WASHINGTON PUBLIC POWER SUPPLY SYSTEM PROCEDURE NUMBER

+12. 10. 6 APPR D

VOLUMELIAME 12 'HEMISTRY PROCEDUR SECTION 12.10 POST ACCIDENT SAMPLING AND ANALYSIS TITLE

+12e10.6 IODINE AND PARTICULATE FILTER ANAI YSIS DATE 06/21/83 12.10.6.1 P~ur ose This procedure describes the analy'sis of iodine and particulate filters taken, from the post accident sample station.

12.10.6.2 Precautions/Prere uisites A.

Using calibrated portable dose rate meters survey sample to determine dose rate.

B.

Samples must be sealed in plastic bags prior to counting on the gamma spectrometer.

12. 10.6. 3 E~ui ment None 12.10.6.4 R~ee ents None 12.10.6e5 Procedure A.

Count samples on gamma spectrometer loaded face side down.

83070SOib7 830b23

. PDR ADQCK 05000397 I

~E PDR IHIP 597 R I PROCEDURE NUMBER REVISION NUMBER 12.10.6 PAGE NUMBER 12.10.6-1 of 2

~d-~-IOB f j/jQ~~fgj J

/

f B.

Calculate as follows:

~

uCi/cc = (A)(e~tl)(D B

C A = uCi of isotope identified B = Collection period in minutes C = Sample flow rate in cc/min y

d ll ll l

decay constant of specific nuclide (sec-1) tl = tim from sampling to counting (seconds) t2 = duration of sample period in seconds Record results in post accident analysis log.

W~99