ML17286B017

From kanterella
Jump to navigation Jump to search
Forwards Root Cause Analysis Summary, Unsatisfactory Licensed Operator Requalification Program, Resulting from Failure of Two Crews & Three Operators During Requalification Simulator Exam Retakes on 910605 & 06
Date released: 06/27/2018 Download: ML17286B017


Root Cause Analysis Summary, Unsatisfactory Licensed Operator Requalification Program, Reflecting Causes of Operators Continued Inability to Respond to Severe Accident Conditions
ML17286B021
Person / Time
Site: Columbia 
Issue date: 08/20/1991
From: Muth J, Schumann D
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To:
References
Download: ML17286B021 (120)
Forwards Root Cause Analysis Summary, Unsatisfactory Licensed Operator Requalification Program, Resulting from Failure of Two Crews & Three Operators During Requalification Simulator Exam Retakes on 910605 & 06
ML17286B016
Person / Time
Site: Columbia 
Issue date: 08/20/1991
From: John Baker, Oxsen A, Sorensen G
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: MARTIN J B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
Download: ML17286B016 (12)