ML17289B056

From kanterella
Jump to navigation Jump to search
Forwards Enforcement Conference Rept 50-397/92-42 on 921110. Issues Discussed at Meeting Related to 920815 Core Power Oscillation Event
ML17289B056
Person / Time
Site: Columbia 
Issue date: 12/01/1992
From: Perkins K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Oxsen A
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
Shared Package
ML17289B057 List:
References
EA-92-206, NUDOCS 9212280288
Download: ML17289B056 (6)


See also: IR 05000397/1992042

Text

k'ORB 1

REGULATG Y INFORMATION DISTRIBUTIO

YSTEM (RIDS)

ACCESSION NBR:9212280288

DOC.DATE: 92/12/01

NOTARIZED: NO

DOCKET

FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public

Powe

05000397

AUTH.NAME

AUTHOR AFF1LIATION

PERKINS,K.E.

Region

5 (Post

820201)

RECIP.NAME

RECIPIENT AFFILIATION

OXSENPA.L.

Washington Public Power Supply System

4

SUBJECT:

Forwards enforcement

conference

rept 50-397/92-42

on 921110.

Issues

discussed

at meeting related to 920815 core power

oscillation event.

DISTRIBUTION CODE:

IE45D

COPIES

RECEIVED:LTR I

ENCL $

SIZE: Z 7 Z9

TITLE: Summary of Significant Meeting with Licensee

(Part

50)

S

NOTES:

RECIPIENT

ID CODE/NAME

PD5

LA

INTERNAL: AEOD/DOA

DEDRO

NRR/DREP/PEPB9D

NUDOCS~STRACT

@EG FI

RGN5

FILE

01

COPIES

LTTR ENCL

1

0

1

1

1

1

1

1

1

1

1

1

1

1

RECIPIENT

ID CODE/NAME

CLIFFORDEJ

AEOD/DSP/TPAB

NRR/DLPQ/LPEB10

NRR/PMAS/ILRB12

OGC/ROED

RES/DSIR/EIB

COPIES

LTTR ENCL

1

1

1

1

l.

1

1

1

1

1

1

1

EXTERNAL: NRC PDR

1

1

NSIC

1

1

NOTE TO ALL RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK.

ROOM Pl-37 (EXT. 504-2065) TO ELIMINATEYOUR NAhlE FROM DISTRIBUTION

LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES

REQUIRED:

LTTR

15

ENCL

14

pe RF00g

~4

CI

&0

Cy

~i

0O

I

O~

+rg

(X

IP +>>*<<+

UNITED STATES

NUCLEAR REGULATORYCOMMISSION

REGION V

1450 MARIALANE

WALNUTCREEK, CAUFORNIA94596-5368

DECi

1992

Docket No.

50-397

License

No. NPF-21

EA 92-206

Washington Public Power Supply System

P. 0.

Box 968

Richland,

Washington

99352

Attention:

Mr. A. L. Oxsen

Acting Managing Director

Gentlemen:

SUBJECT:

Enforcement

Conference of November

10,

1992

This refers to the Enforcement

Conference

held in the Region

V office on

November 10,

1992, during which we discussed

issues

related to the August 15,

1992 core power oscillation event.

The subjects

discussed

during the meeting

are described

in the enclosed

Meeting Report

No. 50-397/92-42.

A copy of the

meeting

agenda is also enclosed.

The information presented

during the Enforcement

Conference will be evaluated

and enforcement

action related to these

issues will be the subject of separate

correspondence.

At the Enforcement

Conference,

you discussed

the Supply System's position

regarding the apparent violations discussed

in Inspection Report 50-397/92-37

and the corrective actions which have

been initiated to address

these

issues.

The Supply System's failure to provide effective management

oversight

was

a

significant contributor to this event.

Your presentation

at the Enforcement

Conference

and your letter dated October 30,

1992, indicate that you

understand this concern

and that you have initiated actions which emphasize

responsibility

and accountability at all management

levels.

In accordance

with 10 CFR 2.790(a) of the NRC's "Rules of Practice,"

a copy of

this letter and its enclosures will be placed in the

NRC Public Document

Room.

Should you have

any questions

concerning this inspection,

we will be pleased

to discuss

them with you.

Sincerely,

9212280288

921201

PDR

ADOCK 05000397

PDR

K. E. Perkins,

Director

Division of Reactor Safety

and Projects

bcc w/copy of enclosure:

Docket File

Project Inspector

Resident

Inspector

B. Faulkenberry

J. Hartin

R.

Huey

H. Blume

J.

Lieberman,

OE

P. Johnson

J. Clifford, NRR

J. Hitchell,

OEDO

G. Cook

bcc w/o enclosure:

H. Smith

J. Bianchi

J. Zollicoffer

REGION

KJoh

s on

12/

( / 2

PJo

n

n

12/I /92

SRichards

12/

L /92

LHiller

12/( /92

RHuey

12/ I /92

EST

COPY ]

EST

COPY ]

EST

COPY ]

R

ST

COPY ]

EST

COPY ]

YES

NO

ES

NO

YES

NO

ES

NO

ES

NO

12/ )/92

T COPY ]

YES

NO

E

ES

NO

/g

Encl osures:

1.

Copy of the Enforcement

Conference

Agenda

2.

Heeting Report

No. 50-397/92-42

3.

Copy of Licensee's

Enforcement

Conference

Presentation

Haterials

cc w/enclosures

1 and 2:

J.

V. Parrish,

Assistant

Hanaging Director for Operations

J.

C. Gearhart,

equality Assurance Director

J.

W. Baker,

WNP-2 Plant Hanager

G. C. Sorensen,

Hanager,

Regulatory

Programs

A. G. Hosier,

WNP-2 Licensing Hanager

G.

E. Doupe,

Esq.

cc w/enclosures

1 3:

Winston

8 Strawn

State of Washington

ENCLOSURE

1

ENFORCEMENT CONFERENCE

WASHINGTON PUBLIC POWER SUPPLY

SYST'EH'ovember

10,

1992

~GENDA

1.

Opening

Remarks,

Purpose of Meeting J.

B. Hartin, Regional Administra-

tor,

and A. L. Oxsen, Acting Managing Director

2.

Review of Apparent Violations Related to the August 15,

1992 Core

Power

Oscillation Event P.

H. Johnson,

Chief, Reactor Projects

Section

1

3.

Discussion of Safety Significance of Apparent Violations K. E. Perkins,

Director, Division of Reactor Safety

and Projects

4.

Licensee

Response

to and Discussion of Apparent Violations Supply

System

5.

Review of NRC Enforcement Policy F.

R. Huey, Enforcement Officer

6.

Other Discussion

5.

Concluding

Remarks J.

B. Martin, Regional Administrator