Text

~8 RE00~

~4

~o Cy 0O IlA9 Cy

+g 'O

+a*++

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON> D.C. 205M-0001 ENERGY NORTHWEST.

DOCKET NO. 50-397 WNP-2 AMENDMENTTO FACILITYOPERATING LICENSE Amendment No. 159 License No. NPF-21 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by the Energy Northwest (licensee) dated April 20, 1999, as supplemented by letter dated September 9, 1999, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's regulations set forth in 10 CFR Chapter I; B.

The facilitywilloperate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities willbe conducted in compliance with the Commission's regulations; D..

The issuance of this amendment willnot be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. NPF-21 is hereby amended to read as follows:

99iOi20233 99i006 PDR ADQCK 05000397 P

PDR

',fi I

(2)

Technical S ecifications and Environmental Protection Plan The Technical Specifications contained in Appendix A, as revised through Amendment No.159and the Environmental Protection Plan contained in Appendix B, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

3.

The license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORYCOMMISSION Stephen Dembek, Chief, Section 2 Project Directorate IV8 Decommissioning Division of Licensing Project Management Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

October 6, 1999

l II fy f'

ATTACHMENTTO LICENSE AMENDMENTNO. 159 FACILITYOPERATING LICENSE NO. NPF-21 DOCKET NO. 50-397 Replace the following pages of the Appendix A Technical Specifications with the attached revised pages.

The revised pages are identified by amendment number and contain vertical lines indicating the areas of change.

REMOVE 3.4-28 3.4-29 3.4-30 INSERT 3.4-28 3.4-29 3.4-30

i l

I

RCS P/T Limits 3.4.11 1400 1300 1200 1100

$000

~<900

~o800

~~ 700 a 600

~ 500

~ 400 300 200 (110 F,66 psig)

(11 F,3 2psi

( 0 F, 12psi 100 0

0 50 100 150 200 250 300 350 400 450 500 REACTOR METALTEMPERATURE (CORE BELTLINE,F)

Figure 3.4.11-1 (Page 1 of 1)

Inservice Leak and Hydrostatic Testing Curve WNP-2 3.4-28 Amendment No. ~,159

liI h,

Ii

RCS P/T Limits 3.4.11 1400 1300 1200 1100

$ 000

~z900 oo 8QQ

~ 700 I600 g 500

~ 400 0

300 200 100 (1 '0 F, 1 8 psi 0

0 50 100 150 200 250 300 350 400 450 500 REACTOR METALTEMPERATURE (CORE BELTLINE,F)

Figure 3.4-11-2 (Page 1 of 1)

Non-Nuclear Heating and Cooldown Curve WNP-2 3.4-29 Amendment No. +8;159

RCS P/T Limits 3.4.11 1400 1300 1200 1100

$ 000

~ 900

~o 800

~+ 700

~ 600 8 500 400 300 200 100 OF (15 F, 1 psi 58 si 0

0 50 100 150 200 250 300 350 400 450 500 REACTOR METALTEMPERATURE (CORE BELTLINE,F)

Figure 3.4.11-3 (Page 1 of 1)

Nuclear Heating and Cooldown Curve MNP-2 3.4-30 Amendment No. ~,159

~ ~

0 I

k lg 1I a