlet piping, 4) Relief valve sot pressure and ratod temperature - 1185 Psig at 575 F CERTIFICATE OF COMPUANCE We certify thaf the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section M Type Code Symbol Stamp: Not applicable Certificate Of Authorization No.: Not applicable Expiration Date: Not Applicable 0 C7 /

    Prepared By Signed By Materials Inspection Manager, Materials And Inspection Date 1Z Date B -i8-":S CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components and state to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report In accordance with the requirements of the ASME Code, Section XI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or Implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal In/ury or property damage or a loss of any kind arising from or connected with this Inspection Commissions WS/AJ In or's Signature National Board, State, and Endorsements Date H-/ - 9

                                                                                                                                                                                                                                     ~ ~            ~         Ij 0   g               ~ o                ~   ~   r     ~        s        o     ~
                                                                                                                                                                                      ~ ~
                                             ~   ~                                      ~ ~
       ~  ~ ~                          ~ ~         ~  i         i            ~   ~
                                                                                    ~ ~
       ~    ~                                                   i      ~                ~                                   ~  ~
          ~
                                                                                                                               ~ ~                                          ~ ~ ~        ~    ~  ~                ~    ~                 I   ~
                                 ~        ~                                                     ~ ~                                                                             ~ ~
                                   ~         ~
             ~   ~ ~                                                                  ~ ~                                             ~ ~     0    I                      ~   \          i             ~ ~ ~    ~   i       ~
                                                                                                                                                                                                                        '        i ~
            ~   ~ ~            j   ~                                                                                               ~        ~                                                                                 ~
               ~ ~       ~  I          ~   ~
       ~                                                     ~ ~                              ~  j          ~    ~        '      '            j       ~         '                            ~       ~ ~
    

    ~

                                                                                                                                                                                                                  ~   j     ~                                ~   ~
        ~     ~ ~
                                                                                                                                              ~   j     ~                                                     ~    j      ~    ~                   j      ~     ~
                                                                                                                                                                                                             ~    j                                    ~          ~
                                                                                                                                                                                                                                               ~ ~           j
                                                          ~    ~                                          ~   ~ ~    ~ ~                                                                                                                           ~ ~  .   ~
                     ~        ~          ~                                                          ~   i       ~  ~                 i    ~     ~   8         t       !                                                                    ~               ~   ~  t
    

    ~ ~ i i ~

                                                                                      '     '          ~
                       ~         ~         i i     ~ ~                            ~      ~  rj        ~       ~
    

    i i ~ ~ ~ i ~ ~ e i i

                             ~     ~                      ~ ~         ~     i
                     ~              ~   ~                           ~    j'                                 ~ ~                                                                                    ~  i      ~
    

    j ~ ~ I ~ I ~ ~ ~ ~ j ~ ~ ~

                                                                                                                                                                                           '        i    ~
    

    0 ~ I 1

                                                                                                                                ~ ~
                                                                                                                                  ~        o         o     ~               y                 ~        ~
                  ~        ~                       ~     ~         1 L      ~ ~
    

    Nm e. Rm ~ L

                                                      ~ ~                                                                            ~    ~ ~             ~
    

    I ~ ~ I ~ 4 ~ ~ ~ ~ ~ ~ I ~ ~ ~ + ~ I~ ~ ~ 'I ~ ~ 4 ~ I ~ ' ~ ~ ~ I ~ ~ I ~ ~ I ~ ~ ~ 0 ~ ~ ~ ~ ~ ~

                                                                                                                                                      '                       ~        ~                                                       ~ ~   ~   I    ~ ~ t
       ~ I '                              I      ~      ~  ~    4     ~      ~                    ~       \              ~                      ~       I    ~ 0    ~      ~     I
                                                                                                                                                      ~     ~                                                           ~ I                    ~     0
                                                                          ~ ~
           ~  '           ~               ~ ~                      ~          ~      I  ~ ~
                                                                                               ~    I ~  ~     I  ~
            ~   1      ~
    

    I

                                                       ~ ~
    

    I I ~

                                                                               ~
    

    r

                                                                                           ~ '       ~                                                                                                                               ~   '     ~
                         ~           ~    '           ~    ~          ~               '              ~                                         ~     ~                               ~    1      r    ~ 1      ~    ~   ~
                                                                                                                    ~   ~;           ~           ~      ~       '       ~                                                                    ~     ~
                                               ~                ~        I        ~             ~                 ~       ~ ~ ~                                                                                               ~     ~ ~
                   ~   '                                                        ~ ~                                       ~   '        ~
                  ~            '      '                                              ~ ~    '               ~                                                          ~        ~
                                                                            ~   '                                                       ~ ~                            ~     ~
                         ~ ~
                                                                                                                 ~    '                                           ~   ~                                                                                ~    ~
                                                                                                                 ~      ~                                                                      ~    '                                            ~ ~
                  ~           ~
                                                                                                                                  ~                                 '
                                                                                           ~           ~                      ~                                  ~
                   ~        0    ~ ~               1       1 ~ '                   '                 ~                                          ~            ~        ~         ~          '           ~                          ~  '
                                        ~
                                           '                                                                                                                                            ~         I        ~ I   4    I     I   ~       ~  4
    

    MWR HO AP 0797 XASHIHCTOH PUBUC PONER SUPPLY SYSTEM FORM NIS-2 OWNER'S REPOR7 FOR REPAIRS OR REPLACEMEN7S As Required by the Provfslons of the ASME Code Section XI

    1. Owner. Washington Public Power Supply System (WPPSS) Date: 6/1 6/93 Address: 3000 George Washington Way, Richland, Washington Sheet:1 of1
    2. Plant: Washington Public Power Supply System (WPPSS) Nuclear Power Plant (WNP) Unit: WNP.2 Address: Hanford Reservation, Benton County, Washington
    3. (a) Work Performed by: Washington Public Power Supply System (WPPSS), 3000 George Washington Way, Richland, WA (b) Repair Organlzatlon P.O. No, Job No, etc.:Washington Public Power Supply System (WPPSS)
    4. Identlflcatlon of System: Mein Steam (MS) System
    5. (a) APPllcable Constr uctlOn Code: ASME Section III Code Class 2, 1971 Edition with Winter 1973 Addenda, Coda Casa: Nona (b) AppllCable EdltlOn Of ASMESeCtlOn XI UtIIIZed fOr Repalra Or ReplaCementa:

    1980 Edition with Winter 1980 Addenda, Coda Case: N~

    6. IdentlfIcation of Components Repaired or Replaced and Replacement Components Name of Name of Manufacturer's National Other Year Repaired, ASME Code Component Manufacturer Serial Ho Board I.D. Built Replaced or Stamped No Replacement P'es or No)

    Code Class MS(1) ~ MS(1) QB WPPSS WPPSS MS(1) AA MS(1) AB N/A N/A N/A N/A 1984 1984 Replacement Replacement Yas, Code Class 2 Yes, Code Class 2

    7. Descrlptlon of Work: Replaced snubbers for supports MD128514A and MD128711. The replacement work was performed as follows
    1) Removed exisbng snubber with Serial No 401 1 and replaced it with new snubber with Serial No 2473 for support MD-1 286-1 4A
    2) Removed exisbng snubber with Serial No 379 and replaced it with new snubber with Serial No 293 for support MD 1287 11

    MWR NO AP 07g7 tfASHINGTOH Pusuc POWER SUPPLY SYSTEM I I FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS (Back) 8 Tests Conducted: Hydrostatic Pneumatic Nominal Operating Pressure Other X Test Pressure: Pslg Test Temperature: F Component Design Pressure: p~ Temperature'o F R Remarks: Snubber operability test performed on the replacement snubbers CERTIFICATE OF COMPUANCE We certify that the statements made In this Owner's Report are correct and this replacement conforms to the rules of the ASME Code, Section XI Type Code Symbol Stamp: Not applcable CertiflCate AuthcrIZatlcn NO.: Not applicable Expiration Date: Nct Applicable Prepared by AJ Materials And Inspection Signed by cK ~ Manager, Materials And Inspecticn Date Date C.z@- CERTIFICATE OF INSERVICE INSPEC77ON I, the undersigned, holding a valid commission Issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Washington and employed by Arkwright Mutual Insurance Company (Factory Mutual Engineering Association) of Norwood, Massachusetts have Inspected the components

                                                                                                    ~4.
    

    state to the best of my knowledge and belief, the Owner has performed examinations and taken ASME Code, Section ¹ conectlve measures described In this Owner's Report In accordance with the requirements of the By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described In this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable In any manner for any personal inJury or property damage or a loss of any kind arising from or connected with this Inspection. Commissions 5>w $2 ns pector's Signature National Board, State, and Endorsements Date}}