ML17272A993
| ML17272A993 | |
| Person / Time | |
|---|---|
| Site: | Columbia, Washington Public Power Supply System, Satsop |
| Issue date: | 06/06/1980 |
| From: | Renberger D WASHINGTON PUBLIC POWER SUPPLY SYSTEM |
| To: | Youngblood B NRC COMMISSION (OCM), Office of Nuclear Reactor Regulation |
| References | |
| NUDOCS 8006110278 | |
| Download: ML17272A993 (4) | |
Text
t REGULATO INFORMATION DISTRIBUTION STEM (RIBS)
+Pil'/
ACCESSION NBRS8006110278 DOC ~ DATE: 80/06/06 NOTARIZED ~
NO DO FACIL:30-397 NPPSS Nuol ocr Projectr Unit Er Neenlngton, Publ lc Powe ~003 50 460 FJPPSS Nuclear ProJectg Unit ii Washington Public Powe 050000 0
50 513 HPPSS Nuclear ProJecti Unit Qi Washington,Public Powe 05000513 AUTH ~ NAME AUTHOR AFFILIATION
~P RENBERGKR<D.L, Washington Public Power Supply System RECIP ~ NAME RECIPIENT AFFILIATION Commission YOUNGBLOODFB ~ J.
Licensing Branch 1
SUBJECT:
Notifies that lab will be conducting addi'oisture testing on low hydrogen electrodes using technique required in ANS A5.5ESection 25 'lectrode coating moisture testing results will be applied only to Units 1,
8 3.
DISTRIBUTION CODE:
B001S COPIES RECEIVEDeLTR ENCL ~
SIZE:
J TITLE: PSAR/FSAR AMDTS and Related'Correspondence
~O~ES:
PJBu 2 ~~~ Pt~~Ctzt~uZlh24~ ttIEMEEWEl3Le&P&~6386%~1>Ãh WArT RECIPIENT COPIES ID CODE/NAME LTTR ENCL ACTION:
05 PMNLY<GH 1
0 RECIPIENT COPIES ID CODE/NAME.
LTTR ENCL AD ~
1 0
LA <~~ ~W,c.~~<3 1
0 INTERNAL: 01 06 I 8
E 09 GEOSCIEN BR il MECH ENG BR 13 MATL ENG BR 16 ANALYSIS BR 18 AUX SYS BR 20 I L
C SYS BR 22 AD SITE TECH 27 EFFL TRT SYS 29 KIRKHOOD AD PLANT SYS AD/CORE L
CONT HYDRO METEOR BR OELD EXTERNAL; 03 LPDR 30 ACRS 1
1 3
3
~
1 1
2 2
1 1
1 1
1 1
0 1
1 1
1 1
0 1
0 2
2 1
0 1
1 10 10 02 NRC PDR 08 OPFRA LIC BR 10 QAB 12 STRUC ENG BR 15 REAC SYS BR 17 CORE PERF BR 19 CONTAIN SYS 21 PONER SYS BR 26 ACCDNT ANLYS 28 RAD ASMT BR AD FOR ENG AD SITE ANLYSIS DIRECTOR NRR MPA OCI NSIC 1
.1 1
1 1
1 1
1 1
1 1
1 1
1-1 1
1' 1
0 1
0 1
0 1
1
~r>>>>
>S8O TOTAL NUMBER OF COPIES REQUIRED:
LTTR ~
ENCL
I l
/
M t
~
II
<<(
lJ f
lg 1 )
~
~
I n
Washington Public Power Supply System A JOINT OPERATING AGENCY P. 0. BOX 958 3000 GEO. WA4HINCTON WAY RICHLAND, WA4HINCTON 99352 PHONE (509) 375 5000 Docket Nos.
50-397 50-460/513 50-508/509 June 6,
1980 U. S. Nuclear Regulatory Commission Washington D.
C.
20555 Attention:
B. J.
Youngblood, Chief Licensing Branch No.
1 Division of Licensing
Subject:
MOISTURE TESTING OF LOW-HYDROGEN ELECTRODES
References:
I)
- Letter, L. S.
Rubenstein to N. 0. Strand, same subject, dated April 4, 1980 2)
- Letter, D. L. Renberger to L. S. Rubenstein, same subject, dated April 25, 1980
Dear Mr. Youngblood:
Mr. Rubenstein's letter of April 4, 1980 (Reference
- 1) requested informa-tion regarding implementation of the proposed electrode coating moisture testing technique.
In our letter of April 25, 1980, (Reference 2) we stated that the technique would be used for testing electrodes from all of our projects, (i.e.
WNP-1, 2, 3, 4 and 5).
However, since that writing, we have been able to make arrangements with a laboratory which will do moisture testing on low hydrogen electrodes using the technique required in Section 25 of AWS A5.5.
Therefore, to avoid possible future complications, we intend doing all additional moisture testing at that laboratory.
Accordingly, results from the testing technique approved in Reference I will be applied only to the WNP-1/4 projects.
Testing for the other projects, WNP-2, 3 and 5, and additional testing for WNP-1/4 will be done in accordance with the requirements of Section 25 of AWS A5.5.
Very truly yours, D. L. Renberger Assistant Director, Technology DLR:DWC:fa cc:
M.
D. Lynch, Nuclear Regulatory Commission A. Bournia, Nuclear Regulatory Commission foe/
5 jlo