Flow Diagram Sampling System.Sheet 152
ML17276B259
Person / Time
Site: Saint Lucie 
Issue date: 08/15/1997
From:
CATALYTIC, INC. (SUBS. OF AIR PRODUCTS & CHEMICALS
To:
Shared Package
ML17229A541 List: ... further results
References
2998-G-078, 2998-G-78, NUDOCS 9712180012
Download: ML17276B259 (1)


Text

2998 G 078 SH 152 REVISIONS NO DATE 7-24-95 DESCRIPTION BY CH -

APPROVED BB DWC JJZ Ictr

0 IIIIIII Sl}s)97 GM

~

~

~

~

~

~

~

~

~

ECZMM7048:

REV: (86) PIPING, (E5,E6)

ABANDONED AND ADO NOTE 8, DEL (86)

DRAWING CORRECTION

}

z6 Z

5

(}

o~~

CC 03 Z

LDz Z

rn FROM CCW SUPPLY 2998-G-083 SH 2 CC G6 TO 0"W RETURN 2998-G-083 SH 2 CC F4 FROM SAMPIE INLET 2998-G-078 SH 153 SS D7 3/8-65-579 3/8'ROM OEMIN WTR PUM 2998-0-084 SH 2 DWS miSO Vseiei I

HIC S734 vsies 3/4.

FAI V5734 I

I HS 5763 N/5 FC V5763 I

I I

x::

CLOSES V5740 ON 1 HIGH PRESSURE N/5 DISSOLVED H2 ANALYZER V05102

,I 508 508 V05106 V05105 V05101 F- ~S (NOTE 3)

IN/5 5765 CL 4J 4J In 40 cn ~

)

4J O

I In OI OI)

TO HEAT TRACE CO Ol 0

5747 (NOTE 3)

I 0

V5719 5731

/

/5 GAS RESIDENCE CHAMBER FC O

V5731 502 502 HS 5741 Ot CO V5741 H

PIA

~A 503 (NOTE 4)

CLOSES V5763 ON HIGH PRESSURE FI

~

~

~

5749 5

N/5 -~sseFRF SURGE BULB V5747 C I/

(NOTES 1

ec 7)

V5718 HS V5720 SAMPLE CIRCULATION PUMP HS 5743 N/5 FC V5743 V

U LT 503 503 DR HS 5745 N/5 FC V5745 V5746 V5748 GAS SAMPLE VESSEL 5742 N/5 (NOTE 3)

(NOTES 2 k 5)

V5742 V5710 I/I rJ)

~ 4/

cn 4 CO W 0 I/I 4/

00 O C3 V5711 V5762 HS 57SI D2 METER N/5 504

~

505 CONTAINMENT SAMPLE PUMP DR OI 0)

~

~

CONTAINMENT SAMPLE YESSEL

~

~

~

HS 5

5760

~ 5 N/5

~

FI FC 503 V5760 V5705 P

M E

OT V

DR SURGE VESSEL PUMP V5706 5733 FC

~

~

~ V575 I ~

~

~

~

~

~

~

~

~

HS

~

~

HS 5799 S

VENT TO CABINET EXHAUST FILTER V5799

~

H2 METER 505

~

~

CO COI 5750 gs N/SoF ~

OI0 I)

HS 5756 ee HS 5767 S

N/S oF N/5 V5758 502 S

HS 5771 S

N/5 YS702 5772 N/5 CO I)

)0 FC 5753 S

N/S~~~

VENT TO HOOD ELECTROUTE STORAGE VESSEL X=

DR HS 5735 N/5 tnI I) 502 AE BORON METER 2

A E

N E

8 I

V5794 HS 5752 N/5 5 4 V

CO V5712 PT 505 V5703 ce X "=

TEST BURETTE 502 502 X-:

DR V5713 V5704 HIC 5732

/

N/5 FC$

5773 5797 S

r O

tn)

FC V5797 HIC 5768 V5714 SURGE YESSEL V5768 V5715 s7es HS

/5 FC V5709 HIC 5736

~

I

/

N/5

~FC D

FROM CNTMT ATMOS 3/6-56-569 2998-G-078 SH 153

~

~

SS G4

~

I TO CNTMT ATMOS 2998-G-078 SH 153 SS H4 3/e-ee-sso

'll

'/

3/6-WM-E54 V06411 V06410 FROM N2 PCV V7219 2998-0-078 SH 1638 WM E3 FROM V7270

}R N2 HDR 2998-G-078 SH 1638 WM E3 3/e-es 653 L ~)

V5716~

CONTROL PANEL D

1/2-65-654 FROM N2 PCV V7273 2998-G-078 SH 1638 WM F3 4/

CJ I

I I

D TQ GRB SLTPL/EQ DR TK 2998M-078 SH 153 SS E7 3/e-es-ses

'I~'-QRPAATtog Oi)L,Y

-.~IPY (', IT)'

CONTROLLED MPY EIEFORE USE NOTES MECH 2998 G 078 PTL 8

BLUM CHC CUNNINGHAM SHEET 152 URNooieo.owo 1.

JgJC, DESIGNATES A 4-WAY VALVE; FLOW ENTERING IHE VALVE

~

WILL CONTINUE AT 90'URNS ONLY.

POSITIONING OF I //'HE VALVE WIlL ALLOW FLOW TO PASS EITHER QNE WAY (L) SINGLE ARROW OR THE OTHER WAY Q DOUBLE ARROW THE SINGLE ARROW DEPICTS THE NORMAL POSITION, 2.

I DESIGNATES A 4-WAY VALVE WITH NORMAL POSITION

~ ALLOWING STRAIGHT THROUGH FLOW AND THE OTHER POSITION ALLOWING FLOW THROUGH THE VERTICALLY PATH SHOWN.

3.

DESIGNATES A 4-WAY VALVE WITH NORMAL POSITION OF N/5 4CX THREE OPEN PORTS AND N2 SUPPLY ISOLATED BY THE FOURTH PORT.

4.

ALARMS ARE ANNUNCIATED AT THE POST ACCIDENT SAMPUNG SYSTEM CONTROL PANEL I

E, 5.

VALVE FAILS TO NORMAL POSITION UPON LOSS OF POWER AND AS IS UPON LOSS OF AIR 6.

ALL EQUIPMENT ON THIS DRAWING IS LOCATED WITHIN IHE PASS STATION.

7.

N/5 INDICATES THAT NITROGEN IS SUPPLIED TO THIS VALVE FOR OPERATION FROM THE NITROGEN HEADER WITHIN THE SKID.

8.

EQUIPMEiVT IS ABANDONED IN PLACE. AND NON FUNCTIONAL REFERENCE DRAWINGS

PIPE, VALVE k INSTRUMENT SYMBOLS VALVE LIST LINE UST VALVE OPERATIONAL NUMBER INDEX INSTRUMENT INSIALIATION DETAILS INSIRUMENT LIST 2998-G-078 SH IDO 2998-A-051 2998-8-052 2998-8-057A 2998-8-231 2998-8-2700 I

I I

%$ I 5 IBBI Oc RI coRDR TNICUI/HITCONTROL CENTER

)

")

I I

I I

I

)

H(

I "I

I 9

I}C RLC DODO }TNTCONTROL CENTER NOTE:

THIS DRAWING IS MADE FROM REV.

OF DRAWING 2998-0-078 SH 152 REVISION OF THIS DRAWING MAY REQUIRE UPDATE OF THE FOLLOWING DOCUMENTS:

1.

FSAR FIGURE 9.3-3b I/M PASS VOLUME II 2998 13315 FLORIDA POWER ec UGHT COMPANY ST LUCIE PLANT 1983 890 MWe EXTENSION UNIT 2 FLOW DIAGRAM SAMPL)NG SYSTEM RAYTHEON ENGINEERS ts CONSTRUCTORS, INC SCALE: NONE APPROVAL DATE:

Q 7/ Q a (-(LaZ IG C) 6